- [SDR HNAA2021101200493](https://openairdocs.org/sdr/HNAA2021101200493.md): None · none · Oct 6, 2021 · N603KC · Emb EMB145LR · Gust Lock Damper System
  > PDIS 603 27-70 2467201 06OCT21 GSO CLOSE ELE GUST LOCK WILL NOT DISENGAGE FACT 06OCT21 21:49 CLT PERFORMED OPS CHECK IAW 27-71-00-700-803-A GUST LOCK SYSTEM OPERATES NORMALLY NO DEFECTS FOUND. CLEARED MEL 27-11 SAME LP
- [SDR HNAA2021062200269](https://openairdocs.org/sdr/HNAA2021062200269.md): Unknown · odor · Jun 21, 2021 · N603KC · Emb EMB145LR · Air Distribution System
  > POSSIBLE LIGHTNING STRIKE WITH NO AVIONIC ISSUES BUT NOTED PLASTIC BURNING SMELL IN FLIGHT DECK. C/W LIGHTING STRIKE INSP IAW EMB 145 AMM 05-50-01 TASK 05-50-01-200-801-A. NO DAMAGE NOTED. OK FOR SERVICE
- [SDR HNAA2021040500129](https://openairdocs.org/sdr/HNAA2021040500129.md): Engine · malfunctioned · Apr 5, 2021 · N603KC · Emb EMB145LR · Engine (Turbine/Turboprop)
  > NO. 2 ENGINE WILL NOT START WITH 2 ATTEMPTS. HEAVY FUEL SMELL IN CABIN AND FLIGHT DECK. PERFORMED FIM TASK 72-33-33-810-824. ENIGNE RETURNED TO SERVICE DUE TO NO FAULTS FOUND
- [SDR HNAA2021040500128](https://openairdocs.org/sdr/HNAA2021040500128.md): Handle · out of adjust · Apr 2, 2021 · N603KC · Emb EMB145LR · Passenger/Crew Doors
  > PDIS 603 52-10 2425751 02APR21 ALB CLOSE MAIN DOOR WILL NOT OPEN FROM INSIDE FACT 02APR21 07:01 ALB READJUSTED INSIDE DOOR LATCH HANDLE IRW EMB 145 AMM 52-18-05 OPS CHECK GOOD PER EMB 145 AMM 52-18-00
- [SDR HNAA2021011200011](https://openairdocs.org/sdr/HNAA2021011200011.md): Dau · failed · Jan 11, 2021 · N603KC · Emb EMB145LR · Navigation System
  > AT ROTATION, DAU1A FAILURE MESSAGE WITH LOSS OF ALL ENGINE 1 AND APU PARAMETERS AND ASSOCIATED COMPONENTS WITH 115VAC BUSS OFF MESSAGE FOR 5 MINUTES AND CAME BACK ON MOMENTARILY AND CYCLED BACK OFF. R & R THE NR 1 DAU, IAW AMM 31-41-01. NO FAIL MESSAGES WERE
- [SDR HNAA2020063000187](https://openairdocs.org/sdr/HNAA2020063000187.md): Battery Pack · inoperative · Jun 26, 2020 · N603KC · Emb EMB145LR · Emergency Lighting
  > FWD LEFT EMERGENCY LIGHT WAS INOPERATIVE, EXTERIOR. R & R THE EMERGENCY BATTERY AND POWER SUPPLY IAW AMM 33-50-04-000/400-801A, OPS CHECKED GOOD.
