- [SDR HNAA2019121100382](https://openairdocs.org/sdr/HNAA2019121100382.md): Radar · failed · Dec 10, 2019 · N601DW · Emb EMB145LR · Weather Radar System
  > WX RADAR FAILED IN FLIGHT.AMBER WX INSCRIPTIONS AND GIVING ERRONEOUS READINGS.WX RADAR TEST FAILED....FIX:PERFORMED OPERATIONAL CHECK OF WX RTA REF. AMM 34-42-00-700-801-A OPS CHECK GOOD. OK FOR SERVICE
- [SDR HNAA20190607165](https://openairdocs.org/sdr/HNAA20190607165.md): Profile · gouged · Jun 7, 2019 · N601DW · Emb EMB145LR · Fuselage Main, Bulkhead
  > UPPER "L" PROFILE FRAME ON FWD PRESSURE BULKHEAD IS GOUGED NEAR CENTER POST... FIX: REMOVED PROFILE,REPAIRED PER ETD2019-145-072931, REINSTALLED PROFILE FRAME ON FWD PRESSURE BULKHEAD IAW ENB SRM 51-40-02
- [SDR HNAA2019060700164](https://openairdocs.org/sdr/HNAA2019060700164.md): Bulkhead Web · cracked · Jun 7, 2019 · N601DW · Emb EMB145LR · Fuselage Main, Bulkhead
  > FWD PRESSURE BULKHEAD CRACKED.... FIX:INSTALLED DOUBLER, FILLER AND SHIMS FOR REPAIR OF FWD PRESSURE BULKHEAD AT UPPER CENTER AREA IAW ETD2019-145-069777 REV A.
- [SDR HNAA2019060700163](https://openairdocs.org/sdr/HNAA2019060700163.md): Profile · cracked · Jun 7, 2019 · N601DW · Emb EMB145LR · Fuselage Main, Bulkhead
  > CENTER "T" PROFILE CRACKED ON THE FWD PRESSURE BULKHEAD,FWD FACE, UPPER AREA... FIX: INSTALLED NEW FWD PRESSURE BULKHEAD "T"PROFILE IAW EMB-145 SRM 51-40-02.
- [SDR HNAA2019061100171](https://openairdocs.org/sdr/HNAA2019061100171.md): Fitting · broken · Jun 2, 2019 · N601DW · Emb EMB145LR · Fuselage Main, Structure
  > WINDSHIELD CENTER POST LOWER FITTING BROKEN. R & R WINDSHIELD CENTER POST LOWER FITTING IAW EO1-53-19-0192 AND SB 145-53-007.
- [SDR HNAA2018090400210](https://openairdocs.org/sdr/HNAA2018090400210.md): Warning System · false activation · Aug 31, 2018 · N601DW · Emb EMB145LR · Pneumatic Indicating System
  > BLEED 1 VALVE CLOSED ADVISORY DISPLAYED AFTER T/O WITH VERY LOW BLEED TEPERATURE. RAN ENGINE 1 ON GROUND AT DIFFERENT THRUST SETTINGS AND PERFORMED ENG BLEED VALVE OPERATIONAL CHECK IAW AMM 36-11-05. NO ISSUES NOTED. OKAY FOR SERVICE.
- [SDR HNAA2018052100005](https://openairdocs.org/sdr/HNAA2018052100005.md): Inverter · inoperative · May 20, 2018 · N601DW · Emb EMB145LR · Emergency Lighting
  > FLOOR EMERGENCY LIGHTS INOPERATIVE AT THE EMERGENCY EXIT. R & R THE INVERTER IAW AMM 33-50-11.
- [SDR HNAA2018052500106](https://openairdocs.org/sdr/HNAA2018052500106.md): Fan · failed · May 6, 2018 · N601DW · Emb EMB145LR · Pneumatic Distribution System
  > BOTH BLEEDS OVERTEMP WARNINGS AT 16K, AFTER ICE PROTECTION HAD BEEN ON FOR 5 MINUTES. APU WAS NOT ON. REMOVED AND REPLACED THE NR 1 & 2 THERMOSTAT FAN A/C AND THERMOSTAT MOUNT TUB ASSY IAW SB 145-36-0028.
