# Service difficulty reports: N269UE, cancelled Jul 29, 2004

A list on [N269UE, cancelled Jul 29, 2004](https://openairdocs.org/deregistered/N269UE-2004-07-29.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR SWIA200311697](https://openairdocs.org/sdr/SWIA200311697.md): Actuator · malfunctioned · Jan 8, 2003 · N269UE · Emb EMB120RT · Trailing Edge Flap Actuator
  > FLAP LIGHT ON MAP PANEL ASSOCIATED WITH ADVANCED SWS AND CONTROL FAULT ON OVERHEAD. REPLACED LEFT NACELLE FLAP ACTUATOR PER MM 27-50-00. CYCLED FLAPS SEVERAL TIMES. ALL CHECKS GOOD.
- [SDR SWIA200211497](https://openairdocs.org/sdr/SWIA200211497.md): Control Unit · malfunctioned · Nov 22, 2002 · N269UE · Emb EMB120RT · Trailing Edge Flap Control System
  > FLAPS HAD RT INBOARD FLAP ASYMMETRY WHEN SET FOR LANDING AND FAILED TO RETRACT AFTER LANDING (RT AND LT INBOARD). RE-RACKED FLAP CONTROL UNIT. PERFORMED FUNCTIONAL CHECK OF FLAP SYSTEM. CYCLED FLAPS SEVERAL TIMES. NO DISCREPANCIES NOTED.
- [SDR SWIA200211496](https://openairdocs.org/sdr/SWIA200211496.md): Terminal · broken · Nov 21, 2002 · N269UE · Emb EMB120RT · Electrical Power System Wiring
  > DURING THE TAKEOFF RUN THE NR 1 GEN OFF BUS LIGHT ILLUMINATED. THE TAKEOFF WAS ABORTED. ATTEMPTED RESET PER QRH WITH NO SUCCESS. FOUND BROKEN WIRE ON NR 1 GENERATOR. REPLACED WIRE EYELET WITH SERVICEABLE UNIT AND CONNECTED TO NR 1 GENERATOR. RAN RT ENGINE
- [SDR SWIA200211480](https://openairdocs.org/sdr/SWIA200211480.md): Control Unit · malfunctioned · Nov 14, 2002 · N269UE · Emb EMB120RT · Trailing Edge Flap Control System
  > CONTROL FAULT ON INBOARD FLAPS AFTER TRYING TO RAISE FLAPS. REMOVED AND REPLACED FLAP CONTROL UNIT. FLAPS FUNCTIONAL CHECK GOOD.
- [SDR SWIA200211411](https://openairdocs.org/sdr/SWIA200211411.md): Actuator · malfunctioned · Oct 29, 2002 · N269UE · Emb EMB120RT · Trailing Edge Flap Actuator
  > AFTER FLAP RETRACTION ON LANDING, THE INBOARD PAIR OF FLAPS REMAINED AT 25 DEGREES. THERE WERE NO CONTROL FAULTS OR DISAGREEMENT WARNINGS. AFTER RESETTING THE SYSTEM, THE FLAPS RETRACTED. REPLACED LEFT INBOARD FLAP ACTUATOR WITH SERVICEABLE UNIT IAW MM 27-5
- [SDR SWIA200211112](https://openairdocs.org/sdr/SWIA200211112.md): Warning System · false activation · Aug 6, 2002 · N269UE · Emb EMB120RT · Central Warning
  > ON TAKEOFF GOT TRIPLE CHIME EEC WARNING. ABORTED TAKEOFF. SUSPECT LEFT EEC THE CULPRIT, LOWER NP THAN RT ON FFOD. INSPECTED CANNON PLUGS AND WIRING FOR CHAFING ON LT ENGINE EEC. RAN ENGINE FOR TRIM CHECK AND TAXIED AIRCRAFT. COULD NOT DUPLICATE. OPS CHEC
- [SDR SWIA200210964](https://openairdocs.org/sdr/SWIA200210964.md): Duct · leaking · Jun 25, 2002 · N269UE · Emb EMB120RT · Pneumatic Distribution System
  > AT ABOUT 50 KTS ON TAKEOFF ROLL, TRIPLE CHIME DUCT LEAK RED LIGHT ON MAP AND DUCT LEAKAGE ON LEFT SIDE OVERHEAD. ABORTED TAKEOFF. LIGHTS REMAINED ON FOR ONLY 10-15 SECONDS, THEN WENT OUT. INSTALLED SERVICEABLE LEFT WING BLEED LINE. OPS CHECK GOOD.
- [SDR SWIA200210872](https://openairdocs.org/sdr/SWIA200210872.md): Actuator · malfunctioned · May 25, 2002 · N269UE · Emb EMB120RT · Trailing Edge Flap Actuator
  > LEFT OUTBOARD FLAP DEPLOYED APPROXIMATELY 3 DEGREES (UNCOMMANDED) WHILE FLAP HANDLE IS IN ZERO POSITION. ANALOG INDICATOR SHOWS ZERO DEGREES. FLAP ON MAP ILLUMINATED, ASYMMETRY ON FLAP PANEL INDICATOR ILLUMINATED. REPLACED LEFT OUTBOARD FLAP ACTUATOR PER EM
- [SDR SWIA200210863](https://openairdocs.org/sdr/SWIA200210863.md): Eec · malfunctioned · May 20, 2002 · N269UE · Emb EMB120RT · Fuel Control/Turbine Engines
  > ABORTED TAKEOFF IN FAT DUE TO LEFT EEC FAILURE. RAN NR 1 ENGINE IAW 71-00-00. RAN WITHIN PARAMETERS. OPS CHECKS GOOD AT THIS TIME. NO OTHER DEFECTS NOTED.
- [SDR SWIA200210808](https://openairdocs.org/sdr/SWIA200210808.md): Connector · dirty · Apr 22, 2002 · N269UE · Emb EMB120RT · Fuel Control/Turbine Engines
  > WHILE IN POSITION FOR TAKEOFF, RECEIVED AN AURAL WARNING ENGINE CONTROLS AND MOMENTARY RED EEC LIGHT. CLEANED P1 CONNECTOR OF LEFT AND RIGHT EEC'S. PERFORMED ENGINE RUNS. NO DISCREPANCIES FOUND.
- [SDR SWIA200210673](https://openairdocs.org/sdr/SWIA200210673.md): Door · departed · Feb 23, 2002 · N269UE · Emb EMB120RT · Air Conditioning Doors
  > RIGHT AIR CONDITIONING PACK DOOR DEPARTED WHILE IN FLIGHT. REPLACED PACK DOOR IAW SRM 120 51-10-02.
- [SDR SWIA200210654](https://openairdocs.org/sdr/SWIA200210654.md): Sensor · corroded · Feb 19, 2002 · N269UE · Emb EMB120RT · Elevator Tab Control System
  > TAKEOFF TRIM AURAL WARNING OCCURRED DURING INITIAL PART OF TAKEOFF ROLL. TRIM WAS SET IN THE MIDDLE OF THE GREEN BAND. INSPECTED WIRING AND CLEANED CORROSION AT ELEVATOR TRIM SENSORS. OPERATED SYSTEM, COULD NOT DUPLICATE.
- [SDR SWIA200210672](https://openairdocs.org/sdr/SWIA200210672.md): Fcu · malfunctioned · Feb 17, 2002 · N269UE · Emb EMB120RT · Trailing Edge Flap Control System
  > INBOARD FLAPS DID NOT RETRACT AFTER LANDING. REMOVED AND REPLACED FLAP CONTROL UNIT WITH SERVICEABLE. CYCLED FLAPS SEVERAL TIMES. NO DISCREPANCIES NOTED. OPS CHECK GOOD.
- [SDR SWIA200210659](https://openairdocs.org/sdr/SWIA200210659.md): Warning System · malfunctioned · Feb 16, 2002 · N269UE · Emb EMB120RT · Central Warning
  > ABORTED 3 STATIC TAKEOFFS FOR T/O TRIM AURAL WARNING. TRIM SETTING WAS IN GREEN BAND 30 PERCENT TO 35 PERCENT. CYCLED TRIM WHEEL, THEN NORMAL TAKEOFF. TESTED TRIM AURAL WARNING AT VARIOUS SETTINGS. ALL CHECKS GOOD AT THIS TIME.
- [SDR SWIA200210585](https://openairdocs.org/sdr/SWIA200210585.md): Computer · malfunctioned · Jan 24, 2002 · N269UE · Emb EMB120RT · Central Warning
  > AURAL TRIM INDICATION WITH TRIM IN THE GREEN ON THE TAKEOFF ROLL. RESET AURAL WARNING COMPUTER. OPS CHECK GOOD.
