# Service difficulty reports: N671AE

A list on [N671AE](https://openairdocs.org/aircraft/N671AE.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Page 1 of 3 · 130 reports

- [SDR SIMA20220404001](https://openairdocs.org/sdr/SIMA20220404001.md): Lamp · inoperative · Apr 4, 2022 · N671AE · Emb EMB145LR · Emergency Lighting
  > GALLEY CEILING EMERGENCY LIGHT INOP-C/A-RAR GALLEY CEILING EMERGENCY LAMP IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECK GOOD. END.
- [SDR SIMA20220226002](https://openairdocs.org/sdr/SIMA20220226002.md): Not Reported · not reported · Feb 26, 2022 · N671AE · Emb EMB145LR · Emergency Lighting
  > SERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.
- [SDR SIMA20211222003](https://openairdocs.org/sdr/SIMA20211222003.md): None · none · Dec 22, 2021 · N671AE · Emb EMB145LR · Passenger Compartment Lighting
  > PASSENGER SEAT 15A AND 16A EMERGENCY LIGHT FLOOR POWER STRIP WIRE BORKEN.-C/A-RAR EMERGENCY FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12 OPC GOOD
- [SDR SIMA202108154001](https://openairdocs.org/sdr/SIMA202108154001.md): Lamp · inoperative · Aug 14, 2021 · N671AE · Emb EMB145LR · Emergency Lighting
  > GALLEY EMERGENCY LIGHT INOP. R & R GALLEY EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPC GOOD. END.
- [SDR SIMA20210618002](https://openairdocs.org/sdr/SIMA20210618002.md): Inverter · inoperative · Jun 18, 2021 · N671AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY INTERIOR LIGHT ADJ TO RH EMERGENCY EXIT INOP-C/A-REF TURNOVER, COMPLETED RAR OF #5 EMERG LIGHTS INVERTER IAW AMM 33-50-11. OPC GOOD.
- [SDR SIMA20210225002](https://openairdocs.org/sdr/SIMA20210225002.md): Flashlight Assy · broken · Feb 24, 2021 · N671AE · Emb EMB145LR · Emergency Lighting
  > AFT CABIN EMERGENCY FLASHLIGHT HOLDER HAD BROKEN CLIP-C/A-R & R AFT CABIN EMERGENCY FLASHLIGHT HOLDER ASSEMBLY IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPS CHECK GOOD.
- [SDR SIMA20210113001](https://openairdocs.org/sdr/SIMA20210113001.md): Light · inoperative · Jan 13, 2021 · N671AE · Emb EMB145LR · Emergency Lighting
  > AFT RT OVERWING EMERGENCY LIGHT INOPERABLE. C/A: R & R AFT RT OVERWING EMERGENCY LIGHT ASSEMBLY OPERATIONS CHECK GOOD, IAW AMM 33-50-10.
- [SDR SIMA20201217001](https://openairdocs.org/sdr/SIMA20201217001.md): Bulb · inoperative · Dec 17, 2020 · N671AE · Emb EMB145LR · Emergency Lighting
  > RT UPPER EMERGENCY EXIT LIGHT INOPERABLE. C/A: R & R RT UPPER EMERGENCY LIGHT BULB, IAW EMB 145 AMM 33-50-10. OPERATIONS CHECK GOOD. NO DEFECTS NOTED.
- [SDR SIMA20201128004](https://openairdocs.org/sdr/SIMA20201128004.md): Lamp · inoperative · Nov 28, 2020 · N671AE · Emb EMB145LR · Emergency Lighting
  > RT OVERWING EMERGENCY LIGHT INOPERABLE. C/A: R & R RT OVERWING EMERGENCY LIGHT LAMP, IAW EMB AMM TASK 33-50-07-000-801-A AND 33-50-07-400-801-A. OPERATIONS CHECK GOOD.
- [SDR SIMA202007232002](https://openairdocs.org/sdr/SIMA202007232002.md): Light · inoperative · Jul 22, 2020 · N671AE · Emb EMB145LR · Emergency Lighting
  > FOUND RT WING EMERGENCY LIGHT INOPERATIVE DURING PS-1 CHECK. REMOVED AND INSTALLED A NEW RT WING EMERGENCY LIGHT IAW AMM 33-50-10. OPS CHECKED GOOD. NO DEFECTS NOTED.
- [SDR SIMA2020031614003](https://openairdocs.org/sdr/SIMA2020031614003.md): Light · inoperative · Mar 14, 2020 · N671AE · Emb EMB145LR · Emergency Lighting
  > RH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECKED GOOD. END.
