# Service difficulty reports: N128BZ

A list on [N128BZ](https://openairdocs.org/aircraft/N128BZ.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR BAGA2027072700001](https://openairdocs.org/sdr/BAGA2027072700001.md): Power Supply · failed · Jul 24, 2026 · N128BZ · Emb ERJ190100IGW · Emergency Lighting
  > FLIGHT DECK EMERGENCY LIGHT DOES NOT COME ON WHEN THE EMERGENCY LIGHTS ARE SELECTED ON. REMOVED AND REPLACED THE FWD RH ELPU.
- [SDR BAGA2025091900002](https://openairdocs.org/sdr/BAGA2025091900002.md): Handle · out of position · Sep 19, 2025 · N128BZ · Emb ERJ190100IGW · Emergency Exits
  > EMERGENCY EXIT LH OPEN EICAS INDICATION DURING CLIMB. RETURNED BACK TO FIELD AT MCN. RESET LH OVERWING EMERGENCY EXIT DOOR HANDLE.
- [SDR BAGA2024062500004](https://openairdocs.org/sdr/BAGA2024062500004.md): Shutoff Valve · failed · Jun 23, 2024 · N128BZ · Emb ERJ190100IGW · Cabin Pressure Control System
  > BLEED 2 FAIL, LOSS OF CABIN PRESSURIZATION CONTROL DUE TO BLEED 1 ON MEL. EMERGENCY DECLARED AND RETURNED TO FIELD. CREW OXYGEN DEPLOYED. FINAL INDICATION 1100 PSI. PASSENGER MASKS WERE NOT DEPLOYED.REMOVED AND REPLACED NPRSOV.
- [SDR BAGA2023091800010](https://openairdocs.org/sdr/BAGA2023091800010.md): Unknown · unknown · Aug 29, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Structure (General)
  > CORROSION AROUND FASTENER HOLES - PNL 192CR AT MULTIPLE LOCATIONS - ZONE 100 CORRECTIVE ACTION- PANEL REPLACED
- [SDR BAGA2023091800009](https://openairdocs.org/sdr/BAGA2023091800009.md): Unknown · unknown · Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous Structure
  > CORROSION ON FLOOR SUPPORT AT FR 13 AND Y-11. CORRECTIVE ACTION - REMOVED AND REPLACE DAMAGE FLOOR SUPPORT/DOUBLER AT FR 13 AND -11
- [SDR BAGA2023091800008](https://openairdocs.org/sdr/BAGA2023091800008.md): Floor Support · corroded · Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Main, Structure
  > CORROSION ON ENTRY WAY 9 HOLE FLOOR SUPPORT AROUND FASTENER HOLE AT FR 17 AT Y-13 CORRECTIVE ACTION - REMOVED AND REPLACED 9 HOLE FLOOR SUPPORT PN170-12118-001 AT FRAME 17 Y-13 IAW EMB 190 SRM 51-40-08
- [SDR BAGA2023091800007](https://openairdocs.org/sdr/BAGA2023091800007.md): Unknown · unknown · Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous Structure
  > WET AREA FLR SUPPORT STRUCTURE – SILL – RH BETWEEN FR 84 AND FR 85 AND Y +36 HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTION – REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE SILL RH BETWEEN FR 84 AND FR 85 AND Y+36 PER E-190 SRM 51-40-08
- [SDR BAGA2023091800006](https://openairdocs.org/sdr/BAGA2023091800006.md): Unknown · unknown · Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous Structure
  > WET AREA FLR SUPPORT STRUCTURE BEAM RH I/B BETWEEN FR 86 AND FR 87 HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTIONS - REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE BEAM RH I/B BETWEEN FR 86 AND FR 87 AND Y - 10 PER EMB 190 SRM 51-40-08
- [SDR BAGA2023091800005](https://openairdocs.org/sdr/BAGA2023091800005.md): Unknown · unknown · Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous Structure
  > WET AREA FLR SUPPORT STRUCTURE – BEAM – LH I/B BETWEEN FR 88 AND FR 89 AND Y – 10” HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTION – REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE BEAN LH I/B BETWEEN FR 88 AND FR 89 PER E-190 SRM 51-40-08
- [SDR BAGA2023091800004](https://openairdocs.org/sdr/BAGA2023091800004.md): Unknown · unknown · Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous Structure
  > WET AREA FLR SUPPORT STRUCTURE - CNTR SILL - AT FR 88 AND Y = 0 HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTION: REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE - CENTER SILL AT FR 88 AND Y = 0 PER EMB 190 SRM 51-40-08.
