# N362NC: Boeing 737-300, registration cancelled 2026-05-14

- Type: Cancelled registration (FAA registry, deregistered aircraft)
- Cancelled: May 14, 2026
- Status when cancelled: Valid registration
- Airframe: [Boeing 737-300](https://openairdocs.org/model/boeing-737-300) (registry code 138447P)
- Data sheets: [TCDS A16WE](https://openairdocs.org/tcds/A16WE) (OpenAirDocs)
- Serial number: 25215
- Type of aircraft: Fixed wing multi engine
- Certificate issued: February 19, 2026
- Last registry action: February 19, 2026
- Mode S code: A414E9
- Owner when cancelled: [Aircraft 25215 LLC](https://openairdocs.org/faa-owner/AIRCRAFT%2025215%20LLC)
- Location: [Lake Mary, FL](https://openairdocs.org/faa-place/FL/Lake%20Mary)
- Owner type: LLC
- Owner's area on the map: 28.7714° N, 81.3530° W: Placed by OpenAirDocs at the center of ZIP code 32746, within about 3 miles (OpenAirDocs). The owner's mailing address, not where the aircraft was based
- The mark today: https://openairdocs.org/aircraft/N362NC
- FAA registry: https://registry.faa.gov/AircraftInquiry/Search/NNumberResult?nNumberTxt=362NC
- Page: https://openairdocs.org/deregistered/N362NC-2026-05-14

From the FAA registry file of November 5, 2026, cancelled registrations. Owners' street addresses are left out. The Mode S code belongs to the N-number, not the airframe.

ADs and bulletins for the Boeing 737-300: https://openairdocs.org/model/boeing-737-300.md

## Service difficulty reports (32)

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.