- [SDR HNAA2020012000026](https://openairdocs.org/sdr/HNAA2020012000026.md): Ballast · failed · Jan 19, 2020 · N603KC · Emb EMB145LR · Passenger Compartment Lighting
  > STRONG ELECTRICAL/BURNING SMELL COMING FROM FRONT OF A/C (VERY PROMINANT FROM FWD FA VENT). FOUND BURNT OUT LH SIDE WALL BALLEST. REMOVED AND REPLACED BURNT BALLAST IAW 33-21-03. OPS CHECK GOOD OK FOR SERVICE. INSPECTED LIGHT SOCKETS, NO DEFECTS FOUND IN SUROU
- [SDR HNAA2019081400227](https://openairdocs.org/sdr/HNAA2019081400227.md): Light · inoperative · Aug 13, 2019 · N603KC · Emb EMB145LR · Emergency Lighting
  > NR 5 EMERGENCY LIGHT STRIP INOPERATIVE. R & R THE PROXIMITY LIGHT STRIP IAW AMM 33-50-12-400-801-A
- [SDR HNAA2019070100187](https://openairdocs.org/sdr/HNAA2019070100187.md): Warning System · false activation · Jun 30, 2019 · N603KC · Emb EMB145LR · Pneumatic Indicating System
  > AIRCRAFT 603 ABORT T/O IN PHL DUE TO MOMENTARY HSV FAIL MESSAGE ON T/O. NO HISTORY. FIX: CREW RECONFIGURED AC AND PERO CHK. ALL SYSTEMS OPS NORM THROUGH STANDARD CREW PROCEDURES.
- [SDR HNAA2019060300157](https://openairdocs.org/sdr/HNAA2019060300157.md): Unknown · odor · May 30, 2019 · N603KC · Emb EMB145LR · Air Distribution System
  > PDIS 603 05-50 1851062 30MAY19 CLT CLOSE CREW REPORTS BURNING RUBBER SMELL FROM 80 KTS TO 6000 FEET FACT GROUND RAN AIRCRAFT WITH BLEEDS ON. NO RUBBER SMELL NOTED. SUSPECT ODOR WAS FROM
- [SDR HNAA2019021300043](https://openairdocs.org/sdr/HNAA2019021300043.md): Terminal Block · burned · Feb 12, 2019 · N603KC · Emb EMB145LR · Ice/Rain Protection System Wiring
  > NDIS 603 30-41 0020580 09FEB19 CLT CLOSE PLEASE FOLLOW UP WITH WIND SCREEN HEAT OPS CHECK FOR #2 W/S DUE TO OCCASIONAL OCCURANCES OF FAIL INDICATIONS THEN INSTANTLY CLEARING ITSELF AND OPERATING NORMALLY. DFRL 09FEB19 10:53 CLT
- [SDR HNAA2019020400033](https://openairdocs.org/sdr/HNAA2019020400033.md): Relay · malfunctioned · Feb 1, 2019 · N603KC · Emb EMB145LR · Central Warning
  > PDIS 603 31-50 1983712 01FEB19 PHL CLOSE NO TAKE OFF CONFIG WARNING DURING TAKE OFF. FACT 01FEB19 15:23 PHL T/S IAW EMB FIM 31-51-00-810-804A BLOCK 1. R/R RELAY K0212 IA
- [SDR HNAA2018091900226](https://openairdocs.org/sdr/HNAA2018091900226.md): Solenoid · failed · Sep 18, 2018 · N603KC · Emb EMB145LR · Engine Thrust Reverser
  > ENG 1 IDLE STOP FAIL AFTER ENGINE START. IDLE STOP SOLENOID.
- [SDR HNAA2018091900225](https://openairdocs.org/sdr/HNAA2018091900225.md): Relay · failed · Sep 17, 2018 · N603KC · Emb EMB145LR · Engine Thrust Reverser
  > E1 IDLE STOP FAIL. TROUBLESHOT IN REF TO FIM 76-13-810-801-A PG 210 BLOCK 32. FAILURE OF RELAY K0257. R&R RELAY K0257 IN REF TO AMM 20-13-02-04. OPS CHECK GOOD AT THIS TIME OK FOR SERVICE.
- [SDR HNAA2018082400206](https://openairdocs.org/sdr/HNAA2018082400206.md): None · none · Aug 23, 2018 · N603KC · Emb EMB145LR · Trailing Edge Flaps
  > NDIS 603 31-33 0015960 22AUG18 SBY CLOSE MAINTENANCE FOLLOW UP: PREVIOUSLY RECORDED FDR DATA VALIDATED ON 8/23/18 INDICATES THAT A/C EXCEDED THE AIRSPEED/FLAP POSITION OPERAIONAL LIMIT
- [SDR HNAA2018072700175](https://openairdocs.org/sdr/HNAA2018072700175.md): Steering Sys · out of adjust · Jul 26, 2018 · N603KC · Emb EMB145LR · Landing Gear Steering System
  > DURING TRAXI AND TAKEOFF ROLL AIRCRAFT PULLS TO THE LEFT. PERFORMED NWS SYSTEM QUICK ADJUSTMENT IAW AMM 32-50-00 OPS CHECK GOOD OK FOR SERVICE.
