# Service difficulty reports: N406NV, cancelled May 29, 2020

A list on [N406NV, cancelled May 29, 2020](https://openairdocs.org/deregistered/N406NV-2020-05-29.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR JR2R20161004491](https://openairdocs.org/sdr/JR2R20161004491.md): Pan · cracked · Oct 4, 2016 · N406NV · Doug MD83 · Fuselage Miscellaneous Structure
  > L1 DOOR PAN CRACKED AT THE FWD UPPER CORNER. REPAIRED L1 DOOR PAN IAW EA 40-2016-314.
- [SDR JR2R20160930393](https://openairdocs.org/sdr/JR2R20160930393.md): Scoop · cracked · Sep 30, 2016 · N406NV · Doug MD83 · Vertical Stabilizer, Plate/Skin
  > VERTICAL STABILIZER RAM AIR SCOOP CRACKED. REPAIRED VERTICAL STABILIZER RAM AIR SCOOP IAW EA 40-2016-308.
- [SDR WX0A201607193177](https://openairdocs.org/sdr/WX0A201607193177.md): Control Valve · cracked · Jul 14, 2016 · N406NV · Doug DC983 · Pneumatic Indicating System
  > DURING CLIMB OUT, PASSING 9000 FT, TAIL COMPARTMENT HIGH LIGHT AND MASTER WARNING RED LIGHTS ILLUMINATED. PRFORMED MEMORY ITEMS PER QRH 21.4 PERFORMED QRH 21.4 AND LIGHT EXTINGUISHED WITH RIGHT THROTTLE RETARTED. FOLLOWED 21.4 7A-B EMERGENCY DECLARED, RETUR
- [SDR WX0A2015121573044](https://openairdocs.org/sdr/WX0A2015121573044.md): Unknown · smoke · Dec 14, 2015 · N406NV · Doug DC983 · Air Distribution System
  > SMOKE IN CABIN WITH APU ON. COMPLIED WITH TC 21-059-002.
- [SDR WX0A2015092472886](https://openairdocs.org/sdr/WX0A2015092472886.md): Smoke Detector · false activation · Sep 22, 2015 · N406NV · Doug DC983 · Smoke Detection
  > AFT LT LAVATORY SMOKE DETECTOR CHIMING. R & R AFT LT LAVATORY SMOKE DETECTOR IAW CMM 26-10-02. OPERATIONS CHECKED GOOD. THIS CLEAR MEL 26-07 SIT 1 CAT C DMI 19912. PLACARDS REMOVED & SYS RESTORED TO ORIGINAL CONFIGURATION.
- [SDR WX0A2015081172786](https://openairdocs.org/sdr/WX0A2015081172786.md): Bolt · loose · Aug 8, 2015 · N406NV · Doug DC983 · Engine Oil Distribution (Airframe Furnished)
  > OIL QTY DECREASED FROM 9 QTS TO 5 QTS DURING CLIMB. PERFORMED EQRH 72.15. OIL STABILIZED AT 5 QTS LANDED WITH 4 QTS. FOUND LOOSE BOLTS IAW ON NR 4 BEARING OIL BREATHER TUBE ATTACH POINT UPSTREAM. SECURED BOLTS IAW AMM 79-20-02-2-0 10 B. LEAK CHECKED GOOD
- [SDR WX0A2015062672700](https://openairdocs.org/sdr/WX0A2015062672700.md): Clamp · out of position · Jun 25, 2015 · N406NV · Doug DC983 · Cabin Cooling System
  > TAIL COMPARTMENT TEMP HIGH AT 3200 MSL. COMPLIED WITH QRH 21.4. LIGHT WENT OUT 1:10 AFTER STEP 3 BUT BEFORE CONTINUING TO STEP 4. APU WAS RUNNING WITH AIR OFF. REF WO 00260195 -1 & -2 TC 21-059-010 & TC 21-059-005. FOUND LT HEAT EXCHANGER CLAMP OFF. SECU
- [SDR WX0A2015062672694](https://openairdocs.org/sdr/WX0A2015062672694.md): Power Supply · damaged · Jun 25, 2015 · N406NV · Doug DC983 · Emergency Lighting
  > FOUND ON WAKE UP, EMER LIGHTS INOPERATIVE AT ROWS 22 - 25. REPLACED BATTERIES. REPLACED POWER SUPPLY DUE TO DAMAGE. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.
- [SDR WX0A2015062672693](https://openairdocs.org/sdr/WX0A2015062672693.md): Battery · discharged · Jun 25, 2015 · N406NV · Doug DC983 · Emergency Lighting
  > FOUND ON WAKE UP, EMER LIGHTS INOPERATIVE AT ROWS 17 - 19. REPLACED BATTERIES. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.
