# Service difficulty reports: N16151

A list on [N16151](https://openairdocs.org/aircraft/N16151.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Page 1 of 4 · 151 reports

- [SDR JJBA20260925012](https://openairdocs.org/sdr/JJBA20260925012.md): Lamp · inoperative · Sep 23, 2026 · N16151 · Emb EMB145XR · Emergency Lighting
  > SERVICE DOOR EXT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED SERVICE DOOR EXT EMERGENCY LAMP. OPS CHECK SAT.
- [SDR JJBA20260922009](https://openairdocs.org/sdr/JJBA20260922009.md): Lamp · inoperative · Sep 21, 2026 · N16151 · Emb EMB145XR · Emergency Lighting
  > LT FWD EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH FWD EXTERIOR EMERGENCY LIGHT LAMP. OPS CHECK SAT.
- [SDR JJBA20260922008](https://openairdocs.org/sdr/JJBA20260922008.md): Battery · inoperative · Sep 21, 2026 · N16151 · Emb EMB145XR · Emergency Lighting
  > INTERIOR EMERGENCY CEILING LIGHTS INOPERATIVE. REMOVED AND REPLACED BPS 4. OPS CHECK SAT
- [SDR JJBA20260901001](https://openairdocs.org/sdr/JJBA20260901001.md): Sign · inoperative · Sep 1, 2026 · N16151 · Emb EMB145XR · Emergency Lighting
  > RIGHT ESCAPE HATCH UPPER SIGN INOPERATIVE. REMOVED AND REPLACED THE RT ESCAPE HATCH UPPER SIGN. OPS CHECKED SAT.
- [SDR JJBA20260810007](https://openairdocs.org/sdr/JJBA20260810007.md): Lamp · inoperative · Aug 9, 2026 · N16151 · Emb EMB145XR · Emergency Lighting
  > OVERWING EMERGENCY LIGHT INOPERATIVE 18CD. REMOVED AND REPLACED RT OVERWING EMERGENCY LIGHT LAMP. OPS CHECK SAT.
- [SDR JJBA20260810006](https://openairdocs.org/sdr/JJBA20260810006.md): Lamp · inoperative · Aug 9, 2026 · N16151 · Emb EMB145XR · Emergency Lighting
  > COCKPIT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED COCKPIT EMERGENCY LIGHT LAMP. OPS CHECK SAT,
- [SDR JJBA20260619013](https://openairdocs.org/sdr/JJBA20260619013.md): Inverter · inoperative · Jun 16, 2026 · N16151 · Emb EMB145XR · Emergency Lighting
  > AFT SIDE OF AFT EMERGENCY EXIT LOCATOR INOPERATIVE. REMOVED AND REPLACED AFT EMERGENCY EXIT LOCATOR LIGHT. OPS CHECK FAILED. REMOVED AND REPLACED EMERGENCY LIGHT DC/AC INVERTER #4. OPS CHECK SAT.
- [SDR JJBA20260415009](https://openairdocs.org/sdr/JJBA20260415009.md): Engine · faulted · Apr 11, 2026 · N16151 · Emb EMB145XR · Engine (Turbine/Turboprop)
  > ENGINE 1 SHUTDOWN INFLIGHT DURING CRUISE. REMOVED PMA AND LWR IGNITER FOR BORESCOPE AND INSTALLED. REMOVED PMA AND LWR IGNITER FOR BORESCOPE AND INSTALLED. REMOVED AND REPLACED ENGINE 1. PERFORMED HIGH POWER RUN. OPS/LEAK CHECK SAT. NO DEFECTS NOTED AT THIS T
- [SDR JJBA20250404034](https://openairdocs.org/sdr/JJBA20250404034.md): Floorbeam · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Main, Floor Beam
  > RH FLOORBEAM CAP CORRODED UNDER BULKHEAD AT LAV. REMOVED CORRODED FLOORBEAM CAP, LOCATED AND DRILLED AND INSTALLED
- [SDR JJBA20250404033](https://openairdocs.org/sdr/JJBA20250404033.md): Floorbeam · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Main, Floor Beam
  > RH FLOORBEAM AT F.S 23 CORRODED. REMOVED AND REPLACED WITH NEW REPAIR DOUBLER ON RH FLOORBEAM AT F.S. 23
- [SDR JJBA20250404032](https://openairdocs.org/sdr/JJBA20250404032.md): Floor Support · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Miscellaneous Structure
  > LH FLOORSILL F.S. 18 - F.S 18A CORRODED. REMOVED CORRODED LH FLOORSILL @ F.S. 18 - F.S. 18A LOCATED AND DRILLED AND INSTALLED NEW SILL.