- [SDR HNAA2018072300163](https://openairdocs.org/sdr/HNAA2018072300163.md): Warning System · false activation · Jul 22, 2018 · N603KC · Emb EMB145LR · Central Computers
  > DAU NR 2 SYS MISCMP EICAS MSG ON TAKEOFF. PERFORMED T/S IAW FIM 31-41-00-817-006A BLOCKS 1, 2, 14. FOUND TO BE CONDITION ON IC 1, DAU NR 1 AND NR 2. OPS CHECK GOOD OK FOR SERVICE.
- [SDR HNAA2018061200120](https://openairdocs.org/sdr/HNAA2018061200120.md): Bulb · inoperative · Jun 8, 2018 · N603KC · Emb EMB145LR · Emergency Lighting
  > SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. R & R THE BULB.
- [SDR HNAA2018061280120](https://openairdocs.org/sdr/HNAA2018061280120.md): Bulb · inoperative · Jun 8, 2018 · N603KC · Emb EMB145LR · Emergency Lighting
  > SERVICE DOOR EMERGENCY LIGHT WAS INOPERATIVE. R & R THE BULB.
- [SDR HNAA2018033000076](https://openairdocs.org/sdr/HNAA2018033000076.md): Power Supply · inoperative · Mar 29, 2018 · N603KC · Emb EMB145LR · Emergency Lighting
  > RIGHT FWD EMERGENCY LIGHT INOPERATIVE. MULTIPLE INTERIOR OVERHEAD AND EMERGENCY LIGHTS INOPERATIVE. R & R THE BATTERY AND POWER SUPPLY ASSY IAW AMM 33-58-04-400-801-A.
- [SDR HNAA2017110900374](https://openairdocs.org/sdr/HNAA2017110900374.md): Controller · malfunctioned · Nov 8, 2017 · N603KC · Emb EMB145LR · Windshield/Door Rain/Ice Removal
  > WINDSHIELD HEAT NR 1 FAIL MESSAGE DISPLAYED IN FLT. NOT IN ICING CONDITIONS. R & R THE NR 1 WINDSHIELD HEAT CONTROLLER IAW AMM 30-42-01. OPS CHECKED IAW AMM 30-42-00. OPS CHECKED GOOD. OKAY FOR SERVICE.
- [SDR HNAA2017090500296](https://openairdocs.org/sdr/HNAA2017090500296.md): Spring · out of adjust · Sep 2, 2017 · N603KC · Emb EMB145LR · Windshield/Door Rain/Ice Removal
  > CAPT'S WINDSHIELD WIPER WILL NOT PARK AND BOUNCES OFF OF WINDSHIELD AT SPEEDS ABOVE 160 KNOTS. ADJUSTED WIPER ARM SPRING TENSION IAW AMM 30-41-03 OPS CHECK GOOD AT THIS TIME.
- [SDR HNAA2017073100252](https://openairdocs.org/sdr/HNAA2017073100252.md): Light · inoperative · Jul 25, 2017 · N603KC · Emb EMB145LR · Emergency Lighting
  > FLOOR PROXIMITY EMERGENCY LIGHTS AND EXIT DOOR EMERGENCY LIGHTS WILL NOT ILLUMINATE
- [SDR HNAA2017040300101](https://openairdocs.org/sdr/HNAA2017040300101.md): Switch · failed · Mar 31, 2017 · N603KC · Emb EMB145LR · Ice/Rain Protection System
  > WING ANTI ICE FAIL MESSAGE, ICE CONDITION ANTI ICE WARNING, AND BLEED 1 LEAK EICAS MESSAGES DISPLAYED. RETURNED TO THE FIELD. FOUND BROKEN WIRES TO THE THERMAL SWITCH ON THE NR 1 ANTI ICE VALVE. R & R THE THERMAL SWITCH IAW AMM 36-20-02-400-801-A. PERFORME
- [SDR HNAA2017032900097](https://openairdocs.org/sdr/HNAA2017032900097.md): Warning Message · false activation · Mar 28, 2017 · N603KC · Emb EMB145LR · Airfoil Anti/De-ice System
  > DURING FLIGHT IN ICING CONDITIONS, AN EICAS MESSAGE FOR THE STAB ANTI-ICE FAILED, FOLLOWED BY A WARNING MESSAGE. GROUND RAN THE ACFT AND PERFORMED AN ANTI ICE VALVE TEST IAW AMMM 30-21-00-700-804-A/500, NO DEFECTS NOTED AT THIS TIME. OK FOR SERVICE.