- [SDR HNAA2018043000092](https://openairdocs.org/sdr/HNAA2018043000092.md): Tube · failed · Apr 27, 2018 · N601DW · Emb EMB145LR · Compressor Bleed Control
  > BLEED 1 LEAK EICAS MESSAGE DISPLAYED DURING CLIMBOUT. REMOVED AND REPLACED THE TUBES IAW AMM 36-13-00. PERFORMED A BLEED AIR LEAK CHECK IAW AMM 36-00-00. PERFOMED AN EBV FUNCTIONAL CHECK IAW AMM 36-11-05. LEAK AND OPS CHECKED GOOD. OK FOR SERVICE.
- [SDR HNAA2018031600060](https://openairdocs.org/sdr/HNAA2018031600060.md): Indicator · malfunctioned · Mar 15, 2018 · N601DW · Emb EMB145LR · Altimeter, Barometric/Encoder
  > DURING CRUISE ALTITUDE, THE STBY ALTIMETER WAS INDICATING 1800 FEET LOWER THAN ADC AND THE STBY AIRSPEED INDICATOR WAS 25 KNOTS SLOWER THAN ADC. R & R THE STANDBY ALTIMETER IAW AMM 34-11-01. OPS CHECKED GOOD.
- [SDR HNAA2018021400031](https://openairdocs.org/sdr/HNAA2018021400031.md): Landing Gear · unknown · Feb 12, 2018 · N601DW · Emb EMB145LR · Nose/Tail Landing Gear
  > AT WHEELS UP, TWO LOUD THUMPING NOISES WERE HEARD COMING FROM NOSE AREA, ALONG WITH A HISSING SOUND. NO ABNORMAL INDICATIONS NOTED. EVALUATION FLIGHT SATISFACTORY.
- [SDR HNAA2018020700026](https://openairdocs.org/sdr/HNAA2018020700026.md): Bulb · inoperative · Feb 6, 2018 · N601DW · Emb EMB145LR · Emergency Lighting
  > OVERHEAD EMERGENCY LIGHT AT THE PAX DOOR WAS FOUND INOPERATIVE. R & R THE BULB.
- [SDR HNAA2017092500326](https://openairdocs.org/sdr/HNAA2017092500326.md): Brake · leaking · Sep 22, 2017 · N601DW · Emb EMB145LR · Landing Gear Brake System
  > LEFT BRAKES APPEAR TO BE SMOKING ON LANDING. NR 2 HYD QTY APPEARED TO BE DROPPING. FOUND THE LEFT MAIN BRAKE INBD LEAKING WHEN HYD PRESSURE IS APPLIED. R & R THE MAIN BRAKE ASSY IAW AMM 32-49-03. OPS CHECKED GOOD, OK FOR SERVICE.
- [SDR HNAA2017070500225](https://openairdocs.org/sdr/HNAA2017070500225.md): Warning Light · false activation · Jul 4, 2017 · N601DW · Emb EMB145LR · Central Warning
  > DURING NR 2 ENGINE START, NR 2 PITOT INOPERATIVE CAUTION MESSAGE CAME INTO VIEW. OPS CHECKED GOOD.
- [SDR HNAA2017070500227](https://openairdocs.org/sdr/HNAA2017070500227.md): Connector · dirty · Jul 1, 2017 · N601DW · Emb EMB145LR · Engine Indicating System
  > LOW PRESSURE COMPRESSION INDICATION AT HIGHEST POINT IN THE YELLOW RANGE. CLEANED THE FADEC 1A & 1B CONNECTORS IAW MM 70-00-00, RAN ACFT, NO DEFECTS NOTED.
