- [SDR CHQA200900051](https://openairdocs.org/sdr/CHQA200900051.md): Light · inoperative · Feb 10, 2009 · N260SK · Emb EMB145LR · Emergency Lighting
  > DURING C-CHECK INSPECTION THE AFT EMERGENCY EXIT LIGHT AT PANEL 253CLC WAS FOUND TO BE INOP. THE NON-ROUTINE WORK CARD HAS NOT BEEN CLEARED AT THIS TIME.
- [SDR CHQA200800237](https://openairdocs.org/sdr/CHQA200800237.md): Connector · loose · Dec 2, 2008 · N260SK · Emb EMB145 · Landing Gear System Wiring
  > ON THE APPROACH, THE CREW RECEIVED A LG AIR/GRND FAIL MESSAGE WHEN THE LANDING GEAR WAS SELECTED DOWN. THE INDICATION CLEARED WHEN ALL GEAR SHOWED GREEN. A NORMAL LANDING WAS MADE WITH NO INCIDENT. A LOOSE CONNECTOR WAS FOUND ON THE RIGHT MAIN LANDING GEAR
- [SDR CHQA200800206](https://openairdocs.org/sdr/CHQA200800206.md): Wire · damaged · Oct 19, 2008 · N260SK · Emb EMB145LR · Light System Wiring
  > FLIGHT 5838, IAH TO STL. THE FLIGHT CREW REPORTED THAT THE EMERGENCY EXIT ROW OVERHEAD LIGHT WAS INOP. MAINTENANCE INSPECTED THE EMERGENCY LIGHT SYSTEM AND FOUND A WIRE AT THE SIGN DAMAGED. THE WIRE WAS REPAIRED AND THE EMERGENCY LIGHTS OPERATED NORMALLY.
- [SDR CHQA200800203](https://openairdocs.org/sdr/CHQA200800203.md): Inverter · inoperative · Oct 18, 2008 · N260SK · Emb EMB145LR · Emergency Lighting
  > FLIGHT 5909, STL TO IAH. DURING TEST THE EMERGENCY LIGHT ON THE LEFT SIDE NEXT TO THE OVERWING EXIT WAS FOUND TO BE INOP. MAINTENANCE SWAPPED EMERGENCY LIGHTS AND SLAVED IN A NEW BATTERY PACK FOR TROUBLESHOOTING WITH NO FIX. THE NR 5 INVERTER WAS THEN REPLA
- [SDR CHQ2008F00002](https://openairdocs.org/sdr/CHQ2008F00002.md): Inverter · inoperative · Aug 22, 2008 · N260SK · Emb EMB145 · Emergency Lighting
  > DURING INSPECTION THE NR 1 PROXIMITY LIGHT STRIP AND THE EMERGENCY LIGHT OVER THE SERVICE DOOR WAS FOUND TO BE INOP. THE NR 2 EMERGENCY LIGHT INVERTER WAS REPLACED IAW AMM 33-50-11. AFTER INVERTER REPLACEMENT, THE EMERGENCY LIGHTS OPERATED NORMALLY.
- [SDR CHQA200800054](https://openairdocs.org/sdr/CHQA200800054.md): Controller · malfunctioned · Mar 17, 2008 · N260SK · Emb EMB145LR · Cabin Pressure Controller
  > CLE TO ATL - DURING FLIGHT, THE AIRCRAFT CABIN WOULD NOT PRESSURIZE FULLY. THE CREW DROPPED BELOW 10,000 FT AND USED THE PRESSURE DUMP TO RELEASE REMAINING PRESSURE AND RETURNED TO CLE. MAINTENANCE TROUBLESHOT THE PRESSURIZATION SYSTEM AND FOUND THE DIGITAL
- [SDR CHQA200600103](https://openairdocs.org/sdr/CHQA200600103.md): Bulb · burned out · Aug 20, 2006 · N260SK · Emb EMB145 · Emergency Lighting
  > SEVERAL EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHTS. OPS CHECK GOOD AT THIS TIME IAW EMB 145 MM 33-50-00.
- [SDR CHQA200600079](https://openairdocs.org/sdr/CHQA200600079.md): Bulb · burned out · Jul 9, 2006 · N260SK · Emb EMB145 · Emergency Lighting
  > LEFT HAND OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED SERVICEABLE EMERGENCY LIGHT IAW EMB 145 MM 33-50-07.
- [SDR CHQA200600062](https://openairdocs.org/sdr/CHQA200600062.md): Light · inoperative · May 14, 2006 · N260SK · Emb EMB145 · Emergency Lighting
  > LEFT HAND WING EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LEFT HAND OVERWING EMERGENCY LIGHT BULB IAW EMB 145 MM 30-50-10-4. FUNCTION CHECKS GOOD.
