- [SDR MALA060492](https://openairdocs.org/sdr/MALA060492.md): Oil System · unknown · Jul 30, 2006 · N534XJ · Bac AVRO146RJ85A · Turbine Engine Oil System
  > AFTER TAKEOFF, NR 4 ENGINE OIL PRESSURE DROPPED TO RED ZONE. CREW SHUT ENGINE DOWN. ENGINE VIB CYCLED BETWEEN 1.1 & 1.9. ROUGHLY 1 MINUTE AFTER TAKEOFF NR 4 OIL PRESSURE ILLUMINATED. NR 4 OIL PSI WAS IN THE RED. NO VIBRATION WAS FELT ON THE AIRCRAFT. NR 4
- [SDR MALA060481](https://openairdocs.org/sdr/MALA060481.md): Slide · damaged · Jul 19, 2006 · N534XJ · Bac AVRO146RJ85A · Escape Slide
  > PAX DOOR 2 RIGHT GIRT BAR END CAPS NOT YELLOW IN COLOR (WERE WHITE). REPLACED SLIDE ASSEMBLY
- [SDR MALA060139](https://openairdocs.org/sdr/MALA060139.md): Battery Pack · no test · Mar 7, 2006 · N534XJ · Bac AVRO146RJ85A · Emergency Lighting
  > FAILED CAP CHECK PER CMM 33-50-38. REPLACED BATTERY PACK.
- [SDR MALA050664](https://openairdocs.org/sdr/MALA050664.md): Battery · failed · Aug 17, 2005 · N534XJ · Bac AVRO146RJ85A · Battery/Charger System
  > FAILED CAP CHECK.
- [SDR MALA050180](https://openairdocs.org/sdr/MALA050180.md): Battery Pack · inoperative · Jan 25, 2005 · N534XJ · Bac AVRO146RJ85A · Emergency Lighting
  > BATTERY PACK P/N 61-2275-1, S/N 0006355 REMOVED FOR SCHEDULED CAPACITY CHECK. CAPACITY CHECK FAIL. REPLACED BATTERY ASSEMBLY P/N 61-2274-1. UNIT PASSES CMM CHECKS, RTS 1/27/05.
- [SDR MALA040912](https://openairdocs.org/sdr/MALA040912.md): Uplock · frozen · Dec 22, 2004 · N534XJ · Bac AVRO146RJ85A · Landing Gear Position and Warning
  > DURING FLIGHT, LT GEAR NOT INDICATING UP AND LOCKED. RED LIGHT ILLUMINATED AND GEAR HANDLE LIGHT ILLUMINATED. AIR RETURN TO MSP. MAINTENANCE FOUND ICE COMPLETELY AROUND DOOR UPLOCK LATCH AND SURROUND DOOR WAS UNABLE TO LATCH CLOSED. REMOVED ICE, NO DAMAGE
- [SDR MALA040650](https://openairdocs.org/sdr/MALA040650.md): Tube · contaminated · Oct 28, 2004 · N534XJ · Bac AVRO146RJ85A · Extinguishing System
  > DURING NR 1 CARGO FIRE EXTINGUISHER CHANGE FOUND FLEX TUBE P/N AE711192, UNION P/N AN832 SOLID LINE P/N AE40114-4 FILLED WITH UNKNOWN SUBSTANCE. MAINTENANCE REMOVED AND REPLACED RIGID AND FLEXIBLE LINE IAW AMM CH 26, ALL CHECKS GOOD.
- [SDR MALA040557](https://openairdocs.org/sdr/MALA040557.md): Battery Pack · failed · Aug 11, 2004 · N534XJ · Bac AVRO146RJ85A · Emergency Lighting
  > DURING SCHEDULED CAPACITY CHECK, BATTERY PACK PN/61-2275-1 SN/9810762 FAILED. MAINTENANCE REPLACED BATTERY ASSEMBLY PN 61-2274-1. UNIT PASSES CMM CHECKS. RETURNED TO SERVICE 8/17/04. REFER TO WO NR 373901 FOR ADDITIONAL INFORMATION.
- [SDR MALA040558](https://openairdocs.org/sdr/MALA040558.md): Battery Pack · discharged · Aug 7, 2004 · N534XJ · Bac AVRO146RJ85A · Emergency Lighting
  > DURING SCHEDULED CAPACITY CHECK, BATTERY PACK PN/61-2275-1 SN/9805520 FAILED. MAINTENANCE REPLACED BATTERY ASSEMBLY PN 61-2274-1. UNIT PASSES CMM CHECKS. RETURNED TO SERVICE 8/17/04. REFER TO WO NR 373758 FOR ADDITIONAL INFORMATION.
- [SDR MALA040559](https://openairdocs.org/sdr/MALA040559.md): Battery Pack · failed · Aug 7, 2004 · N534XJ · Bac AVRO146RJ85A · Emergency Lighting
  > DURING SCHEDULED CAPACITY CHECK, BATTERY PACK PN/61-2275-1 SN/9801233 FAILED ON 8/7/04 AND 8/11/04. MAINTENANCE REPLACED BATTERY ASSEMBLY PN 61-2274-1. UNIT PASSES CMM CHECKS. RETURNED TO SERVICE 8/17/04. REFER TO WO NR 373759 FOR ADDITIONAL INFORMATION.
