- [SDR UALA2011090904877](https://openairdocs.org/sdr/UALA2011090904877.md): Light · inoperative · Sep 8, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > SEAT 54 EEL LIGHT INOPERATIVE. RELAMPED, CHECKS OKAY.
- [SDR UALA2011090904876](https://openairdocs.org/sdr/UALA2011090904876.md): Light · inoperative · Sep 8, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > SEAT 46L EEL LIGHT INOPERATIVE. RELAMPED, CHECKS OKAY.
- [SDR UALA2011090904875](https://openairdocs.org/sdr/UALA2011090904875.md): Light · inoperative · Sep 8, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > SEAT 39R EEL LIGHT INOPERATIVE. RELAMPED, CHECKS OKAY.
- [SDR UALA2011080804151](https://openairdocs.org/sdr/UALA2011080804151.md): Fire Bottle · discharged · Aug 7, 2011 · N173UA · Boeing 747422 · Fire Bottle, Portable
  > CREW REPORT: PORTABLE HALON BTL IN AFT LAV SELF DISCHARGED. REPLACED AFT CABIN HALON FIRE EXT.
- [SDR UALA2011080304012](https://openairdocs.org/sdr/UALA2011080304012.md): Battery Pack · inoperative · Aug 1, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > UPPER DECK LEFT LIGHT OUT ON PRESSURE GAUGE WHEN EMERGENCY EXIT LIGHTS ON. REPLACED BATTERY PACK, LIGHTS CHECKED OK.
- [SDR UALA2011072003693](https://openairdocs.org/sdr/UALA2011072003693.md): Stringer · corroded · Jul 20, 2011 · N173UA · Boeing 747422 · Fuselage Main, Longeron/Stringer
  > FOUND CORROSION IN STR 51L APPROX STA 1800 TO STA 1820. MAJOR REPAIR ACCOMPLISHED: REPLACED STR 51L FROM STA 1740 TO 1960 REF SFOOV WRITE UP E9664H.
- [SDR UALA2011062903213](https://openairdocs.org/sdr/UALA2011062903213.md): Stringer · corroded · Jun 25, 2011 · N173UA · Boeing 747422 · Fuselage Main, Longeron/Stringer
  > FOUND STR 51R CORRODED BETWEEN STA 1800 TO 1960. SKIN HAS BULGED SKIN AT STA 1944. REPLACED S51R. INSTALLED DOUBLER REPAIR.
- [SDR UALA2011062703177](https://openairdocs.org/sdr/UALA2011062703177.md): Skin · deteriorated · Jun 25, 2011 · N173UA · Boeing 747422 · Wing, Plate/Skin
  > LEFT WING UPPER WING PANEL AT APPROXIMATE LOCATION WS 1056 INBOARD OF NR 1 ENG HAS DETERIORATED SURFACE PROTECTION AND EXPOSED MATERIAL. REPAIRED PER SRM. REPAIR TAP CHECKED GOOD.
- [SDR UALA2011062703176](https://openairdocs.org/sdr/UALA2011062703176.md): Lamp · inoperative · Jun 25, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED
- [SDR UALA2011062703175](https://openairdocs.org/sdr/UALA2011062703175.md): Lamp · inoperative · Jun 25, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED.
- [SDR UALA2011062703174](https://openairdocs.org/sdr/UALA2011062703174.md): Feeder Cable · inoperative · Jun 25, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY EXIT LIGHT INOP DOOR 5 RIGHT GALLEY AREA AFT LOWER WALL. SPLICED NEW CABLE.
- [SDR UALA2011062703173](https://openairdocs.org/sdr/UALA2011062703173.md): Lamp · inoperative · Jun 25, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY EXIT LIGHT INOPERATIVE SEAT ROW 33 LEFT. RELAMPED.
- [SDR UALA2011062703172](https://openairdocs.org/sdr/UALA2011062703172.md): Lamp · inoperative · Jun 25, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED.
- [SDR UALA2011062703171](https://openairdocs.org/sdr/UALA2011062703171.md): Light · missing · Jun 25, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY EXIT LIGHT MISSING DOOR 4 GALLEY AREA LOWER WALL CROSS AISLE. REPLACED LIGHT.
- [SDR UALA2011062103050](https://openairdocs.org/sdr/UALA2011062103050.md): Tire · worn · Jun 17, 2011 · N173UA · Boeing 747422 · Tire Tube
  > GEAR VIBRATION AT 75 KTS UNTIL ABOUT 100KTS ON TAKEOFF. SEEMS TO BE BODY OR WING NOT NOSE. FLT CREW FELT IT AND LASTED AROUND 5 SECONDS EA TIME. GOT VIB AGAIN ON LANDING PER CREW. REPLACED NR 15 & 16 MLG TIRES ON R WING GEAR FOR UNEVEN WEAR.
- [SDR UALA2011042802070](https://openairdocs.org/sdr/UALA2011042802070.md): Light · loose · Apr 27, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > AFT GALLEY EMERGENCY EXIT LIGHT STRIP UNDER FRIG IS LOOSE. SECURED LIGHT STRIP. ALL GALLEY LIGHTS CHECKED, OPS NORMAL.
- [SDR UALA2011041101748](https://openairdocs.org/sdr/UALA2011041101748.md): Fuel/Oil Cooler · leaking · Apr 11, 2011 · N173UA · Boeing 747422 · Engine Fuel/Oil Cooler
  > ON ARRIVAL TO SFO FLIGHT 870-10, NR 2 ENGINE IS STILL LEAKING FUEL ONTO THE RAMP FROM UNDER COWLING. DRY MOTORED NR 2 ENGINE, FOUND IDG AIR-OIL COOLER LEAKING FROM BETWEEN HEAT EXCHANGER AND VALVE BODY AT INBOARD AREA. REMOVED IDG AIR-OIL COOLER ASSEMBLY PER
- [SDR UALA2011040401593](https://openairdocs.org/sdr/UALA2011040401593.md): Connector · damaged · Apr 3, 2011 · N173UA · Boeing 747422 · Light System Wiring
  > EEL SEAT 46ABC INOP. REPAIRED CONNECTOR ON EEL LIGHT, OPS NORMAL.
- [SDR UALA2011040401592](https://openairdocs.org/sdr/UALA2011040401592.md): Light · inoperative · Apr 3, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > LWR AISLE DOOR 2 LT INOPERATIVE. RELAMPED, OPS NORMAL.
- [SDR UALA2011040401591](https://openairdocs.org/sdr/UALA2011040401591.md): Light · inoperative · Apr 3, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > LAV EEL LIGHT DOOR 3 RT INOP. REPLACED EMERGENCY LIGHT PWR STRIP ON FLOOR, OPS CHECK OKAY.
- [SDR UALA2011021600812](https://openairdocs.org/sdr/UALA2011021600812.md): Charger · failed · Feb 16, 2011 · N173UA · Boeing 747422 · Battery/Charger System
  > AFTER STBY BAT TEST BAT DISCHARGE MAIN EICAS MSG COMES BACK ON FOR 10 TO 15 SEC INTERMITTENT. REPLACED MAIN BATTERY CHARGER AND TESTS OK IAW MM.
- [SDR UALA2011020100556](https://openairdocs.org/sdr/UALA2011020100556.md): Controller · faulty · Jan 31, 2011 · N173UA · Boeing 747422 · Windshield/Door Rain/Ice Removal
  > LEFT WINDOW HEAT CONTROL FAILED. LT WINDOW HEAT CONTROLLER REPLACED WITH QF LOAN ITEM. MR30408 DASH 13 OFF. P-NO. ON: 2915-5 SN ON 1428. OPS CK OK.
- [SDR UALA2011012700464](https://openairdocs.org/sdr/UALA2011012700464.md): Battery · discharged · Jan 26, 2011 · N173UA · Boeing 747422 · Battery/Charger System
  > STANDBY TEST FAILED. MAIN BATTERY CHARGER SHOWED ONLY 25 AMPS CHARGING. REPLACED MAIN BATTERY IAW MM24-31-01-401 & MAIN BATTERY CHARGER IAW MM. SYS NORMAL.
- [SDR UALA2011011400227](https://openairdocs.org/sdr/UALA2011011400227.md): Light · corroded · Jan 13, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > DOOR 4 GALLEY LWR WALL LIGHT IS FAULTY. REPLACED CORRODED POWER EEL STRIPPING.
- [SDR UALA2011011400231](https://openairdocs.org/sdr/UALA2011011400231.md): Lamp · inoperative · Jan 13, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY LIGHT AT 33 LEFT INOPERATIVE. REPLACED LAMP ASSY.
- [SDR UALA2011011400230](https://openairdocs.org/sdr/UALA2011011400230.md): Lamp · inoperative · Jan 13, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > 33HJK SEAT EMERGENCY LIGHT INOPERATIVE. RELAMPED.
- [SDR UALA2011011400229](https://openairdocs.org/sdr/UALA2011011400229.md): Lamp · inoperative · Jan 13, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > SEAT 45 LEFT. RELAMPED.
- [SDR UALA2011011400228](https://openairdocs.org/sdr/UALA2011011400228.md): Lamp · inoperative · Jan 13, 2011 · N173UA · Boeing 747422 · Emergency Lighting
  > DOOR 4 LEFT BUSTLE. RELAMPED.
- [SDR UALA2010123004769](https://openairdocs.org/sdr/UALA2010123004769.md): Light · loose · Dec 30, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY LIGHT STRIP ALONG LAV WALL BY DOOR 1R IS FALLING OFF THE WALL AND WIRES EXPOSED. EMERGENCY LIGHT STRIP RESECURED, OPS NORMAL.
- [SDR UALA2010122804750](https://openairdocs.org/sdr/UALA2010122804750.md): Cart · failed · Dec 27, 2010 · N173UA · Boeing 747422 · Buffet/Galleys
  > PIG TAIL P42, INOP, HAS ELECTICAL ODOR, AND HOT TO THE TOUCH. COMPLIED WITH MEL PROC, D. CYC: TEST PASS IAW NEW GALLEY CART TESTER, SUSPECT CART WAS BAD.
- [SDR UALA2010120704478](https://openairdocs.org/sdr/UALA2010120704478.md): Battery · failed · Dec 6, 2010 · N173UA · Boeing 747422 · Battery/Charger System
  > STANDBY TEST FAILED. MAIN BATTERY CHARGER DOES NOT CHARGE BATTERY. CHARGER & BATTERY FOUND FAULTY. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER. OPS ARE NORMAL.
- [SDR UALA2010120104419](https://openairdocs.org/sdr/UALA2010120104419.md): Channel · damaged · Nov 30, 2010 · N173UA · Boeing 747422 · Escape Slide
  > NR5 LT MED SLIDE PACK BUSTLE, AFT SECURING LATCH DOES NOT SECURE IN LATCHED POSITION. LATCH REMOVED FOR REPAIR. MANUFACTURED & INSTALLED NEW CHANNEL. ACCOMPLISH RII OF DOOR 5L SLIDE ASSY DUE TO REMOVAL FOR DOOR MX. DOOR 5LT EVAC SLD INSTALLED CORRECTLY IAW
- [SDR UALA2010113004395](https://openairdocs.org/sdr/UALA2010113004395.md): Battery Pack · inoperative · Nov 30, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > UPPER DECK CEILING EXIT SIGN IS INOP. REPLACED EXIT BATTERY PACK, OPS CK OKAY.
- [SDR UALA2010113004394](https://openairdocs.org/sdr/UALA2010113004394.md): Connector · damaged · Nov 30, 2010 · N173UA · Boeing 747422 · Light System Wiring
  > SEAT 45 ABC EMERGENCY LIGHT IS INOP. SUPPLEMENTAL DATA UPDATE, REPAIRED CONNECTOR TO EMERGENCY LIGHT UNDER SEAT, OPS CK OK.
- [SDR UALA2010113004393](https://openairdocs.org/sdr/UALA2010113004393.md): Lamp · inoperative · Nov 30, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > SEAT 40HJK EMERGENCY LIGHT IS INOPERATIVE. REPLACED EMERGENCY LIGHT LAMP, OPS CK OK.
- [SDR UALA2010113004392](https://openairdocs.org/sdr/UALA2010113004392.md): Wire · damaged · Nov 30, 2010 · N173UA · Boeing 747422 · Light System Wiring
  > SEAT 43 ABC EMERGENCY LIGHT IS INOP. SUPPLEMENTAL DATA UPDATE, REPAIRED WIRE TO EMERGENCY LIGHT, OPS CHECK OKAY.
- [SDR UALA2010113004391](https://openairdocs.org/sdr/UALA2010113004391.md): Battery · discharged · Nov 30, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > UPPER DECK SEAT EMERGENCY LIGHT 14AB INOP. BATTERY CHARGED UP. TURNED ON EMERGENCY LIGHTS. CHECKS NORMAL.
- [SDR UALA2010113004390](https://openairdocs.org/sdr/UALA2010113004390.md): Battery · discharged · Nov 30, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > UPPER DECK SEAT EMERGENCY LIGHTS 13AB IS INOP. BATTERY CHARGED UP. TURNED EMERGENCY LIGHTS ON. CHECKS NORMAL.
- [SDR UALA2010111004175](https://openairdocs.org/sdr/UALA2010111004175.md): Girt Bar · out of position · Nov 10, 2010 · N173UA · Boeing 747422 · Emergency Equipment
  > DOOR 5 RT SIDE WILL NOT DISARM OR ARM. FOUND THAT THE FORWARD SIDE OF THE GIRT BAR HAD JUMPED OUT OF ALIGNMENT. PLACED BACK INTO ALIGNMENT, OPS NORMAL.
- [SDR UALA2010110804144](https://openairdocs.org/sdr/UALA2010110804144.md): Light · loose · Nov 8, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY PATH LIGHTING AT LAV 101 IS LOOSE. SECURED LOOSE EMERGENCY PATH LIGHT AT LAV 101.
- [SDR UALA2010100403660](https://openairdocs.org/sdr/UALA2010100403660.md): Fuel Tank · leaking · Oct 3, 2010 · N173UA · Boeing 747422 · Fuel Storage
  > RAMP REPORTED FUEL COMING OUT OF FWD SMALL HOLE ON APU DRAIN MASK. WHILE IN STAB COMPARTMENT, OBSERVED RUNNING FUEL LEAK (ALMOST A STEADY STREAM) FROM THE AFT LT CORNER OF CTR SECTION OF STABILIZER TANK. FUEL IS EXITING ACFT FROM FUSELAGE DRAINS AND DRAIN HO
- [SDR UALA2010091603438](https://openairdocs.org/sdr/UALA2010091603438.md): Light · loose · Sep 14, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > EXIT PATH LIGHTING IS LOOSE AT LAV100 BY DOOR 1 LT. INTERIM REPAIRED WITH TAPE. EXIT PATH LIGHT FUNCTIONS NORMAL. ACCOMPLISHED REPAIR.
- [SDR UALA2010082603154](https://openairdocs.org/sdr/UALA2010082603154.md): Valve · faulty · Aug 25, 2010 · N173UA · Boeing 747422 · Aircraft Fuel Distribution System
  > PRESSURE CHECKED SYS AND FOUND FUEL GOING INTO 2R AND 2M WITH ALL VALVES CLOSED, SUSPECT FUEL GOING INTO 2R AND UNWANTED FUEL TRANSFERRING INTO 2M. REPLACED NR 2 RESERVE FUELING VALVE. OP CHECKED NR 2 RESERVE TANK STILL TAKING FUEL. REMOVED FUEL PANEL 545BB
- [SDR UALA2010082603141](https://openairdocs.org/sdr/UALA2010082603141.md): Battery · faulty · Aug 24, 2010 · N173UA · Boeing 747422 · Battery/Charger System
  > APU BATTERY CHARGER STATUS MSG DISPLAYED AFTER 7.5 HRS OF FLT. VOLTAGE READING 25 DCV. REPLACED APU BATTERY AND BATTERY CHARGER PER MM. REPLACED DM7432B BACKSHELL.
- [SDR UALA2010062102182](https://openairdocs.org/sdr/UALA2010062102182.md): Skin · delaminated · Jun 20, 2010 · N173UA · Boeing 747422 · Wing, Plate/Skin
  > LEFT UPPER WING FIXED T/E PANEL HAS WATER INGRESS AND DELAMINATED IN 2 LOCATIONS. WATER INGESTING FOUND ON LT UPPER WING TE PANEL AT TWO LOCATIONS DIRECTLY BELOW PREVIOUS REPAIR. ONE AREA IS APPROX 10 X 6" AND THE OTHER IS ABOUT 3" DIAMETER, MARKED AREA ON LOW
- [SDR UALA2010061502106](https://openairdocs.org/sdr/UALA2010061502106.md): Wire · burned · Jun 15, 2010 · N173UA · Boeing 747422 · Electrical Power System Wiring
  > FOUND VARIOUS WIRES BURNED AND DAMAGED GOING TO AFT LAV 117 I-OEU DB7506. CABIN SVC ZONE E (A10) CB ON THE P414 PANEL STILL POPS. STARTED REMOVING CLAMPS ABOVE LAV 117 CEILING PANEL TO ACCESS DAMAGED WIRES. REPLACED OEU ABOVE LAV FC3. FOUND WIRES W8851-208&
- [SDR UALA2010061502114](https://openairdocs.org/sdr/UALA2010061502114.md): Skin · delaminated · Jun 14, 2010 · N173UA · Boeing 747422 · Wing, Plate/Skin
  > LT WING FIXED T/E INBD UPPER PANEL HAS A 6X10 AREA OF DELAMINATION. REMOVED TOPCOATS DOWN TOP REVIOUS REPAIRS. TAP TESTED, FOUND NO DELAMINATIONS ON UPPER OR LOWER SKINS AND ATTACHING HARDWARE SECURE. REPAIRED REF UA-EVA-73860.
- [SDR UALA2010061402083](https://openairdocs.org/sdr/UALA2010061402083.md): Light · unsecure · Jun 14, 2010 · N173UA · Boeing 747422 · Emergency Lighting
  > EMERGENCY LIGHT ASSY LOOSE FWD EDGE OF LAV 101 BY DOOR 1 RT. RESECURED UPPER LIGHT ASSY TO FWD EDGE, OPS CK OK.
- [SDR UALA2010061402082](https://openairdocs.org/sdr/UALA2010061402082.md): Feeder Cable · saturated · Jun 14, 2010 · N173UA · Boeing 747422 · Light System Wiring
  > FLOOR EMERG EMERGENCY LIGHT INOP, SEAT 45ABC TO SEAT 53ABC INOP LT. REMOVED WATER UNDER FLOOR MAT.
- [SDR UALA2010061402081](https://openairdocs.org/sdr/UALA2010061402081.md): Feeder Cable · saturated · Jun 14, 2010 · N173UA · Boeing 747422 · Light System Wiring
  > L4 DOOR LOWER EMERGENCY LIGHTS AT GALLEY INOP. CLEANED AND REMOVED WATER UNDER FLOOR MAT.

Next page: https://openairdocs.org/deregistered/N173UA-2012-01-09/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N173UA' AND deregistration_id = 'N173UA-2012-01-09'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N173UA-2012-01-09/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.