# Service difficulty reports: N425YX

A list on [N425YX](https://openairdocs.org/aircraft/N425YX.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR R61A2025101900470](https://openairdocs.org/sdr/R61A2025101900470.md): Stringer · corroded · Oct 2, 2025 · N425YX · Emb ERJ170200LR · Fuselage Main, Longeron/Stringer
  > CENTER FUSELAGE III STRINGER 23L CORRODED.: REMOVED, REPAIRED AND REPLACED CENTER FUSELAGE III STRINGER 23L BETWEEN FR74-FR90 AND STRINGER 23L SPLICE FR81-FR82. REF:ETD2025-170-929671 AND EMB SRM 51-40-08.
- [SDR R612025F00004](https://openairdocs.org/sdr/R612025F00004.md): Plate · chafed · Sep 28, 2025 · N425YX · Emb ERJ170200LR · Nacelle/Pylon Miscellaneous Structure
  > #2 ENGINE OUTBOARD T/R CENTER THERMAL BLANKET CHAFE PLATE CHAFED.REMOVED DAMAGED CHAFE PLATE, FABRICATE REPAIR PATCH REF.NO. REPUBLIC AIRWAYS 170EA--78-31-0004MR_1 REV 2.
- [SDR R61A2025101900471](https://openairdocs.org/sdr/R61A2025101900471.md): Plate · chafed · Sep 28, 2025 · N425YX · Emb ERJ170200LR · Nacelle/Pylon Miscellaneous Structure
  > #1 ENGINE INBOARD T/R CENTER THERMAL BLANKET CHAFE PLATE CHAFED.REMOVED DAMAGED CHAFE PLATE, FABRICATE REPAIR PATCH.REF.NO.REPUBLIC AIRWAYS 170EA-78-31-0004MR_1 REV 2.
- [SDR R61A2025101900469](https://openairdocs.org/sdr/R61A2025101900469.md): Plate · chafed · Sep 28, 2025 · N425YX · Emb ERJ170200LR · Nacelle/Pylon, Main Frame
  > #1 ENGINE INBOARD T/R CENTER THERMAL BLANKET CHAFE PLATE CHAFED. REPAIRED PER REPUBLIC AIRWAYS 170EA-78-31-0004MR_1REV2
- [SDR R61A202501020001](https://openairdocs.org/sdr/R61A202501020001.md): Fcu · faulted · Dec 29, 2024 · N425YX · Emb ERJ170200LR · Fuel Indicating System
  > FUEL 1 LOW LEVEL ON SHORT FINAL, DESPITE 7200LBS FUEL IN TANK. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R FUEL CONDITIONING UNIT.
- [SDR R61A2024122300594](https://openairdocs.org/sdr/R61A2024122300594.md): Warning Message · illuminated · Dec 20, 2024 · N425YX · Emb ERJ170200LR · Fuel Quantity Indicator
  > FUEL 1 LOW LEVEL MESSAGE IN FLIGHT. OCCURRED AT FL230 ON DESCENT FROM FL280. NO OTHER INDICATIONS THAT FUEL MIGHT BE LOW. FUEL LEVEL WAS APPROXIMATELY 4650 WITH INDICATION OF NO MORE THAN 40 LBS DIFFERENCE BETWEEN TANKS. DECLARED EMERGENCY, LANDED WITHOUT INCI
- [SDR R61A2024061700271](https://openairdocs.org/sdr/R61A2024061700271.md): Gcu · failed · Jun 15, 2024 · N425YX · Emb ERJ170200LR · AC Generator-Alternator
  > ELECTRICAL EMERGENCY. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R GCU1.
- [SDR R61A2023063000372](https://openairdocs.org/sdr/R61A2023063000372.md): Seat Track · corroded · Jun 10, 2023 · N425YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach Fittings
  > AFT SEAT TRACK AT FR 82 MINOR CORROSION FOUND. REPAIRED IAW 53-00-10, NO CRACKS FOUND.
- [SDR R61A2023063000371](https://openairdocs.org/sdr/R61A2023063000371.md): Gusset · corroded · Jun 10, 2023 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > O/B FLOOR GUSSET AT FR 85 CORRODED. R&R IAW SRM 51-41-02, 51-41-01, 51-43-04.
