# Service difficulty reports: N618AE

A list on [N618AE](https://openairdocs.org/aircraft/N618AE.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Page 1 of 4 · 178 reports

- [SDR SIMA202210043001](https://openairdocs.org/sdr/SIMA202210043001.md): Lamp · inoperative · Oct 3, 2022 · N618AE · Emb EMB145LR · Emergency Lighting
  > RH OVERWING EMERGENCY LT INOP-C/A-RAR OVERWING EMERGENCY LIKGHT LAMP IAW EMB 145 AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.
- [SDR SIMA20220716001](https://openairdocs.org/sdr/SIMA20220716001.md): Light · inoperative · Jul 16, 2022 · N618AE · Emb ERJ170200LR · Emergency Lighting
  > LH OVER-WING EMERGENCY LIGHT INOP-C/A-RAR LH OVER-WING EMERGENCY LIGHT LAMP IAW AMM 33-50-07. OPS TEST GOOD AT THIS TIME
- [SDR SIMA20220410003](https://openairdocs.org/sdr/SIMA20220410003.md): None · inoperative · Apr 10, 2022 · N618AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY FLOOR LIGHT PROXIMITY STRIP INOP NEAR ROW 8A. ORIG LOGPAGE 4593164 ITEM 3 MEL 3323 - AUTH# 04-128-C.-C/A-REMOVED AND REPLACED PROXIMITY FLOOR STRIP 8A (EMERGENCY) IAW 145 AMM 33-50-08. OPC GOOD MEL RESTORED
- [SDR SIMA20220409003](https://openairdocs.org/sdr/SIMA20220409003.md): Battery · unserviceable · Apr 9, 2022 · N618AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT STRIP AT SEAT 8A AND 9A INOP SUSPECT #3 EMERGENCY POWER SUPPLY NEED REPLACEMENT-C/A-RAR #3 EMERGENCY POWER SUPPLY IAW AMM 33-50-04. OPERATIONAL CHECK GOOD.
- [SDR SIMA20220409002](https://openairdocs.org/sdr/SIMA20220409002.md): Lamp · inoperative · Apr 9, 2022 · N618AE · Emb EMB145LR · Emergency Lighting
  > L/H OVER WING EMERGENCY LIGHT INOP-C/A-RAR L/H OVER WING EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPERATIONAL CHECK GOOD.
- [SDR SIMA20220404002](https://openairdocs.org/sdr/SIMA20220404002.md): None · none · Apr 4, 2022 · N618AE · Emb EMB145LR · Wing Structure
  > RH AILERON O/B PCA ATTACHMENT TO AILERON FITTING, BUSHING IS MIGRATED AND LOOSE.(MAJOR REPAIR)-C/A-RAR RH AILERON PCA FITTING ASSY IAW EO-EM-27MR-112
- [SDR SIMA20220329001](https://openairdocs.org/sdr/SIMA20220329001.md): Lamp · inoperative · Mar 29, 2022 · N618AE · Emb EMB145LR · Emergency Lighting
  > RH OVER WING EMERGENCY LIGHT INOP-C/A-RAR RH OVER WING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. NO FIX. RAR RH OVER WING EMERGENCY LIGHT ASSY IAW EMB AMM 33-50-07-000-802-A AND 33-50-07-400-802-A. OPC GOOD. END.
