# Service difficulty reports: N763CC

A list on [N763CC](https://openairdocs.org/aircraft/N763CC.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR SIMA20260711002](https://openairdocs.org/sdr/SIMA20260711002.md): Flashlight Assy · damaged · Jul 11, 2026 · N763CC · Emb ERJ170100STD · Emergency Equipment
  > AFT FA EMERGENCY FLASHLIGHT DAMAGED RAR AFT FA FLASHLIGHT ASSY IAW ERJ 170 AMM 33-51-01/400 OPC GOOD
- [SDR SIMA20250628001](https://openairdocs.org/sdr/SIMA20250628001.md): Slide · detached · Jun 28, 2025 · N763CC · Emb ERJ170100STD · Escape Slide
  > L1 SLIDE FELL OFF DOOR AND IS SITTING IN FRONT GALLEY "TRANSFERRED TO NRWC 763-ORD-02614 ITEM-1" REPLACED EMERGENCY EVACUATION SLIDE IAW 25-65-01. NO DEFECTS NOTED
- [SDR SIMA20250306002](https://openairdocs.org/sdr/SIMA20250306002.md): Door · no discrepancy · Mar 6, 2025 · N763CC · Emb ERJ170100STD · Passenger/Crew Doors
  > DOOR L1 WAS VERY DIFFICULT TO DISARM AND OPEN. REQUEST INSPECTION. OPEN AND SHUT MAIN PAX DOOR AND ARMED AND DISARMED THE MAIN PAX DOOR SEVERAL TIMES WITH NO DEFECTS NOTED. THE ARMED AND DISARMED SHOWED IN THE DOOR WINDOW RESPECTIVE WITH THE HAND POSITION. ALL
- [SDR SIMA20250306003](https://openairdocs.org/sdr/SIMA20250306003.md): Rod · lack of lube · Mar 6, 2025 · N763CC · Emb ERJ170100STD · Passenger/Crew Doors
  > DOOR L1 VERY DIFFICULT TO DISARM/OPEN, REQUEST FIX LUBRICATED L1 DOOR ARMING FLAG ROD MECHANISM IAW ERJ 170 AMM 52-11-00, OPC OF DOOR OPENING AND CLOSING GOOD IAW ERJ 170 AMM 52-11-00.
- [SDR SIMA20250118001](https://openairdocs.org/sdr/SIMA20250118001.md): Shear Tie · corroded · Jan 18, 2025 · N763CC · Emb ERJ170100STD · Fuselage Internal Mounting Structure
  > SSI 53-23-003 SHEAR CLIP AT FR 88 STR 27R-28R IS CORRODED. (LEVEL 2 CORROSION) RAR SHEAR CLIP AT FR88 BETWEEN STR 27R-28R IAW EMB 170 SRM 51-40-08.
- [SDR SIMA20250115003](https://openairdocs.org/sdr/SIMA20250115003.md): Splice · corroded · Jan 15, 2025 · N763CC · Emb ERJ170100STD · Fuselage Miscellaneous Structure
  > SSI 53-23-005 AFT GALLEY CENTER SLICE AT FR 90 IS CORRODED. (LEVEL 2 CORROSION) RAR AFT GALLEY CENTER SPLICE AT FR90 IAW EMB 170 SRM 51-40-08.
- [SDR SIMA20250115004](https://openairdocs.org/sdr/SIMA20250115004.md): Floorbeam · corroded · Jan 15, 2025 · N763CC · Emb ERJ170100STD · Fuselage Main, Floor Beam
  > SSI 53-23-005 RH FLOOR BEAM CORRODED AT FR 85-86. (MAJOR REPAIR) (LEVEL 2 CORROSION) PERFORMED A PERMANENT REPAIR ON THE RH FLOOR BEAM BETWEEN FR 85-86 IAW ENVOY ERS-EJ-53MR-5127.
- [SDR SIMA20250115002](https://openairdocs.org/sdr/SIMA20250115002.md): Shear Panel · corroded · Jan 15, 2025 · N763CC · Emb ERJ170100STD · Fuselage Miscellaneous Structure
  > SSI 53-23-005 AFT GALLEY RH SHEAR PANEL IS CORRODED. (LEVEL 2 CORROSION) REMOVED AND REPLACED AFT GALLEY RH SHEAR PANEL IAW ERJ 170 SRM 51-40-08.
- [SDR SIMA20250115001](https://openairdocs.org/sdr/SIMA20250115001.md): Floorbeam · corroded · Jan 15, 2025 · N763CC · Emb ERJ170100STD · Fuselage Main, Floor Beam
  > SSI 53-23-005 RH FLOOR BEAM CORRODED AT FR 87. (LEVEL 2 CORROSION) PERFORMED A PERMANENT REPAIR ON THE RH FLOOR BEAM AT FR87 IAW ERJ 170 SRM 53-23-10/RE01
- [SDR SIMA20250115006](https://openairdocs.org/sdr/SIMA20250115006.md): Gusset · corroded · Jan 15, 2025 · N763CC · Emb ERJ170100STD · Fuselage Main, Structure
  > SSI 53-23-005 AFT GALLEY RH SPLICE AT FR 90 IS CORRODED. (LEVEL 2 CORROSION) RAR AFT GALLEY RH SPLICE AT FR90 IAW EMB 170 SRM 51-40-08.
