- [SDR WX0A2018111273372](https://openairdocs.org/sdr/WX0A2018111273372.md): Sensor · faulted · Nov 8, 2018 · N423NV · Doug DC983 · Drag Control System
  > SPOILER DEPLOYED ANNUNCIATOR ILLIMINATED AND STAYED ON DURING DESCENT. EMERGENCY DECLARED. R & R THE LT INBD FLIGHT SPOILER DEPLOYED SENSOR.
- [SDR JR2R20170831362](https://openairdocs.org/sdr/JR2R20170831362.md): Skin · gouged · Aug 31, 2017 · N423NV · Doug MD83 · Trailing Edge Flaps
  > RIGHT WING OTBD FLAP LEADING EDGE, GOUGED IN SKIN AND DOUBLER. REPAIRED THE FLAP LEADING EDGE IAW EA 45-2017-102.
- [SDR JR2R20170827356](https://openairdocs.org/sdr/JR2R20170827356.md): Frame · cracked · Aug 27, 2017 · N423NV · Doug MD83 · Fuselage Main, Frame
  > DAR FINDING, RADOME, LOWER RIGHT GUIDE PIN FASTNER AND FRAME CRACKED.
- [SDR JR2R20170826108](https://openairdocs.org/sdr/JR2R20170826108.md): Beam · corroded · Aug 26, 2017 · N423NV · Doug MD83 · Fuselage Main, Structure
  > AFT CARGO DOOR OPENING, LOWER BEAM HAS CORROSION BETWEEN FS 1155 TO 1212.
- [SDR WX0A2017070373270](https://openairdocs.org/sdr/WX0A2017070373270.md): Blower · odor · Jul 1, 2017 · N423NV · Doug DC983 · Air Distribution Fan
  > VENT BLOWER HAS DISTINCT OIL AND EXHAUST SMELL. COULD NOT DUPLICATE SMELL.
- [SDR WX0A2015121100039](https://openairdocs.org/sdr/WX0A2015121100039.md): Lamp · inoperative · Dec 8, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > EMERGENCY OVERHEAD LIGHT AT ROW 5 INOPERATIVE. RELAMPED OVERHEAD EMERGENCY LIGHT AT ROW 5. OPS CHECK GOOD IAW AMM 33-53-00.
- [SDR WX0A2015101572944](https://openairdocs.org/sdr/WX0A2015101572944.md): Battery Pack · discharged · Oct 12, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > EMERGENCY STANDBY LIGHTS INOPERATIVE AT ROW 21, 23 & 24. R & R BATTERY PACK AT ROW 23R IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2015092872907](https://openairdocs.org/sdr/WX0A2015092872907.md): Battery · discharged · Sep 27, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > EMERGENCY & STANDBY LIGHTS INOPERATIVE ROWS 20 - 24. R & R BATTERIES AT POWER PACK LOCATIONS FOR ROWS 20 - 24 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD AT THIS TIME.
- [SDR WX0A2015092872896](https://openairdocs.org/sdr/WX0A2015092872896.md): Engine · making metal · Sep 19, 2015 · N423NV · Doug DC983 · Engine (Turbine/Turboprop)
  > RIGHT OIL STRAINER CLOGGING ANNUNCIATORS ILLUMINATED IN FLIGHT. FOLLOWED QRH 72.16, DIVERTED IAW QRH INSTRUCTION. FOUND METAL IN THE OIL, REPLACED NR 2 ENG IAW TC 71-080-003. REF LOG PAGE 576743.
- [SDR WX0A2015092472884](https://openairdocs.org/sdr/WX0A2015092472884.md): Engine · malfunctioned · Sep 19, 2015 · N423NV · Doug DC983 · Engine (Turbine/Turboprop)
  > DURING CLIMB OUT IN CALM CLEAR AIR, FELT A HEAVY VIBRATION THROUGHOUT THE ENTIRE ACFT, IT ONLY LASTED A FEW SECONDS. R & R NR 2 ENG IAW TC 71-080-003. ACFT OK FOR SERVICE.
