- [SDR SIMA202602230001](https://openairdocs.org/sdr/SIMA202602230001.md): Battery · inoperative · Feb 20, 2026 · N225NN · Emb ERJ170200LR · Emergency Lighting
  > FOUND FWD OVERHEAD CEILING EMERGENCY LOCATOR LIGHT INOP DURING PS2 CHECK RAR RH EMERGENCY LIGHT POWER UNIT IAW AMM 33-50-01OPC GOOD
- [SDR SIMA20241031001](https://openairdocs.org/sdr/SIMA20241031001.md): Floorbeam · damaged · Oct 31, 2024 · N225NN · Emb ERJ170200LR · Fuselage Main, Floor Beam
  > NRTC F002448-FRAME 78 FLOOR SUPPORT CROSS BEAM TOOL MARKS (MAJOR REPAIR/ ALTERATION) REPAIRED IAW ERS-EJ-53MR-5077.
- [SDR SIMA20240905001](https://openairdocs.org/sdr/SIMA20240905001.md): Roller · lack of lube · Sep 5, 2024 · N225NN · Emb ERJ170200LR · Passenger/Crew Doors
  > MAIN PASSENGER ENTRY DOOR DIFFICULT TO OPEN. LUBRICATED FWD-PASSENGER DOOR COMMAND RAMP ROLLER SHAFT AND BUSHINGS IAW AMM 53-10-21.MAIN ENTRY DOOR OPS CHECKS GOOD AMM 52-11-00.
- [SDR SIMA20240515002](https://openairdocs.org/sdr/SIMA20240515002.md): A/C Pack · odor · May 15, 2024 · N225NN · Emb ERJ170200LR · Cabin Cooling System
  > DURING FLIGHT REPORTS PACK SMELL AND CABIN TEMPERATER UNCONTROLABLE. PERFORMED OPC OF PASSENGER CABIN-ZONE TEMPERATURE CONTROL IAW AMM 21-62-00. OPC GOOD. FOUND NO ABNORMAL SMELL IN CABIN DURING OPC. MEL RESTORED.
- [SDR SIMA202405073001](https://openairdocs.org/sdr/SIMA202405073001.md): Skin · gouged · May 3, 2024 · N225NN · Emb ERJ170200LR · Fuselage Main, Plate/Skin
  > FOUND GOUGE RH SIDE FORWARD FUSELAGE. BETWEEN FRAME 1 AND 2 RIGHT BELOW RVSM AREA, BLEND OUT OF LIMITS OF SRM 53-10-01 "MAJOR REPAIR" PERFORMED PERMANENT REPAIR OF FORWARD FUSELAGE BETWEEN FRAME 1 AND 2 RIGHT BELOW RVSM AREA IAW ENVOY ERS EJ-53-MR-4983 PART A.
- [SDR SIMA20220713001](https://openairdocs.org/sdr/SIMA20220713001.md): Lavatory · smoke · Jul 13, 2022 · N225NN · Emb ERJ170200LR · Waste Disposal System
  > AFT LAV SMELL BURNING FUSE. NO INDICATION ON EICAS.-C/A-NO ODOR FOUND IN LAV. NO MTX REQ. A/C IS GOOD FOR SERVICE.
