- [SDR DL76L081773](https://openairdocs.org/sdr/DL76L081773.md): Actuator · frozen · Dec 21, 2008 · N173DN · Boeing 767332 · Air Distribution System
  > RIGHT PACK WAS PUTTING OUT EXCESSIVE TEMP AIR MAIN CABIN WAS 87. ONLY WAY TO CONTROL CABIN TEMP WAS TO SHUT OFF RIGHT PACK. TEMP RETURNED TO NORMAL WITH PACK OFF. T/S IAW FIM BITE PERFORMED ON PACK TEMP CONTROL BOX ALL OK. INSP RT PACK FOUND RT RAM AIR EXT
- [SDR DL76L081768](https://openairdocs.org/sdr/DL76L081768.md): Engine · malfunctioned · Dec 18, 2008 · N173DN · Boeing 767332 · Engine (Turbine/Turboprop)
  > NR 2 ENG CHANGE DUE TO STAGGER. INSTALLED S/N 724715.
- [SDR DL76L081767](https://openairdocs.org/sdr/DL76L081767.md): Engine · malfunctioned · Dec 18, 2008 · N173DN · Boeing 767332 · Engine (Turbine/Turboprop)
  > NR 1 ENG CHANGE FOR STAGGER, INSTALLED S/N 727678.
- [SDR DL76L081710](https://openairdocs.org/sdr/DL76L081710.md): Computer · malfunctioned · Dec 10, 2008 · N173DN · Boeing 767332 · Elevator Control System
  > AFTER PUSHBACK GOT STATUS MSG ELEV FEEL, IT CLEARED AFTER STARTING BOTH ENGINES READ NEEDED HYD PRESSURE IN MDM. AFTER A COUPLE OF MINUTES IT RETURNED AND WOULD NOT CLEAR. MSG FIRST APPEARED AFTER STARTING FIRST ENGINE. REMOVED AND INSTALLED ELEV FEEL COMPU
- [SDR DL76L080730](https://openairdocs.org/sdr/DL76L080730.md): Wire · chafed · May 13, 2008 · N173DN · Boeing 767332 · Engine Oil System Wiring
  > WHEN THROTTLES ADVANCED FOR TAKEOFF RT ENG OIL PSI LIGHT ILLUMINATED AND RT ENG OIL PSI EICAS MSG ANNUNCIATED, LIGHT EXT WITH THROTTLES AT IDLE, RE-ILLUMINATED EACH TIME THROTTLE IS ADVANCE OIL PSI INDICATES NORMAL. INSP MAIN ENG OIL FILTER CHIP DETECTORS NO
- [SDR DL76L071168](https://openairdocs.org/sdr/DL76L071168.md): Wire Harness · damaged · Sep 2, 2007 · N173DN · Boeing 767332 · APU System Wiring
  > DURING DRC CHECK, FOUND APU EGT HARNESS BURNED WIRE INSULATION DAMAGED EXHAUST LEAK. REMOVED AND REPLACED APU PER OPN 6051 AND OPN 7951.
- [SDR DL76L070384](https://openairdocs.org/sdr/DL76L070384.md): Angle · cracked · Apr 27, 2007 · N173DN · Boeing 767332 · Nacelle/Pylon, Plate/Skin
  > THE NR 2 PYLON CLOSEOUT ANGLE WAS FOUND WITH A CRACK IN THE OUTBOARD SIDE. THE MIDSPAR FITTINGS ALSO HAD TOOLING DAMAGE. THE DAMAGED ANGLE WAS REPAIRED WITH REPAIR STRAPS.
- [SDR DALA1108510173](https://openairdocs.org/sdr/DALA1108510173.md): Fitting · damaged · Apr 19, 2007 · N173DN · Boeing 767332 · Trailing Edge Flaps
  > FLAP COLLAR FITTING REPLACED IAW EA 01-073591-12, ME12, ME13, ME20, ME21.
- [SDR DL76L070321](https://openairdocs.org/sdr/DL76L070321.md): Relay · unknown · Apr 14, 2007 · N173DN · Boeing 767332 · Pitot/Static Anti-Ice System
  > LT ENG EEC MODE STATUS. REPLACED K402 RELAY FOR THE LT ENG PROBE HEAT. RAN ENG, OP CKS GOOD.