- [SDR SIMA20220322001](https://openairdocs.org/sdr/SIMA20220322001.md): None · none · Mar 22, 2022 · N618AE · Emb EMB145LR · Cabin Cooling System
  > PACK #1 + PACK #2 CLOSED EICAS MESSAGE IN FLIGHT RAN QRH AND AIRCRAFT DID NOT PRESSURIZE.DECLARED EMG TROUBLE WITH CABIN PRESSURE PACK #1 + PACK #2 CLOSED EICAS MESSAGE IN FLIGHT RAN QRH AND AIRCRAFT DID NOT PRESSURIZE.DECLARED EMG TROUBLE WITH CABIN PRESSURE
- [SDR SIMA20211124002](https://openairdocs.org/sdr/SIMA20211124002.md): None · none · Nov 24, 2021 · N618AE · Emb EMB145LR · Emergency Lighting
  > FA AFT EMERGENCY FLASHLIGHT MISSING-C/A-FLIGHT CREW PLACARDED AFT FLIGHT ATTENDANT EMERGENCY FLASHLIGHT AUTH 110346M-C REF 25-32 MOC 630997
- [SDR SIMA20211117001](https://openairdocs.org/sdr/SIMA20211117001.md): None · none · Nov 17, 2021 · N618AE · Emb EMB145LR · Emergency Lighting
  > RH EXTERIOR OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH EXTERIOR OVERWING EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10, NO FIX. RAR #4 EMERGENCY BATTERY PACK AND CHARGER IAW EMB 145 AMM 33-50-10. NO FIX. REMOVED RH EXTERIOR OVERWING EMERGENCY LIGHT ASSY IAW EMB
- [SDR SIMA20211006001](https://openairdocs.org/sdr/SIMA20211006001.md): None · none · Oct 6, 2021 · N618AE · Emb EMB145LR · Emergency Equipment
  > MEL 2532 - AUTH# 100085M-C FA FWD FLASHLIGHT INOP LOGPAGE: 4715664-C/A-RAR FA FWD FLASHLIGHT ASSY IAW EMB145 AMM 33-50-16. OPC GOOD. MEL 25-32 AUTH# 100085M-C RESTORED.
- [SDR SIMA202109054001](https://openairdocs.org/sdr/SIMA202109054001.md): Light · inoperative · Sep 4, 2021 · N618AE · Emb EMB145LR · Emergency Lighting
  > SEAT 12A OVERWING EMERGENCY LIGHT INOP-C/A-RAR SEAT 12A OVERWING EMERGENCY LIGHT IAW EMB 145 AMM 33-50-07. OPS CHECK GOOD.
- [SDR SIMA20210516004](https://openairdocs.org/sdr/SIMA20210516004.md): Contactor · burned · May 16, 2021 · N618AE · Emb EMB145LR · Air Distribution Fan
  > STRONG ELEC FUME SMELL WHILE DECENDING THROUGH FL240 CAME AND WENT FOR THE REMAINDEROF FLIGHT.-C/A- FOUND LH RECIRCULATION FAN CONTACTOR BURNED. RAR RECIRCULATION FAN CONTACTOR K0189 AND FUSE IAW AMM 21-24-03. PERFORMED CHECK OF THE AIRCONDITIONING DISTRIBUT
- [SDR SIMA20201106002](https://openairdocs.org/sdr/SIMA20201106002.md): Stringer · corroded · Nov 6, 2020 · N618AE · Emb EMB145LR · Fuselage Main, Longeron/Stringer
  > CORROSION ON STR 17R BETWEEN FR 19A AND FR 20. C/A: REMOVED AND REPLACED DAMAGED PORTION OF STRINGER 17R BETWEEN FR 16-24, IAW EMB 145 SRM 53-00-03 ITEM 7.
- [SDR SIMA20201101003](https://openairdocs.org/sdr/SIMA20201101003.md): Valve · corroded · Nov 1, 2020 · N618AE · Emb EMB145LR · Waste Disposal System
  > SSI 53-20-29 TOILET WASTE VALVE BUCKET IS CORRODED. C/A: REMOVED AND REPLACED WASTE VALVE CUP (BUCKET), IAW EMB 145 SRM 51-40-02 AND EMB 145 SRM 51-20-03.
- [SDR SIMA20201031003](https://openairdocs.org/sdr/SIMA20201031003.md): Profile · corroded · Oct 31, 2020 · N618AE · Emb EMB145LR · Emergency Exits
  > SSI 52-21-06 CORROSION ON LT PASSENGER ESCAPE HATCH LOWER L PROFILE. C/A: REMOVED AND REPLACED LT PASSENGER ESCAPE HATCH LOWER L PROFILE, IAW EMB145 SRM 51-20-03, EMB 145 SRM 51-40-02 AND EMB 145 SRM 51-20-01.
- [SDR SIMA20201028002](https://openairdocs.org/sdr/SIMA20201028002.md): Door Sill · corroded · Oct 28, 2020 · N618AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > SSI 53-30-48: AIRCRAFT STRUCTURE CARGO DOOR LOWER CUTOUT CORRODED, MARKED. C/A: REMOVED AND REPLACED CARGO DOOR LOWER CUTOUT (SILL), IAW EMB 145 SRM 51-40-02.
