- [SDR SIMA20221029001](https://openairdocs.org/sdr/SIMA20221029001.md): Lamp · inoperative · Oct 29, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > LH OVERWING EMERGENCY LIGHT INOP-C/A-RAR LH EMERGENCY OVERWING LAMP WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. RAR LH EMERGENCY OVERWING LIGHT ASSEMBLY WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC G
- [SDR SIMA20221002002](https://openairdocs.org/sdr/SIMA20221002002.md): Lamp · inoperative · Oct 2, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > LH OVERWING EMERGENCY LIGHT INOP-C/A-RAR LH OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-07. OPC GOOD
- [SDR SIMA20220818001](https://openairdocs.org/sdr/SIMA20220818001.md): Lamp · inoperative · Aug 18, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > DURING PS-2 FOUND L/H EXTERIOR OVERWING EMERGENCY LIGHT TO BE INOP-C/A-RAR L/H EXTERIOR OVERWING EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD NO FURTHER DEFECTS NOTED.
- [SDR SIMA20220727002](https://openairdocs.org/sdr/SIMA20220727002.md): Lamp · inoperative · Jul 27, 2022 · N623AE · Emb ERJ170200LR · Emergency Lighting
  > LH OVERWING EMERGENCY LIGHT INOP-C/A-RAR LH OVERWING EMERGENCY LIGHT LAMPIAW AMM 33-50-10. OPS CHECK GOOD.
- [SDR SIMA20220720001](https://openairdocs.org/sdr/SIMA20220720001.md): Battery · inoperative · Jul 20, 2022 · N623AE · Emb ERJ170200LR · Emergency Lighting
  > REF LGPG 4785740 ITEM 2 MAIN DOOR EXTERNAL EMERGENCY LIGHT INOP. MEL 33-22 AUTH 070292D-C.-C/A-RAR MAIN DOOR EXTERNAL EMERGENCY LIGHT LIGHT ASSY. IAW 33-50-10. OPS CHECK GOOD. MEL ITEM RESTORED.
- [SDR SIMA20220425001](https://openairdocs.org/sdr/SIMA20220425001.md): None · none · Apr 25, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > EMERGENEY LIGHT FLOOR STRIP AT SEATS 8A AND 9A HAS BROKEN WIRE.-C/A-REPLACED SOCKET ON WIRE W192-8702-22 FOR SPLICE SP9102 IAW WM 33-50-50 AND SWPM 20-00-03 AND 20-21-00.
- [SDR SIMA20220415001](https://openairdocs.org/sdr/SIMA20220415001.md): Lamp · inoperative · Apr 15, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > MAIN DOOR EMERGENCY LIGHT INOP-C/A-RAR MAIN DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. END.
- [SDR SIMA20220314001](https://openairdocs.org/sdr/SIMA20220314001.md): Cradle · broken · Mar 14, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > FLT DECK/ATTENDANT EMERGENCY FLASHLIGHT/HOLDER FWD FA FLASHLIGHT HOLDER INOP-C/A-RAR FWD FA EMERGENCY FLASHLIGHT BRACKET IAW AMM 33-50-16. OPS CHECK GOOD. MEL RESTORED.
- [SDR SIMA20220312002](https://openairdocs.org/sdr/SIMA20220312002.md): Cradle · broken · Mar 12, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > FA EMERGENCY FLASHLIGHT BRACKET BROKE-C/A-DEFERRED FWD FA EMERGENCY FLASHLIGHT HOLDER ASSY. BROKEN BRACKET CLIP REMOVED. EQUIVALENT FLASHLIGHT PROVIDED. MTX ACTION C/W
- [SDR SIMA20220109001](https://openairdocs.org/sdr/SIMA20220109001.md): None · none · Jan 9, 2022 · N623AE · Emb EMB145LR · Emergency Lighting
  > MAIN DOOR EMERGENCY LIGHT INOP-C/A-RAR MAIN DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.