- [SDR HNAA2017032700095](https://openairdocs.org/sdr/HNAA2017032700095.md): Line · cracked · Mar 25, 2017 · N603KC · Emb EMB145LR · Airfoil Anti/De-ice System
  > EICAS MESSAGE. ANTI-ICE FAILED. DOWNLOAD SHOWED WING ANTI-ICE FAILED MESSAGE.FOUND LEFT WING REFERENCE LINE CRACKED. R & R THE LINE, OPS CHECKED GOOD, OK FOR SERVICE.
- [SDR HNAA2017030800078](https://openairdocs.org/sdr/HNAA2017030800078.md): Engine · unknown · Mar 8, 2017 · N603KC · Emb EMB145 · Engine (Turbine/Turboprop)
  > NR 2 ENGINE FAILED TO START. FIRST START, ENGINE DID NOT REACH 30 N2. SECOND START, ENGINE DID GET TO 30 N2, BUT THEN SHUTDOWN. NO WARNING OR CAUTION MESSAGE. STARTED AIRCRAFT ENGINES SEVERAL TIMES IAW RUN UP CHECKLIST. ENGINES STARTED WITH NO DEFECTS. OK F
- [SDR HNAA2017011800024](https://openairdocs.org/sdr/HNAA2017011800024.md): Connector · contaminated · Jan 18, 2017 · N603KC · Emb EMB145 · Equipment/Furnishings Wiring
  > DURING CLIMB OUT, FLIGHT ATTENDANT NOTICED FUMES/STEAM FROM GALLEY HOT JUG AND SOCKET. NO DEFECTS NOTED. INSPECTED WIRING FOUND COFFEE RESIDUAL AT CONNECTION. CLEANED CONNECTION. REMOVED AND AND REPLACED 2 O-RING TERMINALS. OPS CHECKED HOT JUG. OPS CHECKED
- [SDR SIMA20160919003](https://openairdocs.org/sdr/SIMA20160919003.md): Frame · corroded · Sep 19, 2016 · N603KC · Emb EMB145LR · Fuselage Main, Frame
  > FRAME 65 IS CORRODED ABOVE CARGO DOOR GUIDE PLATE. REPAIRED THE FRAME IAW SRM 53-31-04, FIGURE 212.
- [SDR SIMA20160917003](https://openairdocs.org/sdr/SIMA20160917003.md): Battery Pack · inoperative · Sep 17, 2016 · N603KC · Emb EMB145LR · Emergency Lighting
  > GALLEY AREA EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK ASSEMBLY IAW AMM 33-50-04.
- [SDR SIMA20160913004](https://openairdocs.org/sdr/SIMA20160913004.md): Door Sill · corroded · Sep 13, 2016 · N603KC · Emb EMB145LR · Fuselage Miscellaneous Structure
  > CARGO LOWER DOOR SILL IS CORRODED. R & R THE DOOR SILL IAW SRM 51-40-02.
- [SDR SIMA20160912004](https://openairdocs.org/sdr/SIMA20160912004.md): Floor Support · corroded · Sep 12, 2016 · N603KC · Emb EMB145LR · Fuselage Miscellaneous Structure
  > LEFT CENTER AISLE FLOOR SUPPORT CORRODED BETWEEN FRAMES 58-59. R & R THE FLOOR SUPPORT IAW SRM 51-20-03, AND 51-40-02/06.