- [SDR SIMA20201028001](https://openairdocs.org/sdr/SIMA20201028001.md): Door Sill · cracked · Oct 28, 2020 · N618AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > FRAME 66 CRACKED AT CARGO DOOR SILL ON T BRACKET. C/A: REMOVED AND REPLACED FR 66 LOWER SECTION, IAW EMB 145 SRM 51-40-02.
- [SDR SIMA20201026004](https://openairdocs.org/sdr/SIMA20201026004.md): Skin · damaged · Oct 26, 2020 · N618AE · Emb EMB145LR · Fuselage Main, Plate/Skin
  > EXTERNAL FUSELAGE SKIN HAS A CREASE BETWEEN FR 73-74 AND STGR 12L-13L. C/A: PERFORMED A TYPE A SKIN DOUBLER REPAIR AT CEASE BETWEEN FR 73-74 STGR 12L-13L, IAW EMB 145 SRM 53-31-01RE ITEM 2 FIGURE 201 SHEET 1.
- [SDR SIMA20201026003](https://openairdocs.org/sdr/SIMA20201026003.md): Profile · corroded · Oct 26, 2020 · N618AE · Emb EMB145LR · Cargo/Baggage Doors
  > CORROSION ON CARGO DOOR LOWER LT PROFILE. C/A: R & R CARGO DOOR LOWER LT PROFILE, IAW EMB 145 SRM 51-20-03 AND SRM 51-40-02.
- [SDR SIMA20201025004](https://openairdocs.org/sdr/SIMA20201025004.md): Profile · corroded · Oct 25, 2020 · N618AE · Emb EMB145LR · Emergency Exits
  > CORROSION ON RT PASSENGER ESCAPE HATCH LOWER LT PROFILE. C/A: R & R RT PASSENGER ESCAPE HATCH LOWER LT PROFILE, IAW EMB 145 SRM 51-20-03, 51-40-02, AND 51-20-01.
- [SDR SIMA20201025003](https://openairdocs.org/sdr/SIMA20201025003.md): Skin · gouged · Oct 25, 2020 · N618AE · Emb EMB145LR · Cargo/Baggage Doors
  > CARGO DOOR INNER WEBBING (SKIN) HAS 3 GOUGES AT PREVIOUS REPAIR. C/A: RE-ACCOMPLISHED 2 EACH REPAIRS ON THE CARGO DOOR INNER LOWER SKIN, IAW EMB 145 SRM 52-30-01 AND ETN-EM-52-043.
- [SDR SIMA20201025002](https://openairdocs.org/sdr/SIMA20201025002.md): Door Frame · corroded · Oct 25, 2020 · N618AE · Emb EMB145LR · Fuselage Main, Structure
  > RT OVER WING HATCH LOWER FRAME IS CORRODED AROUND 2 FASTENER HOLES ON AFT END. C/A: R & R RT PASSENGER ESCAPE HATCH LOWER LT PROFILE BEAM, IAW EMB 145 SRM 51-20-03, 51-40-02 AND 51-20-01.
- [SDR SIMA20201023004](https://openairdocs.org/sdr/SIMA20201023004.md): Shear Tie · corroded · Oct 23, 2020 · N618AE · Emb EMB145LR · Fuselage Internal Mounting Structure
  > CARGO DOOR CUTOUT FR 65 SHEAR CLIP CORRODED. C/A: R & R CARGO DOOR CUTOUT FR 65 SHEAR CLIP, IAW EMB 145 SRM 53-31-04.
- [SDR SIMA20201023003](https://openairdocs.org/sdr/SIMA20201023003.md): Bracket · corroded · Oct 23, 2020 · N618AE · Emb EMB145LR · Fuselage Main, Attach Fittings
  > FR 65 T BRACKET CORRODED. C/A: R & R FR 65 T BRACKET, IAW EMB 145 SRM 51-40-02.