- [SDR JJBA20250404031](https://openairdocs.org/sdr/JJBA20250404031.md): Floor Support · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Miscellaneous Structure
  > CORROSION ON FLOORSILL AT SERVICE DOOR. REMOVED AND REPLACED FLOORSILL AT SERVICE DOOR.
- [SDR JJBA20250404030](https://openairdocs.org/sdr/JJBA20250404030.md): Floorbeam · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Main, Floor Beam
  > FLOOR SILL AT MOUNT BOLT AT F.S. 22 CORRODED. REMOVED AND REPLACED CAP ON FLOORSILL AT FS22
- [SDR JJBA20250404028](https://openairdocs.org/sdr/JJBA20250404028.md): Floorbeam · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Main, Floor Beam
  > RH FLOORBEAM CAP CORRODED AT MOUNT HOLES FOR LAV. REMOVED RH FLOORBEAM CAP FOR REPLACE, LOCATED, AND DRILLED AND INSSTALLED
- [SDR JJBA20250404027](https://openairdocs.org/sdr/JJBA20250404027.md): Floorbeam · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Main, Floor Beam
  > CENTER FLOORBEAM CAP CORRODED AROUND MOUNT HOLES AT LAV. REMOVED CORRODED FLOORBEAM CAP, LOCATED AND DRILLED NEW
- [SDR JJBA20250404026](https://openairdocs.org/sdr/JJBA20250404026.md): Floor Support · corroded · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Miscellaneous Structure
  > OB FLOORSILL UNDER LAV CORRODED. REMOVED AND REPLACED OB FLOORSILL.
- [SDR JJBA20250401045](https://openairdocs.org/sdr/JJBA20250401045.md): Floor Support · damaged · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Miscellaneous Structure
  > LH FWD FLOORSILL IN CARGO DAMAGED. REMOVED AND REPLACED LH SILL AT LH FLOOR SILL IN CARGO.
- [SDR JJBA20250401044](https://openairdocs.org/sdr/JJBA20250401044.md): Shear Tie · cracked · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Internal Mounting Structure
  > LH SHEAR CLIP AT REAR CABIN BULKHEAD BETWEEN STRINGER 6L AND 7L IS CRACKED. REMOVED AND REPLACED LH SHEAR CLIP AT REAR CABIN BULKHEAD BETWEEN STRINGER 6L AND 7L.
- [SDR JJBA20250401043](https://openairdocs.org/sdr/JJBA20250401043.md): Shear Tie · cracked · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Internal Mounting Structure
  > RH SHEAR CLIP AT REAR CABIN BULKHEAD BETWEEN STRINGER 6R AND 7R IS CRACKED. REMOVED AND REPLACED RH SHEAR CLIP AT REAR CABIN BULKHEAD BETWEEN STR 6R-7R.
- [SDR JJBA20250401042](https://openairdocs.org/sdr/JJBA20250401042.md): Rib · cracked · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Main, Structure
  > RH AFT RIB IN MLG BAY IS CRACKED. REMOVED AND REPLACED RH AFT RIB IN MLG BAY.
- [SDR JJBA20250401041](https://openairdocs.org/sdr/JJBA20250401041.md): Rib · cracked · Mar 21, 2025 · N16151 · Emb EMB145XR · Fuselage Main, Structure
  > LH AFT RIB IN MLG BAY HAS MULTIPLE CRACKS. REMOVED AND REPLACED LH AFT RIB IN MLG BAY.
- [SDR JJBA20250404029](https://openairdocs.org/sdr/JJBA20250404029.md): Floor Support · corroded · Feb 28, 2025 · N16151 · Emb EMB145XR · Fuselage Miscellaneous Structure
  > FLOORSILL OB CORRODED FRM 46-49. REMOVED CORRODED SILL AND LOCATED AND DRILLED AND INSTALLED NEW SILL.
