# N173DN: 1990 Boeing 767-332, registration cancelled 2017-09-06

- Type: Cancelled registration (FAA registry, deregistered aircraft)
- Cancelled: September 6, 2017
- Status when cancelled: First renewal notice
- Airframe: [Boeing 767-332](https://openairdocs.org/model/boeing-767-332) (registry code 1385101)
- Engine: [Pratt & Whitney PW4000 series](https://openairdocs.org/engine/pratt-whitney-pw4000-series) (registry code 52119)
- Data sheets: [TCDS A1NM](https://openairdocs.org/tcds/A1NM) (OpenAirDocs)
- Serial number: 24800
- Year built: 1990
- Type of aircraft: Fixed wing multi engine
- Engine type: Turbo-fan
- Airworthiness: Standard, transport
- Airworthiness date: June 25, 1990
- Certificate issued: July 3, 1990
- Last registry action: August 20, 2014
- Mode S code: A124AA
- Owner when cancelled: [Delta Air Lines Inc](https://openairdocs.org/faa-owner/DELTA%20AIR%20LINES%20INC)
- Location: [Atlanta, GA](https://openairdocs.org/faa-place/GA/Atlanta)
- Owner type: Corporation
- Owner's area on the map: 33.6604° N, 84.3865° W: Placed by OpenAirDocs at the center of ZIP code 30354, within about 2 miles (OpenAirDocs). The owner's mailing address, not where the aircraft was based
- The mark today: https://openairdocs.org/aircraft/N173DN
- FAA registry: https://registry.faa.gov/AircraftInquiry/Search/NNumberResult?nNumberTxt=173DN
- Page: https://openairdocs.org/deregistered/N173DN-2017-09-06

From the FAA registry file of November 12, 2026, cancelled registrations. Owners' street addresses are left out. The Mode S code belongs to the N-number, not the airframe.

ADs and bulletins for the Boeing 767-332: https://openairdocs.org/model/boeing-767-332.md

## Service difficulty reports (49)

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.

- [SDR DL76L081773](https://openairdocs.org/sdr/DL76L081773), Dec 21, 2008: ACTUATOR. FROZEN. RIGHT PACK WAS PUTTING OUT EXCESSIVE TEMP AIR MAIN CABIN WAS 87. ONLY WAY TO CONTROL CABIN TEMP WAS TO SHUT OFF RIGHT PACK. TEMP RETURNED TO NORMAL WITH PACK OF
- [SDR DL76L081768](https://openairdocs.org/sdr/DL76L081768), Dec 18, 2008: ENGINE. MALFUNCTIONED. NR 2 ENG CHANGE DUE TO STAGGER. INSTALLED S/N 724715.
- [SDR DL76L081767](https://openairdocs.org/sdr/DL76L081767), Dec 18, 2008: ENGINE. MALFUNCTIONED. NR 1 ENG CHANGE FOR STAGGER, INSTALLED S/N 727678.
- [SDR DL76L081710](https://openairdocs.org/sdr/DL76L081710), Dec 10, 2008: COMPUTER. MALFUNCTIONED. AFTER PUSHBACK GOT STATUS MSG ELEV FEEL, IT CLEARED AFTER STARTING BOTH ENGINES READ NEEDED HYD PRESSURE IN MDM. AFTER A COUPLE OF MINUTES IT RETURNED AND WOULD
- [SDR DL76L080730](https://openairdocs.org/sdr/DL76L080730), May 13, 2008: WIRE. CHAFED. WHEN THROTTLES ADVANCED FOR TAKEOFF RT ENG OIL PSI LIGHT ILLUMINATED AND RT ENG OIL PSI EICAS MSG ANNUNCIATED, LIGHT EXT WITH THROTTLES AT IDLE, RE-ILLUMINATED 
- [SDR DL76L071168](https://openairdocs.org/sdr/DL76L071168), Sep 2, 2007: WIRE HARNESS. DAMAGED. DURING DRC CHECK, FOUND APU EGT HARNESS BURNED WIRE INSULATION DAMAGED EXHAUST LEAK. REMOVED AND REPLACED APU PER OPN 6051 AND OPN 7951.
- [SDR DL76L070384](https://openairdocs.org/sdr/DL76L070384), Apr 27, 2007: ANGLE. CRACKED. THE NR 2 PYLON CLOSEOUT ANGLE WAS FOUND WITH A CRACK IN THE OUTBOARD SIDE. THE MIDSPAR FITTINGS ALSO HAD TOOLING DAMAGE. THE DAMAGED ANGLE WAS REPAIRED WITH REP
- [SDR DALA1108510173](https://openairdocs.org/sdr/DALA1108510173), Apr 19, 2007: FITTING. DAMAGED. FLAP COLLAR FITTING REPLACED IAW EA 01-073591-12, ME12, ME13, ME20, ME21.
- [SDR DL76L070321](https://openairdocs.org/sdr/DL76L070321), Apr 14, 2007: RELAY. UNKNOWN. LT ENG EEC MODE STATUS. REPLACED K402 RELAY FOR THE LT ENG PROBE HEAT. RAN ENG, OP CKS GOOD.
- [SDR DL76L070047](https://openairdocs.org/sdr/DL76L070047), Jan 19, 2007: WIRE. CHAFED. DURING BRAKE RELEASE WHILE PUSHING THROTTLES FORWARD AT APPROX 1.3 EPR, THE RIGHT ENG OIL PRESSURE LIGHT ILLUMINATED AND PRESSURE GAUGE READ AT APPROX 213PSI. I
- [SDR DL76L060670](https://openairdocs.org/sdr/DL76L060670), Aug 21, 2006: DISPLAY. INOPERATIVE. F/O MCDU FROZE. UNABLE TO HAVE A SUCCESSFUL RESET. DIVERTED TO JFK WHERE PARTS ARE AVAIL. REMOVED AND REPLACED F/O MCDU, OPS NORMAL.
- [SDR DL76L060578](https://openairdocs.org/sdr/DL76L060578), Jul 11, 2006: FMU. MALFUNCTIONED. DURING ENG START ACHIEVED STARTER CUTOUT THEN N2 ROLLED BACK REPLACED FMU AND PUMP. C/W LEAK CK. BORO INSP NR 2 ENG, OPS CK ENG START AND OPS PER MM. OK FOR SER
- [SDR DL76L060370](https://openairdocs.org/sdr/DL76L060370), May 11, 2006: LAMP. INOPERATIVE. FOUND LT SIDE EMERGENCY OVERWING LIGHT INOP. RELAMPED CKS OK.
- [SDR DL76L060273](https://openairdocs.org/sdr/DL76L060273), Apr 15, 2006: ENGINE. SHUTDOWN. AT GATE WITH LT ENG RUNNING LT BLEED ON AND 1 PACK RUNNING ENG BEGAN TO VIB THEN SHUTDOWN. BOOST PUMPS WERE TURNED OFF JUST PRIOR TO SHUTDOWN. PERFORMED BITE OF
- [SDR DL76L050747](https://openairdocs.org/sdr/DL76L050747), Nov 27, 2005: ANGLE. CRACKED. NR 1 ENGINE PYLON MID SPAR CLOSE OUT ANGLE WAS FOUND CRACKED. REPLACED CRACKED MID SPAR CLOSE OUT ANGLE AND INSPECTED MID SPAR FITTINGS, REF AD 2005-19-23.
- [SDR DL76L050454](https://openairdocs.org/sdr/DL76L050454), Aug 15, 2005: BATTERY. INOPERATIVE. IR - ON L/O, FOUND EMERGENCY EXIT SIGNS AT DOOR 1L AND 1R. REMOVED AND REPLACED BATTERY PACK FOR DOOR 1L AND 1R EXIT SIGNS, NOW OPS NORMAL.
- [SDR DL76L050448](https://openairdocs.org/sdr/DL76L050448), Aug 11, 2005: OVEN. SMOKE. BOTH AFT GALLEY OVENS PRODUCED SMOKE. C/BS PULLED. CKD OVENS FOUND BUN BEHIND THE TRAY. OPERATED FOR 30 MINS. OPS NORM, OVEN CLEANED.
