- [SDR SCNA20260608243](https://openairdocs.org/sdr/SCNA20260608243.md): Holder · tight · Jun 8, 2026 · N839SY · Boeing 737800* · Emergency Equipment
  > FA REPORTS 1R GIRT BAR CLIPS TO TIGHT. ADJUSTED GIRT BAR CLIPS TO ALLOW FOR EASIER REMOVAL OF THE GIRT BAR REFERANCE AMM 25-66-01
- [SDR SCNA20260325140](https://openairdocs.org/sdr/SCNA20260325140.md): Lamp · inoperative · Mar 24, 2026 · N839SY · Boeing 737800* · Emergency Lighting
  > ENTRY DOOR EMERGENCY SLIDE LIGHT INOP. REMOVED AND REPLACED SLIDE LIIGHT LAMP IAW AMM 33-51-04-960-801 SLIDE LIGHT STILL INOPERATIVE. REMOVED & REPLACED BATTERY PACK M1675. OPS CHECKS GOOD. REF AMM TASK 33-51-06-960-805."
- [SDR SCNA20250917377S](https://openairdocs.org/sdr/SCNA20250917377S.md): Floor Panel · broken · Sep 12, 2025 · N839SY · Boeing 737800* · Fuselage Floor Panel
  > BROKEN FLOOR PANEL 221QF AT W1, PASSENGER CABIN. DURING EMERGENCY LIGHTING SWITCH OPERATIONAL TEST EMERGENCY LIGHT CEILING AFT AND EMERGENCY LIGHT L1 EXT. AND INT. DON`T TURN ON. FAULT ISOLATION PROCEDURE AT LIGHT CEILING AFT AND EMERGENCY LIGHT L1 EXT. WAS
- [SDR SCNA20250930390](https://openairdocs.org/sdr/SCNA20250930390.md): Floorbeam · cracked · Sep 12, 2025 · N839SY · Boeing 737800* · Fuselage Main, Floor Beam
  > CRACK ON FLOOR SUPPORTS (2 EAS) AT STA 540 LBL 2 AND LBL 28 OF PASSENGER COMPARTMENT FLOOR STRUCTURE. FLOOR SUPPORT AT STA 540 LBL 2 OF PASSENGER COMPARTMENT FLOOR STRUCTURE WAS REPLACED PER B737-800 SRM 51-40-02-0G-0 AND (ET)(HFEC) INSPECTION WAS ACCOMPLISHE
- [SDR SCNA20250917377](https://openairdocs.org/sdr/SCNA20250917377.md): Floor Panel · broken · Sep 12, 2025 · N839SY · Boeing 7378 · Fuselage Floor Panel
  > BROKEN FLOOR PANEL 221QF AT W1, PASSENGER CABIN.
- [SDR SCNA20250909369S](https://openairdocs.org/sdr/SCNA20250909369S.md): Retainer · loose · Sep 8, 2025 · N839SY · Boeing 737800* · Emergency Equipment
  > MISSING SOLID FASTENER ON RETEINER CLIP OF GIRT BAR ESCAPE SLIDE COVER OF DOOR R1. MISSING SOLID FASTENER ON RETEINER CLIP OF GIRT BAR ESCAPE SLIDE COVER OF DOOR R1.WAS INSTALLED PER SRM 51-40-02-0G.
- [SDR SCNA20250909368S](https://openairdocs.org/sdr/SCNA20250909368S.md): Light · no test · Sep 8, 2025 · N839SY · Boeing 737800* · Emergency Lighting
  > DURING EMERGENCY LIGHTING SWITCH OPERATIONAL TEST EMERGENCY LIGHT CEILING AFT AND EMERGENCY LIGHT L1 EXT. AND INT. DON`T TURN ON. FAULT ISOLATION PROCEDURE AT LIGHT CEILING AFT AND EMERGENCY LIGHT L1 EXT. WAS PERFORMED PER FIM TASK 33-50 TASK 801 AND OPERATI
- [SDR SCNA20250909369](https://openairdocs.org/sdr/SCNA20250909369.md): Fastener · missing · Sep 8, 2025 · N839SY · Boeing 737800* · Emergency Equipment
  > INITIAL INSPECTION: MISING SOLID FASTENER ON RETEINER CLIP OF GIRT BAR ESCAPE SLIDE COVER OF DOOR R1. OPEN
- [SDR SCNA20250909368](https://openairdocs.org/sdr/SCNA20250909368.md): Light · no test · Sep 8, 2025 · N839SY · Boeing 737800* · Emergency Lighting
  > DURING EMERGENCY LIGHTING SWITCH OPERATIONAL TEST EMERGENCY LIGHT CEILING AFT AND EMERGENCY LIGHT L1 EXT. AND INT. DON""T TURN ON. OPEN
- [SDR SCNA20250811312](https://openairdocs.org/sdr/SCNA20250811312.md): Slide · no discrepancy · Aug 8, 2025 · N839SY · Boeing 737800* · Escape Slide
  > L2 DOOR SLIDE NOT IN HOUSING PROPERLY CHAIN CONNECTING FABRIC IS OVERLY TIGHT. INSPECTED AND CHECKED L2 DOOR SLIDE TASK # 25-66-01-200-802 NO DEFECTS FOUND AC FOR SERVICE
- [SDR SCNA20250613210](https://openairdocs.org/sdr/SCNA20250613210.md): Unknown · odor · Jun 13, 2025 · N839SY · Boeing 7378 · Air Distribution System