- [SDR JJBA20241223049](https://openairdocs.org/sdr/JJBA20241223049.md): Lamp · inoperative · Dec 21, 2024 · N16151 · Emb EMB145XR · Emergency Lighting
  > LH WTF FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH AFT EXTERNAL EMERGENCY LIGHT LAMP. OPS CHECK SAT
- [SDR JJBA20240716006](https://openairdocs.org/sdr/JJBA20240716006.md): Lamp · inoperative · Jul 15, 2024 · N16151 · Emb EMB145XR · Emergency Lighting
  > LH ABOVE THE WING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH ABOVE THE WING EMERGENCY LIGHT. OPS CHECK SAT
- [SDR JJBA20240429063](https://openairdocs.org/sdr/JJBA20240429063.md): Lamp · inoperative · Apr 27, 2024 · N16151 · Emb EMB145XR · Emergency Lighting
  > COCKPIT EMERGENCY LIGHT OUT. REMOVED AND REPLACED COCKPIT EMERGENCY LIGHT BULB. OPS CHECK GOOD.
- [SDR JJBA20240318063](https://openairdocs.org/sdr/JJBA20240318063.md): Inverter · inoperative · Mar 17, 2024 · N16151 · Emb EMB145XR · Emergency Lighting
  > LH ESCAPE HATCH EXIT IDENTIFIER SIGN INOPERATIVE. REMOVED AND REPLACED LH ESCAPE HATCH EXIT IDENTIFIER SIGN. OPS CHECK FAILED. RESTORED TO ORIGINAL CONFIGURATION. REMOVED AND REPLACED EMERGENCY LIGHT DC/AC INVERTER #5. OPS CHECK SAT
- [SDR JJBA20230315020](https://openairdocs.org/sdr/JJBA20230315020.md): Electronic Unit · inoperative · Mar 14, 2023 · N16151 · Emb EMB145XR · Trailing Edge Flap Control System
  > FLAP LOW SPEED AT ACCELERATION ALTITUDE FOLLOWED BY FLAP FAIL SHORTLY AFTER. REMOVED AND REPLACED FECU. OPS CHECK SAT.
- [SDR JJBA20221117011](https://openairdocs.org/sdr/JJBA20221117011.md): Handle · out of adjust · Nov 14, 2022 · N16151 · Emb EMB145XR · Passenger/Crew Doors
  > NOT ABLE TO OPEN THE MAIN CABIN DOOR FROM INSIDE THE PLANE. REPOSITIONED MAIN CABIN DOOR HANDLE. OPS CHECK GOOD
- [SDR JJBA20220810012](https://openairdocs.org/sdr/JJBA20220810012.md): Light · inoperative · Aug 8, 2022 · N16151 · Emb ERJ170200LR · Emergency Lighting
  > LEFT SIDE ESCAPE HATCH EXIT IDENTIFIER INOPERATIVE. LIGHT FUNCTIONED AFTER RUNNING APU AND PERFORMING FUNCTIONAL TEST. OPS CHECK SAT.
- [SDR JJBA20220427029](https://openairdocs.org/sdr/JJBA20220427029.md): None · inoperative · Apr 27, 2022 · N16151 · Emb EMB145XR · Emergency Lighting
  > FOUND LH LOWER HATCH DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LOWER HATCH DOOR EMERGENCY LIGHT. OPS CHECK SAT
- [SDR JJBA20220123028](https://openairdocs.org/sdr/JJBA20220123028.md): Not Reported · not reported · Jan 23, 2022 · N16151 · Emb EMB145XR · Emergency Lighting
  > MCD EMERGENCY LIGHT INOPERATIVE. REMOVED MCD EMERGENCY LIGHT HOUSING. FOUND BAD GROUND. CLEANED GROUND WIRE RING TERMINAL. REINSTALLED MCD EMERGENCY LIGHT. OPS CHECK SAT
- [SDR JJBA20211005023](https://openairdocs.org/sdr/JJBA20211005023.md): None · none · Oct 5, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > COVER FRAME 68 SHEAR CLIP REPAIR INVESTIGATION. AT FRAME 68 SHEAR CLIP REPAIR REMOVED AT FR 68, SHEAR CLIP REPAIRED.