- [SDR DL76L050127](https://openairdocs.org/sdr/DL76L050127), Feb 23, 2005: ENGINE. SURGES. DURING T/O FROM ATL, NR 2 ENGINE SURGED APPROX 5 TIMES. AIRCRAFT RETURNED TO ATL. REPLACED ENGINE.
- [SDR DL76L050063](https://openairdocs.org/sdr/DL76L050063), Jan 27, 2005: LOGIC CARD. FAILED. FWD CARGO FIRE WARNING LIGHT AND FIRE BELL ACTIVATED IN FLT. REPLACED M10427 CARD.
- [SDR DL76L040151](https://openairdocs.org/sdr/DL76L040151), Jan 18, 2004: LATCH. CORRODED. DURING OFFWING SLIDE COMPARTMENT DOOR LATCH INSPECTION OPN 5894AD, MISC HARDWARE FOUND TO BE CORRODED. REPLACED DELTA PART NUMBERS: 251211768, 011216100, 251210
- [SDR DL76L030108](https://openairdocs.org/sdr/DL76L030108), Jan 29, 2003: ENGINE. DAMAGED. NBR 1 ENGINE STRUCK BY DEICING BUCKET CREATING 1 FT HOLE IN NOSE COWL. REPLACED NBR 1 ENG INLET COWL PER M/M 71-11-01-4 ETOPS CATEGORY 'F': ANY OTHER EVENT DETR
- [SDR DL76L021321](https://openairdocs.org/sdr/DL76L021321), Nov 15, 2002: PROBE. FAILED. DIVERTED TO AMS FOR TAT PROBE REPLACEMENT DUE TO TAT PROBE MESSAGE AND AUTOTHROTTLES DISCONNECTED. THE REASON THE CREW GAVE WAS POSSIBLE ICING CONDITIONS IN FRA
- [SDR DL76L020306](https://openairdocs.org/sdr/DL76L020306), Mar 12, 2002: BLADE. DAMAGED. JFK MTC FOUND SURGE MESSAGE ON EICAS. MTC THEN BORESCOPED ENGINE FOUND COMPRESSOR BLADE DAMAGE. REPLACED RT ENGINE PER TRANSMITTAL 1T149.
- [SDR DL76L011753](https://openairdocs.org/sdr/DL76L011753), Nov 2, 2001: SHUTOFF VALVE. MALFUNCTIONED. LEFT DUCT PRESS FLUCTUATED PLUS/MINUS 15 PSI DURING CLIMBOUT. RETURNED TO JFK. REPLACED PRV CONTROLLER AND PRSOV VLV PER M/M. T/O PWR RUN PER PFHB, ALL NORMAL.
- [SDR DL76L010889](https://openairdocs.org/sdr/DL76L010889), Jun 1, 2001: CHARGER. FAILED. CREW REPORTED BATTERY CHARGER MSG WITH VOLTAGE AT 24 VOLTS. REPLACED BATTERY CHARGER.
- [SDR DL76L992106](https://openairdocs.org/sdr/DL76L992106), Sep 18, 1999: WIRE. CHAFED. INSP WIRING FOR LEFT ENG EEC, FOUND DAMAGE TO LEFT ENG CONTROL WIRE. MADE APPROVED REPAIR PER BOEING WIRING STD PRACTICE MNL, FW TO MCO.
- [SDR DL76L991247](https://openairdocs.org/sdr/DL76L991247), Jun 2, 1999: ACTUATOR. DAMAGED. EICAS C HYD QTY MSG AND CENTER HYD QTY .45. TURNED CENTER ELEC PUMPS OFF, LEAK CONTINUED. TURNED CENTER DEMAND PUMP OFF. FLUID SLOWLY DECREASED .01 PER 20 MINS.
- [SDR DL76L991241](https://openairdocs.org/sdr/DL76L991241), Jun 1, 1999: ACTUATOR. LEAKING. CENTER SYS HYD QUANTITY DROPPED INFLT TO .38. SHUTOFF PUMPS AND QTY STABILIZED. FOUND RT ELEV PCA LEAKING. REPLACED SAME.