- [SDR SIMA202003110001](https://openairdocs.org/sdr/SIMA202003110001.md): Light · inoperative · Mar 10, 2020 · N671AE · Emb EMB145LR · Emergency Lighting
  > R/H WING EMERGENCY LIGHT INOP-C/A-RAR R/H WING EMERGENCY LIGHT IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.
- [SDR SIMA202003032005](https://openairdocs.org/sdr/SIMA202003032005.md): Transducer · failed · Mar 2, 2020 · N671AE · Emb EMB145LR · Air Intake Anti/De-Ice System
  > H.S. REJECTED T/O (80 KTS) DUE E2 A/I FAIL ON T.O. ROLL-C/A-RRMOVED AND REPLACED ENGINE #2 ANTI-ICING PRESSURE TRANDUCER IAW EMB145 AMM 30-21-06 LEAK/ OPS CHECK GOOD
- [SDR SIMA202002132004](https://openairdocs.org/sdr/SIMA202002132004.md): Anti-Ice Valve · failed · Feb 12, 2020 · N671AE · Emb EMB145LR · Engine Anti-Icing System
  > E1 A/ICE FAIL MESSAGE DURING CLIMB. RAN CHECHLIST, BUT MESSAGE REMAINED AND VALVE WOULD NOT OPEN WITH OVERRIDE NOB IN ALL. ALSO GOT AN ENG A/I OVERPRESS ADVISORY MESSAGE.-C/A-DEFFERED PER MEL 30-11 "M" PROCEDURES COMPLIED WITH. REMOVED AND REPLACED E1 ENG PRE
- [SDR SIMA201912275002](https://openairdocs.org/sdr/SIMA201912275002.md): Battery Pack · inoperative · Dec 25, 2019 · N671AE · Emb EMB145LR · Emergency Lighting
  > DURING PS-1 CHECK, FOUND EMERGENCY LIGHT INOPERATIVE BETWEEN 12A AND 9A. REMOVED AND REPLACED THE NR 3 BATTERY POWER SUPPLY AND BATTERY IAW AMM 33-50-04, OPS-CHECKED GOOD. NO FURTHER DEFECTS NOTED.
- [SDR SIMA201912274001](https://openairdocs.org/sdr/SIMA201912274001.md): Battery Pack · discharged · Dec 24, 2019 · N671AE · Emb EMB145LR · Emergency Lighting
  > FOUND EMERGENCY LIGHT BATTERY PACKS NR 2 AND 3 LOW, LIGHTS SHUT OFF AFTER APPOX 10 SECONDS. REMOVED AND REPLACED THE NR 2 BATTERY. OPS CHECKED GOOD IAW AMM 33-50-04. REMOVED AND REPLACED NR 3 BATTERY, OPS CHECKED GOOD IAW AMM 33-50-04.
- [SDR SIMA201912274003](https://openairdocs.org/sdr/SIMA201912274003.md): Bulb · inoperative · Dec 24, 2019 · N671AE · Emb EMB145LR · Emergency Lighting
  > LEFT FORWARD LOWER FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB IAW AMM 33-50-10.
- [SDR SIMA201912274002](https://openairdocs.org/sdr/SIMA201912274002.md): Light · inoperative · Dec 24, 2019 · N671AE · Emb EMB145LR · Emergency Lighting
  > FLOOR PROXIMITY STRIP NR 1 AFT SECTION INOPERATIVE. REMOVED AND REPLACED FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD, NO FURTHER DEFECTS NOTED.
- [SDR SIMA201912032003](https://openairdocs.org/sdr/SIMA201912032003.md): Battery Pack · inoperative · Dec 2, 2019 · N671AE · Emb EMB145LR · Emergency Lighting
  > DURING PS-1 CHECK FOUND MULTIPLE EMERGENCY LIGHTS OUT NEAR CENTER FUSELAGE.-C/A-REMOVED AND REPLACED #3 EMERGENCY LIGHT BATTERY AND CHARGER ASSEMBLY IAW EMB 145 W/C 33-700-19. OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 12788
- [SDR SIMA201911143010](https://openairdocs.org/sdr/SIMA201911143010.md): Unknown · smoke · Nov 13, 2019 · N671AE · Emb EMB145LR · Air Distribution System
  > ON TAXI OUT AFTER SWITCHING PACK 1 BACK ON, COCKPIT FILLED WITH SMOKE. AFTER SWITCHING PACK 1 BACK OFF SMOKE DISSIPATED-C/A-PERFORMED FIM TASK PROCEDURES EMB 145 FIM 21-20-00. RAN PACK 1 AND PACK 2 AND PERFORMED ALL VISUAL INSPECTIONS. NO DISCREPANCIES NOTED.