- [SDR R61A2023063000373](https://openairdocs.org/sdr/R61A2023063000373.md): Seat Track · corroded · Jun 8, 2023 · N425YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach Fittings
  > FWD R/H I/B SEAT TRACK AT FR 19 CORRODED. R&R IAW SRM 51-41-02, 51-43-01.
- [SDR R61A2023063000370](https://openairdocs.org/sdr/R61A2023063000370.md): Shear Panel · corroded · Jun 8, 2023 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > MID SHEAR PNL BTWN FR 87-88 CORRODED. R&R IAW SRM 51-42-01.
- [SDR R61A2023063000369](https://openairdocs.org/sdr/R61A2023063000369.md): Seal Depressor · corroded · Jun 8, 2023 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > FWD CARGO DOOR SURND AFT SEAL DEPRESS ANGLE UPPER & LOWER CORRODED. R&R IAW AMM 20-10-01.
- [SDR R61A2023063000368](https://openairdocs.org/sdr/R61A2023063000368.md): Seal Depressor · corroded · Jun 8, 2023 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > FWD CARGO DOOR SURND FWD SEAL DEPRESS ANGLE UPPER & LOWER CORRODED. R&R IAW AMM 20-10-01.
- [SDR R61A2023063000367](https://openairdocs.org/sdr/R61A2023063000367.md): Seal Depressor · corroded · Jun 8, 2023 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > FWD CARGO DOOR SURND MID SEAL DEPRESS ANGLE UPPER & LOWER CORRODED. R&R IAW SRM 51-41-01.
- [SDR R61A2023063000366](https://openairdocs.org/sdr/R61A2023063000366.md): Shear Panel · corroded · Jun 8, 2023 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > R/H SHEAR PNL BTWN FR 87-88 FOUND CORRODED. R&R IAW SRM 51-42-01.
- [SDR R61A2023063000374](https://openairdocs.org/sdr/R61A2023063000374.md): Stabilizer · cracked · Jun 5, 2023 · N425YX · Emb ERJ170200LR · Empennage Structure
  > CRACK FOUND ON R/H H-STABRIB 11A. "MAJOR". CARD RAISED FOR 170EO-55-10-0004 RPAIR. CRACK LENGHT.075
- [SDR R61A2021073000613](https://openairdocs.org/sdr/R61A2021073000613.md): Unknown · odor · Jul 29, 2021 · N425YX · Emb ERJ170200LR · Air Distribution System
  > BURNING SMELL ON TAKEOFF ROLL, DISSIPATED AFTER EXITING RUNWAY. PERFORMED OPS CHECK OF AC PACK SYSTEM IAW AMM 21-00-00. OPS CHECKED GOOD, NO BURNING SMELL NOTED. TAXI AIRCRAFT AROUND FIELD, NO BURNING SMELL NOTED IAW AMM 9-22-01.
- [SDR R61A2020072300573](https://openairdocs.org/sdr/R61A2020072300573.md): Light · inoperative · Jul 22, 2020 · N425YX · Emb ERJ170200LR · Emergency Lighting
  > PHOTOLUMINESCENT STRIPS INOP AT LOCATIONS SEATS 2A, FWD CLOSET AREA, (2 PIECES), AND 22-23DF. R&R PHOTOLUMINESCENT STRIPS AT LOCATIONS SEATS 2A, FWD CLOSET AREA, AND SEATS 22/23DF.
- [SDR R61A202003200425](https://openairdocs.org/sdr/R61A202003200425.md): Glowstrip · damaged · Mar 20, 2020 · N425YX · Emb ERJ170200LR · Emergency Equipment
  > PHOTOLUMINESCENT STRIP LIGHT AT 1A DAMAGED. R&R 1A PHOTOLUMINESCENT STRIP IAW AMM 33-50-21.
- [SDR R61A2019062520647](https://openairdocs.org/sdr/R61A2019062520647.md): Circuit Breaker · tripped · Jun 22, 2019 · N425YX · Emb ERJ170200LR · Emergency Lighting
  > EMERGENCY LIGHT ON IN ARMED POSITION WITH POWER ON A/C. FOUND EMERGENCY FWD BATTERY CIRCUIT BREAKER POPPED. RESET CIRCUIT BREAKER PER AMM 33-50-00.