- [SDR WX0A2015072700058](https://openairdocs.org/sdr/WX0A2015072700058.md): Battery Pack · inoperative · Jul 25, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > VENTRAL STAIRS CEILING EMERGENCY LIGHTS INOPERATIVE. R & R BATTERIES IN EMERGENCY LIGHTS BATTERY PACK B5-28 IAW AMM 33-53-00 & WDM 33-51-13. OPERATIONS CHECKED GOOD.
- [SDR WX0A2015072700057](https://openairdocs.org/sdr/WX0A2015072700057.md): Battery Pack · inoperative · Jul 24, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > FOUND 6 CONSECUTIVE EMERGENCY CEILING LIGHTS INOPERATIVE. REPLACED 2 EACH EMERGENCY BATTERIES IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2015061572659](https://openairdocs.org/sdr/WX0A2015061572659.md): Gasket · blown · Jun 13, 2015 · N423NV · Doug DC983 · APU Engine Fuel and Control
  > UPON OPENING THE L1 DOOR ARRIVAL, THE TWO FWD FLIGHT ATTENDANTS, MYSELF & THE FIRST OFFICER SMELLED A FAINT FUEL SMELL, WHICH WE ASSUMED CAME FROM OUTSIDE. LATER DETERMINED THE SMELL WAS COMING FROM OUR VENTS VIA APU AIR. IMMEDIATELY SHUT THE APU AIR OFF & P
- [SDR WX0A2015052772606](https://openairdocs.org/sdr/WX0A2015052772606.md): Battery · discharged · May 21, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > FOUND ON WAKE UP, ROWS 21 - 24 EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES AT ROW 23 FWD SET. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.
- [SDR WX0A2015052072603](https://openairdocs.org/sdr/WX0A2015052072603.md): Light · inoperative · May 19, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > AFT TAIL COMPARTMENT, TWO EMER EXIT LIGHTS INOPERATIVE. RELAMPED TWO EMER EXIT LIGHTS IN AFT TAIL COMPARTMENT IAW AMM 33-53-00. OPERATIONS CHECKED NORMAL.
- [SDR WX0A2015031972472](https://openairdocs.org/sdr/WX0A2015031972472.md): Battery · discharged · Mar 17, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > TAIL CONE CEILING EMER EXIT LIGHTS INOPERATIVE. REPLACED BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.
- [SDR WX0A072471](https://openairdocs.org/sdr/WX0A072471.md): Battery · discharged · Mar 17, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > INTERIOR FWD OVERWING EMER EXIT LIGHTS VERY DIM. REPLACED BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.
- [SDR WX0A2015012672377](https://openairdocs.org/sdr/WX0A2015012672377.md): Battery · discharged · Jan 21, 2015 · N423NV · Doug DC983 · Emergency Lighting
  > ROW 23 EMER LIGHTS INOPERATIVE. REPLACED BATTERIES AT 24DEF. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.
- [SDR WX0A2015012672370](https://openairdocs.org/sdr/WX0A2015012672370.md): Ballast · faulty · Jan 19, 2015 · N423NV · Doug DC983 · Passenger Compartment Lighting
  > AIRCRAFT OUT OF SERVICE UNTIL 01/25. SHORTLY AFTER TAKEOFF BOTH LAVATORY SMOKE ALARMS WENT OFF. FLIGHT ATTENDANTS REPORTED BURNING SMELL. COMPLIED WITH QRH 26.9 & RETURNED TO FIELD. MULTIPLE CBS PULLED IAW CHECKLIST. COMPLIED WITH WO 00244014 & 00244013.
- [SDR WX0A2014081172084](https://openairdocs.org/sdr/WX0A2014081172084.md): Battery · discharged · Aug 10, 2014 · N423NV · Doug MD83 · Emergency Lighting
  > DURING EMER LIGHTS TEST, THE COCKPIT EMER LIGHTS WILL NOT REMAIN ILLUMINATED. R & R BATTERIES FOR COCKPIT EMER LIGHTS. OPERATIONS CHECKED GOOD IAW MM 33-55-00.
