- [SDR SCNA20260908381](https://openairdocs.org/sdr/SCNA20260908381.md): Light · unsecure · Sep 6, 2026 · N841SY · Boeing 737800* · Emergency Lighting
  > LEFT SIDE EXIT PATH LIGHT ROW 10-12 LIGHTING STRIP LIFTING DA34012. SECURED FLOOR STRIPPING LIGHTING IAW CMM 33-51-07. OPS CHECKED GOOD.
- [SDR SCNA20260728330](https://openairdocs.org/sdr/SCNA20260728330.md): Lamp · inoperative · Jul 27, 2026 · N841SY · Boeing 737800* · Emergency Lighting
  > AFT LT GALLEY DOOR EMERGENCY SLIDE LIGHT INOPERATIVE. RELAMPED L2 DOOR SLIDE LIGHT IAW AMM 33-51-04. OPS CHECK GOOD
- [SDR SCNA20260728329](https://openairdocs.org/sdr/SCNA20260728329.md): Lamp · inoperative · Jul 27, 2026 · N841SY · Boeing 737800* · Emergency Lighting
  > LEFT FWD OVERWING EMERGENCY EXIT WING EXIT LIGHT INOPERATIVE. RELAMPED LH FWD EMERGENCY OVERWING EXIT EXTERIOR LIGHT IAW AMM 33-51-04. OPS CHECK GOOD
- [SDR SCNA20260724325](https://openairdocs.org/sdr/SCNA20260724325.md): Window · detached · Jul 23, 2026 · N841SY · Boeing 737800* · Escape Slide
  > VIEWING WINDOW OFF SLIDE 1R FELL OFF. SECURED VIEWING WINDOW ON 1R DOOR SLIDE REF AMM 25-66-00. THIS CLEARS MEL 25-10N.
- [SDR SCNA20260518205S](https://openairdocs.org/sdr/SCNA20260518205S.md): Carpet · unsecure · May 17, 2026 · N841SY · Boeing 737800* · Passenger Compartment Equipment
  > ROW 1 RIGHT SIDE CARPET CORNER LIFTING CREATING TRIPPING HAZARD. REPLACED DOUBLESIDE CARPET TAPE IAW AMM 25-27-15 CARPET IS SECURE & TRIP HAZARD REMOVED. THIS CLEARS MEL 25-10N MDDR# 138892
- [SDR SCNA20260518205](https://openairdocs.org/sdr/SCNA20260518205.md): Carpet · unsecure · May 17, 2026 · N841SY · Boeing 737800* · Passenger Compartment Equipment
  > ROW 1 RIGHT SIDE CARPET CORNER LIFTING CREATING TRIPPING HAZARD ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF))
- [SDR SCNA20260406147](https://openairdocs.org/sdr/SCNA20260406147.md): Window · broken · Apr 4, 2026 · N841SY · Boeing 737800* · Escape Slide
  > ESCAPE SLODE PRESSURE GUAGE GLASS BROKEN, R1 DOOR. REATTACHED VIEWING WINDOW IAW AMM 25-00-00 OK FOR SERVICE
- [SDR SCNA20260323131](https://openairdocs.org/sdr/SCNA20260323131.md): Hydraulic System · overserviced · Mar 22, 2026 · N841SY · Boeing 737800* · Hydraulic System, Main
  > DURING DECENT INTO DFW WE SMELLED A DIRTY SOCK ODOR IN THE FLIGHT DECK THE LEAD FA REPORTED THIS AS WELL. PERFORMED FIM 21-00 ASK 806 AND FOUND HYD B QTY AT OVER 106%. LOWERED HYD TO 99%. RAN APU AND NO SMELL DETECTED. RAN #1 AND #2 ENG, NO SMELL DETECTED AFT
- [SDR SCNA20260107015](https://openairdocs.org/sdr/SCNA20260107015.md): Lamp · inoperative · Jan 6, 2026 · N841SY · Boeing 737800* · Emergency Lighting
  > ROW 6ABC AREA EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED ROW 6ABC AREA EMERGENCY LIGHT LAMP IAW AMM 33-51-03-960-801, OPS CHECKED GOOD.