- [SDR SIMA201911087004](https://openairdocs.org/sdr/SIMA201911087004.md): Light · inoperative · Nov 7, 2019 · N671AE · Emb EMB145LR · Emergency Lighting
  > SERVICE DOOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT IAW AMM TASK 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.
- [SDR SIMA201910086010](https://openairdocs.org/sdr/SIMA201910086010.md): Wire · broken · Oct 6, 2019 · N671AE · Emb EMB145LR · Light System Wiring
  > 3EA WIRES BROKEN ON EMERGENCY LIGHT STRIP FLOOR CONNECTIONS-C/A-REPAIRED 3EA WIRES AT FLOOR PAELS 261BF AND 251FF IAW SWPM 20-21-00. OPS CHK GOOD
- [SDR SIMA201910086009](https://openairdocs.org/sdr/SIMA201910086009.md): Wire · broken · Oct 6, 2019 · N671AE · Emb EMB145LR · Light System Wiring
  > 1EA BROKEN WIRE ON EMERGENCY LIGHT STRIP AT FLOOR PANEL 251BF-C/A-REPAIRED 1EA WIRES AT FLOOR PANEL 251BF IAW SWPM 20-21-00. OPS CHK GOOD
- [SDR SIMA201910083010](https://openairdocs.org/sdr/SIMA201910083010.md): Shunt · gouged · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Main, Attach Fittings
  > FRAME 80 AFT SIDE AT APU SHUNT CONNECTION IS GOUGED (FRAME REINFORCEMENT)-C/A-REMOVED AND REPLACED REINFORCEMENT IAW SRM 53-32-04, GPM17-13 AND SRM 51-40-02.
- [SDR SIMA201910083009](https://openairdocs.org/sdr/SIMA201910083009.md): Shear Tie · corroded · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Internal Mounting Structure
  > SSI 53-30-48 FR 65 SHEAR CLIP IS CORRODED AT CARGO DOOR SILL AND ABOVE GUIDE PLATE-C/A-REMOVED AND INSTELLED SERVICEABLE SECTION OF FRAME 65 SHEAR IAW EMB 145 SRM 53-31-04.
- [SDR SIMA201910083008](https://openairdocs.org/sdr/SIMA201910083008.md): Rib · cracked · Oct 3, 2019 · N671AE · Emb EMB145LR · Wing, Rib/Bulkhead
  > LH WING RIB 21 IS CRACKED INSIDE PANEL 551CB.-C/A-REPAIRED LH WING RIB 21 INSIDE PANEL 551CB IAW EMB 145 SRM 57-20-07, ITEM #4.
- [SDR SIMA201910083007](https://openairdocs.org/sdr/SIMA201910083007.md): Door Sill · corroded · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > CARGO DOOR LOWER SILL IS CORRODED-C/A-REMOVED AND REPLACED CARGO DOOR LOWER SILL IAW EMB-145 SRM 51-40-02.
- [SDR SIMA201910083006](https://openairdocs.org/sdr/SIMA201910083006.md): Stringer · cracked · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Main, Longeron/Stringer
  > STGR 6R CRACKED AT FR 13-C/A-REMOVED AND INSTALLED NEW STRINGER 6R AT FRAME 13 IAW EMB 145 SRM 51-40-02.
- [SDR SIMA201910083005](https://openairdocs.org/sdr/SIMA201910083005.md): Floor Support · cracked · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > LH OMEGA BEAM OUTBD SUPPORT IS CRACKED AT PREVIOUS REPAIR AT FR 47-C/A-REMOVED AND REPLACED L/H OMEGA OUTBD SUPPORT AT FR 47 IAW EMB 145 SRM 53-23-02 AND SRM 51-40-02
- [SDR SIMA201910083004](https://openairdocs.org/sdr/SIMA201910083004.md): Stop Fitting · damaged · Oct 3, 2019 · N671AE · Emb EMB145LR · Cargo/Baggage Doors
  > CARGO DOOR FWD CONTINUOS STOP IS BENT AND CRACKED AT LOWER END-C/A-REMOVED AND INSTALLED NEW CARGO DOOR FWD CONTINUOS STOP IAW EMB 145 SRM 51-40-02
- [SDR SIMA201910083003](https://openairdocs.org/sdr/SIMA201910083003.md): Rib · cracked · Oct 3, 2019 · N671AE · Emb EMB145LR · Wing, Rib/Bulkhead
  > RH WING RIB 21 IS CRACKED INSIDE PANEL 651CB. REPAIRED RH WING RIB 21 INSIDE PANEL 651CB IAW EMB 145 SRM 57-20-07, ITEM #4
- [SDR SIMA201910083011](https://openairdocs.org/sdr/SIMA201910083011.md): Floor Support · corroded · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Miscellaneous Structure
  > SSI 53-20-11 LH OMEGA BEAM SIDEWALL CORRODED AT FR 29. REPAIRED LH OMEGA BEAM SIDEWALL AT FR 29 IAW ENVOY ERS-EM-53MR-3903
- [SDR SIMA201910083012](https://openairdocs.org/sdr/SIMA201910083012.md): Frame · gouged · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Main, Frame
  > FR 68 Z FRAME IS GOUGED AROUND 4 SCREW HOLES RH SIDE LOWER END-C/A-REMOVED AND REPLACED GOUGED FR 68 Z FRAME IAW EMB 145 SRM 51-40-02.