- [SDR SIMA20211206002](https://openairdocs.org/sdr/SIMA20211206002.md): None · none · Dec 6, 2021 · N623AE · Emb EMB145LR · Emergency Lighting
  > AFT CABIN EMERGENCY FLASHLIGHT CRACKED-C/A-RAR AFT CABIN EMERGENCY FLASHLIGHT HOLDING CLAMP IAW ASTRONICS DME CMM 25-60-14.
- [SDR SIMA20211023002](https://openairdocs.org/sdr/SIMA20211023002.md): None · none · Oct 23, 2021 · N623AE · Emb EMB145LR · Emergency Lighting
  > TDMI 623T3367 LH WTFF EMERGENCY LIGHT HOUSING LENS MISSING LOWER SCREWS/NUT PLATES DAMAGED @ 500FC ERS-EM-33DF-035 OPS PTC-C/A-RAR LH OVERWING EMERGENCY LIGHT ASSEMBLY IAW EMB AMM 33-50-07-000-802-A AND 33-50-07-400-802-A AND ERS-EM-33DF-035 OPS PT C. OPC GOOD
- [SDR SIMA20210908004](https://openairdocs.org/sdr/SIMA20210908004.md): Display · failed · Sep 8, 2021 · N623AE · Emb EMB145LR · Central Computers
  > EICAS WENT BLANK FOR 3 TO 5 SECONDS. SMELLED BURNING ELECTRICAL SMELL ON PRIOR FLIGHT-C/A-RAR EICAS IAW E-145 AMM 34-22-01. OPERATIONAL CHECK GOOD. RAR EICAS BEZEL REF. 34-22-01. FOUND ODOR COMING FROM OLD UNIT. ODOR NO LONGER FOUND IN COCKPIT. A/C OKAY FOR SE
- [SDR SIMA20210718002](https://openairdocs.org/sdr/SIMA20210718002.md): Light · inoperative · Jul 18, 2021 · N623AE · Emb EMB145LR · Emergency Lighting
  > OVER THE WING LH EMERGENCY LIGHT INOP-C/A-R&R LH EMERGENCY LAMP IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD
- [SDR SIMA20210629002](https://openairdocs.org/sdr/SIMA20210629002.md): Proximity Switch · failed · Jun 29, 2021 · N623AE · Emb EMB145LR · Emergency Lighting
  > DURING REMOVE FLOOR PANEL 251HF, EMERGENCY FLOOR PROXIMITY STRIP LIGHT #7 SPLICE BROKEN OFF.-C/A-RAR EMERGENCY FLOOR PROXIMITY STRIP LIGHT #7 REF AMM 33-50-12. OPC GOOD.
- [SDR SIMA20210614002](https://openairdocs.org/sdr/SIMA20210614002.md): Brake Sys · unknown · Jun 14, 2021 · N623AE · Emb EMB145LR · Landing Gear Brake System
  > MECH / BRAKE DEGRADE, EMERGENCY DECLARED- BRAKE DEGRADED ON GEAR EXTENSION. C/W FIM TASK 32-41-00 FOUND TO BE A TRANSATORY CONDITION ON BRAKE SYSTEM, NO CMC FAULT FOUND A/C OK FOR SERVICE
- [SDR SIMA20210522001](https://openairdocs.org/sdr/SIMA20210522001.md): Cradle · broken · May 22, 2021 · N623AE · Emb EMB145LR · Emergency Equipment
  > FWD FA EMERGENCY FLASHLIGHT HOLDER BROKEN-C/A-RAR FWD FA EMERGENCY FLASHLIGHT ASSEMBLY IAW ETN-EM-33-059
- [SDR SIMA20210328003](https://openairdocs.org/sdr/SIMA20210328003.md): Unknown · odor · Mar 28, 2021 · N623AE · Emb EMB145LR · Air Distribution System
  > SMOKE/BURNING ODOR (ELEC) IN COCKPIT-C/A-T/S BURNING SMELL IN CKPT PER EMB 145 FIM 21-20-00. SMELL STILL PERSISTS.