- [SDR JJBA20210929017](https://openairdocs.org/sdr/JJBA20210929017.md): None · none · Sep 29, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > AFTER NDT INSPECTION, RH FUSE SKIN FOUND CRACKED AT FR 75 BTW STR 2R-3R. RH FUSE SKIN AT FR 75 BTW STR 2R-3R CRACK REMOVED. RH FUSE SKIN AT FR 75 BTW STR 2R-3R REPAIRED
- [SDR JJBA20210924020](https://openairdocs.org/sdr/JJBA20210924020.md): None · none · Sep 24, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > CENTER FUSE I, UNDER FLOOR SKIN CORRODED BTW FRAME 17-19 AND STR 21R-21L. CENTER FUSE I, UNDER FLOOR SKIN BTW FRAME 17-18 AND STR 21R-21L BLENDED FOR INVESTIGATION. AFTER INVESTIGATION, CORROSION ON LOWER SKIN BTW FR 17-19 AND BTW STR 21L-21R FOUND OUT OF LIMI
- [SDR JJBA20210923022](https://openairdocs.org/sdr/JJBA20210923022.md): None · none · Sep 23, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > INSPECT FOR AND TREAT AS NEEDED ANY CORROSION UNDER THE REAR FUSELAGE II NAMEPLATES. ON LOWER REAR FUSE II LH OUTB RIB, BTW FR 79-80 RIB DAMAGED. SPLICE REPAIR ON LOWER REAR FUSE II LH OUTB RIB, BTW FR 79-80 REPAIRED. AT FR 78 NAMEPLATES REMOVED FOR INVESTIGAT
- [SDR JJBA20210923014](https://openairdocs.org/sdr/JJBA20210923014.md): None · none · Sep 23, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > CENTER FUSE IV, UNDER FLOOR, SHEAR CLIP FRAME 60 BTW STR 18R-20R CORRODED. CENTER FUSE IV, UNDERFLOOR, SHEAR CLIP FRAME 60 BTW 18R-20R OUT OF LIMITS. CENTER FUSE IV, POST FR60 REMOVED FOR ACCESS AND SHEAR CLIP FR 60 STR 18R-20R REMOVED FOR REPLACEMENT. CENTER
- [SDR JJBA20210923005](https://openairdocs.org/sdr/JJBA20210923005.md): None · none · Sep 23, 2021 · N16151 · Emb EMB145XR · Nacelle/Pylon Structure
  > AFTER NDT INSPECTION, CRACK FOUND IN LH PYLON YOKE BLIND FASTENER HOLE. HOLE REPAIRED WITH BUSHING AND ALTERNATE MATERIAL
- [SDR JJBA20210922021](https://openairdocs.org/sdr/JJBA20210922021.md): None · none · Sep 22, 2021 · N16151 · Emb EMB145XR · Doors
  > BAGGAGE DOOR SCRATCHED ABOVE FLAPPER DOOR. ON BAGGAGE DOOR ABOVE FLAPPER AREA STRIPPED FOR INVESTIGATION, SCRATCH WITH DENT OUT OF LIMITS. PERFORMED CUT-OUT ON BAGGAGE DOOR. FABRICATED, LOCATED, AND DRILLED REPAIR DOUBLER AND REPAIR FILLER. INSTALLED REPAIR PA
- [SDR JJBA20210922008](https://openairdocs.org/sdr/JJBA20210922008.md): None · none · Sep 22, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > CF2, RH SIDE, FR25 AT FLOOR LEVEL BEHIND SILL, FRAME FOUND CRACKED. FRAME SPLICED.
- [SDR JJBA20210921011](https://openairdocs.org/sdr/JJBA20210921011.md): None · none · Sep 21, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > CENTER FUSE IV, UNDER FLOOR, LH GUSSET BTW FRAME 59-61 CORRODED. OMEGA BEAM BLENDED OUT OF LIMITS BTW FR 60-61. CENTER FUSE IV BTW FR 60-61, LH OMEGA BEAM REPAIRED AND GUSSET REPLACED. NO CORROSION FOUND.
- [SDR JJBA20210913009](https://openairdocs.org/sdr/JJBA20210913009.md): None · none · Sep 13, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > VENTRAL FUEL TANK, FWD SECTION BRACKET CORRODED. WEB REPAIRED. CORROSION LEVEL 1.
- [SDR JJBA20210909013](https://openairdocs.org/sdr/JJBA20210909013.md): None · none · Sep 9, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > CENTER FUSE IV, UNDER FLOOR, CENTER OMEGA BEAM BTW FRAME 59-61 CORRODED. CENTER OMEGA BEAM BTW FR 60-61 IN CENTER FUSE IV UNDERFLOOR, CORROSION UNDER NUT PLATE CUT. CENTER OMEGA BEAM BTW FR60-61 IN CENTER FUSE IV REPAIRED WITH DOUBLER. NO CORROSION FOUND.