- [SDR SIMA20201020003](https://openairdocs.org/sdr/SIMA20201020003.md): Yoke · cracked · Oct 20, 2020 · N618AE · Emb EMB145LR · Engine Mount Section
  > RT ENGINE FWD YOKE STRUCTURE, FWD OUTBOARD LOWER SIDE IS CRACKED. C/A: R & R RT ENGINE FWD LOWER YOKE FITTING, IAW ERS-EM-54MR-698.
- [SDR SIMA20201007001](https://openairdocs.org/sdr/SIMA20201007001.md): Rib · cracked · Oct 7, 2020 · N618AE · Emb EMB145LR · Wing, Rib/Bulkhead
  > LT WING RIB 21 IS CRACKED INSIDE THE PCA PANEL. C/A: PERFORMED REPAIR AT LT WING RIB 21 INSIDE THE PCA PANEL, IAW EMB 145 SRM 57-50-07 ITEM 4 FIGURE 203.
- [SDR SIMA20201002006](https://openairdocs.org/sdr/SIMA20201002006.md): Bulb · inoperative · Oct 2, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT ON RIGHT WING OVERHEAD PANEL INOPERABLE. C/A COMPLETE: R & R EMERGENCY LIGHT BULB ON RIGHT WING OVERHEAD PANEL, IAW EMB 145 AMM 33-50-10. OPERATIONAL CHECK OK.
- [SDR SIMA20201002007](https://openairdocs.org/sdr/SIMA20201002007.md): Connector · missing · Oct 2, 2020 · N618AE · Emb EMB145LR · Light System Wiring
  > NR 1 AND NR 2 EMERGENCY FLOOR LIGHT STRIPS ARE MISSING CONNECTORS ON A/C SIDE. C/A COMPLETE: INSTALLED NEW AND SERVICEABLE CONNECTORS AT NR 1 AND NR 2 EMERGENCY FLOOR LIGHT STRIPS ON A/C SIDE, IAW EMB 145 SWPM 20-21-00. SEE BOW347724 TASK NR 1 FOR OPERATIONA
- [SDR SIMA20201002005](https://openairdocs.org/sdr/SIMA20201002005.md): Connector · broken · Oct 2, 2020 · N618AE · Emb EMB145LR · Light System Wiring
  > NR 1 EMERGENCY LIGHT STRIP CONNECTOR ON A/C SIDE IS BROKEN. C/A COMPLETE: R & R NR 1 EMERGENCY LIGHT STRIP CONNECTOR ON A/C SIDE, IAW EMB 145 SWPM 20-21-00. INSTALLED NR 1 EMERGENCY LIGHT STRIP, IAW EMB 145 AMM 30-50-12. OPERATIONS CHECK GOOD, IAW EMB 145 A
- [SDR SIMA20200917004](https://openairdocs.org/sdr/SIMA20200917004.md): Light · inoperative · Sep 17, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > DURING PS-1 CHECK, FOUND LT ABOVE WING EXTERIOR EMERGENCY LIGHT INOP. C/A: R & R EXTERIOR EMERGENCY LIGHT ASSEMBLY, IAW AMM 33-50-10. OPERATIONAL CHECK GOOD. NO DEFECTS NOTED AT THIS TIME.
- [SDR SIMA202008164001](https://openairdocs.org/sdr/SIMA202008164001.md): Bulb · inoperative · Aug 14, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > DURING PS-1 CHECK FOUND R/H O/W EMERGENCY LIGHT INOP-C/A-RAR R/H O/W EMERGENCY LIGHT BULB IAW EMB-145 AMM 33-50-10
- [SDR SIMA202007232003](https://openairdocs.org/sdr/SIMA202007232003.md): Connector · detached · Jul 22, 2020 · N618AE · Emb EMB145LR · Light System Wiring
  > LEFT EXTERIOR OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. R & R LT EXTERIROR OVERWING EMERGENCY EXIT LIGHT BULB IAW AMM 33-50-10. OPS CHECK FAILED. REMOVED ACESS PANEL 195AL AND FOUND THE CONNECTOR PLUG DETACHED FROM LT EXTERIOR OVERHEAD LIGHT ASSY. CONNECTED
- [SDR SIMA202006109003](https://openairdocs.org/sdr/SIMA202006109003.md): Flapper Valve · faulty · Jun 9, 2020 · N618AE · Emb EMB145LR · Cabin Pressure Control System
  > SUPPLEMENTAL LOST PRESSURIZATION AT APPROX 13,500 COULD CABIN ALT (2000) FEET WAS THE BEST. DEFER AUTO PRES M PROCEDURES C/W MANUAL PRESS OPS CHECK GOOD IAW AMM 21-31-00 MEL 21-17 AUTH 060107DM-C MOC 607038. REMOVED AND REPLACED FLAPPER VALVE IAW AMM 21-22-0
- [SDR SIMA2020060129003](https://openairdocs.org/sdr/SIMA2020060129003.md): Battery · discharged · May 29, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > LEFT EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED NR 4 EMERGENCY BATTERY INVERTER IAW AMM 33-50-11-000-801-A AND 33-50-11-400-801-A. NO FIX, REMOVED AND REPLACED NR 3 EMERGENCY BATTERY IAW AMM 33-50-04-000-801-A, 33-50-04-400-801-A, 33-50-04-000-802-
- [SDR SIMA2020060129001](https://openairdocs.org/sdr/SIMA2020060129001.md): Light · inoperative · May 29, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > LEFT AFT OVERWING EMERGENCY LIGHT. REMOVED AND REPLACED LT AFT OVERWING EMERGENCY LIGHT IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A, NO FIX.. REMOVED AND REPLACED LT AFT OVERWING EMERGENCY LIGHT ASSEMBLY IAW 33-50-07-000-802-A AND 33-50-07-400-802-A.
- [SDR SIMA2020060129002](https://openairdocs.org/sdr/SIMA2020060129002.md): Battery · discharged · May 29, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > RIGHT EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED NR 4 EMERGENCY BATTERY INVERTER IAW AMM 33-50-11-000-801-A AND 33-50-11-400-801-A, NO FIX. REMOVED AND REPLACED NR 3 EMERGENCY BATTERY IAW AMM 33-50-04-000-801-A, 33-50-04-400-801-A, 33-50-04-000-80
- [SDR SIMA202005186001](https://openairdocs.org/sdr/SIMA202005186001.md): Charger · inoperative · May 16, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > INTERIOR RH EXIT EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED #2 BATTERY CHARGER ASSEMBLY, IAW AMM 33-50-04, OPERATIONS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 13247
- [SDR SIMA202003254001](https://openairdocs.org/sdr/SIMA202003254001.md): Light · inoperative · Mar 24, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > RIGHT HAND OVERWING EXIT LIGHT INOP-C/A-REMOVED AND REPLACED LAMP FOR THE RH OVERWING EMERGENCY EXIT LIGHT IAW AMM 33-50-07. OPS CHECK GOOD
- [SDR SIMA202003097001](https://openairdocs.org/sdr/SIMA202003097001.md): Battery · discharged · Mar 7, 2020 · N618AE · Emb EMB145LR · Emergency Lighting
  > LH AND RH OVER WING EMERGENCY LIGHTS WILL NOT ILLUMINATE-C/A-RE-LAMPED RH OVER WING EMERGENCY LIGHT NO FIX. RAR BATTERY AND CHARGER #4 IAW WC 33-700-19 OPC CHECK GOOD
- [SDR SIMA202001275002](https://openairdocs.org/sdr/SIMA202001275002.md): Brake · lack of lube · Jan 25, 2020 · N618AE · Emb EMB145LR · Landing Gear Brake System
  > PARKING BRAKE HARD TO SET.-C/A-CLEANED AND LUBRICATED PARKING BRAKE IAW EMB 145MM 32-44-10. OPS CK GOOD.
- [SDR SIMA2020012019004](https://openairdocs.org/sdr/SIMA2020012019004.md): Smoke Detector · false indication · Jan 19, 2020 · N618AE · Emb EMB145LR · Smoke Detection
  > CARGO SMOKE INDICATION AT PARKING BRAKE SET CFR RESPONDED. NO EVIDENCE OF SMOKE DETECTED. R & R THE SMOKE DETECTORS NR 1 AND 2 IAW AMM 26-15-01. OPS CHECKED GOOD IAW AMM 26-15-00.