- [SDR SIMA202204131002](https://openairdocs.org/sdr/SIMA202204131002.md): Coffeemaker · smoke · Apr 13, 2022 · N225NN · Emb ERJ170200LR · Buffet/Galleys
  > THIS IS A SUPPLEMNETAL C/A FOR FA REPORTS SMOKE/BURN SMELL IN CABIN. EMERGENCY DECLARED. BURNING WIRE SMELL IN AFT GALLEY ON TAKE OFF & MIDFLIGHT.-C/A-FOUND COFFEE MAKER TO BE DEFECTIVE. REMOVED AND REPLACED AND OPC AFT INBOARD COFFEE MAKER IAW EMB175 AMM 25-3
- [SDR SIMA20220413002](https://openairdocs.org/sdr/SIMA20220413002.md): None · none · Apr 13, 2022 · N225NN · Emb ERJ170200LR · Cabin Equipment/Furnishings
  > FA REPORTS SMOKE/BURN SMELL IN CABIN. EMERGENCY DECLARED. BURNING WIRE SMELL IN AFT GALLEY ON TAKE OFF & MIDFLIGHT.-C/A-DEFERRED COFFEE MAKER INBD TRAY PER MEL 25-64, C/W M PROCEDURE. PENDING CA
- [SDR SIMA20220331004](https://openairdocs.org/sdr/SIMA20220331004.md): None · none · Mar 31, 2022 · N225NN · Emb ERJ170200LR · Smoke Detection
  > SUPPLEMENTAL CA DECLARED EMERGENCY SHORT OF GATE B40 FOR CARGO SMOKE INDICATOR. CRG FWD VENT FAIL ON GROUND AFTER LANDING.-C/A-FOUND PIECE OF BAGGABIE LOCK NOT ALLOWING FWD CARGO RECIRC SOV TO FULLY CLOSE. REMOVED DEBRIES OK FOR SERVICE IAW EMB AMM 26-16-01.
- [SDR SIMA20211121005](https://openairdocs.org/sdr/SIMA20211121005.md): None · none · Nov 21, 2021 · N225NN · Emb ERJ170200LR · Wing Main, Frame Structure
  > LH WING OUTBD SPAR 1 CRACKED AT WINGTIP ATTACH POINT-C/A-REMOVED AND INSTALLED SERVICEABLE LH WING SPAR 1 AT WINGTIP ATTACH POINT IAW EMB-175 SRM 51-40-08
- [SDR SIMA20211121006](https://openairdocs.org/sdr/SIMA20211121006.md): None · none · Nov 21, 2021 · N225NN · Emb ERJ170200LR · Wing Main, Frame Structure
  > RH WING OUTBD SPAR 1 CRACKED AT WINGTIP ATTACH POINT-C/A-REMOVED AND INSTALLED SERVICEABLE RH WING SPAR 1 AT WINGTIP ATTACH POINT IAW EMB-175 SRM 51-40-08
- [SDR SIMA20211121003](https://openairdocs.org/sdr/SIMA20211121003.md): None · none · Nov 21, 2021 · N225NN · Emb ERJ170200LR · Fuselage Main, Structure
  > L/H CENTER FLOOR BEAM CORRODED FR-16 MARKED-C/A-INSTALLED REPAIR DOUBLER/FILLER ON L/H CENTER FLOOR BEAM FR-16 IAW EMB 175 SRM 53-10-10 RE 01, FIGURE 202
- [SDR SIMA20211121004](https://openairdocs.org/sdr/SIMA20211121004.md): None · none · Nov 21, 2021 · N225NN · Emb ERJ170200LR · Fuselage Main, Structure
  > R/H FLOOR DOUBLER CORRODED BETWEEN FR-12 AND FR-13 AND BETWEEN FR-13 AND FR-14 MARKED-C/A-REMOVED CORRODED AND INSTALLED SERVICEABLE R/H FLOOR DOUBLER BETWEEN FR-12 AND FR-14 IAW EMB 175 SRM 51-40-08 (SEE WIPS AND TASK PERFORMED FOR FURTHER DETAILS)
- [SDR SIMA20211115002](https://openairdocs.org/sdr/SIMA20211115002.md): None · none · Nov 15, 2021 · N225NN · Emb ERJ170200LR · Emergency Lighting
