# Service difficulty reports: N368AS

A list on [N368AS](https://openairdocs.org/aircraft/N368AS.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR E07A202603260227](https://openairdocs.org/sdr/E07A202603260227.md): Support Bracket · cracked · Mar 18, 2026 · N368AS · Emb EMB505 · Fuselage Miscellaneous Structure
  > FOUND CRACK ON LH AND RH NOSE OMEGA BEAM FORWARD SUPPORT BRACKET
- [SDR 2025FA0000099](https://openairdocs.org/sdr/2025FA0000099.md): Windshield · cracked · Feb 13, 2025 · N368AS · Emb EMB505 · Flight Compartment Windows
  > LH WINDSHIELD CRACKED IN CLIMB AT FL 270
- [SDR 2025FA0000098](https://openairdocs.org/sdr/2025FA0000098.md): Windshield · cracked · Feb 13, 2025 · N368AS · Emb EMB505 · Flight Compartment Windows
  > LH WINDSHIELD CRACKED IN CLIMB AT FL 270
- [SDR XMXR202107220001](https://openairdocs.org/sdr/XMXR202107220001.md): Shutoff Valve · failed · Jun 6, 2021 · N368AS · Emb EMB505 · Cabin Cooling System
  > ON TAXI OUT. ECS 2 FAIL CAS. ECS DISPLAY SHOWED RED X ON ECS VALVE 2.
- [SDR XMXR20210301004](https://openairdocs.org/sdr/XMXR20210301004.md): Shutoff Valve · failed · Feb 5, 2021 · N368AS · Emb EMB505 · Pneumatic Distribution System
  > BLEED 1 OVER PSI, FOLLOWED BY BLEED1 FAIL IN FLIGHT
- [SDR XMXR20191211022](https://openairdocs.org/sdr/XMXR20191211022.md): Battery Pack · failed · Sep 10, 2019 · N368AS · Emb EMB505 · Emergency Lighting
  > EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.
- [SDR XMXR20191211021](https://openairdocs.org/sdr/XMXR20191211021.md): Battery Pack · failed · Sep 10, 2019 · N368AS · Emb EMB505 · Emergency Lighting
  > EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.
- [SDR E07A201912020005](https://openairdocs.org/sdr/E07A201912020005.md): Precooler · cracked · Jul 1, 2019 · N368AS · Emb EMB505 · Engine Bleed Air System
  > CRACKED RT PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.
- [SDR E07A201912020004](https://openairdocs.org/sdr/E07A201912020004.md): Precooler · cracked · Jun 13, 2018 · N368AS · Emb EMB505 · Engine Bleed Air System
  > CRACKED RH PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.
- [SDR E07A201802230006](https://openairdocs.org/sdr/E07A201802230006.md): Baffle · broken · Feb 21, 2018 · N368AS · Emb EMB505 · Engine Oil Cooler
  > BLEED 1/2 FAIL. IAW SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER. REPLACED PRECOOLER ASSY.
- [SDR E07A201802230005](https://openairdocs.org/sdr/E07A201802230005.md): Baffle · broken · Feb 21, 2018 · N368AS · Emb EMB505 · Engine Oil Cooler
  > BLEED 1/2 FAIL. PER SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.
- [SDR E07A201802140016](https://openairdocs.org/sdr/E07A201802140016.md): Bearing · damaged · Feb 12, 2018 · N368AS · Emb EMB505 · Starter-Generator
  > ENROUTE, CREW RECEIVED A NR 2 GENERATOR OFFLINE, WITH VIBRATION. ENGINE THROTTLED BACK TO IDLE. VIBRATION STILL PRESENT. CREW PERFORMED PRECAUTIONARY ENGINE SHUTDOWN IAW QUICK REFERENCE HANDBOOK AND DIVERTED. RT STARTER FOUND WITH BEARING DAMAGE.
- [SDR E07A201710160001](https://openairdocs.org/sdr/E07A201710160001.md): Interface Unit · inoperative · Oct 13, 2017 · N368AS · Emb EMB505 · Central Warning
  > CREW RECEIVED NUMERIOUS CAS MESSAGES FROM MULTIPLE SYSTEMS. PFD1 WENT INTO REVERSIONARY MODE. GEA 2 WAS DETERMINED TO HAVE GONE OFF LINE.
- [SDR E07A201802140013](https://openairdocs.org/sdr/E07A201802140013.md): Battery Pack · failed · Sep 21, 2017 · N368AS · Emb EMB505 · Emergency Lighting
  > EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON.
- [SDR E07A201802140014](https://openairdocs.org/sdr/E07A201802140014.md): Battery Pack · failed · Sep 20, 2017 · N368AS · Emb EMB505 · Emergency Lighting
  > EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON
- [SDR E07A201608240002](https://openairdocs.org/sdr/E07A201608240002.md): Ahrs · faulted · Aug 23, 2016 · N368AS · Emb EMB505 · Integrated Flight System
  > AHRS1 FAIL, AP/FD FAIL, YAW DAMP FAIL. EMERGENCY DECLARED AND DECENT DUE TO CREW PERCEIVED AHRS2 FAIL THAT WOULD CAUSE VENTRAL RUDDER FAIL AND DUTCH ROLL TENDENCIES. AHRS1 RESTARTED AND ALL SYSTEMS RETURNED TO NORMAL. CMC EVALUATION AND FIM TASK FOR AHRS1 D

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N368AS' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N368AS/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.