  > DECENDING THROUGH 7500' UNTIL TOUCHDOWN A VERY PUNGENT ODOR COMING FROM PACKS ONLY ON DESCENT SMELLED SIMILAR TO OLD GYLCOL - RESOLUTION: PERFORMED FIM TASK 21-00 TASK 806 NO DEFECT NOTED RAN AC COOLING PACKS WITH NO ODOR SMELL PRESENT AT THIS TIME
- [SDR SCNA20250516176](https://openairdocs.org/sdr/SCNA20250516176.md): Filter · dirty · May 15, 2025 · N839SY · Boeing 7378 · Air Distribution System
  > CABIN ODORS SMELLS. - CLEANED FWD CARGO RECIRCULATION AIR FILTER AREA AND REMOVED AND REPLACED AIR FILTER RECIRCULATION IAW AMM 21-15-01-000-801, 21-25-01-400-801
- [SDR SCNA20250411110](https://openairdocs.org/sdr/SCNA20250411110.md): Bracket · loose · Apr 10, 2025 · N839SY · Boeing 7378 · Emergency Equipment
  > DEFECT 717121: 1 R DOOR BRACKET ARE TO LOOSE - GIRT BAR DOES NOT FIRMLY INTO PLACE. RESOLUTION: INSPECTED GIRT BAR RETAINERS REF AMM 25-66-01 NO DEFECTS NOTED OK FOR SERVICE
- [SDR SCNA20241112363](https://openairdocs.org/sdr/SCNA20241112363.md): Oven · smoke · Nov 12, 2024 · N839SY · Boeing 7378 · Buffet/Galleys
  > DEFECT 716986: OVEN # 204 SMOKES WHEN USE FA CLEANED WANTS IT CHECKED.
- [SDR SCNA20240415193](https://openairdocs.org/sdr/SCNA20240415193.md): Girt Bar · damaged · Apr 14, 2024 · N839SY · Boeing 7378 · Emergency Equipment
  > 1R DOOR GIRT BAR DOES NOT WORK TROUBLE ARMING AND DISARMING DOOR. FOUND GIRT BAR RETAINER RIVET SHEARED, REPAIRED WITH APPROPRIATE HARDWARE PER SRM 51-40-3. GIRT BAR RETAINER OPERATES CORRECTLY PER AMM 25-66-01 OK FOR SERVICE.
- [SDR SCNA20240409190](https://openairdocs.org/sdr/SCNA20240409190.md): Slide · unwanted deploy · Apr 8, 2024 · N839SY · Boeing 7378 · Escape Slide
  > R1 ESCAPE SLIDE DEPLOYED. REPALCEING SLIDE
- [SDR SCNA20240220048](https://openairdocs.org/sdr/SCNA20240220048.md): Slide · dislodged · Feb 19, 2024 · N839SY · Boeing 7378 · Escape Slide
  > DEFECT 773078: FWD PAX DOOR EMERGENCY ESCAPE SLIDE FELL OUT OF BUSTLE - RESOLUTION: (IN PROGRESS)
- [SDR SCNA20231205247](https://openairdocs.org/sdr/SCNA20231205247.md): Unknown · unknown · Oct 17, 2023 · N839SY · Boeing 7378 · Emergency Lighting
  > WHILE INSTALLING FORWARD LAVATORY, IDENTIFIED A MISSING EMERGENCY LIGHT CONNECTOR. TERMINATED NEW CONNECTOR AND PERFORMED GOOD TEST OF L1187 PER SWPM 20-30-12 AND AMM 33-51-00-710-801.
- [SDR SCNA20221003117](https://openairdocs.org/sdr/SCNA20221003117.md): Light · inoperative · Jun 23, 2022 · N839SY · Boeing 7378 · Emergency Lighting
  > DEFECT 681052: L2 DOOR EMERGENCY LIGHT INOP RESOLUTION: R&R LIGHT LAMP AND BONDING PER AMM 33-51-04-960-802.
- [SDR SCNA20220427034](https://openairdocs.org/sdr/SCNA20220427034.md): Hook · broken · Apr 7, 2022 · N839SY · Boeing 7378H4 · Passenger Compartment Equipment
  > RI DOOR SLIDE HOOKS ON DOOR THRESHOLD AND IS PULLING OUT OF BUSSEL. RESOLUTION: REPOSITIONED SLIDE IN BASKET REF M/M 25-66-00
- [SDR SCNA20220414025](https://openairdocs.org/sdr/SCNA20220414025.md): None · none · Mar 21, 2022 · N839SY · Boeing 737 · Emergency Lighting
  > DEEFECT: FRONT RIGHT AREA LIGHT BURN OUT ( CABIN INTERIOR ILLUMINATION; AIRCRAFT WITH PHOTOLUMINESCENT EMERGENCY ESCAPE PATH MARKING SYSTEMS). RESOLUTION: R&R LIGHT PER AMM 33-22-00 OP CHECKS GOOD THIS CLEARS MEL 33-2-2 OK FOR SERVICE
- [SDR SCNA20220325017](https://openairdocs.org/sdr/SCNA20220325017.md): None · none · Feb 24, 2022 · N839SY · Boeing 7378 · Emergency Lighting
  > DEFECT: SIDE WALL LIGHT ON R/H FIRST EMERGENCY EXIT DOOR INOP. RESOLUTION: PERFORMED EMERGENCY EXIT DOOR LIGHT OPERATIONAL TEST PER AMM 33-51-00-710-801 OPS CHECK GOOD.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N839SY' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N839SY/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.