- [SDR SCNA20260107014](https://openairdocs.org/sdr/SCNA20260107014.md): Fuse · failed · Jan 6, 2026 · N841SY · Boeing 737800* · Emergency Lighting
  > L2 EXTERIOR SLIDE EMERGENCY LIGHT INOPERATIVE. FOUND FUSE IN AFT LT POWER SUPPLY INOPERATIVE.
- [SDR SCNA20250918381S](https://openairdocs.org/sdr/SCNA20250918381S.md): Cover · missing · Sep 17, 2025 · N841SY · Boeing 737800* · Emergency Equipment
  > DOOR 1R SLIDE HOUSING PLASTIC GAGE COVER MISSING ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) REMOVED 1R DOOR SLIDE INSTALLED NEW SLIDE GAUGE WINDOW REINSTALLED 1R DOOR SLIDEREF AMM 25-66-01 RII COMPLETE THIS CLEARS MEL 25-10N.
- [SDR SCNA20250918381](https://openairdocs.org/sdr/SCNA20250918381.md): Cover · missing · Sep 17, 2025 · N841SY · Boeing 7378 · Emergency Equipment
  > R1 DOOR SLIDE HOUSING PLASTIC GAGE COVER MISSING. OPEN
- [SDR SCNA20250714259](https://openairdocs.org/sdr/SCNA20250714259.md): Light · unsecure · Jul 14, 2025 · N841SY · Boeing 7378 · Emergency Lighting
  > DEFECT 806830: EMERGANCY LIGHTING FLOORSTRIP AT ROW 12 DEF IS AROUND & STRINKING UP OFF FLOOR - RESOLUTION: RE-SECURED EMERGANCY LIGHT FLOORSTRIP AT ROW 12DEF IAW AMM 33-51-15. NO DEFECTS NOTED AT THIS TIME. OK TO CONTIINUE AT THIS TIME
- [SDR SCNA20250707247](https://openairdocs.org/sdr/SCNA20250707247.md): Web · corroded · Jun 26, 2025 · N841SY · Boeing 737800* · Fuselage Miscellaneous Structure
  > CORROSION ON TRUSS WEB ON STA 616 APROX AT LOWER SURFACE KEEL BEAM. TRUSS WEB ON STA 616 APROX AT LOWER SURFACE KEEL BEAM WAS REPAIRED PER ETI-737-25-079 REVISION 4 AND ENGINEERING TASK CARD ENG-53SCA-11692 AND MM4-SCA-25-0014
- [SDR SCNA20250707246](https://openairdocs.org/sdr/SCNA20250707246.md): Pressure Deck · cracked · Jun 23, 2025 · N841SY · Boeing 737800* · Fuselage Main, Structure
  > CRACK OF 0.625 IN LENGTH ON VERTICAL PRESSURE WEB AT LEFT SIDE OF VERTICAL PRESSURE DECK WEB STA 663 LBL 34 IN REFERENCE TASK CARD ENG-57SCA-11508 STEP 5. A). PRESSURE WEB AT LEFT SIDE OF VERTICAL PRESSURE DECK WEB STA 663 LBL 34 WAS REPAIRED PER B737-800 SRM
- [SDR SCNA20250609202](https://openairdocs.org/sdr/SCNA20250609202.md): Clamp · unsecure · Jun 8, 2025 · N841SY · Boeing 7378 · Navigation System
  > WORK ORDER 88477, NR00094: DURING GROSS INT. HYD. SYS. LEAKAGE CHECK, WHEN PLACING AMP.-CLAMP IN EMDP RELAY (P92), IT CREATED AN ELECTRIC ARC AND FLAMED THE COATING OF THE CABLES. CABLES IN P92 WERE REPAIRED PER B737-800 SWPM 20-10-13 AND EMDP TEST WAS PERF
- [SDR SCNA20250605197](https://openairdocs.org/sdr/SCNA20250605197.md): Pin · missing · Jun 4, 2025 · N841SY · Boeing 7378 · Escape Slide
  > MISSING CLIP PIN (3 EAS) ON R1, L1 & R2 ESCAPE SLIDE STOWAGE BOX. NEW CLIP PIN (3 EAS) ON R1, L1 & R2 ESCAPE SLIDE STOWAGE BOX WAS INSTALLED PER B737-800 AMM 25-66-01.