- [SDR MALA040173](https://openairdocs.org/sdr/MALA040173.md): Relay · malfunctioned · Feb 5, 2004 · N534XJ · Bac AVRO146RJ85A · Windshield/Door Rain/Ice Removal
  > DURING FLIGHT 3500/3556/3542/3477, RT SCREEN HIGH TEMP LIGHT ON AND THE NR 2 ADC FAILED. AIR RETURN TO DTW. MAINTENANCE VERIFIED WIRES INSTALLED CORRECT. CHECKED RES AT ELEMENTS & THERM. CHECKED OUTPUT VOLT FROM NET FILTERS. CHECKED SYS WIRING. ALL CHECK
- [SDR MALA030503](https://openairdocs.org/sdr/MALA030503.md): Transceiver · malfunctioned · Nov 19, 2003 · N534XJ · Bac AVRO146RJ85A · Weather Radar System
  > DURING FLIGHT 3406, WEATHER RADAR FAILED INFLIGHT. AIR RETURN TO DTW. MAINTENANCE CND PROBLEM. CHANGED R/T AS A PRECAUTION, OP CHECKS GOOD.
- [SDR MALA030283](https://openairdocs.org/sdr/MALA030283.md): Escape Rope · loose · May 26, 2003 · N534XJ · Bac AVRO146RJ85A · Emergency Equipment
  > DURING FLIGHT 3645, ESCAPE ROPE PANEL KEEPS FALLING DOWN. MAINTENANCE APPLIED NEW HOOK AND LOOP TO THE AFFECTED AREA AS NEEDED SEC CHECKS GOOD.
- [SDR MALA020688](https://openairdocs.org/sdr/MALA020688.md): Spoiler · deployed · Dec 19, 2002 · N534XJ · Bac AVRO146RJ85A · Drag Control System
  > DURING FLIGHT 3657, AIR BRAKE DEPLOYED UNCOMMANDED. AIR RETURN TO MSP. MAINTENANCE PERFORMED ADJUSTMENT TEST PROCEDURES IAW AMM 27-63-00 501. ALL OPS CHECK GOOD. CLEANED CL4 POTENTIOMETER CANNON PLUG.
- [SDR MALA020470](https://openairdocs.org/sdr/MALA020470.md): Pump · failed · Aug 16, 2002 · N534XJ · Bac AVRO146RJ85A · Hydraulic Pump, Auxiliary
  > EN ROUTE ON FLIGHT 3566, YELLOW HYDRAULIC LIGHT TEMP ILLUMINATED. MAINTENANCE REPLACED AC PUMP IAW AMM 29-20-11 AND REPLACED YELLOW ISOLATION VALVE. OPS AND LEAK CHECKS, NO DEFECTS NOTED.
- [SDR MALA020248](https://openairdocs.org/sdr/MALA020248.md): Connector · defective · Apr 15, 2002 · N534XJ · Bac AVRO146RJ85A · Engine Oil Indicating System
  > ON APPROACH OF FLIGHT 3653, NR 4 ENGINE OIL PRESSURE DROP TO ZERO. LOW OIL PRESSURE LIGHT REMAIN OUT. AFTER LANDING PILOT SHUTDOWN ENGINE. LIGHT CAME ON AND INDICATED PRESSURE PEGGED OUT. MAINTENANCE REPLACED P1 CONNECTOR AT 442-00-00.
- [SDR MALA020227](https://openairdocs.org/sdr/MALA020227.md): Skin · chafed · Mar 22, 2002 · N534XJ · Bac AVRO146RJ85A · Trailing Edge Flaps
  > DURING C-CHECK IN CVG, THE LT O/B FLAP TAB SUFFERED CHAFE DAMAGE TO THE UPPER SKIN BETWEEN RIBS 11 & 12. DAMAGE REPAIRED IN ACCORDANCE WITH SRM 57-55-11 201 FIG 204 AND EO A57038.
- [SDR MALA020226](https://openairdocs.org/sdr/MALA020226.md): Angle · cracked · Mar 18, 2002 · N534XJ · Bac AVRO146RJ85A · Vertical Stabilizer Miscellaneous Structure
  > DURING C-CHECK IN CVG, CRACK ON RT SIDE OF LOWER VERTICAL STABILIZER, LOCATED AT STAB TO FUSELAGE CLOSING ANGLE. REPAIRED IN ACCORDANCE WITH BAE FAX BARA/AVR/5825/02-DC, RIL HC550H9004 ISS 3 AND EO A55013.
- [SDR MALA000343](https://openairdocs.org/sdr/MALA000343.md): Iru · failed · May 21, 2000 · N534XJ · Bac AVRO146RJ85A · Dependent Position Determining System
  > #1 IRS FAILED IN CRUISE. MX REMOVED AND REPLACED #1IRU. #1 IRU OPS CHECK GOOD.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N534XJ' AND deregistration_id = 'N534XJ-2007-05-18'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N534XJ-2007-05-18/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.