- [SDR SIMA202001198001](https://openairdocs.org/sdr/SIMA202001198001.md): Cradle · broken · Jan 18, 2020 · N618AE · Emb EMB145LR · Emergency Equipment
  > REAR FLASHLIGHT HOLDER IN CABIN BROKEN. REMOVED AND REPLACED AFT FLASHLIGHT ASSY IAW AMM 33-50-16. OPS CHECKED GOOD.
- [SDR SIMA201912164001](https://openairdocs.org/sdr/SIMA201912164001.md): Line · damaged · Dec 14, 2019 · N618AE · Emb EMB145LR · Hydraulic System, Main
  > HYD SYS 1 LO QTY RETURNED TO BASE TRANSFER TO NRWC# 618-MIA-03437-C/A-REPAIRED HYD RETURNED LINE ITEM#1 FIG 17 ON IPC 29-11-00 LEAK CHECK GOOD NO DISCREPANCIES NOTED IAW STANDARD PRACTICE 20-10-03
- [SDR SIMA20190914004](https://openairdocs.org/sdr/SIMA20190914004.md): Inverter · inoperative · Sep 14, 2019 · N618AE · Emb EMB145LR · Emergency Lighting
  > RT UPPER EMERGENCY EXIT LIGHT AT ROW 12C INOP. C/A-REMOVED AND R EPLACED EMERGENCY LIGHT DC/AC INVERTER IAW AMM 33-50-11 OPC GOOD.
- [SDR SIMA201906173004](https://openairdocs.org/sdr/SIMA201906173004.md): Control Module · odor · Jun 13, 2019 · N618AE · Emb EMB145LR · Passenger Compartment Lighting
  > FA REPORTS PANGENT SMELL COMING FROM SERVICE DOOR BACK TO ROW 6-C/A-FOUND CABIN LIGHT CONTROL MODULE TO BE THE SOCRCE REMOVED AND REPLACED CONTROL MODULE ASSEMBLY IAW 145 AMM 33-21-01 OPS-CHECK GOOD NO FURTHER SMELL DETECTED
- [SDR SIMA2019040104](https://openairdocs.org/sdr/SIMA2019040104.md): Connector · broken · Mar 27, 2019 · N618AE · Emb EMB145LR · Light System Wiring
  > DURING INSTALLATION OF FLOOR PANEL 261BF FOUND FLOOR PROXIMITY STRIP LIGHT WIRE CONNECTOR BROKEN.-C/A-INSTALLED MISSING SPLICE MALE CONNECTOR IN FLOOR PROXIMITY STRIP LIGHT #8 IAW EMB 145 AMM 20-00-03. OPS CHECK GOOD IAW EMB145 AMM 33-50-12
- [SDR SIMA20190220001](https://openairdocs.org/sdr/SIMA20190220001.md): Light · inoperative · Feb 20, 2019 · N618AE · Emb EMB145LR · Emergency Lighting
  > LT OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND AMM 33-50-10-400-801-A. OPS CHECK GOOD. NO MORE DEFECTS NOTED AT THIS TIME.
- [SDR SIMA201812065001](https://openairdocs.org/sdr/SIMA201812065001.md): Lamp · inoperative · Dec 5, 2018 · N618AE · Emb EMB145LR · Emergency Lighting
  > LH EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH EMERGENCY LIGHT IAW AMM 33-50-10 OPS CHECK GOOD.
- [SDR SIMA201811196001](https://openairdocs.org/sdr/SIMA201811196001.md): Warning Light · false activation · Nov 16, 2018 · N618AE · Emb EMB145LR · Trailing Edge Flap Control System
  > FLAP LOW SPEED ADVISORYIN CRUISE AT FL 370 NO FLAPS SELECTED LEVER NOT MOVED MECH FLAP WARNING AT ALTITUDE AND POSS AIRSPEED UNRELIABLE EMERGENCY DECLARED.-C/A-CHECKED CMC MESSAGES. FOUND 1 OCCURANCE OF MESSAGE "FLAP FEEDBACK POS FAIL" T/SHOT PER FIM TASK 27-5

Next page: https://openairdocs.org/aircraft/N618AE/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N618AE' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N618AE/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.