- [SDR NACA2022091700515](https://openairdocs.org/sdr/NACA2022091700515), Sep 17, 2022: BATTERY PACK. NO TEST. EMERGENCY EXIT LIGHTS FAILD TESTING DUE TO BATTERY PACK.
- [SDR NACA2022091600511](https://openairdocs.org/sdr/NACA2022091600511), Sep 16, 2022: BATTERY PACK. NO TEST. L1 DOOR INTERIONR AND R1 DOOR EXTERIOR EMERGENCY EXIT LIGHTS FAILED FUNCTIONAL TESTING
- [SDR NACA2022081200001](https://openairdocs.org/sdr/NACA2022081200001), Aug 12, 2022: NONE. NONE. SUPPLEMENTAL INFORMATION: REMOVED DAMAGE, PERFORMED NDT. FABBED AND INSTALLED REPAIR REF ASAP EO 53-22-037 AND B737-300 SRM AS REF IN EO. EO AND 8110-3 ON FILE.
- [SDR NACA2022080600001](https://openairdocs.org/sdr/NACA2022080600001), Aug 6, 2022: NONE. NONE. SUPPLEMENTAL INFORMATION: REMOVED DAMAGE, PERFORMED HFEC, LOCATED AND FABBED DOUBLER WITH FILLER FROM .040 2024-T3. INSTALLED REPAIR DOUBLER WET WITH SEALANT. A
- [SDR NACA2022061200002](https://openairdocs.org/sdr/NACA2022061200002), Jun 12, 2022: NONE. NONE. MAIN CABIN CENTER SEAT TRACK CRACKED STA 500B PLUS 3, FLAGGED AND MARKED AT FWD EDGE OF PALLET LOCK ASSY. SEE PWS AND PEMCO EO PD 37-53-3370 FOR DETAILS. REMOVE
- [SDR DU4R2021072920092](https://openairdocs.org/sdr/DU4R2021072920092), Jul 29, 2021: SUPPORT FITTING. CRACKED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND LEFT WING AT MLG SYPPORT FITTING, HOLE #5 HAS A CRACK INDICATION IN CHORD LAYER. S/O 660006 N/R 38
- [SDR DU4R2021072200091](https://openairdocs.org/sdr/DU4R2021072200091), Jul 22, 2021: BULB. BURNED OUT. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND NUMBEROUS BULBS WERE OUT IN THE EMERGENCY EXIT LIGHTS ABOVE AND BELOW THE ENTRY DOORS. S/O 660006 
- [SDR DU4R2021071900090](https://openairdocs.org/sdr/DU4R2021071900090), Jul 19, 2021: SKIN. CRACKED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L1 DOOR AT UPPER HINGE, HOLE AT BS 303.9, STR. 10L HAS TWO CRACK INDICATIONS. S/O 660006 N/R 39632
- [SDR DU4R2021071900089](https://openairdocs.org/sdr/DU4R2021071900089), Jul 19, 2021: SKIN. CRACKED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L1 DOOR FWD CORNER HAS CRACK INDICATION IN HOLE BS 304 - 6.5 INCHES, 2 INCHES DOWN FROM STR. 6L. S
- [SDR DU4R2021070800087](https://openairdocs.org/sdr/DU4R2021070800087), Jul 8, 2021: SKIN. CRACKED. DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND L/H WING, I/B UPPER SKIN, HOLE "B" 68, HAS A CRACK INDICATION. S/O 660006 N/R 38768
- [SDR DU4R2021070800086](https://openairdocs.org/sdr/DU4R2021070800086), Jul 8, 2021: SKIN. CRACKED. DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND L/H WING, I/B UPPER SKIN, HOLE "A" 100, HAS A CRACK INDICATION. S/O 660006 N/R 38767
- [SDR DU4R2021070800085](https://openairdocs.org/sdr/DU4R2021070800085), Jul 8, 2021: SKIN. CRACKED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L/H WING, I/B UPPER SKIN, HOLE "A" 75, AS A CRACK INDICATION. S/O 660006 N/R 38766
- [SDR DU4R070800084](https://openairdocs.org/sdr/DU4R070800084), Jul 8, 2021: SKIN. CORRODED. DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND LEFT WING UPPER SKIN ON THE LOWER SURFACE AT WBL 174.7, THE SKIN HAS CORROSION 1" FWD OF T/E OF S
- [SDR DU4R2021070600083](https://openairdocs.org/sdr/DU4R2021070600083), Jul 6, 2021: SUPPORT. CRACKED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND RIGHT WING AFT 3678R WTB PANEL SUPPORT IS CHAFED AND CRACKED AT STA. 727 STR. 19 - 20R. S/O 660006
- [SDR DU4R2021070600082](https://openairdocs.org/sdr/DU4R2021070600082), Jul 6, 2021: SUPPORT FITTING. CRACKED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND MLG SUPPORT FITTING OF RIGHT WING AT HAS CRACK INDICATION IN HOLE #11 AND #12 IN REAR SPAR WEB LAY
- [SDR DU4R2021070200081](https://openairdocs.org/sdr/DU4R2021070200081), Jul 2, 2021: SUPPORT. CRACKED. DURING SCHEDULED INSPECTION, FOUND R/H MAIN LANDING W/W AFT BELLY CUTOUT RADIUS PANEL HAD A CRACKED PANEL SUPPORT. S/O 660006 N/R 38470