- [SDR SIMA201910083002](https://openairdocs.org/sdr/SIMA201910083002.md): Rib · cracked · Oct 3, 2019 · N671AE · Emb EMB145LR · Elevator, Spar/Rib
  > LEFT ELEVATOR INBOARD HINGE CUTOUT INBOARD NOSE RIB IS CRACKED -C/A-REMOVED AND INSTALLED NEW INBD NOSE RIB ON THE LEFT ELEVATOR INBOARD HINGE CUTOUT IAW EMB 145 SRM 51-40-02 AND 51-20-03.
- [SDR SIMA201910083001](https://openairdocs.org/sdr/SIMA201910083001.md): Door Frame · corroded · Oct 3, 2019 · N671AE · Emb EMB145LR · Fuselage Main, Structure
  > CARGO DOOR LOWER FRAME IS CORRODED AROUND 2 SCREW HOLES AT FWD END.-C/A-REMOVED AND INSTALLED NEW CARGO DOOR LOWER FRAME IAW EMB 145 SRM 51-20-03, 51-40-06 AND 51-40-02.
- [SDR SIMA20190721001](https://openairdocs.org/sdr/SIMA20190721001.md): Ecu · failed · Jul 21, 2019 · N671AE · Emb EMB145LR · Trailing Edge Flap Control System
  > AFTER TAKE OFF UPON RETRACTING THE FLAPS, WE GOT FLAPS FAIL MESSAGE ON THE EICAS. FLAPS DID NOT RETRACT AND STAYED AT 9*. WE COMPLIED WITH CHECKLIST AND LANDED IN MIA. C/A-REMOVE AND REPLACE FECU IAW AMM 27-53-02. OPS CHECK GOOD.
- [SDR SIMA201809187005](https://openairdocs.org/sdr/SIMA201809187005.md): Inverter · inoperative · Sep 17, 2018 · N671AE · Emb EMB145LR · Emergency Lighting
  > EMEREGENCY EXIT LIGHTED SIGN ON BACKSIDE OF AFT CALLEY (FACING THE SEATS) INOP. REMOVED AND REPLACED NR 2 DC/AC INVERTER IAW AMM 33-50-11 AND EMERGENCY LIGHTS OPS CHECK GOO IAW AMM 33-50-00-700-801.
- [SDR SIMA201808275002](https://openairdocs.org/sdr/SIMA201808275002.md): Generator · malfunctioned · Aug 25, 2018 · N671AE · Emb EMB145LR · DC Generating System
  > NR 3 GENERATOR OFF BUSS DURING TAKEOFF ROLL. REMOVED AND REPLACED THE NR 3 GENERATOR IAW WC 24-800-00, OP CHECKED GOOD AND LEAK CHECKED GOOD.
- [SDR SIMA2018082019001](https://openairdocs.org/sdr/SIMA2018082019001.md): Control Unit · failed · Aug 19, 2018 · N671AE · Emb EMB145LR · Trailing Edge Flap Control System
  > FLAP FAIL AFTER TAKE OFF STUCK AT 9. CMC HAD MULTIPLE OCURRENCES OF DRIVE SENSOR FAIL. HAD ONE OCURRENCE OF FLAP RT TRANSMISSION FAIL. TROUBLESHOT IAW FIM 27-51-00-810-817-A, AND FIM 27-51-00-810-801-A. REMOVED AND REPLACED THE FECU IAW AMM 27-53-02. OPS CH
- [SDR SIMA201808032001](https://openairdocs.org/sdr/SIMA201808032001.md): Lamp · inoperative · Aug 2, 2018 · N671AE · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT AT THE SERVICE DOOR WAS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPS CHECKED GOOD.