- [SDR SWIA200110318](https://openairdocs.org/sdr/SWIA200110318.md): Sequence Valve · malfunctioned · Nov 4, 2001 · N269UE · Emb EMB120ER · Landing Gear Retraction/Extension System
  > LANDING GEAR WOULD NOT COME DOWN AFTER SELECTING GEAR LEVER DOWN. ALL RED A & B LIGHTS, EXCEPT LEFT MAIN A LIGHT, STAYED ON. LT MAIN GREEN A LIGHT WAS ALSO ILLUMINATED. ON THE GO-AROUND THE GEAR EXTENDED AND GOT NORMAL GREEN LIGHTS EXCEPT LEFT MAIN A LIGHT
- [SDR SWIA200110237](https://openairdocs.org/sdr/SWIA200110237.md): Pump · defective · Oct 9, 2001 · N269UE · Emb EMB120RT · Engine Fuel Pump
  > DURING CLIMB TO 16000 FT NR 2 ENGINE TORQUE FLUCTUATED THEN RAPIDLY DROPPED TO 11 PERCENT TQ. OTHER ENGINE INDICATIONS WERE NORMAL. PERFORMED PRECAUTIONARY ENGINE SHUT DOWN. REMOVED AND REPLACED RIGHT ENGINE HMU AND FUEL PUMP IAW MM 73-21-00. OPS AND LEAK C
- [SDR SWIA200110129](https://openairdocs.org/sdr/SWIA200110129.md): Switch · malfunctioned · Aug 22, 2001 · N269UE · Emb EMB120RT · Door Warning System
  > FORWARD DOOR ACTUATOR LT ON IN FLIGHT. LIGHT EXTINGUISHES ON THE GROUND. COULD NOT GET MAIN CABIN DOOR OPEN NORMALLY ON GROUND. USED EMERGENCY OVERRIDE. REMOVED AND REPLACED PASSENGER DOOR SWITCH AT FLIGHT ATTENDANT'S STATION. SYSTEM OPS CHECK GOOD.
- [SDR SWIA972661](https://openairdocs.org/sdr/SWIA972661.md): Valve · leaking · Jun 29, 2001 · N269UE · Emb EMB120RT · Airfoil Anti/De-ice System
  > DURING CLIMB OUT, DUCT LEAK LIGHT ILLUMINATED FOR RIGHT ENGINE. COMPLIED WITH QRH, NO CHANGE. CLOSED BLEEDS, ALSO THE PACKS. THE LIGHT DID NOT EXTINGUISH UNTIL POWER ON THE RIGHT ENGINE WAS PULLED TO FLIGHT IDLE. RETURNED TO MEDFORD. GAINED ACCESS TO ALL DU
- [SDR SWIA972664](https://openairdocs.org/sdr/SWIA972664.md): Terminal · failed · Jun 28, 2001 · N269UE · Emb EMB120RT · Windshield/Door Rain/Ice Removal
  > RIGHT WINDSHIELD REPORTED NOT FUNCTIONING & BURN SMELL NOTED IN COCKPIT. FOUND BURNED POWER TERMINAL ON RIGHT WINDSHIELD. REMOVED AND REPLACED RIGHT WINDSHIELD PER MM 56-10-01. REMOVED & REPLACED POWER WIRE PER WM 30-41-00. WINDSHIELD HEAT OPS CHECK GOOD.
- [SDR SWIA972663](https://openairdocs.org/sdr/SWIA972663.md): Receptacle · melted · Jun 28, 2001 · N269UE · Emb EMB120RT · AC Power Distribution System
  > ON CLIMB OUT FROM EUGENE, NOTICED BURNING SMELL LIKE BURNING RUBBER IN FLIGHT DECK. SMELL CONTINUED, COULD NOT ISOLATE. NO VISABLE SMOKE. DIVERTED TO PDX. RAN AIRCRAFT FOR 30 MINUTES, COULD NOT DUPLICATE. FOUND FORWARD COFFEE POT ELECTRICAL RECEPTACLE MELT
- [SDR SWIA972467](https://openairdocs.org/sdr/SWIA972467.md): Actuator · failed · Mar 30, 2001 · N269UE · Emb EMB120RT · Trailing Edge Flap Actuator
  > WHEN SELECTING FLAPS 15 DEGREES AND 25 DEGREES AIRCRAFT ROLLS TO THE RIGHT WITH NO FLAP WARNING INDICATIONS. REMOVED AND REPLACED RIGHT OUTBOARD FLAP ACTUATOR. OPS CHECK GOOD. P/N: 320300-1007, S/N ON: 0706, S/N OFF: 0931.