- [SDR DL76L070047](https://openairdocs.org/sdr/DL76L070047.md): Wire · chafed · Jan 19, 2007 · N173DN · Boeing 767332 · Turbine Engine System Wiring
  > DURING BRAKE RELEASE WHILE PUSHING THROTTLES FORWARD AT APPROX 1.3 EPR, THE RIGHT ENG OIL PRESSURE LIGHT ILLUMINATED AND PRESSURE GAUGE READ AT APPROX 213PSI. IMMEDIATE ABORT PERFORMED. AT IDLE RIGHT ENG OIL PRESS IS NORMAL APPROX 106 PSI. R ENG OIL PRESS E
- [SDR DL76L060670](https://openairdocs.org/sdr/DL76L060670.md): Display · inoperative · Aug 21, 2006 · N173DN · Boeing 767332 · Flight Management Computing Hardware System
  > F/O MCDU FROZE. UNABLE TO HAVE A SUCCESSFUL RESET. DIVERTED TO JFK WHERE PARTS ARE AVAIL. REMOVED AND REPLACED F/O MCDU, OPS NORMAL.
- [SDR DL76L060578](https://openairdocs.org/sdr/DL76L060578.md): Fmu · malfunctioned · Jul 11, 2006 · N173DN · Boeing 767332 · Fuel Controlling System
  > DURING ENG START ACHIEVED STARTER CUTOUT THEN N2 ROLLED BACK REPLACED FMU AND PUMP. C/W LEAK CK. BORO INSP NR 2 ENG, OPS CK ENG START AND OPS PER MM. OK FOR SERVICE.
- [SDR DL76L060370](https://openairdocs.org/sdr/DL76L060370.md): Lamp · inoperative · May 11, 2006 · N173DN · Boeing 767332 · Emergency Lighting
  > FOUND LT SIDE EMERGENCY OVERWING LIGHT INOP. RELAMPED CKS OK.
- [SDR DL76L060273](https://openairdocs.org/sdr/DL76L060273.md): Engine · shutdown · Apr 15, 2006 · N173DN · Boeing 767332 · Engine (Turbine/Turboprop)
  > AT GATE WITH LT ENG RUNNING LT BLEED ON AND 1 PACK RUNNING ENG BEGAN TO VIB THEN SHUTDOWN. BOOST PUMPS WERE TURNED OFF JUST PRIOR TO SHUTDOWN. PERFORMED BITE OF LT ENG PIMU. FAULTED 354-26 EEC CH A/B 28V PERF SOL PWR MSG CLEARED. INSPECTED INLET AND TAILPI
- [SDR DL76L050747](https://openairdocs.org/sdr/DL76L050747.md): Angle · cracked · Nov 27, 2005 · N173DN · Boeing 767332 · Nacelle/Pylon Miscellaneous Structure
  > NR 1 ENGINE PYLON MID SPAR CLOSE OUT ANGLE WAS FOUND CRACKED. REPLACED CRACKED MID SPAR CLOSE OUT ANGLE AND INSPECTED MID SPAR FITTINGS, REF AD 2005-19-23.
- [SDR DL76L050454](https://openairdocs.org/sdr/DL76L050454.md): Battery · inoperative · Aug 15, 2005 · N173DN · Boeing 767332 · Emergency Lighting
  > IR - ON L/O, FOUND EMERGENCY EXIT SIGNS AT DOOR 1L AND 1R. REMOVED AND REPLACED BATTERY PACK FOR DOOR 1L AND 1R EXIT SIGNS, NOW OPS NORMAL.
- [SDR DL76L050448](https://openairdocs.org/sdr/DL76L050448.md): Oven · smoke · Aug 11, 2005 · N173DN · Boeing 767332 · Buffet/Galleys
  > BOTH AFT GALLEY OVENS PRODUCED SMOKE. C/BS PULLED. CKD OVENS FOUND BUN BEHIND THE TRAY. OPERATED FOR 30 MINS. OPS NORM, OVEN CLEANED.
- [SDR DL76L050127](https://openairdocs.org/sdr/DL76L050127.md): Engine · surges · Feb 23, 2005 · N173DN · Boeing 767332 · Engine (Turbine/Turboprop)
  > DURING T/O FROM ATL, NR 2 ENGINE SURGED APPROX 5 TIMES. AIRCRAFT RETURNED TO ATL. REPLACED ENGINE.
- [SDR DL76L050063](https://openairdocs.org/sdr/DL76L050063.md): Logic Card · failed · Jan 27, 2005 · N173DN · Boeing 767332 · Fire Detection
  > FWD CARGO FIRE WARNING LIGHT AND FIRE BELL ACTIVATED IN FLT. REPLACED M10427 CARD.
- [SDR DL76L040151](https://openairdocs.org/sdr/DL76L040151.md): Latch · corroded · Jan 18, 2004 · N173DN · Boeing 767332 · Doors
  > DURING OFFWING SLIDE COMPARTMENT DOOR LATCH INSPECTION OPN 5894AD, MISC HARDWARE FOUND TO BE CORRODED. REPLACED DELTA PART NUMBERS: 251211768, 011216100, 251210507, 251210349, 011214656, MFG 416T2824-3, 416T2075-1, 416T2836-9, NAS43HT4-10, BACT32G64-1072, 251
- [SDR DL76L030108](https://openairdocs.org/sdr/DL76L030108.md): Engine · damaged · Jan 29, 2003 · N173DN · Boeing 767332 · Engine Cowling System
  > NBR 1 ENGINE STRUCK BY DEICING BUCKET CREATING 1 FT HOLE IN NOSE COWL. REPLACED NBR 1 ENG INLET COWL PER M/M 71-11-01-4
- [SDR DL76L021321](https://openairdocs.org/sdr/DL76L021321.md): Probe · failed · Nov 15, 2002 · N173DN · Boeing 767332 · Outside Air Temperature Indicator/Sensor
  > DIVERTED TO AMS FOR TAT PROBE REPLACEMENT DUE TO TAT PROBE MESSAGE AND AUTOTHROTTLES DISCONNECTED. THE REASON THE CREW GAVE WAS POSSIBLE ICING CONDITIONS IN FRA. REMOVED AND REPLACED TAT PROBE IAW MM 34-12-02-4, TESTED IAW 30-33, OK.
- [SDR DL76L020306](https://openairdocs.org/sdr/DL76L020306.md): Blade · damaged · Mar 12, 2002 · N173DN · Boeing 767332 · Turbine Engine Compressor Section
  > JFK MTC FOUND SURGE MESSAGE ON EICAS. MTC THEN BORESCOPED ENGINE FOUND COMPRESSOR BLADE DAMAGE. REPLACED RT ENGINE PER TRANSMITTAL 1T149.
- [SDR DL76L011753](https://openairdocs.org/sdr/DL76L011753.md): Shutoff Valve · malfunctioned · Nov 2, 2001 · N173DN · Boeing 767332 · Pneumatic Distribution System
  > LEFT DUCT PRESS FLUCTUATED PLUS/MINUS 15 PSI DURING CLIMBOUT. RETURNED TO JFK. REPLACED PRV CONTROLLER AND PRSOV VLV PER M/M. T/O PWR RUN PER PFHB, ALL NORMAL.
- [SDR DL76L010889](https://openairdocs.org/sdr/DL76L010889.md): Charger · failed · Jun 1, 2001 · N173DN · Boeing 767332 · Battery/Charger System
  > CREW REPORTED BATTERY CHARGER MSG WITH VOLTAGE AT 24 VOLTS. REPLACED BATTERY CHARGER.
- [SDR DL76L992106](https://openairdocs.org/sdr/DL76L992106.md): Wire · chafed · Sep 18, 1999 · N173DN · Boeing 767332 · Fuel Controlling System
  > INSP WIRING FOR LEFT ENG EEC, FOUND DAMAGE TO LEFT ENG CONTROL WIRE. MADE APPROVED REPAIR PER BOEING WIRING STD PRACTICE MNL, FW TO MCO.
- [SDR DL76L991247](https://openairdocs.org/sdr/DL76L991247.md): Actuator · damaged · Jun 2, 1999 · N173DN · Boeing 767332 · Elevator Control System
  > EICAS C HYD QTY MSG AND CENTER HYD QTY.45. TURNED CENTER ELEC PUMPS OFF, LEAK CONTINUED. TURNED CENTER DEMAND PUMP OFF. FLUID SLOWLY DECREASED.01 PER 20 MINS. FOUND HYD LEAK FROM LEFT ELEVATOR CENTER PCA. TEFLON SEAL CRACKED FROM ROD. REPLACED PCA PER
- [SDR DL76L991241](https://openairdocs.org/sdr/DL76L991241.md): Actuator · leaking · Jun 1, 1999 · N173DN · Boeing 767332 · Elevator Control System
  > CENTER SYS HYD QUANTITY DROPPED INFLT TO.38. SHUTOFF PUMPS AND QTY STABILIZED. FOUND RT ELEV PCA LEAKING. REPLACED SAME.
- [SDR DL76L991229](https://openairdocs.org/sdr/DL76L991229.md): Actuator · leaking · Jun 1, 1999 · N173DN · Boeing 767332 · Elevator Control System
  > RT HYD QTY DROPPED TO BELOW.5, RT HYD SYSTEM RSVR LIGHT AND RT HYD QTY MESSAGE. SECURED PRI PUMP AND DEMAND PUMP PER POM AND QTY STABLIZED AT.3. DIVERTED TO JFK. LEAK CHECKED RUDDER AREA AND LANDING GEAR WITH SIMULATED RETRACTION, NO LEAKS FOUND. FOUND R
- [SDR DL76L991165](https://openairdocs.org/sdr/DL76L991165.md): Hyd Syst · required service · May 24, 1999 · N173DN · Boeing 767332 · Hydraulic System, Main
  > RIGHT HYD SYS RSVR LIGHT AND RIGHT HYD QUANT EICAS MESSAGE. SECURED RT PRIM PUMP AND DEMAND PUMP AS PER ABN PROC QTY CONT TO DROP. LEFT BOTH PUMPS OFF QTY STAB AT.43. SERVICED RT HYD SYSTEM TO FULL. PRESSURIZED SYSTEM FOR APPROX 2 HRS, VISUALLY INSPECTED
- [SDR DL76L991142](https://openairdocs.org/sdr/DL76L991142.md): Battery Pack · discharged · May 23, 1999 · N173DN · Boeing 767332 · Emergency Lighting
  > EMERGENCY PATH LIGHTS LT SIDE BUSINESS CLASS FROM ROW 6 TO FIRST ROW T/C INOP. REPLACED BATTERY PACK AT 6 A/B, CKS OK.
- [SDR DL76L990598](https://openairdocs.org/sdr/DL76L990598.md): Pump · failed · Mar 20, 1999 · N173DN · Boeing 767332 · Hydraulic Pump (Electric/Engine), Main
  > RIGHT SYSTEM HYDRAULIC QTY STARTED TO DROP SLOWLY. TURNED ENGINE DRIVEN PUMP OFF AND QTY STILL DROPPED SLOWLY. QTY STOPPED DROPPING AT 0.12. FOUND ENG DRIVEN HYD PUMP LEAKING AT CASE SPLIT LINE. REPLACED PUMP ASSY. ALSO, REPLACED PRESSURE FILTER AND CASE
- [SDR DL76L990069](https://openairdocs.org/sdr/DL76L990069.md): Spar Web · cracked · Jan 11, 1999 · N173DN · Boeing 767332 · Nacelle/Pylon Structure
  > PYLON NR 1 ENGINE STRUT AFT UPPER SPAR WEB, STA 222, LBL 4 CRACK REPAIR. THE AFT UPPER SPAR WEB OF THE NR 1 ENGINE PYLON STRUT WAS FOUND WITH.5 CRACK IN THE AFT, OUTBD CORNER OF THE ECS DUCT CUTOUT AT STA 222 AND LBL 4. THE CRACK WAS ROUTED OUT WITH A SMOOT
- [SDR DL76L981856](https://openairdocs.org/sdr/DL76L981856.md): Bulb · failed · Sep 8, 1998 · N173DN · Boeing 767332 · Emergency Lighting
  > ON LAYOVER, FOUND LEFT OVERWING EMERGENCY EXIT LIGHT INOP. REPLACED BULB.
- [SDR DL76L981050](https://openairdocs.org/sdr/DL76L981050.md): Battery Charger · failed · May 17, 1998 · N173DN · Boeing 767332 · Emergency Lighting
  > DURING L/O, FOUND EMERGENCY AISLE EXIT SIGN INOP RT OVERWING AND AISLE ILLUMINATION LIGHT INOP. REMOVED AND BATTERY CHARGER ASSY, M732. EMERGENCY LIGHTS OP CK GOOD. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPS.
- [SDR DL76L980893](https://openairdocs.org/sdr/DL76L980893.md): Wedge · delaminated · Apr 27, 1998 · N173DN · Boeing 767332 · Leading Edge Devices
  > WING, NR1 LEADING EDGE SLAT, TRAILING EDGE WEDGE. DELAMINATION REPAIR A 1.5 BY 1.2 AREA OF DELAMINATION WAS FOUND ON THE UPPER SURFACE OF THE TRAILING EDGE WEDGE ON THE NR 1 SLAT. THE DELAMINATION WAS REPAIRED PER THE B676 SRM 57-43-02 AND DOCUMENTED PER
- [SDR DL76L980671](https://openairdocs.org/sdr/DL76L980671.md): Seat Elect Box · failed · Mar 27, 1998 · N173DN · Boeing 767332 · Passenger Compartment Equipment
  > PROBLEM OCCURED 7 HRS INTO FLT, A SMOKE ODOR WAS OBSERVED COMING FROM THE CAPTS SIDE OF THE ACFT NEAR ROW 24. C/B' S WERE NORMAL. THE F/A WERE DIRECTED TO SHUT OFF POWER TO THE MID GALLEY AND PAX ENTERTAINMENT SYSTEM. THE ODOR DISSIPATED SHORTLY THEREAFTER.
- [SDR DL76L980371](https://openairdocs.org/sdr/DL76L980371.md): Pump · leaking · Feb 12, 1998 · N173DN · Boeing 767332 · Hydraulic Pump (Electric/Engine), Main
  > LT HYD SYS QTY DECREASED TO.81, SECURED LT ENG HYD PUMPS. DIVERTED TO LGW. FOUND LEFT ENGINE DRIVEN PUMP LEAKING, REPLACED SAME. OPS CHECK NORMAL.
- [SDR DL76L970578](https://openairdocs.org/sdr/DL76L970578.md): Door Seal · out of position · Mar 29, 1997 · N173DN · Boeing 767332 · Electrical/Electronic Compartment Doors
  > SHORTLY AFTER LEVEL OFF AT FL330, THE CABIN ALTITUDE WARNING CAME ON. CABIN ALTITUDE WAS AT 10,000 FT AND STILL CLIMBING. WENT TO MANUAL FULLY CLOSED AND DESCENDED TO 10,000 FT TO MAINTAIN A CABIN ALTITUDE OF 5700 FT. UNABLE TO FURTHER DESCEND CABIN. FLT A
- [SDR DL76L970217](https://openairdocs.org/sdr/DL76L970217.md): Slide · failed · Feb 4, 1997 · N173DN · Boeing 767332 · Escape Slide
  > RIGHT OVERWING ESCAPE SLIDE SQUIB WOULD NOT TEST ON LAYOVER CHECK.
- [SDR DL76L962534](https://openairdocs.org/sdr/DL76L962534.md): Power Supply · inoperative · Nov 16, 1996 · N173DN · Boeing 767332 · Emergency Lighting
  > ON L/O, FOUND EMERGENCY PATH LIGHTS BETWEEN ROWS 23 AND 28 BOTH AISLE INOP. REPLACED PWR SUPPLY AT ROW 28A, OPS CK OK.
- [SDR DL76L961673](https://openairdocs.org/sdr/DL76L961673.md): Cdu · failed · Jul 10, 1996 · N173DN · Boeing 767332 · Flight Management Computing Hardware System
  > LEFT CDU FAILED 1 HR AFTER T/O. PULLED C/B AND LEFT OUT FOR 20 MINS, RESET AND CDU DID NOT WORK. RETURNED TO JFK. REPLACED LEFT CDU, OPS CHECK GOOD.
- [SDR DL76L961302](https://openairdocs.org/sdr/DL76L961302.md): Fmc · failed · May 27, 1996 · N173DN · Boeing 767332 · Flight Management Computing Hardware System
  > RT FMC LOCKED UP THEN LEFT FMC LOCKED. AFTER A PERIOD OF TIME, BOTH RESUMED NORMAL OPERATION FOR APPROXIMATELY 2 MINUTES, THEN RT FMC FAILED. THEN LEFT FMC FAILED. RE-PROGRAMMED ALL DATA IN FMC. AFTER APPROXIMATELY 2 MINUTES, BOTH FMC'S FAILED AGAIN. ON A
- [SDR DL76L960505](https://openairdocs.org/sdr/DL76L960505.md): Skin · cracked · Mar 5, 1996 · N173DN · Boeing 767332 · Nacelle/Pylon, Plate/Skin
  > TWO ADDITIONAL CRACKS WERE FOUND AT HMV, 2/96. ONE CRACK IS IN THE NR 2 PYLON, RT SKIN AND DOUBLER, AND IS 1.38 INCHES LONG, RUNNING DIAGONALLY UP AND AFT FROM THE UPPER AFT CORNER OF THE FWD TORQUE BOX ACCESS OPENING AT NAC STA 170. THE SECOND CRACK IS IN T
- [SDR DL76L960239](https://openairdocs.org/sdr/DL76L960239.md): Skin · cracked · Jan 25, 1996 · N173DN · Boeing 767332 · Nacelle/Pylon, Plate/Skin
  > AT LETTER CHECK IN DFW, A.5 INCH CRACK WAS FOUND IN THE NR 2 ENGINE PYLON OUTBOARD STRUT SKIN. THE CRACK EMANATES FROM THE FORWARD TORQUE BOX ACCESS HOLE AT THE UPPER FORWARD CORNER AT APPROXIMATELY NAC STA 158 AND EXTENDS DIAGONALLY UPWARD AND FWD TO A FAST
- [SDR DL76L960186](https://openairdocs.org/sdr/DL76L960186.md): Slide Relay · defective · Jan 24, 1996 · N173DN · Boeing 767332 · Emergency Equipment
  > ON ALL CABIN SERVICE AND ENTRY DOORS, THE SLIDE ARMED LIGHT WILL NOT FLASH IN ARMED MODE WITH THE HANDLE SLIGHTLY PULLED. REPLACED DEFECTIVE RELAY, OPERATION NORMAL.
- [SDR DL76L953235](https://openairdocs.org/sdr/DL76L953235.md): Sensor · failed · Jul 29, 1995 · N173DN · Boeing 767332 · Waste Disposal System
  > AFTER DEPARTING JFK HAD LAV SENSOR FOUL LIGHT WITH F/C RT AFT AND FWD MID LAVATORIES INOP, RETURNED JFK. REPLACED CONTROL MODULE AND SENSORS, OPERATION NORMAL.
- [SDR DL76L952950](https://openairdocs.org/sdr/DL76L952950.md): Hpt Blade · missing · Jul 1, 1995 · N173DN · Boeing 767332 · Turbine Section
  > DURING BORESCOPE INSPECTION, FOUND AN HPT BLADE MISSING. ENGINE WAS REMOVED AND ROUTED TO SHOP.
- [SDR DL76L950627](https://openairdocs.org/sdr/DL76L950627.md): Engine · high oil consump · Feb 13, 1995 · N173DN · Boeing 767332 · Turbine Engine Oil System
  > AFTER REVIEWING OIL CONSUMPTION HISTORY, IT WAS DETERMINED CONSUMPTION RATE WAS BEYOND LIMITS, ENGINE WAS REMOVED AND ROUTED TO SHOP.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N173DN' AND deregistration_id = 'N173DN-2017-09-06'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N173DN-2017-09-06/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.