- [SDR SIMA20201214001](https://openairdocs.org/sdr/SIMA20201214001.md): Lamp · inoperative · Dec 14, 2020 · N623AE · Emb EMB145LR · Emergency Lighting
  > FURTHEST AFT CABIN CEILING EMERGENCY LIGHT INOPERABLE. C/A: R & R FURTHEST AFT CABIN CEILING EMERGENCY LIGHT LAMP, IAW EMB 145 AMM 33-50-08. OPERATIONS CHECK GOOD. NO FURTHER DEFECTS NOTED.
- [SDR SIMA20201204002](https://openairdocs.org/sdr/SIMA20201204002.md): Wire · broken · Dec 4, 2020 · N623AE · Emb EMB145LR · Light System Wiring
  > FOUND NR 3 EMERGENCY FLOOR PROXIMITY LIGHT DAMEGED (WIRE BROKEN) DURING REMOVAL OF GASPER FAN. C/A: R & R NR 3 EMERGENCY FLOOR PROXIMITY LIGHT, IAW EMB 145 AMM 33-50-12. OPERATIONS CHECK GOOD.
- [SDR SIMA20200928003](https://openairdocs.org/sdr/SIMA20200928003.md): Flange · gouged · Sep 28, 2020 · N623AE · Emb EMB145LR · Wing, Attach Fittings
  > RT WING TIP ATTACHMENT LOWER FLANGE IS GOUGED. C/A: REMOVED AND REPLACED RT WING TIP ATTACHMENT FLANGE, IAW EMB 145 SRM 51-40-02.
- [SDR SIMA20200928002](https://openairdocs.org/sdr/SIMA20200928002.md): Support · corroded · Sep 28, 2020 · N623AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > TOILET WASTE VALVE SUPPORT (LAV BUCKET) IS CORRODED. C/A: REMOVED AND REPLACED TOILET WASTE VALVE SUPPORT, IAW EMB 145 SRM 51-40-02.
- [SDR SIMA20200926005](https://openairdocs.org/sdr/SIMA20200926005.md): Frame · cracked · Sep 26, 2020 · N623AE · Emb EMB145LR · Fuselage Main, Frame
  > FRAME 73 IS CRACKED BETWEEN STRINGERS 16R-17R. C/A: REMOVED AND REPLACED LOWER SECTION OF FRAME 73, IAW EMB 145 SRM 51-40-02.
- [SDR SIMA20200926006](https://openairdocs.org/sdr/SIMA20200926006.md): Floor Support · corroded · Sep 26, 2020 · N623AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > LT OMEGA BEAM IS CORRODED AT FR 20. REPAIRED LT OMEGA BEAM, IAW EMB 145 SRM 53-00-10RE.
- [SDR SIMA20200926004](https://openairdocs.org/sdr/SIMA20200926004.md): Door · corroded · Sep 26, 2020 · N623AE · Emb EMB145LR · Emergency Exits
  > LT OVERWING EXIT LOWER EDGE IS CORRODED AROUND AND UNDER FWD AND AFT BLACK TEFLON PADS. C/A: REMOVED AND REPLACED LT OVERWING EXIT LOWER PROFILE, IAW EMB 145 SRM 51-10-02.
- [SDR SIMA20200926003](https://openairdocs.org/sdr/SIMA20200926003.md): Door Frame · corroded · Sep 26, 2020 · N623AE · Emb EMB145LR · Fuselage Main, Structure
  > RT OVERWING EXIT LOWER EDGE IS CORRODED AROUND AND UNDER FWD AND AFT BLACK TEFLON PADS. C/A: REMOVED AND REPLACED RT OVERWING EXIT LOWER PROFILE, IAW EMB 145 SRM 51-10-02.
- [SDR SIMA20200926002](https://openairdocs.org/sdr/SIMA20200926002.md): Frame · cracked · Sep 26, 2020 · N623AE · Emb EMB145LR · Fuselage Main, Frame
  > FR 72 IS CRACKED IN UPPER RADIUS BETWEEN STGR 16L-17L. C/A: REMOVED AND REPLACED LOWER SECTION OF FR 72, IAW EMB 145 SRM 51-40-02.