- [SDR BAGA2023091800003](https://openairdocs.org/sdr/BAGA2023091800003.md): Power Supply · inoperative · Aug 16, 2023 · N128BZ · Emb ERJ190100IGW · Emergency Lighting
  > RH MIDDLE EXTERNAL EMERGENCY LIGHT INOP CORRECTIVE ACTION REMOVED AND REPLACED #4 ELPU FOR RH MIDDLE EXTERNAL EMERGENCY LIGHT PER REF EMBRAER 190 AMM 33-50-01. OPS CHECK GOOD. #4 ELPU REMOVED PN-3400-22--10 SN-002752. INSTALLED PN-3400-22-10 SN--001926.
- [SDR BAGA2023091800002](https://openairdocs.org/sdr/BAGA2023091800002.md): Power Supply · discharged · Aug 16, 2023 · N128BZ · Emb ERJ190100IGW · Emergency Lighting
  > BOTH FWD AND MIDDLE LH EXTERNAL EMERGENCY LIGHTS INOP - REMOVED AND REPLACED BOTH #4 AND #5 ELPU FOR THE FWD AND MIDDLE LH EXTERNAL EMERGENCY LIGHTS PER REF EMBRAER 190 AMM 33-50-01. #4 INSTALLED PN-- 3400-22-10 SN-001926, REMOVED PN-3400-22-- 10 SN-00002752.
- [SDR BAGA202306190001](https://openairdocs.org/sdr/BAGA202306190001.md): Power Supply · unserviceable · Jun 16, 2023 · N128BZ · Emb ERJ190100IGW · Emergency Lighting
  > RIGHT HAND OVERWING EMERGENCY EXIT IDENTIFIER SIGN, DOES NOT ILLUMINATE DURING MX, EMERGENCY LIGHT OPERATIONAL TEST. REMOVED AND REPLACE CENTER FUSELAGE II, FWD EMERGENCY LIGHT BATTERY (#3 BATT) REF E190AMM 33-50-01. PERFOMRED CABIN EMERGENCY LIGHT TEST, AL
- [SDR BAGA2023122000027](https://openairdocs.org/sdr/BAGA2023122000027.md): Unknown · unknown · Jan 20, 2023 · N128BZ · Emb ERJ190100IGW · Emergency Equipment
  > THIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. PILOT REPORTED THAT THE R2 SERVICE DOOR WAS DIFFICULT TO ARM/DISARM. PERFORMED OPERATIONAL CHECKS AND TROUBLESHOOTING. NO FAULTS FOUND.
- [SDR BAGA2023122000023](https://openairdocs.org/sdr/BAGA2023122000023.md): Battery · discharged · Dec 20, 2022 · N128BZ · Emb ERJ190100IGW · Emergency Lighting
  > THIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. #6 EMERGENCY LIGHT POWER SUPPLY NOT FUNCTIONING CORRECTLY. REPLACED BATTERY.
- [SDR BAGA2023121900010](https://openairdocs.org/sdr/BAGA2023121900010.md): Shutoff Valve · failed · Sep 14, 2022 · N128BZ · Emb ERJ190100IGW · Landing Gear Brake System
  > THIS SDR SUBMITTED LATE DUE TO AUDIT FINDINGS. BRAKE FAULT MESSAGE ON EICAS. OBSERVED OUTBOARD BRAKES NOT WORKING ON OP CHECK. BCM1 SOV TEST FAILED. REPLACED BRAKE SOV VALVE.
- [SDR BAGA2023121900008](https://openairdocs.org/sdr/BAGA2023121900008.md): Battery · discharged · Aug 19, 2022 · N128BZ · Emb ERJ190100IGW · Emergency Lighting
  > THIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. #1 EMERGENCY LIGHT BATTERY FAULTED DUE TO POWER SUPPLY. BATTERY REPLACED.
- [SDR 2022FA0000330](https://openairdocs.org/sdr/2022FA0000330.md): None · failed · Jul 5, 2022 · N128BZ · Emb ERJ190100IGW · Trailing Edge Flap Control System
  > FLAP FAIL CAUTION MESSAGE ON EICAS AFTER SELECTING FLAPS ZERO AFTER TAKEOFF, RAN QRH PROCEDURE BUT WERE UNABLE TO CLEAR THE MESSAGE - REMOVED AND REPLACED SFACE 2 IAW AMM 27-53-02/400.PERFORMED OPERATIONAL CHECK NUMEROUS TIMES IAW AMM 27-50-00-710-801-A, ALL

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N128BZ' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N128BZ/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.