- [SDR WX0A071995](https://openairdocs.org/sdr/WX0A071995.md): Fuel · leaking · Jun 18, 2014 · N423NV · Doug MD83 · APU Engine Fuel and Control
  > SMOKE IN THE CABIN DUE TO APU FUEL LEAK. INFO NOT AVAILABLE, WILL INCLUDE WHEN AVAILABLE.
- [SDR WX0A071765](https://openairdocs.org/sdr/WX0A071765.md): Compressor · stalled · Dec 2, 2013 · N423NV · Doug MD83 · Turbine Engine Compressor Section
  > ON TAXI OUT WE RECEIVED 5 COMPRESSOR STALLS. UNABLE TO DETERMINE WHICH ENG. CHECKED RIG & TRIM OF LT ENG IAW MD80-MM-71-00-00 CONFIG 1. DRAINED MOISTURE TRAP, CHECKED PRESSURIZATION & DUMP VLV IAW MD80-73-20-00, ACCOMPLISHED M739, OPERATIONS CHECKED NORMAL,
- [SDR WX0A2013040171547](https://openairdocs.org/sdr/WX0A2013040171547.md): Battery Pack · discharged · Mar 29, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A2013040171548](https://openairdocs.org/sdr/WX0A2013040171548.md): Battery · discharged · Mar 28, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071507](https://openairdocs.org/sdr/WX0A071507.md): Battery · discharged · Jan 18, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071506](https://openairdocs.org/sdr/WX0A071506.md): Battery · discharged · Jan 18, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071505](https://openairdocs.org/sdr/WX0A071505.md): Battery · discharged · Jan 18, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071484](https://openairdocs.org/sdr/WX0A071484.md): Battery · discharged · Jan 18, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071483](https://openairdocs.org/sdr/WX0A071483.md): Battery · discharged · Jan 18, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071482](https://openairdocs.org/sdr/WX0A071482.md): Battery · discharged · Jan 18, 2013 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071462](https://openairdocs.org/sdr/WX0A071462.md): Battery · discharged · Dec 30, 2012 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071451](https://openairdocs.org/sdr/WX0A071451.md): Battery · discharged · Dec 12, 2012 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071450](https://openairdocs.org/sdr/WX0A071450.md): Battery · discharged · Dec 12, 2012 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071347](https://openairdocs.org/sdr/WX0A071347.md): Battery · discharged · Oct 5, 2012 · N423NV · Doug MD83 · Emergency Lighting
  > IT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS A
- [SDR WX0A071330](https://openairdocs.org/sdr/WX0A071330.md): Battery · discharged · Sep 23, 2012 · N423NV · Doug MD83 · Emergency Lighting
  > IT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERAT
- [SDR WX0A071283](https://openairdocs.org/sdr/WX0A071283.md): Coalescer Bag · dirty · Aug 19, 2012 · N423NV · Doug MD83 · Humidity Control System
  > DURING INITIAL CLIMBOUT SUDDENLY GOT A VERY STRONG BURNING ODOR. PAX WERE COMPLAINING ABOUT EYE IRRITATION. NO VISIBLE SMOKE SIGNS. INITIATED AIR RETURN. INSTALLED NEW END UNION PACKING ON AUX PUMP LEAK, CHECK OK MM 29-01-05. REMOVED AND REPLACED COALESCE
- [SDR WX0A071154](https://openairdocs.org/sdr/WX0A071154.md): Battery Pack · discharged · Apr 5, 2012 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A0711545/2012](https://openairdocs.org/sdr/WX0A0711545%2F2012.md): Battery Pack · discharged · Apr 5, 2012 · N423NV · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N423NV' AND deregistration_id = 'N423NV-2025-05-27'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N423NV-2025-05-27/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.