- [SDR SWIA972437](https://openairdocs.org/sdr/SWIA972437.md): Actuator · faulty · Mar 18, 2001 · N269UE · Emb EMB120RT · Trailing Edge Flap Actuator
  > EN ROUTE AT FL230 CONTROL FAULT LIGHT ILLUMINATED, WOULD NOT RESET. WEIGHTED FLAP AVERAGE WAS ZERO. LANDED WITH 0 DEGREES FLAPS. FOUND RIGHT HAND OUTBOARD FLAP ACTUATOR EXTERNAL READING AT 820-R. REMOVED AND REPLACED ACTUATOR. OPS CHECKS ACTUATOR IAW 27-5
- [SDR SWIA972410](https://openairdocs.org/sdr/SWIA972410.md): Switch · out of adj · Feb 27, 2001 · N269UE · Emb EMB120RT · Door Warning System
  > SERVICE DOOR LIGHT ILLUMINATED AGAIN ON TAKEOFF ROLL. REMOVED AND REPLACED SERVICE DOOR LIGHT INDICATOR. INSPECTED SERVICE DOOR MICROSWITCH WIRING FOUND TO BE NORMAL. ADJUSTED OUTBOARD FUEL DOOR MICROSWITCH. OPS CHECK GOOD.
- [SDR SWIA972379](https://openairdocs.org/sdr/SWIA972379.md): Regulator Valve · leaking · Feb 19, 2001 · N269UE · Emb EMB120RT · Turbine Engine Oil System
  > RIGHT ENGINE INFLIGHT SHUTDOWN DUE TO LOW OIL PRESSURE LIGHT ON MAP AND OIL PRESSURE GAUGE BELOW 40 PSI. REMOVED AND REPLACED RIGHT ENGINE OIL PRESSURE REGULATING VALVE ASSEMBLY IAW P&W MM 72-01-50, PAGE 418. PERFORMED ENGINE RUNS AS REQUIRED. OPS CHECK GOO
- [SDR SWIA972310](https://openairdocs.org/sdr/SWIA972310.md): Light · inoperative · Jan 25, 2001 · N269UE · Emb EMB120RT · Emergency Lighting
  > EXIT ROW SIGNS AT 6A AND 6C DO NOT ILLUMINATE CONTINUOUSLY WHEN EMERGENCY LIGHTS SWITCH IS TURNED ON AT FLIGHT ATTENDNATS PANEL. REPLACED ELBP AT ROW 6. OPS CHECKS GOOD. P/N ON,OFF: D366-04-001, S/N ON: 1137, S/N OFF: 1169.
- [SDR SWIA972079](https://openairdocs.org/sdr/SWIA972079.md): Fcu · malfunctioned · Nov 6, 2000 · N269UE · Emb EMB120RT · Trailing Edge Flap Control System
  > CONTROL FAULT WHEN FLAPS WERE SELECTED 45 DEGREES. RERACKED FCU. OPS CHECKS GOOD IAW 27-00-00.
- [SDR SWIA971419](https://openairdocs.org/sdr/SWIA971419.md): Fan · failed · Feb 20, 1999 · N269UE · Emb EMB120RT · Air Distribution System
  > SMOKE IN COCKPIT. RETURNED TO FAT. REPLACED LEFT RECIRCULATION FAN. OPS CHECKED GOOD WITH NO DISCREPANCIES AND NO SMOKE.
- [SDR SWIA971261](https://openairdocs.org/sdr/SWIA971261.md): Pack · failed · Sep 5, 1998 · N269UE · Emb EMB120RT · Cabin Cooling System
  > RIGHT PACK FAILED AT 21,600 RESULTING IN LOSS OF CABIN PRESS DUE TO DEFERRED LEFT PACK. RETURNED TO LAS. RUN AND LEAKS CHECK OF RIGHT PACK. BLOWS STRONG, COULD NOT GET IT TO FAIL. OPS CHECKS GOOD.