- [SDR R61A201903230305](https://openairdocs.org/sdr/R61A201903230305.md): Glowstrip · damaged · Mar 23, 2019 · N425YX · Emb ERJ170200LR · Emergency Equipment
  > RT FWD PHOTOLUMINESCENT STRIP MISSING SMALL PIECE. R&R PHOTOLUMINESCENT STRIP IAW AMM 33-50-21. OPS CHECK GOOD.
- [SDR R61A201903160287](https://openairdocs.org/sdr/R61A201903160287.md): Glowstrip · inoperative · Mar 16, 2019 · N425YX · Emb ERJ170200LR · Emergency Equipment
  > THE PHOTOLUMINESCENT STRIP, AIRCRAFT RIGHT AT ROW 2 IS INOP. R&R THE PHOTOLUMINESCENT STRIP ON ROW 2 IAW AMM 33-50-21.
- [SDR R61A2018110231103](https://openairdocs.org/sdr/R61A2018110231103.md): Mechanism · lack of lube · Oct 31, 2018 · N425YX · Emb ERJ170200LR · Service Doors
  > R1 DOOR DIFFICULT TO ARM AND DISARM. CLEANED AND LUBRICATED THE R1 DOOR ARM DISARM MECHANISM. PERFORMED AN OPS CHECKED IAW AMM 52-11-40.
- [SDR R61A2018082400904](https://openairdocs.org/sdr/R61A2018082400904.md): Light · inoperative · Aug 20, 2018 · N425YX · Emb ERJ170200LR · Emergency Lighting
  > COCKPIT EMERGENCY LIGHT NOT WORKING. R&R COCKPIT EMERGENCY LIGHT ASSEMBLY.
- [SDR R61A201808110869](https://openairdocs.org/sdr/R61A201808110869.md): Splice Plate · corroded · Aug 11, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > CORROSION FOUND ON THE LT SPLICE PLATE AROUND FASTENER HOLES, FRAMES 87 - 88. REMOVED AND REPLACED THE SPLICE PLATE IAW SRM 51-40-08.
- [SDR R61A201808110868](https://openairdocs.org/sdr/R61A201808110868.md): Closeout Panel · corroded · Aug 11, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > CORROSION AND LIGHT CHAFING ON THE FORWARD CARGO DOOR LOWER BEAM CLOSE OUT. REMOVED AND REPLACED FORWARD CARGO DOOR LOWER BEAM CLOSE OUT REF SRM 51-40-08. PN 170-67451-001
- [SDR R61A201808110867](https://openairdocs.org/sdr/R61A201808110867.md): Shear Panel · corroded · Aug 11, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > RT SHEAR PANEL, FRAMES 87 - 88 CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-40-08.
- [SDR R61A201808110866](https://openairdocs.org/sdr/R61A201808110866.md): Shear Panel · corroded · Aug 11, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > LEFT SHEAR PANEL AT FRAMES 87 - 88 CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-40-08.
- [SDR R61A201808170879](https://openairdocs.org/sdr/R61A201808170879.md): Seat Track · corroded · Aug 4, 2018 · N425YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach Fittings
  > CORROSION FOUND ON THE LT INBD SEAT TRACK AT FRAME 28. INSTALLED A FILLER AND SPLICE PLATE IAW ETD2018-170-084939, AND SRM 53-00-10, REPAIR 01P.
- [SDR R61A201808170878](https://openairdocs.org/sdr/R61A201808170878.md): Seat Track · corroded · Aug 3, 2018 · N425YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach Fittings
  > CORROSION FOUND ON THE RT, INBD SEAT TRACK, BETWEEN FRAMES 84 - 85. BLENDED OUT THE CORROSION IAW ETD2018-170-084523.
- [SDR R61A201808170877](https://openairdocs.org/sdr/R61A201808170877.md): Seat Track · corroded · Aug 3, 2018 · N425YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach Fittings
  > CORROSION FOUND ON THE RT, INBD SEAT TRACK AT FRAME 17. REMOVED AND REPLACED THE SEAT TRACK IAW SRM 51-40-08.
- [SDR R61A201808170876](https://openairdocs.org/sdr/R61A201808170876.md): Floor Support · corroded · Aug 3, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > CORROSION FOUND ON THE RT FLOOR SUPPORT, FRAMES 13 - 14. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-08.