- [SDR SIMA20200831003](https://openairdocs.org/sdr/SIMA20200831003.md): Connector · broken · Aug 31, 2020 · N623AE · Emb EMB145LR · Light System Wiring
  > NR 6 EMERGENCY LIGHT STRIP WIRE CONNECTOR BROKEN UNDER FLOOR. C/A COMPLETE: REPAIRED NR 6 EMERGENCY LIGHT STRIP CONNECTOR, IAW EMB-145 SWPM 20-50-01. SEE NRTC E810792 FOR OPERATIONS CHECK
- [SDR SIMA20200831004](https://openairdocs.org/sdr/SIMA20200831004.md): Wire Harness · damaged · Aug 31, 2020 · N623AE · Emb EMB145LR · Emergency Lighting
  > PAX DOOR EMERGENCY LIGHT INOPERABLE. C/A COMPLETE: REPAIRED THE PASSENGER DOOR EMERGENCY LIGHT INDICATING HARNESS, IAW EMB-145 SWPM 20-21-00 S/N 2890B. OPERATIONS CHECKS GOOD, IAW EMB145 AMM 33-50-00.
- [SDR SIMA20200831005](https://openairdocs.org/sdr/SIMA20200831005.md): Battery Pack · inoperative · Aug 31, 2020 · N623AE · Emb EMB145LR · Emergency Lighting
  > CEILING PANEL 233 BLC EMERGENCY LIGHT INOPERABLE. C/A COMPLETE: REMOVED AND REPLACED NR 1 EMERGENCY LIGHT BATTERY AND CHARGING ASSEMBLY, IAW ENVOY WORK CARD 33-700-19. SEE NRTC E819046 FOR FNC CHECK.
- [SDR SIMA20200831002](https://openairdocs.org/sdr/SIMA20200831002.md): Connector · broken · Aug 31, 2020 · N623AE · Emb EMB145LR · Light System Wiring
  > NR 2 EMERGENCY LIGHT STRIP WIRE CONECTOR BROKEN UNDER FLOOR. C/A COMPLETE: REPAIRED NR 2 EMERGENCY LIGHT STRIP CONNECTOR, IAW EMB-145 SWPM 20-50-01. SEE NRTC E810792 FOR OPERATIONS CHECK.
- [SDR SIMA20200813001](https://openairdocs.org/sdr/SIMA20200813001.md): Cover · loose · Aug 13, 2020 · N623AE · Emb EMB145LR · Emergency Lighting
  > LH AFT OVER WING EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE-C/A-REMOVED AND REPLACED LH AFT OVER WING EMERGENCY EXIT LIGHT BULB IAW AMM 33-50-10. OPS CHECK GOOD.
- [SDR SIMA202003028004](https://openairdocs.org/sdr/SIMA202003028004.md): Light · inoperative · Feb 28, 2020 · N623AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT STRIPS 2 AND 3 ON CABIN FLOOR ARE INOP-C/A-AFTER INSTALLATION OF THE EMERGENCY EQUIPMENT STOWAGE WHICH CONTAINS THE EMERGENCY LIGHT SWITCH C/W OPERATIONAL CHECK OF THE EMERGENCY STOWAGE IAW AMM 33-50-00. OPS CHECK GOOD.