- [SDR SCNA20250605196](https://openairdocs.org/sdr/SCNA20250605196.md): Release Mech · broken · Jun 4, 2025 · N841SY · Boeing 7378 · Emergency Equipment
  > BROKEN STOP RELEASE OF GIRT BART OF ESCAPE SLIDE L2. STOP RELEASE OF GIRT BAR OF SCAPE SLIDE L2.WAS REPLACED PER B737-800 AMM 25-66-01.
- [SDR SCNA20250402091](https://openairdocs.org/sdr/SCNA20250402091.md): Bulb · inoperative · Apr 2, 2025 · N841SY · Boeing 7378 · Emergency Lighting
  > ROWS 22R AND 25R AISLE EMERGENCY LIGHTS NOT ILLUMINATING. - REMOVED AND REPLACED BULBS AT ROW 22R AND 25R. CLEANED AND RESECURED WIRING HARNES AT ROW 25R. REMOVED AND REPLACED AFT RIGHT CHARGER ASSEMBLY AND BATTERY PACK. REF AMM 33-51-00. OPS CHECKS OK.
- [SDR SCNA20250401088](https://openairdocs.org/sdr/SCNA20250401088.md): Light · inoperative · Mar 30, 2025 · N841SY · Boeing 7378 · Emergency Lighting
  > R2 DOOR INSIDE EMERGENCY EXIT LIGHT INOP. OPEN
- [SDR SCNA20250331088](https://openairdocs.org/sdr/SCNA20250331088.md): Battery Pack · inoperative · Mar 22, 2025 · N841SY · Boeing 7378 · Emergency Lighting
  > R&R RT AFT EMERGENCY POWER SUPPLY BATTERY PACK IAW AMM 33-51-06.OPS CK GOOD.
- [SDR SCNA20250217052](https://openairdocs.org/sdr/SCNA20250217052.md): Bracket · loose · Feb 17, 2025 · N841SY · Boeing 7378 · Emergency Equipment
  > DEFECT 797137: 1L GIRT BAR BRACKET LOOSE. - - RESOLUTION: INSPECTED L1 GIRT BAR BRACKETS. NO DEFECTS NOTED. REF AMM 25-66-02. A/C OK FOR SERVICE.
- [SDR SCNA20241114368](https://openairdocs.org/sdr/SCNA20241114368.md): Light · detached · Jul 14, 2024 · N841SY · Boeing 7378 · Emergency Lighting
  > DEFECT 776588: ESCAPE PATH LIGHTING LIFTING OFF FROM THE FLOOR AND BENT NEXT TO SEAT 12 D. RESOLUTION: INSPECTED AND REATTACHED PHOTOLUMINESCENT FLOOR STRIP LIGHTING REF AMM 33-51-15. OK FOR SERVICE.
- [SDR SCNA20240214032](https://openairdocs.org/sdr/SCNA20240214032.md): Light · cracked · Feb 10, 2024 · N841SY · Boeing 7378 · Emergency Lighting
  > DEFECT 731644: - EMERGENCY EXIT LIGHT STRIP CRACKED + DIRTY NEAR 2R LAV. - RESOLUTION: REMOVED AND REPLACED SAFTY GLOW STRIP LIGHT NEAR 2R LAV IAW AMM 33-51-15. OK FOR SERVICE.
- [SDR SCNA20240108005](https://openairdocs.org/sdr/SCNA20240108005.md): Unknown · unknown · Jan 8, 2024 · N841SY · Boeing 7378 · Hydraulic Pump (Electric/Engine), Main
  > DEFECT 731540 - - #2 ENG HYD PUMP LOW PRESS IN CRZ. B SYS QTY SHOWS 0 AND PRESSURE SHOWS >2900 PSI. #2 ENG HYD PUMP SWITCHED OFF PER QRH. - - RESOLUTION: (IN RPOGRESS)
- [SDR SCNA20231205255](https://openairdocs.org/sdr/SCNA20231205255.md): Unknown · unknown · Dec 4, 2023 · N841SY · Boeing 7378 · Emergency Lighting
  > DEFECT L2 DOOR EMER LIGHT INOP - - RESOLUTION: RELAMPED EMER LIGHT L2 DOOR SLIDE REF AMM 33-51-04
- [SDR SCNA20231011232](https://openairdocs.org/sdr/SCNA20231011232.md): Unknown · unknown · Oct 7, 2023 · N841SY · Boeing 7378 · Buffet/Galleys
  > AFT OVEN NEAR 2L DOOR F/A REPORTS WAS SMOKING AND SMELLED LIKE ELECTRICAL BURNING. STOPS AFTER OVEN SHUTOFF. OPS CHECKED #2 OVEN PER AMM 25-32-98. OPS CHECK GOOD. THIS CLEARS MEL.