- [SDR CHQA200600011](https://openairdocs.org/sdr/CHQA200600011.md): Relay · inoperative · Jan 19, 2006 · N260SK · Emb EMB145 · Ice/Rain Protection System Wiring
  > FLIGHT 3290 - RDU-LGA - DURING DESCENT IN ICING CONDITIONS WITH AUTO ANTI-ICE ON, NOTICED A STRONG BURNING SMELL IN COCKPIT AND CABIN. REACHING THE GATE, NOTICED THE SMELL WAS STRONGEST BEHIND FIRST OFFICERS SEAT CIRCUIT BREAKER PANEL. MAINTENANCE REMOVED AN
- [SDR CHQA200600010](https://openairdocs.org/sdr/CHQA200600010.md): Gasper Fan · malfunctioned · Jan 18, 2006 · N260SK · Emb EMB145 · Air Distribution Fan
  > FLIGHT 3170 - ILM-LGA - DURING CLIMB TO CRUISING ALTITUDE, NOTED STRONG ELECTRICAL BURNING SMELL. NO VISIBLE SMOKE. DECLARED EMERGENCY AND LANDED IN RDU. GASPER FAN CURRENTLY ON MEL, BUT STILL RUNNING WHEN SWITCHED OFF. PULLED AND COLLARED CIRCUIT BREAKER
- [SDR CHQA200600009](https://openairdocs.org/sdr/CHQA200600009.md): Odor · detected · Jan 17, 2006 · N260SK · Emb EMB145 · Air Distribution System
  > FLIGHT 3119 - LGA-ILM - AFTER DEPARTING LGA, GASPER FAN ENERGIZED AND ELECTRICAL BURNING SMELL EMANATED FROM GASPER VENTS. NO VISIBLE SMOKE. TURNED OFF GASPER FANS AND RECIRCULATION FANS, SMELL DIMINISHED QUICKLY. FLIGHT ATTENDANT NOTICED ODOR ONLY IN FORWA
- [SDR CHQA200500156](https://openairdocs.org/sdr/CHQA200500156.md): Bulb · burned out · Aug 31, 2005 · N260SK · Emb EMB145LR · Emergency Lighting
  > RIGHT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY IAW EMB 145 MM 33-50-09. OPS CHECK GOOD.
- [SDR CHQA200500142](https://openairdocs.org/sdr/CHQA200500142.md): Engine · unserviceable · Aug 13, 2005 · N260SK · Emb EMB145LR · Engine (Turbine/Turboprop)
  > APPROX 15 MIN INTO FLT RECEIVED AN E2 IMP BYPASS MESSAGE. RAN QRH AND CONTINUED. MESSAGE WENT OUT VERY SHORTLY AFTER IT APPEARED. APPROX 35 MIN INTO FLT, ITT JUMP FROM GREEN INDICATION TO RED AND BACK TO AMBER AND GREEN. PULLED NR 2 THRUST LEVER BACK. ITT
- [SDR CHQA200500117](https://openairdocs.org/sdr/CHQA200500117.md): Light · inoperative · Jun 20, 2005 · N260SK · Emb EMB145LR · Emergency Lighting
  > FLOOR PROXIMITY LIGHT AT POSITION NR 8 WILL NOT ILLUMINATE. REMOVED AND REPLACED FLOOR PROXIMITY LIGHT IAW EMB AMM 33-50-00. OPS CHECK GOOD.
- [SDR CHQA200500015](https://openairdocs.org/sdr/CHQA200500015.md): Connector · loose · Jan 21, 2005 · N260SK · Emb EMB145LR · Landing Gear Position and Warning
  > FLIGHT 3082 - CHS-LGA - AFTER GEAR RETRACTION ON TAKEOFF, LG AIR/GND FAIL MESSAGE APPEARED ON EICAS. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO THE FIELD AND LANDED NORMALLY. MAINTENANCE CLEANED ALL PROXIMITY SWITCHES AND FOUND A LOOSE CONNECTOR
- [SDR CHQA200400564](https://openairdocs.org/sdr/CHQA200400564.md): Static Inverter · faulty · Oct 11, 2004 · N260SK · Emb EMB145LR · Emergency Lighting
  > WHILE PERFORMING AN OPERATIONAL CHECK OF THE EMERGENCY LIGHTING SYSTEM THE EMERGENCY LIGHTS ON THE FLOOR AFT OF THE EMERGENCY EXIT DOORS DID NOT ILLUMINATE ALONG WITH THE EXIT DOOR LOCATOR LIGHTS. REMOVED AND REPLACED STATIC INVERTER NR 5 AND NR 6 IAW EMB 145
- [SDR CHQA000509](https://openairdocs.org/sdr/CHQA000509.md): Power Supply · inoperative · Jun 15, 2004 · N260SK · Emb EMB145LR · Emergency Lighting
  > CABIN FLOOR EMERGENCY LIGHTING FROM ROW 8 TO REAR OF CABIN INOP. REMOVED AND REPLACED POWER SUPPLY NR 4 IAW EMB 145MM 33-50-04. OPERATIONAL CHECK GOOD.
- [SDR CHQ00061](https://openairdocs.org/sdr/CHQ00061.md): Smoke Detector · malfunctioned · Dec 9, 2001 · N260SK · Emb EMB145LR · Smoke Detection
  > AVIONICS SMOKE LIGHT CAME ON INTERMITTENTLY DURING FLIGHT, NO SMOKE OR FIRE DETECTED IN COCKPIT OR CABIN. FOLLOWED CHECKLIST PROCEDURES. REMOVED AND REPLACED AVIONICS SMOKE DETECTOR, OPS CHECK GOOD.
- [SDR CHQ00028](https://openairdocs.org/sdr/CHQ00028.md): Window · noisy · Oct 8, 2001 · N260SK · Emb EMB145 · Flight Compartment Windows
  > FIRST OFFICER SIDE SQUEALS BADLY.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N260SK' AND deregistration_id = 'N260SK-2023-02-02'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N260SK-2023-02-02/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.