- [SDR WX0A2015051172584](https://openairdocs.org/sdr/WX0A2015051172584.md): Battery Pack · discharged · May 10, 2015 · N406NV · Doug DC983 · Emergency Lighting
  > EMERGENCY OVERHEAD LIGHTS INOPERATIVE AT SEATS 16, 18L & 20. REPLACED CABIN EMER LIGHT BATTERY PACK AS REQUIRED IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A072350](https://openairdocs.org/sdr/WX0A072350.md): Portable Light · inoperative · Jan 11, 2015 · N406NV · Doug DC983 · Emergency Lighting
  > PORTABLE LIGHT EMER AT L1 DOOR IS INOPERATIVE. R & R PORTABLE EMER LIGHT IAW AMM 33-533-00-5 CONFIG 1. LIGHT CHECK IS GOOD.
- [SDR WX0A2014090972146](https://openairdocs.org/sdr/WX0A2014090972146.md): Wire · broken · Sep 6, 2014 · N406NV · Doug MD83 · Light System Wiring
  > LEFT AFT STAIRWAY EMER LIGHT INOPERATIVE. REPLACED BROKEN WIRE TO LIGHT. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.
- [SDR WX0A2014081172088](https://openairdocs.org/sdr/WX0A2014081172088.md): Slide · unserviceable · Aug 10, 2014 · N406NV · Doug MD83 · Escape Slide
  > L2 SLIDE INDICATOR IN THE RED. R & R L2 DOOR SLIDE IAW AMM 25-62-00 & TC R0902502.
- [SDR WX0A2014070772009](https://openairdocs.org/sdr/WX0A2014070772009.md): Finger Doubler · corroded · Jul 3, 2014 · N406NV · Doug MD83 · Fuselage Main, Plate/Skin
  > FUSELAGE FINDER DOUBLER CORRODED OUT OF LIMITS STATION 231 - 235 ABOVE LONGERON 26L. CUT OUT DAMAGED AREA, FABRICATED FINGER DOUBLER, INTERNAL DOUBLERS, REPAIR PARTS. LOCATED DRILLED & INSTALLED FLUSH DOUBLER REPAIR IAW SRM 53-04 FIG 12C.
- [SDR WX0A071984](https://openairdocs.org/sdr/WX0A071984.md): Light · inoperative · Jun 4, 2014 · N406NV · Doug MD83 · Emergency Lighting
  > AFT STAIRS EMER LIGHTS INOPERATIVE. R & R AFT AIR STAIRS EMER LIGHTS 2 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A071960](https://openairdocs.org/sdr/WX0A071960.md): Battery · discharged · May 22, 2014 · N406NV · Doug MD83 · Emergency Lighting
  > MAIN CABIN EMER LIGHTS INOPERATIVE. REPLACED BATTERIES FOR EFFECTED LIGHTS IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A071979](https://openairdocs.org/sdr/WX0A071979.md): Switch · intermittent · May 1, 2014 · N406NV · Doug MD83 · Cabin Cooling System
  > AFTER TAKEOFF WE NOTICED PRESSURIZATION WAS NOT OPERATING NORMALLY. THE FLIGHT ATTENDANT INFORMED US THAT THE CABIN WAS GETTING HAZY & THE AFT RT SMOKE ALARM HAD ILLUMINATED. TURNED OFF THE PACK & THIS SEEMED TO CORRECT THE PROBLEMS. PERFORMED ENG RUNS, OPE
- [SDR WX0A071934](https://openairdocs.org/sdr/WX0A071934.md): Power Supply · inoperative · Apr 28, 2014 · N406NV · Doug MD83 · Emergency Lighting
  > FORWARD EMERGENCY LAMPS INOPERATIVE IN COCKPIT & ENTRY WAY CEILING. R & R FWD ENTRY WAY BATTERY POWER SUPPLY ASSEMBLY IAW AMM 33-53-00 & 33-53-01, OPERATIONS CHECKED GOOD.
- [SDR WX0A071930](https://openairdocs.org/sdr/WX0A071930.md): Battery · discharged · Apr 27, 2014 · N406NV · Doug MD83 · Emergency Lighting
  > NUMEROUS CABIN EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES IAW MM 33-51-00, OPERATIONS CHECKED GOOD.
- [SDR WX0A071929](https://openairdocs.org/sdr/WX0A071929.md): Battery · discharged · Apr 27, 2014 · N406NV · Doug MD83 · Emergency Lighting
  > FLIGHT DECK EMERGENCY LIGHTS INOPERATIVE. INSTALLED NEW BATTERIES FOR FLIGHT DECK EMERGENCY LIGHTS IAW MM 33-51-00, OPERATIONS CHECKED GOOD.