- [SDR DU4R2021062400080](https://openairdocs.org/sdr/DU4R2021062400080), Jun 24, 2021: FITTING. CORRODED. DURING SCHEDULED INSPECTION, FOUND LEFT MAIN LANDING GEAR FORWARD OUTBOARD LUG HAS SEVERE PITTING CORROSION. S/O 660006 N/R 38671
- [SDR DU4R2021062300079](https://openairdocs.org/sdr/DU4R2021062300079), Jun 23, 2021: ANGLE. CRACKED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L/H WING #3 FLAP FAIRING HAS TWO CRACKED INTERNAL "L" ANGLES. S/O 660006 N/R 38745
- [SDR DU4R202106230078](https://openairdocs.org/sdr/DU4R202106230078), Jun 23, 2021: PANEL. CORRODED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND R/H WING T/E AILERON, #3 AILERON HINGE FITTING, PANEL ATTACH BOLT HOLES HAVE CORROSION IN AND AROU
- [SDR DU4R2021060900077](https://openairdocs.org/sdr/DU4R2021060900077), Jun 9, 2021: ANGLE. DENTED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND DENT IN FWD LWR ANGLE OF MAIN CARGO DOOR CUTOUT DOOR JAMB. S/O 660006 N/R 38238
- [SDR DU4R2021060400076](https://openairdocs.org/sdr/DU4R2021060400076), Jun 4, 2021: BRACKET. PUNCTURED. DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND WEB BRACKET HAS A PUNCTURE AT BS 344, STR. 16L. S/O 660006 N/R 38669
- [SDR DU4R2021060400075](https://openairdocs.org/sdr/DU4R2021060400075), Jun 4, 2021: HINGE FITTING. CORRODED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND R/H WING T/E AILERON, #2 AILERON HINGE FITTING, PANEL ATTACH BOLT HOLES, HAVE CORROSION IN AND ARO
- [SDR DU4R2021051700074](https://openairdocs.org/sdr/DU4R2021051700074), May 17, 2021: FLOOR PANEL. CORRODED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND AFT CARGO COMPARTMENT FLOOR PANEL 1534X HAS MULTIPLE AREAS OF SURFACE ETCH CORROSION. S/O 660006 N
- [SDR DU4R2021051400072](https://openairdocs.org/sdr/DU4R2021051400072), May 14, 2021: STRUCTURE. DAMAGED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND A DENT AND CRACK IN THE L/H TRAILING EDGE OF THE MID FLAP THAT WAS STOP DRILLED AND SEALED. S/O 66
- [SDR DU4R2021050700071](https://openairdocs.org/sdr/DU4R2021050700071), May 7, 2021: SHEAR WEB. CRACKED. DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND SHEAR WEB FRAME 592.4 OF FWD CARGO DOOR AFT FRAME IS CRACKED. S/O 660006 N/R 38630
- [SDR DU4R2021050700070](https://openairdocs.org/sdr/DU4R2021050700070), May 7, 2021: TRANSITION PANEL. CORRODED. DURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND AFT CARGO COMPARTMENT, BS 727D +10 - 790 LBL 24 TRANSITION PANEL HAS MULTIPLE AREAS OF CORROSION 
- [SDR DU4R2021050400069](https://openairdocs.org/sdr/DU4R2021050400069), May 4, 2021: ATTACH ANGLE. CORRODED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND MULTIPLE AREAS OF CORROSION ON FLOOR PANEL CROSS ATTACH ANGLE IN AFT CARGO COMPARTMENT AT BS947.5,
- [SDR DU4R2021050300068](https://openairdocs.org/sdr/DU4R2021050300068), May 3, 2021: ATTACH FITTING. CORRODED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND R/H MLG SUPPORT BEAM STABILIZER ATTACH FITTING HAS FRETTING ON BOTH LUG FACES. S/O 660006 N/R 3946
- [SDR DU4R2021050300067](https://openairdocs.org/sdr/DU4R2021050300067), May 3, 2021: TRANSITION PANEL. CORRODED. DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND TRANSITION PANEL IN AFT CARGO COMPARTMENT, AT BS 787 TO BS 947.5, LBL 24, HAS MULTIPLE AREAS OF CO
- [SDR NACA2020120900020](https://openairdocs.org/sdr/NACA2020120900020), Dec 9, 2020: FLAP SYSTEM. MALFUNCTIONED. DISCREPANCY: MISSED APPROACH DUE TO FLAPS NOT DEPLOYING AND SPEED BRAKE NOT DEPLOYING. NO FLAP ASSYMETRY AND NO FLAP DISAGREE. CORRECTIVE ACTION: PERFORMED FLAP
- [SDR NACA2020112700019](https://openairdocs.org/sdr/NACA2020112700019), Nov 24, 2020: SKIN. CRACKED. DISCREPANCY: CRACK ON LEFT SIDE FUSELAGE, 14 INCHES FWD OF BS 500, 2.75 INCHES ABOVE S26L, 1.5 INCHES LONG. CUT OUT DAMAGE, FABBED DOUBLER AND INSTALLED, PER RE
- [SDR NACA2020110600018](https://openairdocs.org/sdr/NACA2020110600018), Nov 5, 2020: START VALVE. INOPERATIVE. DISCREPANCY: DURING CLIMB NR 2 ENGINE EGT LIGHT ILLUMINATED A/T DISCONNECT MANUAL THRUST REDUCTION. LARGE THRUST LEVER SPLIT FOR EQUAL THRUST. A/P & AT ILS ENGI

---