- [SDR R61A201808170875](https://openairdocs.org/sdr/R61A201808170875.md): Splice · corroded · Aug 3, 2018 · N425YX · Emb ERJ170200LR · Fuselage Main, Structure
  > CORROSION FOUND ON THE RT SPLICE AT FRAME 89. REMOVED AND REPLACED THE SPLICE IAW SRM 51-40-08.
- [SDR R61A201808170874](https://openairdocs.org/sdr/R61A201808170874.md): Support · corroded · Aug 3, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > CORROSION ON THE RT PANEL SUPPORT, FRAMES 88 - 89. REMOVED AND REPLACED THE PANEL SUPPORT IAW SRM 51-40-08.
- [SDR R61A201808170873](https://openairdocs.org/sdr/R61A201808170873.md): Door · corroded · Aug 2, 2018 · N425YX · Emb ERJ170200LR · Fluid Service Doors
  > WASTE SERVICE DOOR AT THE REAR FUSELAGE AREA HAD CORROSION ON THE INSIDE OF THE DOOR WHERE BONDING WIRE ATTACHES. REMOVED AND REPLACED WASTE SERVICE DOOR IAW SRM 51-42-08.
- [SDR R61A201808170872](https://openairdocs.org/sdr/R61A201808170872.md): Support Angle · corroded · Aug 2, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > CORROSION ON THREE LOWER ANGLES ON PANEL 1441FR. REMOVED AND REPLACED THE ANGLES IAW AMM 20-10-01, AND SRM 51-40-02.
- [SDR R61A201808170871](https://openairdocs.org/sdr/R61A201808170871.md): Support Angle · corroded · Aug 2, 2018 · N425YX · Emb ERJ170200LR · Fuselage Miscellaneous Structure
  > CORROSION ON THREE LOWER ANGLES ON PANEL 1431DL. REMOVED AND REPLACED THE ANGLES IAW SRM 51-40-08, SRM 51-40-02, SRM 51-23-04, AND 51-23-05.
- [SDR R61A201806070679](https://openairdocs.org/sdr/R61A201806070679.md): Loop · faulty · Jun 7, 2018 · N425YX · Emb ERJ170200LR · Pneumatic Indicating System
  > BLEED 2 LEAK. MASKS DEPLOYED. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R ODS LOOP 5 SECTION 2RT0060 IAW AMM 36-21-02. OPS CHECK GOOD. ALL O2 GENERATORS WERE REPLACED AND MASKS STOWED.
- [SDR R61A201510290767](https://openairdocs.org/sdr/R61A201510290767.md): Light · damaged · Oct 29, 2015 · N425YX · Emb ERJ170200LR · Emergency Lighting
  > CREW REPORTED THAT THE PHOTOLUMINESCENT STRIP WAS DAMAGED. MAINTENANCE R & R PHOTOLUMINESCENT STRIP IAW AMM AND OPS CHECKED GOOD.
- [SDR R61A201509080619](https://openairdocs.org/sdr/R61A201509080619.md): Flashlight · missing · Sep 8, 2015 · N425YX · Emb ERJ170200LR · Emergency Equipment
  > CREW REPORTED THAT THE AFT JUMPSEAT FLASHLIGHT WAS MISSING. MAINTENANCE REPLACED MISSING FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- [SDR R61A201508290563](https://openairdocs.org/sdr/R61A201508290563.md): Coffeemaker · failed · Aug 29, 2015 · N425YX · Emb ERJ170200LR · Buffet/Galleys
  > F/A NOTICED SMOKE COMING FROM BOTTOM OF COFFEEMAKER. F/A TURNED POWER TO COFFEEMAKER OFF AND SMOKE STOPPED. CREW CONTACTED MAINTENANCE CONTROL AND CONTINUED TO DESTINATION WITH NO FURTHER ISSUES. MAINTENANCE R & R COFFEEMAKER IAW AMM AND OPS CHECKED GOOD.
- [SDR R61A201506210381](https://openairdocs.org/sdr/R61A201506210381.md): Battery Pack · inoperative · Jun 21, 2015 · N425YX · Emb ERJ170200LR · Emergency Lighting
  > CREW REPORTED THAT THE FLIGHT DECK EMERGENCY LIGHT WOULD NOT TEST. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy