- [SDR R61A2026072000195](https://openairdocs.org/sdr/R61A2026072000195.md): Radome · damaged · Jul 20, 2026 · N417YX · Emb ERJ170200LR · Aerodynamic Fairings
  > DROP IN - DAMAGE TO NOSE AT RADOME. REPLACED FR 1 AND GUTTER SRM 51-40-08 AND COMPLIED WITH ETD2026-170-012441 AND ETD2026-170-012474 FOR PERMANENT REPAIR OF NOSE DAMAGE ON RH SIDE AT RADOME
- [SDR R61A2026062600170](https://openairdocs.org/sdr/R61A2026062600170.md): Stringer Splice · damaged · Jun 18, 2026 · N417YX · Emb ERJ170200LR · Fuselage Main, Longeron/Stringer
  > REAR FUSELAGE SUFFERED DAMAGE DURING DE-JACKING OPERATIONS. REAR FUSELAGE STRINGER SPLICE FR93 TO FR 95 STRG 29L AND 29L WAS DAMAGED, PERFORMED PERMANENT REPAIRS IAW ETD2026-170-010714 REV B.
- [SDR R61A2025070200274](https://openairdocs.org/sdr/R61A2025070200274.md): Lug · gouged · Jun 12, 2025 · N417YX · Emb ERJ170200LR · Nacelle/Pylon Miscellaneous Structure
  > WHILE IN HEAVY CHECK - ULTRASONIC INSPECTION CONFIRMS CRACK INDICATION IN #1 ENGINE PYLON OUTBOARD LOWER LINK FITTING. REAMED HOLE ON #1 ENGINE PYLON OUTBOARD LOWER LINK FITTING TO 1.07725" TO REMOVE DAMAGE, REF. SRM 51-10-02. PERFORMED HFEC ROTO PROBE INSPEC
- [SDR R61A2025031000136](https://openairdocs.org/sdr/R61A2025031000136.md): Sensor · failed · Mar 10, 2025 · N417YX · Emb ERJ170200LR · Landing Gear Position and Warning
  > LG WOW SYS FAIL ON TAKEOFF. CREW DECLARED EMERGENCY AND LANDED WITHOUT INCIDENT. PERFORMED FULL SERVICING ON JACKS AND GROUND.
- [SDR R61A2024042900193](https://openairdocs.org/sdr/R61A2024042900193.md): Fadec · faulted · Apr 21, 2024 · N417YX · Emb ERJ170200LR · Engine Controls
  > HALFWAY THROUGH CLIMB, E2 ROLLED BACK TO IDLE. ENG 2 CAME BACK, EICAS CLEARED. E2 TLA FAIL. E2 NO DISPATCH AND E2 SHORT DISPATCH. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R E2 FADEC. R&R THRUST CONTROL QUADRANT.
- [SDR R61A2023042600249](https://openairdocs.org/sdr/R61A2023042600249.md): Power Unit · fault message · Apr 24, 2023 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > EMERGENCY LIGHT BATTERY FAULT. R&R FWD RH EMERGENCY LIGHT POWER UNIT.
- [SDR R61A2023021900156](https://openairdocs.org/sdr/R61A2023021900156.md): Spar · cracked · Feb 18, 2023 · N417YX · Emb ERJ170200LR · Wing, Attach Fittings
  > 170EO-57-20-0050MA_1 RIGHT-OUTBOARD-MAIN WING SPAR 1 INSPECTION AND REWORK SB57-73G1P2. ROUTINE TASK CARD COMPLIED WITH
- [SDR R61A2023021900155](https://openairdocs.org/sdr/R61A2023021900155.md): Spar · cracked · Feb 18, 2023 · N417YX · Emb ERJ170200LR · Wing, Attach Fittings
  > 170EO-57-20-0050MA_1 RIGHT-OUTBOARD-MAIN WING SPAR 1 INSPECTION AND REWORK SB57-73G1P2. ROUTINE TASK CARD COMPLIED WITH
- [SDR R61A2023021800145](https://openairdocs.org/sdr/R61A2023021800145.md): Shear Plate · corroded · Feb 5, 2023 · N417YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > SHEAR CLIP AT FRM 87, STR 27R-28R CORRODED. REMOVED AND REPLACED SHEAR CLIP AT FRAME 87 BETWEEN STGR 27R-28R REF: SRM 51-40-08
- [SDR R61A2021090300683](https://openairdocs.org/sdr/R61A2021090300683.md): Power Supply · inoperative · Sep 2, 2021 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > FWD GALLEY AREA EMERGENCY LIGHT EXIT SIGN IS NOT WORKING. R&R EMERGENCY LIGHT POWER UNIT #1 IAW AMM 33-50-01.
- [SDR R61A2021010500006](https://openairdocs.org/sdr/R61A2021010500006.md): Power Supply · inoperative · Jan 1, 2021 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > OVERHEAD EMERGENCY LIGHT OUT. R & R ELPU NR 1, IAW AMM 33-50-01.
- [SDR R61A2020091800627](https://openairdocs.org/sdr/R61A2020091800627.md): Doubler · corroded · Sep 18, 2020 · N417YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > WHILE IN HEAVY CHECK, MAJOR, COCKPIT RT FLOOR DOUBLER CORRODED BY FR 8, 9, 10, 11, & 12. PERFORMED CUT OUT OF DOUBLER, INSTALLED NEW REPAIR DOUBLER, IAW ETD2020-170-026511.
- [SDR R61A2020071700571](https://openairdocs.org/sdr/R61A2020071700571.md): Hydraulic Line · broken · Jul 16, 2020 · N417YX · Emb ERJ170200LR · Hydraulic System, Main
  > HYDRAULIC 2 LOW PRESSURE. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. REPAIRED BROKEN HYD 2 LINE IN RT WING IAW AMM 20-10-03. CHANGED HYD 2 CASE DRAIN FILTERS AND COMPLIED WITH AMM 05-50-23.
- [SDR R61A2018051840598](https://openairdocs.org/sdr/R61A2018051840598.md): Battery Pack · faulted · May 14, 2018 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > EMERGENCY BATTERY FAULTED. R & R THE EMERGENCY LIGHT BATTER PACK IAW AMM 33-50-01.
- [SDR R61A201804190500](https://openairdocs.org/sdr/R61A201804190500.md): Line · leaking · Apr 19, 2018 · N417YX · Emb ERJ170200LR · Hydraulic System, Main
  > LOSS OF HYDRAULIC SYSTEM 1 DURING FLIGHT. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R & R THE HYDRAULIC PRESSURE LINE IAW 71-00-02. OPS CHECKED GOOD.
- [SDR R61A201704140285](https://openairdocs.org/sdr/R61A201704140285.md): Battery Pack · inoperative · Apr 14, 2017 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > FOUND R1 DOOR EXIT LIGHT INOP DURING TWO DAY CHECK. R&R EMERGENCY BATTERY NR 1 IAW AMM 33-50-01. OPS CHECKED GOOD.
- [SDR R61A201611270694](https://openairdocs.org/sdr/R61A201611270694.md): Flashlight · inoperative · Nov 27, 2016 · N417YX · Emb ERJ170200LR · Emergency Equipment
  > CREW REPORTED THAT THE AFT FLIGHT ATTENDANT FLASHLIGHT WAS INOPERATIVE. MAINTENANCE PERFORMED OPS CHECK OF AFT FLIGHT ATTENDANT FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- [SDR R61A201608310509](https://openairdocs.org/sdr/R61A201608310509.md): Light · inoperative · Aug 31, 2016 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > CREW REPORTED THAT THE EMERGENCY LIGHT IN FIRST CLASS WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LIGHT IAW AMM AND OPS CHECKED GOOD.
- [SDR R61A201608140479](https://openairdocs.org/sdr/R61A201608140479.md): Light · loose · Aug 14, 2016 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > CREW REPORTED THAT THE EMERGENCY LIGHT WAS LOOSE. MAINTENANCE SECURED THE LIGHT IAW AMM AND OPS CHECKED GOOD.
- [SDR R61A201512020894](https://openairdocs.org/sdr/R61A201512020894.md): Smoke Detector · false activation · Dec 2, 2015 · N417YX · Emb ERJ170200LR · Smoke Detection
  > CREW REPORTED THAT THE FORWARD LAV SMOKE DETECTOR ILLUMINATED AND THE CAPTAIN COULD SMELL SMOKE. CREW INSPECTED LAV AND FOUND NO INDICATON OF SMOKE. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. CAPTAIN LATER SPOKE WITH PASSENGER WHO ADMITT
- [SDR R61A201507150447](https://openairdocs.org/sdr/R61A201507150447.md): Battery Pack · inoperative · Jul 15, 2015 · N417YX · Emb ERJ170200LR · Emergency Lighting
  > CREW REPORTED THAT THE L2 EMERGENCY LIGHT ASSY WOULD NOT WORK. MAINTENANCE R & R THE BATTERY PACK IAW AMM AND OPS CHECKED GOOD.
- [SDR R61A201409271077](https://openairdocs.org/sdr/R61A201409271077.md): Warning Message · false activation · Sep 27, 2014 · N417YX · Emb ERJ170200LR · Landing Gear Brake System
  > CREW RECEIVED A RT AND LT BRAKE FAULT MESSAGE ALONG WITH A AUTO BRAKE FAIL MESSAGE. ABORTED TAKEOFF AND RETURNED TO GATE WITHOUT INCIDENT. MAINTENANCE PERFORMED BCM 1 AND 2 IBIT CHECKS IAW AMM WITH NO FAULTS FOUND. MAINTENANCE PERFORMED OPS CHECKS OF HE BRA

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N417YX' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N417YX/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.