- [SDR WX0A071928](https://openairdocs.org/sdr/WX0A071928.md): Battery · discharged · Apr 27, 2014 · N406NV · Doug MD83 · Emergency Lighting
  > EMERGENCY STBY LIGHT IN FWD CABIN INOPERATIVE. INSTALLED NEW BATTERIES FOR FWD CABIN EMERGENCY LIGHT IAW MM 33-51-00, OPERATIONS CHECKED GOOD.
- [SDR WX0A071915](https://openairdocs.org/sdr/WX0A071915.md): Power Supply · inoperative · Apr 20, 2014 · N406NV · Doug MD83 · Emergency Lighting
  > EMERGENCY LIGHTS ON FLIGHT DECK WILL NOT ILLUMINATE DURING CHECK. R & R POWER SUPPLY IAW AMM 33-53-00, OPERATIONS GOOD.
- [SDR WX0A20131004716](https://openairdocs.org/sdr/WX0A20131004716.md): Battery · inoperative · Oct 2, 2013 · N406NV · Doug DC983 · Emergency Equipment
  > AFT F/A FLASHLIGHT RED LIGHT DOES NOT BLINK. R & R FLASHLIGHT BATTERY IAW AMM 25-60-00, OPS CHECKED GOOD.
- [SDR WX0A2013091071688](https://openairdocs.org/sdr/WX0A2013091071688.md): Seat Track · corroded · Sep 4, 2013 · N406NV · Doug DC983 · Fuselage, Seat/Cargo Attach Fittings
  > SEAT TRACK HAS CORROSION AT LBL 44 BETWEEN FS 1136 AND 1139. REPAIRED SEAT TRACK IAW SRM 53-05.
- [SDR WX0A201309107187](https://openairdocs.org/sdr/WX0A201309107187.md): Pan · corroded · Sep 4, 2013 · N406NV · Doug DC983 · Fuselage Miscellaneous Structure
  > FLOOR PAN CORRODED BETWEEN BS 148.55 AND 160.00. REPAIRED AREA IAW SRM 53-01.
- [SDR WX0A2013091071686](https://openairdocs.org/sdr/WX0A2013091071686.md): Seat Track · chafed · Sep 1, 2013 · N406NV · Doug DC983 · Fuselage, Seat/Cargo Attach Fittings
  > CABIN RT SEAT TRACK CHAFED OUT OF LIMITS, BS 1155, RBL 22. CUTOUT DAMAGED AREA, LOCATED, DRILLED, AND INSTALLED REPAIRS IAW SRM 53-05, FIG 4A.
- [SDR WX0A2013083071675](https://openairdocs.org/sdr/WX0A2013083071675.md): Tab · damaged · Aug 27, 2013 · N406NV · Doug DC983 · Rudder, Tab Structure
  > RIGHT ELEVATOR CONTROL TAB T/E DAMAGED AT STATION XHS 69; APPROX 3 FT FROM OTBD END. REMOVED DAMAGED SKIN, FABRICATED DOUBLER AND ACCOMPLISHED HOT BOND REPAIR IAW SRM 55-04, PARA 3, PAGE 9. DOUBLER MEASURES 4".
- [SDR WX0A071258](https://openairdocs.org/sdr/WX0A071258.md): Battery Pack · discharged · Aug 1, 2012 · N406NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A070994](https://openairdocs.org/sdr/WX0A070994.md): Battery Pack · discharged · Nov 7, 2011 · N406NV · Doug MD83 · Emergency Lighting
  > IT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERAT
- [SDR WX0A070966](https://openairdocs.org/sdr/WX0A070966.md): Light · inoperative · Oct 20, 2011 · N406NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE A
- [SDR WX0A070965](https://openairdocs.org/sdr/WX0A070965.md): Battery · discharged · Oct 14, 2011 · N406NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070883](https://openairdocs.org/sdr/WX0A070883.md): Light · inoperative · Jun 16, 2011 · N406NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE A
- [SDR WX0A070589](https://openairdocs.org/sdr/WX0A070589.md): Pan · corroded · Aug 21, 2010 · N406NV · Doug DC982 · Fuselage Miscellaneous Structure
  > FORWARD CARGO DOOR CUTOUT PAN IS CORRODED AROUND RIV-NUT INSERTS. REPAIRED DOOR PAN IAW MD80 SRM 53-01 FIG 1, 53-14-2 PG 2, 51-30-01 & 53-05 FIG 44.
- [SDR WX0A070508](https://openairdocs.org/sdr/WX0A070508.md): Battery Pack · no test · Jan 6, 2010 · N406NV · Doug DC982 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070276](https://openairdocs.org/sdr/WX0A070276.md): Battery Pack · inoperative · Feb 25, 2009 · N406NV · Doug DC982 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N406NV' AND deregistration_id = 'N406NV-2020-05-29'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N406NV-2020-05-29/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.