- [SDR SIMA202002187001](https://openairdocs.org/sdr/SIMA202002187001.md): Wire · broken · Feb 17, 2020 · N623AE · Emb EMB145LR · Light System Wiring
  > FOUND WIRE BROKEN ON #3 FLOOR EMERGENCY LIGHT STRIP-C/A-REMOVED AND REPLACED #3 FLOOR EMERGENCY LIGHT STRIP IAW AMM 33-50-12. OPC GOOD
- [SDR SIMA2019112516004](https://openairdocs.org/sdr/SIMA2019112516004.md): Skin · cracked · Nov 16, 2019 · N623AE · Emb EMB145LR · Fuselage Main, Plate/Skin
  > FUSELAGE CRACK BETWEEN FO WINDSHIELD AND DV WINDOW-C/A-REPAIRED UPPER SKIN PANEL I/A/W ENVOY ERS-EM-56MR-162
- [SDR SIMA2019112515005](https://openairdocs.org/sdr/SIMA2019112515005.md): Window · leaking · Nov 15, 2019 · N623AE · Emb EMB145LR · Flight Compartment Windows
  > DISCREPANCY: 21-30 AIR CONDITIONINGPRESSURATION CONTROL - WHILE PERFORMING CABIN PRESSURIZATION NOTICED AIR LEAK AT FWD BOTTOM CORNER OF FO'S DV WINDOW, CONFIRMED LEAKING OUT OF CRACK ON OUTSIDE OF FO'S DV WINDOW TO WINDSHIELD FRAME STRAP. MAJOR REPAIR-C/A-RE
- [SDR SIMA20191103003](https://openairdocs.org/sdr/SIMA20191103003.md): Light · inoperative · Nov 3, 2019 · N623AE · Emb EMB145LR · Emergency Lighting
  > RH OVER WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH OVER WING EMERGENCY LIGHT ASSY IAW E145 AMM 30-50-10. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.
- [SDR SIMA20190906002](https://openairdocs.org/sdr/SIMA20190906002.md): Light · inoperative · Sep 6, 2019 · N623AE · Emb EMB145LR · Emergency Lighting
  > LT WING EMERGENCY EXIT LIGHT MOUNTED IN PSU COVER IS INOP. C/A-REMOVED AND INSTALL LAMP AT SEAT ROW 12A LT WING EMERG EXIT. REF AMM 33-50-08. OPS CHK GOOD PER AMM TASK 33-50-00-700-801-A/500
- [SDR SIMA20190906004](https://openairdocs.org/sdr/SIMA20190906004.md): Light · inoperative · Sep 6, 2019 · N623AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT MOUNTED IN SERICE DOOR HINGE COVER IS INOP. C/A-REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT ASSY IAW AMM 33-50-10. OPS CK GOOD.
- [SDR SIMA20190906003](https://openairdocs.org/sdr/SIMA20190906003.md): Light · inoperative · Sep 6, 2019 · N623AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT MOUNTED IN MAIN PAX DOOR HINGE COVER IS INOP. C/A-REMOVED AND INSTALL LAMP IN MAIN PAX DOOR EMERG LIGHT. REF AMM 33-50-10. OPS CHK GOOD PER AMM TASK 33-50-00-700-801-A/500.
- [SDR SIMA201908097003](https://openairdocs.org/sdr/SIMA201908097003.md): Unknown · odor · Aug 7, 2019 · N623AE · Emb EMB145LR · Air Distribution System
  > AFTER LANDING STRONG SMELL OF OIL IN THE COCKPIT. SMELL DISSIPATED AFTER SWITCHING BLEEDS TO APU AND TURNING OFF RECIRCULATING FAN. TRANSFERRED TO NRWC #623-MIA-03121-C/A-COMPLIED WITH ETN-EM-72-034. NO SMELL OF OIL NOTED DURING TEST. C/W FIM TASK 21-20-00-81
- [SDR SIMA20190703002](https://openairdocs.org/sdr/SIMA20190703002.md): Warning System · false activation · Jul 3, 2019 · N623AE · Emb EMB145LR · Ground Proximity System
  > REF LGPG 4545587-2 TERRAIN AURAL WARNING MSG RANDOMLY CLIMBING OUT OF 6000FT UP TO ALTITUDE,DESENDING-TERRAIN MSG PERSISTED AND SINK RATE MSG ON APPROACH, ERRONEOUS MINIMUM CALL. AIRCRAFT REQ. INSPECTION FOR FERRY FLT. C/A-THIS AIRCRAFT HAS BEEN INSPECTED T
- [SDR SIMA2019060357004](https://openairdocs.org/sdr/SIMA2019060357004.md): Switch · failed · May 27, 2019 · N623AE · Emb EMB145LR · Cabin Cooling System
  > PACK #1 OVERLOAD-C/A-FLIGHT CREW PLACARDED PACK # 1 AUTH # 050917D-C MEL 21-28 MOC # 607040. T/S PER FIM 21-51-00-810-801. REMOVED AND DREPLACED PACK 1 OVER PRESSURE SWITCH AND OVERTEMP SWITCH IAW AMM 21-51-06 AND 21-51-08. OPC GOOD IAW 21-51-00. MEL RESTORED.
