# AD 47-30-07: Trip-Free Circuit Breaker

- Type: Airworthiness directive
- Status: Current
- Products: Textron Army AT-11
- Superseded by: Nothing supersedes this AD
- Product type: Aircraft, Small airplane
- FAA DRS: https://drs.faa.gov/browse/excelExternalWindow/CB5D13B39A341EB386256A1C00720CAC.0001
- DRS record last changed: January 21, 2026
- Page: https://openairdocs.org/ad/47-30-07

## The airworthiness directive

47-30-07 BEECH: (Was Mandatory Note 3 of AD-2-582-2.) Applies Only to AT-11 Aircraft Which Are Not Equipped With Generator Circuit Protective Devices.

To be accomplished prior to certification or, if certificated, on next periodic inspection but not later than October 1, 1947.

In accordance with Figure 1 install a 50-ampere trip-free circuit breaker, Spencer Thermostat Co. PLM-50 or equivalent, between the battery terminal of each generator cutout and its respective ammeter shunt. The circuit breakers should be accessible in flight and labeled respectively: "LEFT GEN. CIRCUIT" and "RIGHT GEN. CIRCUIT."