- [SDR DL76L991229](https://openairdocs.org/sdr/DL76L991229), Jun 1, 1999: ACTUATOR. LEAKING. RT HYD QTY DROPPED TO BELOW .5, RT HYD SYSTEM RSVR LIGHT AND RT HYD QTY MESSAGE. SECURED PRI PUMP AND DEMAND PUMP PER POM AND QTY STABLIZED AT .3. DIVERTED TO J
- [SDR DL76L991165](https://openairdocs.org/sdr/DL76L991165), May 24, 1999: HYD SYST. REQUIRED SERVICE. RIGHT HYD SYS RSVR LIGHT AND RIGHT HYD QUANT EICAS MESSAGE. SECURED RT PRIM PUMP AND DEMAND PUMP AS PER ABN PROC QTY CONT TO DROP. LEFT BOTH PUMPS OFF QTY STAB 
- [SDR DL76L991142](https://openairdocs.org/sdr/DL76L991142), May 23, 1999: BATTERY PACK. DISCHARGED. EMERGENCY PATH LIGHTS LT SIDE BUSINESS CLASS FROM ROW 6 TO FIRST ROW T/C INOP. REPLACED BATTERY PACK AT 6 A/B, CKS OK.
- [SDR DL76L990598](https://openairdocs.org/sdr/DL76L990598), Mar 20, 1999: PUMP. FAILED. RIGHT SYSTEM HYDRAULIC QTY STARTED TO DROP SLOWLY. TURNED ENGINE DRIVEN PUMP OFF AND QTY STILL DROPPED SLOWLY. QTY STOPPED DROPPING AT 0.12. FOUND ENG DRIVEN HY
- [SDR DL76L990069](https://openairdocs.org/sdr/DL76L990069), Jan 11, 1999: SPAR WEB. CRACKED. PYLON NR 1 ENGINE STRUT AFT UPPER SPAR WEB, STA 222, LBL 4 CRACK REPAIR. THE AFT UPPER SPAR WEB OF THE NR 1 ENGINE PYLON STRUT WAS FOUND WITH .5 CRACK IN THE AF
- [SDR DL76L981856](https://openairdocs.org/sdr/DL76L981856), Sep 8, 1998: BULB. FAILED. ON LAYOVER, FOUND LEFT OVERWING EMERGENCY EXIT LIGHT INOP. REPLACED BULB.
- [SDR DL76L981050](https://openairdocs.org/sdr/DL76L981050), May 17, 1998: BATTERY CHARGER. FAILED. DURING L/O, FOUND EMERGENCY AISLE EXIT SIGN INOP RT OVERWING AND AISLE ILLUMINATION LIGHT INOP. REMOVED AND BATTERY CHARGER ASSY, M732. EMERGENCY LIGHTS OP CK G
- [SDR DL76L980893](https://openairdocs.org/sdr/DL76L980893), Apr 27, 1998: WEDGE. DELAMINATED. WING, NR1 LEADING EDGE SLAT, TRAILING EDGE WEDGE. DELAMINATION REPAIR A 1.5 BY 1.2 AREA OF DELAMINATION WAS FOUND ON THE UPPER SURFACE OF THE TRAILING EDGE WEDG
- [SDR DL76L980671](https://openairdocs.org/sdr/DL76L980671), Mar 27, 1998: SEAT ELECT BOX. FAILED. PROBLEM OCCURED 7 HRS INTO FLT, A SMOKE ODOR WAS OBSERVED COMING FROM THE CAPTS SIDE OF THE ACFT NEAR ROW 24. C/B' S WERE NORMAL. THE F/A WERE DIRECTED TO SHUT 
- [SDR DL76L980371](https://openairdocs.org/sdr/DL76L980371), Feb 12, 1998: PUMP. LEAKING. LT HYD SYS QTY DECREASED TO .81, SECURED LT ENG HYD PUMPS. DIVERTED TO LGW. FOUND LEFT ENGINE DRIVEN PUMP LEAKING, REPLACED SAME. OPS CHECK NORMAL.
- [SDR DL76L970578](https://openairdocs.org/sdr/DL76L970578), Mar 29, 1997: DOOR SEAL. OUT OF POSITION. SHORTLY AFTER LEVEL OFF AT FL330, THE CABIN ALTITUDE WARNING CAME ON. CABIN ALTITUDE WAS AT 10,000 FT AND STILL CLIMBING. WENT TO MANUAL FULLY CLOSED AND DESCEN
- [SDR DL76L970217](https://openairdocs.org/sdr/DL76L970217), Feb 4, 1997: SLIDE. FAILED. RIGHT OVERWING ESCAPE SLIDE SQUIB WOULD NOT TEST ON LAYOVER CHECK.
- [SDR DL76L962534](https://openairdocs.org/sdr/DL76L962534), Nov 16, 1996: POWER SUPPLY. INOPERATIVE. ON L/O, FOUND EMERGENCY PATH LIGHTS BETWEEN ROWS 23 AND 28 BOTH AISLE INOP. REPLACED PWR SUPPLY AT ROW 28A, OPS CK OK.
- [SDR DL76L961673](https://openairdocs.org/sdr/DL76L961673), Jul 10, 1996: CDU. FAILED. LEFT CDU FAILED 1 HR AFTER T/O. PULLED C/B AND LEFT OUT FOR 20 MINS, RESET AND CDU DID NOT WORK. RETURNED TO JFK. REPLACED LEFT CDU, OPS CHECK GOOD.
- [SDR DL76L961302](https://openairdocs.org/sdr/DL76L961302), May 27, 1996: FMC. FAILED. RT FMC LOCKED UP THEN LEFT FMC LOCKED. AFTER A PERIOD OF TIME, BOTH RESUMED NORMAL OPERATION FOR APPROXIMATELY 2 MINUTES, THEN RT FMC FAILED. THEN LEFT FMC FAIL
- [SDR DL76L960505](https://openairdocs.org/sdr/DL76L960505), Mar 5, 1996: SKIN. CRACKED. TWO ADDITIONAL CRACKS WERE FOUND AT HMV, 2/96. ONE CRACK IS IN THE NR 2 PYLON, RT SKIN AND DOUBLER, AND IS 1.38 INCHES LONG, RUNNING DIAGONALLY UP AND AFT FROM 
- [SDR DL76L960239](https://openairdocs.org/sdr/DL76L960239), Jan 25, 1996: SKIN. CRACKED. AT LETTER CHECK IN DFW, A .5 INCH CRACK WAS FOUND IN THE NR 2 ENGINE PYLON OUTBOARD STRUT SKIN. THE CRACK EMANATES FROM THE FORWARD TORQUE BOX ACCESS HOLE AT TH
- [SDR DL76L960186](https://openairdocs.org/sdr/DL76L960186), Jan 24, 1996: SLIDE RELAY. DEFECTIVE. ON ALL CABIN SERVICE AND ENTRY DOORS, THE SLIDE ARMED LIGHT WILL NOT FLASH IN ARMED MODE WITH THE HANDLE SLIGHTLY PULLED. REPLACED DEFECTIVE RELAY, OPERATION NO
- [SDR DL76L953235](https://openairdocs.org/sdr/DL76L953235), Jul 29, 1995: SENSOR. FAILED. AFTER DEPARTING JFK HAD LAV SENSOR FOUL LIGHT WITH F/C RT AFT AND FWD MID LAVATORIES INOP, RETURNED JFK. REPLACED CONTROL MODULE AND SENSORS, OPERATION NORMAL.
- [SDR DL76L952950](https://openairdocs.org/sdr/DL76L952950), Jul 1, 1995: HPT BLADE. MISSING. DURING BORESCOPE INSPECTION, FOUND AN HPT BLADE MISSING. ENGINE WAS REMOVED AND ROUTED TO SHOP.
- [SDR DL76L950627](https://openairdocs.org/sdr/DL76L950627), Feb 13, 1995: ENGINE. HIGH OIL CONSUMP. AFTER REVIEWING OIL CONSUMPTION HISTORY, IT WAS DETERMINED CONSUMPTION RATE WAS BEYOND LIMITS, ENGINE WAS REMOVED AND ROUTED TO SHOP.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