- [SDR SIMA20190321003](https://openairdocs.org/sdr/SIMA20190321003.md): Light · inoperative · Mar 21, 2019 · N623AE · Emb EMB145LR · Emergency Lighting
  > ROW 12 OVERHEAD EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED ROW 12 AISLE EMERGENCY LIGHT LAMP IAW AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD NO DEFECTS NOTED. END.
- [SDR SIMA20190124002](https://openairdocs.org/sdr/SIMA20190124002.md): Proximity Switch · failed · Jan 24, 2019 · N623AE · Emb EMB145LR · Landing Gear Position and Warning
  > SUPPLEMENTAL AFTER TAKEOFF LG/LEVER DISAGREE ON EICAS GEAR WOULD NOT RETRACT. C/A-ON INITIAL POWER UP, LG AIR/GND FAIL CAUTION MSG WAS DISPLAYED ON EICAS. CHECKED CMC MSGS IAW AMM 45-45-00. NO RELATED CMC MSGS NOTED. CHECKED LANDING GEAR PROXIMITY SWITCHES IAW
- [SDR SIMA20181212004](https://openairdocs.org/sdr/SIMA20181212004.md): Gcu · failed · Dec 12, 2018 · N623AE · Emb EMB145LR · AC Regulator
  > GEN1-4 OFF BUS EICAS MESSAGE DISPLAYED INTERMITTENTLY THEN RETURNED TO GEN 1 OFF BUS WHICH IS NORMAL CONDITION DUE TO CURRENT MEL. REMOVED AND REPLACED NR 4 GCU IAW AMM 24-31-02. OPS CHECK GOOD.
- [SDR SIMA2018101211003](https://openairdocs.org/sdr/SIMA2018101211003.md): Light · inoperative · Oct 11, 2018 · N623AE · Emb EMB145LR · Emergency Lighting
  > LT OVER WING EMERGENCY LIGHT INOP. -C/A-REMOVED AND REPLACED OVER WING EMERGENCY LIGHT BULB IAW AMM 33-50-10 OPS CHECK GOOD IAW AMM 33-50-00.
- [SDR SIMA20181003002](https://openairdocs.org/sdr/SIMA20181003002.md): Inverter · inoperative · Oct 3, 2018 · N623AE · Emb EMB145LR · Emergency Lighting
  > ON PS-1 CHECK FOUND CABIN GALLEY CEILING EMERGENCY EXIT LOCATOR SIGN INOP. FOUND NR 1 DC/AC INVERTER TO BE CAUSING LIGHT TO BE INOP. REMOVED AND REPLACED NR 1 DC/AC INVERTER IAW AMM 33-50-11-04. OPS CHECK GOOD.
- [SDR RAIA201803150001](https://openairdocs.org/sdr/RAIA201803150001.md): Bulb · inoperative · Mar 15, 2018 · N623AE · Emb EMB145LR · Emergency Lighting
  > RIGHT EMERGENCY DOOR FLOOD LIGHT IS INOPERATIVE. R & R THE FLOOD LIGHT BULB, OPS CHECKED GOOD.
- [SDR RAIA201801180001](https://openairdocs.org/sdr/RAIA201801180001.md): Floor Support · corroded · Jan 18, 2018 · N623AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > LEFT OMEGA BEAM IS CORRODED UNDER CROSSBEAM, BETWEEN FRAMES 43 - 44. REPAIRED.

Next page: https://openairdocs.org/aircraft/N623AE/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N623AE' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N623AE/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.