- [SDR MASA98012](https://openairdocs.org/sdr/MASA98012.md): Switch · shorted · Jan 21, 1998 · N269UE · Emb EMB120RT · Instrument Panel
  > FLT 5271 - TPA-PNS - AIRCRAFT WAS ON APPROACH TO PNS WHEN THE CREW SMELLED AND SAW A SMALL AMOUNT OF SMOKE COMING FROM BEHIND THE CAPT'S INSTRUMENT PANEL. MAINTENANCE DISCOVERED THAT THE CAPT'S PUSH TO CANCEL BUTTON HAD SHORTED OUT. ITEM WAS DEFERRED PER MEL
- [SDR MASA98001](https://openairdocs.org/sdr/MASA98001.md): Bulb · failed · Jan 1, 1998 · N269UE · Emb EMB120RT · Emergency Lighting
  > FLT 5558 - JAX-GNV - CREW FOUND EXTERIOR EMERGENCY LIGHT INOP. MAINTENANCE REMOVED AND REPLACED BULB. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- [SDR MASA97066](https://openairdocs.org/sdr/MASA97066.md): Mechanism · jammed · Jul 23, 1997 · N269UE · Emb EMB120RT · Passenger/Crew Doors
  > AIRSHUTTLE 5271 - TPA-PNS - WHILE ON THE GROUND IN TPA, THE CREW FOUND THE CABIN DOOR LATCH TO BE JAMMED. MAINTENANCE LUBED THE LATCHING MECHANISM, OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- [SDR WTAA950151](https://openairdocs.org/sdr/WTAA950151.md): Control Module · failed · Apr 5, 1995 · N269UE · Emb EMB120RT · Landing Gear Retraction/Extension System
  > RDD - LANDING GEAR FAILED TO RETRACT AFTER TAKEOFF. AIRCRAFT RETURNED TO STATION WITHOUT INCIDENT. AIRCRAFT FERRIED TO FAT FOR MAINTENANCE. REPLACED LANDING GEAR CONTROL MODULE. LANDING GEAR OPERATION NORMAL DURING GEAR SWING. AIRCRAFT RETURNED TO SERVICE
- [SDR WTAA950148](https://openairdocs.org/sdr/WTAA950148.md): Prox Sensor · out of adjust · Apr 1, 1995 · N269UE · Emb EMB120RT · Landing Gear Position and Warning
  > SFO - LEFT MLG 'A' AND 'B' SYSTEM INTRANSIT LIGHTS ILLUMINATED DURING TAKEOFF ROLL. TAKEOFF ABORTED WITHOUT INCIDENT. MAINTENANCE ADJUSTED LEFT MLG 'A' AND 'B' SYSTEM DOWNLOCK PROXIMITY SENSORS. LANDING GEAR POSITION INDICATIONS NORMAL DURING GEAR SWING. AI
- [SDR WTAA950093](https://openairdocs.org/sdr/WTAA950093.md): Service Door · unsecured · Feb 20, 1995 · N269UE · Emb EMB120RT · Service Doors
  > FAT - SERVICE DOOR WARNING INDICATION RECEIVED DURING TAKEOFF ROLL. TAKEOFF ABORTED WITHOUT INCIDENT. MAINTENANCE RESECURED CAMLOCK ON FUEL SERVICE DOOR. DOOR WARNING SYSTEM OPERATIONALLY CHECKED NORMAL. AIRCRAFT RETURNED TO SERVICE. (X)
- [SDR WTAA950086](https://openairdocs.org/sdr/WTAA950086.md): Connector · dirty · Feb 15, 1995 · N269UE · Emb EMB120RT · Engine Oil Pressure
  > FAT - AFTER TAKEOFF, LEFT ENGINE OIL LOW PRESSURE AURAL WARNING ACTIVATED WITH REPORTED FLUCTUATION OF LEFT ENGINE OIL PRESSURE INDICATION OF FROM 30 PSI TO 60 PSI. AIRCRAFT RETURNED TO STATION WITHOUT INCIDENT. MAINTENANCE INSPECTED OIL PRESSURE INDICATION
- [SDR WTAA950026](https://openairdocs.org/sdr/WTAA950026.md): Door Warn · malfunction · Jan 9, 1995 · N269UE · Emb EMB120RT · Door Warning System
  > SFO - FORWARD DOOR WARNING LIGHT FAILS TO EXTINGUISH. MAINTENANCE DEFERRED DOOR WARNING SYSTEM PER MEL 52-70-1. AIRCRAFT RETURNED TO SERVICE. (Z)

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N269UE' AND deregistration_id = 'N269UE-2004-07-29'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N269UE-2004-07-29/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.