- [SDR SCNA20230828210](https://openairdocs.org/sdr/SCNA20230828210.md): Unknown · unknown · Jul 18, 2023 · N841SY · Boeing 7378 · Emergency Lighting
  > DEFECT W/O 80357: 18ABC EMERGENCY AREA LIGHT ASSEMBLY LOOSE. REF AMM 33-51-03-960-802. REINSTALLED 18ABC EMERGENCY AREA LIGHT ASSEMBLY IAW AMM 33-51-03.
- [SDR SCNA20230718204](https://openairdocs.org/sdr/SCNA20230718204.md): Unknown · unknown · Jul 17, 2023 · N841SY · Boeing 7378 · Emergency Lighting
  > DEFECT 713405: EMER CHGR LT AFT CB BEHIND CAPT. P18-3 A10 KEEPS POPPING. - - - RESOLUTION: (IN PROGRESS)
- [SDR SCNA20230622191](https://openairdocs.org/sdr/SCNA20230622191.md): Unknown · unknown · Jun 20, 2023 · N841SY · Boeing 7378 · Emergency Equipment
  > OPENED DOOR SLIDE CASE AND REPLACED VIEWING WINDOW IAW AMM 20-30-11
- [SDR SCNA20230622190](https://openairdocs.org/sdr/SCNA20230622190.md): Unknown · unknown · Jun 20, 2023 · N841SY · Boeing 7378 · Escape Slide
  > REMOVED SLIDE AND PLACED ON TABLE ON FLOOR. OPENED SLIDE COVER PER AMM 25-64-00. REMOVED AND REPLACED DAMAGED WINDOW REF: CMM 25-60-37. NEED TO REASSEMBLE COVER AND INSTALL INTO R-2 DOOR. AFTER WINDOW SEALANT SETS UP.
- [SDR SCNA20230621191](https://openairdocs.org/sdr/SCNA20230621191.md): Unknown · unknown · Jun 20, 2023 · N841SY · Boeing 7378 · Emergency Equipment
  > DEFECT W/O 79405 NR0008: R1 DOOR SLIDE COVER PRESSURE VIEWING WINDOW CRACKED. - - - RESOLUTION: (IN PROGRESS)
- [SDR SCNA202306211901](https://openairdocs.org/sdr/SCNA202306211901.md): Unknown · unknown · Jun 20, 2023 · N841SY · Boeing 7378 · Emergency Equipment
  > DEFECT W/O 79401, NR0007: R2 DOOR SLIDE COVER PRESSURE VIEWING WINDOW CRACKED. - - - RESOLUTION: (IN PROGRESS)
- [SDR SCNA20230525162](https://openairdocs.org/sdr/SCNA20230525162.md): Unknown · unknown · May 24, 2023 · N841SY · Boeing 7378 · Emergency Equipment
  > DEFECT 759564: 2R DOOR GIRT BAR STOWAGE HOOK ( RIGHT) PREVENTS GIRT BAR FROM BEING REMOVED (DIFFICULT). - - -RESOLUTION: OPS CHECKED R2 GIRT BAR STOWAGE HOOKS REF AMM 25-66-00 OPS CHECK GOOD.
- [SDR SCNAS20220405023](https://openairdocs.org/sdr/SCNAS20220405023.md): None · none · Mar 25, 2022 · N841SY · Boeing 7378 · Powerplant System
  > DEFECT: GATE RETURN FOR EXCESSIVE SMOKE FROM ENG#1. RESOLUTION: PERFORMED 79-05-TASK 801 NO EXTERNAL LEAKS NOTED. PERFORMED ENGINE VENT AND DRAINS INSPECT NO LEAKS NOTED PERFORMED SCAVENGE FILTERS INSPECTION. FOUND TEFLON MATERIAL IN FWD SUMP REF 79-00

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N841SY' AND registry_match = 'registration'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/aircraft/N841SY/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.