- [SDR SIMA20250115005](https://openairdocs.org/sdr/SIMA20250115005.md): Seat Track · corroded · Jan 15, 2025 · N763CC · Emb ERJ170100STD · Fuselage, Seat/Cargo Attach Fittings
  > SSI 53-23-005 RH FLOOR BEAM CORRODED BETWEEN FR 84-85 (MAJOR REPAIR) (LEVEL 2 CORROSION) ACCOMPLISHED A PERMANENT REPAIR ON THE RH FLOOR BEAM BETWEEN FR 84-85 IAW EMB 170 SRM 53-23-10/REPAIR04P
- [SDR SIMA20250114004](https://openairdocs.org/sdr/SIMA20250114004.md): Seal Rest · corroded · Jan 14, 2025 · N763CC · Emb ERJ170100STD · Fuselage Miscellaneous Structure
  > SSI 53-21-009 FWD CARGO DOOR CUTOUT LOWER CENTER SEAL REST HAS CORROSION AT NUT PLATES. (MAJOR REPAIR) (LEVEL 2 CORROSION) REMOVED AND REPLACED FWD CARGO DOOR CUTOUT LOWER CENTER SEAL REST IAW ERJ 170 SRM 51-40-08
- [SDR SIMA20250106002](https://openairdocs.org/sdr/SIMA20250106002.md): Light · worn · Jan 6, 2025 · N763CC · Emb ERJ170100STD · Emergency Lighting
  > RH #3 EMERGENCY PHOTOLUMINESCENT FLOOR STRIP WORN OUT. RAR RH #3 PHOTOLUMINESCENT FLOOR STRIP IAW EMB 170 AMM 33-50-21.
- [SDR SIMA20241113001](https://openairdocs.org/sdr/SIMA20241113001.md): Landing Gear · faulted · Nov 13, 2024 · N763CC · Emb ERJ170100STD · Landing Gear Retraction/Extension System
  > LG WOW SYS FAIL EICAS ALERT POPULATED THE EICAS IMMEDIATELY AFTER GEAR RETRACTION. THE NOSE GEAR RETRACTED AFTER THE MAINS HAD FINISHED RETRACTING. WHILE THE NOSE GEAR WAS RETRACTING, WE HEARD METAL GRINDING AND A VERY LOUD BANG WHEN THE NOSE GEAR FINALLY RETR
- [SDR SIMA20240712001](https://openairdocs.org/sdr/SIMA20240712001.md): Warning Message · false activation · Jul 12, 2024 · N763CC · Emb ERJ170100STD · Engine Bleed Air System
  > BLEED 2 FAIL THROUGH 13000 QRH PROCEDUE CLEARED MSG BLEED 2 FAIL AGAIN THROUGH 16000 RAN QRH STEP 5 AND RETURNED TO RAP. EMERGENCY DECLARED. AT THIS TIME PERFORMED FIM TASK 36-10-00 ALSO C/W CHN 1 AND 2 RESET NO DEFECT NOTED
- [SDR SIMA20240601001](https://openairdocs.org/sdr/SIMA20240601001.md): Sensor · failed · Jun 1, 2024 · N763CC · Emb ERJ170100STD · Trailing Flap Position Indicating System
  > FLAP FAIL EICAS MESSAGE ON DEPARTURE. RETURN TO CMH DECLARED EMERGENCY. AS PER PREVIOUSLY RESTORED MEL 27-16 KVA INFO.1, REMOVED AND REPLACED LH INBD T3 SKEW SENSOR IAW AMM 27-53-06. RIG AND OPS CHECK GOOD. NO OTHER DEFECTS OR FAULT MSGS FOUND.
- [SDR SIMA20220427002](https://openairdocs.org/sdr/SIMA20220427002.md): None · none · Apr 27, 2022 · N763CC · Emb ERJ170200LR · Fire Bottle, Fixed
  > AT FL 100 CAUTION LIGHTS CRG FWD AND CRG AFT FIRE SYS FAIL STAYED ON FOR 60 SEC AT 11000 FT SAME CAUTION LIGHTS AND STAYED ON FOR 60 SECONDS-C/A-PERFORMED GENERIC I/O 3 MODULE RESET IAW ERJ-170 AMM 45-45-00-970-805-A PER ERJ 170 FIM 26-23-00. COULD NOT DUPLICA
- [SDR SIMA20220108002](https://openairdocs.org/sdr/SIMA20220108002.md): None · none · Jan 8, 2022 · N763CC · Emb · Emergency Lighting
  > FWD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT IS INOP REF. LOGPAGE: 4827465 ITEM: 2 MEL 2552 AUTH# 010134D-C -C/A-RAR FA EMERGENCY FLASH LIGHT ASSEMBLY IAW ERJ170 AMM TASK 33-51-01. OPC GOOD. NO DEFECTS NOTED AT THIS TIME. MEL ITEM RESTORED

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N763CC' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N763CC/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.