- [SDR SIMA20160910004](https://openairdocs.org/sdr/SIMA20160910004.md): Shear Tie · corroded · Sep 10, 2016 · N603KC · Emb EMB145LR · Fuselage Internal Mounting Structure
  > FRAME 65 SHEAR TIE CORRODED. REPAIRED THE SHEAR TIE IAW SRM 53-31-04, FIGURE 213.
- [SDR SIMA20160910006](https://openairdocs.org/sdr/SIMA20160910006.md): Bracket · corroded · Sep 10, 2016 · N603KC · Emb EMB145LR · Fuselage Miscellaneous Structure
  > TEE BRACKET AT FRAME 66 UNDER CARGO DOOR SILL IS CORRODED. REMOVED AND REPLACED THE DOOR SILL TEE BRACKET IAW SRM 51-40-02, 51-20-03
- [SDR SIMA20160910005](https://openairdocs.org/sdr/SIMA20160910005.md): Bracket · corroded · Sep 10, 2016 · N603KC · Emb EMB145LR · Fuselage Miscellaneous Structure
  > CARGO DOOR LOWER SILL TEE BRACKET AT FRAME 68 IS CORRODED. REMOVED AND REPLACED THE BRACKET IAW SRM 51-40-02, AND 51-20-03.
- [SDR SIMA20160821005](https://openairdocs.org/sdr/SIMA20160821005.md): Power Supply · inoperative · Aug 21, 2016 · N603KC · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHTS IN GALLEY AREA INOPERATIVE. REMOVED AND REPLACED THE NR 2 EMERGENCY LIGHT BATTERY SUPPLY IAW AMM 33-50-04. OPS CHECKED GOOD.
- [SDR SIMA20160821004](https://openairdocs.org/sdr/SIMA20160821004.md): Light · inoperative · Aug 21, 2016 · N603KC · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT AT 253CLC BEHIND THE EXIT SIGN INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT ASSY IAW AMM 33-50-08. OPS CHECKED GOOD.
- [SDR SIMA20160729005](https://openairdocs.org/sdr/SIMA20160729005.md): Flashlight · inoperative · Jul 29, 2016 · N603KC · Emb EMB145LR · Emergency Equipment
  > FORWARD F/A FLASHLIGHT NOT CHARGING. R & R FOWARD F/A FLASHLIGHT IAW AMM 33-50-16.
- [SDR SIMA20160720002](https://openairdocs.org/sdr/SIMA20160720002.md): Valve · malfunctioned · Jul 20, 2016 · N603KC · Emb EMB145LR · Cabin Pressure Control System
  > IN FLIGHT, ACFT PRESSURIZATION WOULD NOT STOP CLIMBING. CABIN WHENT AS HIGH AS 10,000 FT. AUTO MODE WAS CLIMMING AT 1,000 FT + MIN AND WOULD NOT STOP. AUTO MODE AND MANUAL MODES VIRTUALLY UNRESPONSIVE. R & R GROUND CONNECTION VALVE AND SEAL IAW AMM 21-22-0
- [SDR SIMA20160209002](https://openairdocs.org/sdr/SIMA20160209002.md): Battery · discharged · Feb 9, 2016 · N603KC · Emb EMB145LR · Emergency Lighting
  > LEFT EXTERIOR FWD OVERWING EMER LIGHT INOPERATIVE. R & R LT EXTERIOR FWD OVERWING EMER LIGHT BULB IAW AMM 33-50-10, NO FIX. R & R ASSEMBLY IAW AMM 33-50-10, NO FIX. R & R NR 1 EMER BATTERY 33-50-04-000-802-A & 33-50-04-400-802-A, BATTERY CHARGER IAW AMM 33-
- [SDR SIMA20160203001](https://openairdocs.org/sdr/SIMA20160203001.md): Actuator · failed · Feb 3, 2016 · N603KC · Emb EMB145LR · Drag Control Actuator
  > LEFT SPOILER NOT STOWING PROPERLY, IT LAGS BY = 5 SEC, SPOILER LEVER DISAGREE MSG. ACFT YAWED DRASTICALLY TO LT AS WE RECEIVED SPOILER LEVER DISAGREE MSG. R & R LT SPEED BRAKE ACTUATOR IAW AMM 27-62-02. OPERATIONS CHECKED GOOD, LEAK CHECKED GOOD.