  > CABIN PHOTOLUMINESCENT EMERGENCY LIGHT STRIPS HAVE 8 MISSING ENDCAPS-C/A-COMPLETE:REPLACED 8 MISSING ENDCAPS FROM CABIN EMERGENCY PHOTOLUMINESCENT LIGHT STRIPS IAW ERJ 175 AMM 33-50-21
- [SDR SIMA20210304001](https://openairdocs.org/sdr/SIMA20210304001.md): Manifold · failed · Mar 4, 2021 · N225NN · Emb ERJ170200LR · Landing Gear Steering System
  > ON APPROACH STEERING FAIL MESSAGE ON EICAS EVERY TIME GEAR EXTENDED. NOSEWHEEL STEERING DID INDEED FAIL. ONLY POSSIBLE DIRECTIONAL CONTROL ON GROUND WITH DIFFERENTIAL THRUST & DIFFERENTIAL BRAKING.DECLARED EMERGENCY.-C/A-RAR NOSEWHEEL STEERING MANIFOLD IAW ERJ
- [SDR SIMA2020010230005](https://openairdocs.org/sdr/SIMA2020010230005.md): Deflector · vibration · Dec 30, 2019 · N225NN · Emb ERJ170200LR · Passenger/Crew Doors
  > LOUD VIBS FROM PAX DOOR L1 DOOR TRIM VIBRATING & MAKING LOUD NOISE DECLARED EMERGENCY-C/A-INSPECTED IAW ERJ 175 AMM 52-11-28 FOUND PAX DOOR DEFELECTOR VIBRATING NO FIX. DEFERRED PER CDL 52-01 (M) PROCEDURES COMPLIED WITH. REMOVED AND REPLACED MAINS PAX DOOR D
- [SDR SIMA201811098002](https://openairdocs.org/sdr/SIMA201811098002.md): Door · unknown · Nov 8, 2018 · N225NN · Emb ERJ170200LR · Passenger/Crew Doors
  > MAIN CABIN DOOR WILL NOT OPEN UNLESS " ARMED" AND THEN "DISARMED" A SECOND TIME.-C/A-OPENED MAIN CABIN DOOR IAW EMB 175 AMM 52-11-00-940-001 STEP 3 AND CLOSED IAW 52-11-00-940-003 STEP 12 THROUGH SEVERAL CYCLES. NO FAULT FOUND, DOOR OPENS AND CLOSES NORMALLY.
- [SDR SIMA2018102220004](https://openairdocs.org/sdr/SIMA2018102220004.md): Unknown · odor · Oct 20, 2018 · N225NN · Emb ERJ170200LR · Air Distribution System
  > FA'S REPORTED SOME TYPE OF ELECTRICAL TYPE BURNING SMELL COMING FROM FWD GALLEY ARE ON GROUND. C/A-PERFORMED GVI FOR ELECTRICAL SMELL IN FWD GALLEY AREA INCLUDING COFFEE POTS, LIGHTING BALLAST AND CREW FLSHLIIGHTS. UNABLE TO DETECT ODOR OR ABNORMALITIES. A/C O
- [SDR SIMA201806254001](https://openairdocs.org/sdr/SIMA201806254001.md): Roller · lack of lube · Jun 24, 2018 · N225NN · Emb ERJ170200LR · Passenger/Crew Doors
  > FA REPORTED DIFFICULTY CLOSING FWD PASSENGER DOOR AND DIFFICULTY ON OPENING. FOUND SOME OF THE ROLLERS WERE NOT ROTATE FREELY. CLEANED AND LUBRICATED THE RAMP ROLLER AND BUSHING IAW AMM 53-10-21, OPS CHECKED GOOD.
- [SDR SIMA20160529001](https://openairdocs.org/sdr/SIMA20160529001.md): A/C Pack · failed · May 29, 2016 · N225NN · Emb ERJ170200LR · Cabin Cooling System
  > PASSENGER & FLIGHT ATTENDANT CALLED ABOUT A BURNING ODOR WHILE TAXING. SHORTLY THEREAFTER NR 2 PACK FAILED. DEFERRED IAW MEL 2144. R & R PAC 2 AQCM IAW AMM 21-51-05. OPERATIONS CHECK IS GOOD. MEL ITEM RESTORED.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N225NN' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N225NN/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.