- [SDR SIMA20180224002](https://openairdocs.org/sdr/SIMA20180224002.md): Charger · failed · Feb 24, 2018 · N671AE · Emb EMB145LR · Emergency Lighting
  > BOTH AFT OVERWING EMERGENCY LIGHTS FAILED TO ILLUMINATE. COMPLIED WITH FIM 33-50-00. REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT BATTERY AND CHARGER IAW 33-50-04. OPS CHECKED GOOD IAW AMM 33-50-04.
- [SDR SIMA20180217012](https://openairdocs.org/sdr/SIMA20180217012.md): Charger · inoperative · Feb 17, 2018 · N671AE · Emb EMB145LR · Emergency Lighting
  > BOTH AFT OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE BATTERY AND CHARGER IAW W/C 33-700-19. OPS CHECKED GOOD.
- [SDR SIMA20180215005](https://openairdocs.org/sdr/SIMA20180215005.md): Battery Pack · inoperative · Feb 15, 2018 · N671AE · Emb EMB145LR · Emergency Lighting
  > SEVERAL EMERGENCY LIGHTS FOUND INOPERATIVE, LT AND RT EXTERNAL OVERWING. REMOVED AND REPLACED THE NR 4 BATTERY, PERFOMED AN OPS CHECK IAW 33-700-17. OPS CHECKED GOOD.
- [SDR SIMA20180215004](https://openairdocs.org/sdr/SIMA20180215004.md): Contactor · dirty · Feb 15, 2018 · N671AE · Emb EMB145LR · Light System Wiring
  > AFT GALLEY EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND CLEANED THE CONTACTORS IAW GENERAL MAINTENANCE, OPS CHECKED GOOD.
- [SDR SIMA20180202003](https://openairdocs.org/sdr/SIMA20180202003.md): Power Supply · failed · Feb 2, 2018 · N671AE · Emb EMB145LR · Emergency Lighting
  > LEFT AND RIGHT OVERWING EXTERNAL EMERGENCY LIGHTS FAILED TO ILLUMINATE. TROUBLESHOT IAW WM 33-50-50, AND R 7 R THE NR 4 EPSU IAW AMM 30-50-04. OPS CHECKED GOOD. BATTERY CHARGER ASSY.
- [SDR SIMA20180202002](https://openairdocs.org/sdr/SIMA20180202002.md): Wire Harness · failed · Feb 2, 2018 · N671AE · Emb EMB145LR · Landing Gear System Wiring
  > RECEIVED A LANDING GEAR AIR/GND FAIL CAUTION MESSAGE DURING CLIMBOUT. COULD NOT BRING GEAR UP. MESSAGE EXTINGUISHED 2 MINUTES LATER. BROUGHT GEAR UP. LANDED BACK AT DEPARTURE, GEAR DOWN. REMOVED AND REPLACED NLG AIR /GROUND WOW PROXIMITY SENSOR NR 2 IAW AMM 32
- [SDR SIMA20180107003](https://openairdocs.org/sdr/SIMA20180107003.md): Charger · failed · Jan 7, 2018 · N671AE · Emb EMB145LR · Emergency Lighting
  > BOTH AFT OVERWING EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT CHARGER AND BATTERY ASSY, OPS CHECKED BAD IAW AMM 33-50-04.
- [SDR SIMA20171214002](https://openairdocs.org/sdr/SIMA20171214002.md): Fuse · failed · Dec 14, 2017 · N671AE · Emb EMB145LR · Emergency Lighting
  > LH AND RH AFT OVERWING EMERGENCY LIGHTS INOP.-C/A-T/S PER FIM 33-50-00-810-804A. FOUND #4 EMERGENCY BATTERY POWER SUPPLY FUSE F1 INOP. REMOVED AND REPLACED #4 EMERGENCY BATTERY POWER SUPPLY FUSE F1 IAW CMM 25-60-03. OPS CHECK GOOD AT THIS TIME.
- [SDR SIMA20171108006](https://openairdocs.org/sdr/SIMA20171108006.md): Power Supply · inoperative · Nov 8, 2017 · N671AE · Emb EMB145LR · Emergency Lighting
  > BOTH OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-50-04. OPS GOOD.
- [SDR SIMA20171101001](https://openairdocs.org/sdr/SIMA20171101001.md): Battery · discharged · Nov 1, 2017 · N671AE · Emb EMB145LR · Emergency Lighting
  > LT AND RT OVERWING EMERGENCY LIGHT INOP. REPLACED NR 4 EMERGENCY BATTERY AND BATTERY POWER SUPPLY IAW AMM 33-50-04 OPS GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 19591.

Next page: https://openairdocs.org/aircraft/N671AE/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N671AE' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N671AE/reports

---