- [SDR JJBA20210909012](https://openairdocs.org/sdr/JJBA20210909012.md): None · none · Sep 9, 2021 · N16151 · Emb EMB145XR · Fuselage Structure (General)
  > CENTER FUSE IV, UNDER FLOOR, RH OMEGA BEAM BTW FR 59-61 CORRODED. RH OMEGA BEAM BTW FR 60-61 IN CENTER FUSE IV UNDERFLOOR, CORROSION UNDER NUT PLATE CUT. RH OMEGA BEAM BTW FR60-61 IN CENTER FUSE IV REPAIRED WITH DOUBLER. NO CORROSION FOUND.
- [SDR JJBA20210727024](https://openairdocs.org/sdr/JJBA20210727024.md): Battery Pack · inoperative · Jul 27, 2021 · N16151 · Emb EMB145XR · Emergency Lighting
  > 3 EMERGENCY LIGHTS INOPERATIVE AT ROW 18. REMOVED AND REPLACED #3 EMERGENCY BATTERY. OPS CHECK GOOD.
- [SDR JJBA20210423039](https://openairdocs.org/sdr/JJBA20210423039.md): Light · inoperative · Apr 23, 2021 · N16151 · Emb EMB145XR · Emergency Lighting
  > LOWER EMERGENCY LIGHT AT SEAT 18A INOPERATIVE. R&R EXIT ID SIGN. OPS CHECK SAT.
- [SDR JJBA20210225035](https://openairdocs.org/sdr/JJBA20210225035.md): O-Ring · damaged · Feb 25, 2021 · N16151 · Emb EMB145XR · Engine Bleed Air System
  > BLEED 1 LEAK MESSAGE ON EICAS. (CREW REPORTED AT FL220 MESSAGE APPEARED AND HE DECLARED AN EMERGENCY, THE THEN WENT THROUGH THE CHECKLIST AND WHEN BLEED WAS DESELECTED THE MESSAGE WENT OUT SO HE ADVISED TOWER HE RESOLVED THE ISSUE AND DIDN’T NEED PRIORITY LAND
- [SDR JJBA20201204004](https://openairdocs.org/sdr/JJBA20201204004.md): Wire Harness · disconnected · Dec 4, 2020 · N16151 · Emb EMB145XR · Light System Wiring
  > LT EMERGENCY EXIT ROW LOWER EXIT ID SIGN INOPERATIVE. INSPECTED LT EMERGENCY EXIT IDENTIFIER SIGN AT THE EMERGENCY EXIT ROW AND RE-CONNECTED HARNESS FOR THE PROPER CONNECTION. OPERATIONS CHECK COMPLETED, NO FAULTS FOUND.
- [SDR JJBA20200918040](https://openairdocs.org/sdr/JJBA20200918040.md): Light · missing · Sep 18, 2020 · N16151 · Emb EMB145XR · Emergency Lighting
  > EMERGENCY FLOOR LIGHT PATH, FRONT END OF EACH SIDE STRIP RED BLOCKS ARE MISSING OR WORN. ALSO, MISSING 4 END CAPS AT POSITION 9A, 9CD, 22CD AND FWD RIGHT JUST AFT GALLEY. MULTIPLE LOCATION TRACK IS LOOSE FROM FLOOR. INSTALLED EMERGENCY FLOOR LIGHTING PATH F
- [SDR RAIA2020021750001](https://openairdocs.org/sdr/RAIA2020021750001.md): Clamp · loose · Feb 15, 2020 · N16151 · Emb EMB145XR · Pneumatic Distribution System
  > BLEED LEAK IN FLT--- T/S MSG PER FIM TASK 36-20-00. FOUND FAN AIR VALVE CLAMP LOOSE. SAME RETORQUED. PERFORMED OPS CHECK WITH NO FAULTS NOTED.
- [SDR RAIA202002013001](https://openairdocs.org/sdr/RAIA202002013001.md): Warning Message · false activation · Jan 30, 2020 · N16151 · Emb EMB145XR · Engine Bleed Air System
  > BLEED #1 LEAK IN ICE CONDITIONS. PERFORMED OPS CHECK OF ANTI-ICE SYSTEMS. OPS CHECK GOOD.

Next page: https://openairdocs.org/aircraft/N16151/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N16151' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N16151/reports

---