- [SDR SIMA20160123002](https://openairdocs.org/sdr/SIMA20160123002.md): Power Supply · inoperative · Jan 23, 2016 · N603KC · Emb EMB145LR · Emergency Lighting
  > LEFT FWD FAIRING, NR 1 CEILING & MAIN DOOR EMER LIGHTS INOPERATIVE. R & R NR 1 BATTERY & POWER SUPPLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD. EMER LIGHTING BATTERY PN 2013-1A, SN 104542.
- [SDR SIMA20160123001](https://openairdocs.org/sdr/SIMA20160123001.md): Skin · cracked · Jan 23, 2016 · N603KC · Emb EMB145LR · Wing, Plate/Skin
  > RIGHT UPPER WING SKIN CRACKED AT GND SPOILER, CTR HINGE CUT OUT, 1.17 INCHES LONG. TRANSFERRED TO NRWC 603 MQT 02576. REPAIRED AREA IAW ERS-EM-57MR-569.
- [SDR SIMA20160114001](https://openairdocs.org/sdr/SIMA20160114001.md): Light · inoperative · Jan 14, 2016 · N603KC · Emb EMB145LR · Emergency Lighting
  > TWO STRIPS, CAPTAINS SIDE, EMER LIGHT INOPERATIVE ABOUT MIDWAY IN CABIN. OPERATIONS CHECK OF EMER LIGHTS IAW AMM 33-50-12, OPERATIONS CHECKED GOOD.
- [SDR SIMA20151010002](https://openairdocs.org/sdr/SIMA20151010002.md): Light · inoperative · Oct 10, 2015 · N603KC · Emb EMB145LR · Emergency Lighting
  > LEFT FWD WING EXTERIOR EMER LIGHT INOPERATIVE. R & R LT FWD WING EXTERIOR EMER LIGHT LAMP IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.
- [SDR SIMA20151010001](https://openairdocs.org/sdr/SIMA20151010001.md): Light · inoperative · Oct 10, 2015 · N603KC · Emb EMB145LR · Emergency Lighting
  > MAIN CABIN DOOR EMER LIGHT INOPERATIVE. R & R MAIN CABIN DOOR EMER LIGHT LAMP IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150917002](https://openairdocs.org/sdr/SIMA20150917002.md): Light · inoperative · Sep 17, 2015 · N603KC · Emb EMB145LR · Emergency Lighting
  > RIGHT WING EMER LIGHT INOPERATIVE. R & R RT WING EMER LIGHT ASSEMBLY IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150831001](https://openairdocs.org/sdr/SIMA20150831001.md): Light · inoperative · Aug 31, 2015 · N603KC · Emb EMB145LR · Emergency Lighting
  > RIGHT OVERWING EMER LIGHT INOPERATIVE. REPLACED RT OVERWING EMER LIGHT LAMP IAW AMM TASKS 33-50-10-000-801-A & 33-50-10-400-801-A. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150731003](https://openairdocs.org/sdr/SIMA20150731003.md): Light · inoperative · Jul 31, 2015 · N603KC · Emb EMB145LR · Emergency Lighting
  > LEFT EXTERIOR FORWARD EMERGENCY LIGHT INOPERATIVE. R & R LIGHT BULB FOR LEFT EXTERIOR FORWARD EMERGENCY LIGHT IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150408008](https://openairdocs.org/sdr/SIMA20150408008.md): Light · inoperative · Apr 8, 2015 · N603KC · Emb EMB145LR · Emergency Lighting
  > OVERWING LT AFT EMER LIGHT INOPERATIVE. R & R LT EXTERNAL EMER LIGHT LAMP ASSEMBLY IAW AMM 33-50-10. OPERATIONS CHECKED GOOD LT & RT EXTERNAL EMER LIGHTS.

Next page: https://openairdocs.org/aircraft/N603KC/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy