# N196UA: 1997 Boeing 747-422, registration cancelled 2014-03-17

- Type: Cancelled registration (FAA registry, deregistered aircraft)
- Cancelled: March 17, 2014
- Status when cancelled: Valid registration
- Airframe: [Boeing 747-422](https://openairdocs.org/model/boeing-747-422) (registry code 1384935)
- Engine: [Pratt & Whitney PW4000 series](https://openairdocs.org/engine/pratt-whitney-pw4000-series) (registry code 52119)
- Data sheets: [TCDS A20WE](https://openairdocs.org/tcds/A20WE) (OpenAirDocs)
- Serial number: 28715
- Year built: 1997
- Type of aircraft: Fixed wing multi engine
- Engine type: Turbo-fan
- Airworthiness: Standard, transport
- Airworthiness date: December 6, 1999
- Certificate issued: March 8, 2012
- Last registry action: March 8, 2012
- Mode S code: A18038
- Owner when cancelled: [Scaled Composites LLC](https://openairdocs.org/faa-owner/SCALED%20COMPOSITES%20LLC)
- Location: [Mojave, CA](https://openairdocs.org/faa-place/CA/Mojave)
- Owner type: Corporation
- Owner's area on the map: 35.0658° N, 118.2218° W: Placed by OpenAirDocs at the center of ZIP code 93501, within about 8 miles (OpenAirDocs). The owner's mailing address, not where the aircraft was based
- The mark today: https://openairdocs.org/aircraft/N196UA
- FAA registry: https://registry.faa.gov/AircraftInquiry/Search/NNumberResult?nNumberTxt=196UA
- Page: https://openairdocs.org/deregistered/N196UA-2014-03-17

From the FAA registry file of November 12, 2026, cancelled registrations. Owners' street addresses are left out. The Mode S code belongs to the N-number, not the airframe.

ADs and bulletins for the Boeing 747-422: https://openairdocs.org/model/boeing-747-422.md

## Service difficulty reports (106, newest 50)

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.

- [SDR 2008UALA05876](https://openairdocs.org/sdr/2008UALA05876), Sep 24, 2008: BATTERY PACK. DISCHARGED. LEFT OVERWING FWD 2 EMERGENCY LIGHT ASSY INOP. REPLACED BATTERY PACK.
- [SDR 2008UALA05875](https://openairdocs.org/sdr/2008UALA05875), Sep 24, 2008: LIGHT. INOPERATIVE. SEAT 4A FWD EEL LIGHT INOP. RELAMPED EMERGENCY LIGHT.
- [SDR 2008UALA05874](https://openairdocs.org/sdr/2008UALA05874), Sep 24, 2008: LIGHT. INOPERATIVE. SEAT 2F FWD EEL LIGHT INOP. RELAMPED EMERGENCY LIGHT.
- [SDR 2008UALA04227](https://openairdocs.org/sdr/2008UALA04227), Aug 11, 2008: CONNECTOR. INOPERATIVE. EMERGENCY LIGHT ROW 55 LT INOP. FOUND LOOSE CONNECTOR. RE-SECURED EEL CONNECTOR. OP CHECK NORMAL.
- [SDR 2008UALA04231](https://openairdocs.org/sdr/2008UALA04231), Aug 11, 2008: CONNECTOR. UNSECURE. EMERGENCY LIGHT ON WALL FWD OF LAV 110 DOOR 2L INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECK NORMAL.
- [SDR 2008UALA04230](https://openairdocs.org/sdr/2008UALA04230), Aug 11, 2008: CONNECTOR. UNSECURE. EMERGENCY LIGHT ON LT WALL LAV 110 DOOR 2L INOP. *S/D* RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECK NORMAL.
- [SDR 2008UALA04229](https://openairdocs.org/sdr/2008UALA04229), Aug 11, 2008: LAMP. INOPERATIVE. EMERGENCY CEILING LIGHT TOP OF STAIRS UPPER DECK INOP. RELAMPED, OP CHECK NORMAL.
- [SDR 2008UALA04228](https://openairdocs.org/sdr/2008UALA04228), Aug 11, 2008: LAMP. INOPERATIVE. EMERGENCY CEILING LIGHT ABOVE ROW 16 INOP. RELAMPED, OP CHECK NORMAL.
- [SDR 2008UALA04226](https://openairdocs.org/sdr/2008UALA04226), Aug 11, 2008: LAMP. INOPERATIVE. EMERGENCY LIGHT ROW 44LT INOP. RELAMPED, OP CHECK NORMAL.
- [SDR 2008UALA04225](https://openairdocs.org/sdr/2008UALA04225), Aug 11, 2008: CHARGER. INOPERATIVE. OVERWING EMERGENCY LIGHT LT 2 TOP INOP. REPLACED BATTERY CHARGER. CHECKS OKAY.
- [SDR 2008UALA03747](https://openairdocs.org/sdr/2008UALA03747), Jul 5, 2008: LAMP. INOPERATIVE. EEL STRIP AT 2A INOP. FOUND LAMP INOP. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.
- [SDR 2008UALA03715](https://openairdocs.org/sdr/2008UALA03715), Jul 3, 2008: SMOKE GOGGLES. DAMAGED. SMOKE GOGGLES DAMAGED OR MISSING. *S/D* SUSPECT PRE FLIGHT CHECKS. REPLACED SMOKE GOGGLES. AC OK FOR SERVICE.
- [SDR 2008UALA03569](https://openairdocs.org/sdr/2008UALA03569), Jun 23, 2008: LIGHT. BROKEN. SEAT 4J EMERGENCY LIGHT BROKEN. FOUND BROKEN LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE. 
- [SDR 2008UALA02920](https://openairdocs.org/sdr/2008UALA02920), May 20, 2008: GIRT BAR. DAMAGED. DOOR 5L, AFT LOWER GIRT BAR MECH CRANK ASSY IS SHEARED OFF. SUSPECT FAULTY GIRT BAR CRANK ASSY. REPLACED GIRT BAR CRANK ASSY OP CHECKED GOOD. AC OK FOR SERVICE.
- [SDR 2008UALA02929](https://openairdocs.org/sdr/2008UALA02929), May 19, 2008: GIRT BAR. FAULTY. DOOR 5L WILL NOT ARM. REPLACED AFT GIRT BAR LATCH MECHANISM CONTROL ROD BELL CRANK OP CHECKED GOOD. AC OK FOR SERVICE.
- [SDR 2008UALA02523](https://openairdocs.org/sdr/2008UALA02523), Apr 29, 2008: CONNECTOR. LOOSE. EMERGENCY EXIT LIGHTING TURNED ON MID FLIGHT ROWS 6-8. SUSPECT LOOSE CONNECTION. SECURED CONNECTION AT BATTERY PACK OP CHECK OK. AC OK FOR SERVICE.
- [SDR 2008UALA01803](https://openairdocs.org/sdr/2008UALA01803), Mar 29, 2008: CONNECTOR. SEPARATED. EEL STRIP INBOARD OF LAV 110 INOP. FOUND EEL CABLE CONNECTION SEPARATED. RECONNECTED AND OP CKD NORMAL
- [SDR 2008UALA01802](https://openairdocs.org/sdr/2008UALA01802), Mar 29, 2008: LIGHT. INOPERATIVE. FOUND SEAT 39ABC EMERGENCY FLOOR LIGHT INOP. REPLACED LIGHT ASSEMBLY OPS CHECKED GOOD. AC OK FOR SERVICE.
- [SDR 2008UALA01801](https://openairdocs.org/sdr/2008UALA01801), Mar 29, 2008: LAMP. INOPERATIVE. CEILING EMERGENCY LIGHT INOP DOOR 3R. SUPPLEMENTAL DATA UPDATE, RELAMP. OPS CHECK OKAY.
- [SDR 2008UALA01210](https://openairdocs.org/sdr/2008UALA01210), Mar 4, 2008: CONNECTOR. LOOSE. FOUND SEVERAL SEAT EEL LIGHTS LOOSE FIRST CLASS SECTION. RESECURED ALL LOOSE CONNECTIONS.
- [SDR 2008UALA00927](https://openairdocs.org/sdr/2008UALA00927), Feb 19, 2008: LIGHT. INOPERATIVE. EMERGENCY LIGHT ROW 5F INOP. RELAMPED EMERGENCY LIGHT.
- [SDR 2008UALA00926](https://openairdocs.org/sdr/2008UALA00926), Feb 19, 2008: CONNECTOR. UNSECURE. EMERGENCY LIGHT ROW 1J INOP. RESECURED CONNECTOR.
- [SDR 2008UALA00925](https://openairdocs.org/sdr/2008UALA00925), Feb 19, 2008: CONNECTOR. UNSECURE. EMERGENCY LIGHT ROW 39 LT INOP. RESECURED CONNECTOR.
- [SDR 2008UALA00924](https://openairdocs.org/sdr/2008UALA00924), Feb 18, 2008: SKIN. CORRODED. FUSELAGE INTERNAL SKIN CORRODED, BS 2080 STR 35R AT WASTE VENT OUTLET. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER/TRIPLER REPAIR.
- [SDR 2008UALA00674](https://openairdocs.org/sdr/2008UALA00674), Feb 5, 2008: BOTTLE. LOW PRESSURE. CREW O2 PRESSURE 1550, SUPPLEMENTAL DATA UPDATE, SUSPECT PRE-FLIGHT CHECKS. SERVICED OXYGEN BOTTLE. AC OK FOR SERVICE.
- [SDR 2008UALA00555](https://openairdocs.org/sdr/2008UALA00555), Jan 29, 2008: DISK. LEAKING. LOW BOTTLE. BURST DISK LEAKING. REPLACED BURST DISK.
- [SDR 2008UALA00297](https://openairdocs.org/sdr/2008UALA00297), Jan 17, 2008: LIGHT. INOPERATIVE. EMERGENCY LIGHT AT SEATS 1A AFT, 35H, 37A & 41H ARE INOP. REPLACED LIGHT ASSEMBLY.
- [SDR 2007UALA05056](https://openairdocs.org/sdr/2007UALA05056), Dec 11, 2007: LIGHT. INOPERATIVE. EMERGENCY LIGHTS INOP.
- [SDR 2007UALA05055](https://openairdocs.org/sdr/2007UALA05055), Dec 11, 2007: LAMP. INOPERATIVE. EMERGENCY LIGHT AFT GALLEY RT BOTTOM WALL INOP. RELAMPED.
- [SDR 2007UALA05054](https://openairdocs.org/sdr/2007UALA05054), Dec 11, 2007: FEEDER CABLE. INOPERATIVE. EMERGENCY LIGHT AT SIDE OF LAV 111 LT BOTTOM WALL INOP. REPLACED EEL CABLE.
- [SDR 2007UALA05053](https://openairdocs.org/sdr/2007UALA05053), Dec 11, 2007: LAMP. INOPERATIVE. EMERGENCY LIGHT ALONG UPPER DECK WALL ACROSS ROW 18 INOP. RELAMPED WALL UNIT.
- [SDR 2007UALA04763](https://openairdocs.org/sdr/2007UALA04763), Nov 19, 2007: O-RING. LEAKING. LEFT UPPER DECK SLIDE AFT BOTTLE PRESSURE READING 1500 PSI NOT WITHIN GREEN BAND. THE O-RING THAT SEALS THE SPOOL WAS LEAKING. REPLACED O-RING.
- [SDR UALA2008111304567](https://openairdocs.org/sdr/UALA2008111304567), Nov 2, 2007: CONTROL UNIT. LEAKING. PAX O2 LOW. RECURRED ON FLT 916-22NOV. REPLACED LEAKING PAX O2 FLOW CONTROL UNIT. LEAK FOUND ON PRESSURE LINE CONNECTED TO THERMAL COMPENSATOR AT CREW O2 BOTTLE
- [SDR 2007UALA04567](https://openairdocs.org/sdr/2007UALA04567), Nov 2, 2007: OXYGEN SYSTEM. READS LOW. PAX O2 LOW. 
- [SDR 2007UALA03951](https://openairdocs.org/sdr/2007UALA03951), Sep 27, 2007: RELAY. FAULTED. LOST PRIMARY FLAPS ON ALT MODE. 10-23-07 REPLACED RELAYS R7515 & R7513 IN PANEL P54 AS PER SSM 27-51-02 & 03 AND PER FIM TASK 27-51 883-8 84. RAN FLAPS ON GROUN
- [SDR 2007UALA03903](https://openairdocs.org/sdr/2007UALA03903), Sep 25, 2007: O-RING. LEAKING. UNWANTED FUEL TRANSFER. NR 2 MAIN TO CENTER 100LBS EVERY 4+ MINUTES. *S/D* FOUND COUPLINGS ON THE SCAVENGE SYSTEM LEAKING IN THIRD BAY, LEFT SIDE, AT THE BOTTOM
- [SDR 2007UALA03852](https://openairdocs.org/sdr/2007UALA03852), Sep 22, 2007: LAMP. INOPERATIVE. EEL AT DOOR 1L SIDEWALL INOP. 10-19-07 RELAMPED. OP CHECKS NORMALLY.
- [SDR 2007UALA03851](https://openairdocs.org/sdr/2007UALA03851), Sep 22, 2007: BATTERY PACK. FAULTY. DOOR 2L SIDEWALL EXIT SIGN INOP. 10-19-07 EXIT SIGN COMES ON AFTER REPLACEMENT OF BATTERY UNIT. OP CHECKS NORMALLY.
- [SDR 2007UALA03850](https://openairdocs.org/sdr/2007UALA03850), Sep 22, 2007: BATTERY PACK. FAULTY. EEL INOP AT LAV 104 SIDEWALL AND SIDEWALL XAISLE BETWEEN DOORS 2L AND 2R. 10-19-07 EEL LIGHTS IN ALL POSITIONS COME ON AFTER REPLACEMENT OF BATTERY-POWER SUPPLY
- [SDR 2007UALA03849](https://openairdocs.org/sdr/2007UALA03849), Sep 22, 2007: POWER SUPPLY. INOPERATIVE. EEL INOP ROWS 6AB-8AB. 10-19-07 REPLACED POWER SUPPLY UNIT AT DOOR 2 LEFT. OP CHECKS NORMALLY.
- [SDR 2007UALA03848](https://openairdocs.org/sdr/2007UALA03848), Sep 22, 2007: WIRE. DISCONNECTED. EEL INOP ROWS 12-14 & 18. 10-19-07 FOUND CABLE DISCONNECTED. RECONNECTED. OP CHECKS NORMALLY. SUSPECT CABLE DISCONNECTED FOR CLEANING/ MTCE AND NOT RECONNECTED.
- [SDR 2007UALA03847](https://openairdocs.org/sdr/2007UALA03847), Sep 22, 2007: CONNECTOR. DISCONNECTED. EEL ADJACENT TO LAV 100 SIDEWALL & UD LAV ARE INOP. 10-19-07 FOUND EEL LAMP DISCONNECTED. RECONNECTED. OP CHECKS NORMALLY. SUSPECT CONNECTOR SNAGED ON CABIN SER
- [SDR 2007UALA03846](https://openairdocs.org/sdr/2007UALA03846), Sep 22, 2007: CONNECTOR. UNSECURE. EEL INOP AT 5E AFT. 10-19-07 SECURED LAMP CONNECTOR. OP CHECKS NORMALLY.
- [SDR 2007UALA03845](https://openairdocs.org/sdr/2007UALA03845), Sep 22, 2007: LAMP. INOPERATIVE. DOOR 3L EMERGENCY FWD SILL LIGHT INOP. 10-19-07 RELAMPED. OP CHECKED OK FOR SERVICE.
- [SDR 2007UALA03844](https://openairdocs.org/sdr/2007UALA03844), Sep 22, 2007: LAMP. INOPERATIVE. EEL AT 35 HJK, 33 ABC, 4E AFT & AT 43 ABC ARE INOPERATIVE. 10-19-07 RELAMPED ALL SEAT POSITION EEL. OP CHECKS GOOD FOR SERVICE.
- [SDR 2007UALA03277](https://openairdocs.org/sdr/2007UALA03277), Aug 19, 2007: LIGHT. INOPERATIVE. DOOR 4R FWD SILL EMERGENCY LIGHT INOPERATIVE. 08-31-07 RELAMPED. OP CHECKED OK FOR SERVICE.
- [SDR 2007UALA03276](https://openairdocs.org/sdr/2007UALA03276), Aug 19, 2007: CONNECTOR. LOOSE. EEL 33 LEFT INOP. 08-31-07 SECURED CONNECTOR TO LAMP. OP CHECKS OK FOR SERVICE.
- [SDR 2007UALA03275](https://openairdocs.org/sdr/2007UALA03275), Aug 19, 2007: LIGHT. INOPERATIVE. EMERGENCY CEILING LIGHT INOP ROW 13. RELAMPED EMERGENCY LIGHT.
- [SDR 2007UALA03274](https://openairdocs.org/sdr/2007UALA03274), Aug 19, 2007: LIGHT. INOPERATIVE. EEL 4J AFT & 39 LEFT ARE INOPERATIVE. RELAMPED EEL.
- [SDR 2007UALA02674](https://openairdocs.org/sdr/2007UALA02674), Jul 16, 2007: LAMP. INOPERATIVE. EMERGENCY CEILING LIGHT ABOVE ROW 48ABC INOPERATIVE. RELAMPED EMERGENCY LIGHT. OP CHECKED NORMAL.

All 106: https://openairdocs.org/deregistered/N196UA-2014-03-17/reports.md

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.