- [SDR HNAA2017051200166](https://openairdocs.org/sdr/HNAA2017051200166.md): Display · malfunctioned · May 11, 2017 · N601DW · Emb EMB145LR · Navigation System
  > FIRST OFFICER`S ALTITUDE INDICATION MISSING ON PFD. TURNED OFF AVIONCIS AND PDU FOR 15 MIN. OPS CHECKED GOOD.
- [SDR SIMA20170125006](https://openairdocs.org/sdr/SIMA20170125006.md): Rib · cracked · Jan 25, 2017 · N601DW · Emb EMB145LR · Wing, Rib/Bulkhead
  > LT WING RIB 5 CRACKED. REPLACED LT RIB 5 IAW ERS EO EM-57MR-764.
- [SDR SIMA20170123007](https://openairdocs.org/sdr/SIMA20170123007.md): Skin · damaged · Jan 23, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Plate/Skin
  > FRAME 60 -61 PROTRUSION AT STRINGER 17L. ACCOMPLISHED REPAIR TO FRAME 60 - 61 AT STRINGER 17L IAW ERS-EM-53MR-2555.
- [SDR SIMA20170122004](https://openairdocs.org/sdr/SIMA20170122004.md): Drag Angle · cracked · Jan 22, 2017 · N601DW · Emb EMB145LR · Fuselage, Stabilizer Attach Fittings
  > VERTICAL STAB LT DRAG ANGLE CRACKED AFT OF FR 75 PREVIOUS REPAIR. PERFORMED PERMANENT REPAIR OF VERTICAL STAB LT DRAG ANGLE AFT OF FR 75 IAW SRM 51-40-02.
- [SDR SIMA20170121003](https://openairdocs.org/sdr/SIMA20170121003.md): Frame · gouged · Jan 21, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Frame
  > FRAME 65 PREVIOUS REPAIR GOUGED BTW STR 12R - 13R. PERFORMED PERMANENT REPAIR ON FR 65 BTW STR 12R-13R IAW ERS-EM-53MR-2545.
- [SDR SIMA20170121002](https://openairdocs.org/sdr/SIMA20170121002.md): Floorbeam · corroded · Jan 21, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Floor Beam
  > LT FLOORBEAM WEB CORRODED AT CENTER AISLE CROSSMEMBER AT FR 29. PERFORMED PERMANENT REPAIR OF CENTER AISLE CROSSMEMBER AT FR 29 IAW ERS-EM-53MR-2552
- [SDR SIMA20170120004](https://openairdocs.org/sdr/SIMA20170120004.md): Skin · canning · Jan 20, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Plate/Skin
  > FUSELAGE SKIN HAS PROTRUSION AND OIL CANNING BETWEEN FRAMES 7 AND 8 STR 13L - 15L. PERFORMED PERMANENT REPAIR OF FR 7-8 STR 13L-15L IAW ERS-EM-53MR-2522.
- [SDR SIMA20170116003](https://openairdocs.org/sdr/SIMA20170116003.md): Floorbeam · corroded · Jan 16, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Floor Beam
  > LT FLOORBEAM WEB CORRODED AT CENTER AISLE CROSSMEMBER AT FR 38. PERFORMED PERMANENT REPAIR OF CENTER AISLE CROSSMEMBER AT FR 38 IAW SRM 53-00-10 ITEM 3 FIG 202 SHEET 1.
- [SDR SIMA20161218005](https://openairdocs.org/sdr/SIMA20161218005.md): Inverter · failed · Dec 18, 2016 · N601DW · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT ABOVE SERVICE DOOR INOPERATIVE. REMOVED AND REPLACED THE INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD IAW AMM 33-50-00.
- [SDR SIMA20161129002](https://openairdocs.org/sdr/SIMA20161129002.md): Flashlight · inoperative · Nov 29, 2016 · N601DW · Emb EMB145LR · Emergency Equipment
  > CABIN FLASHLIGHT HAS NO RED CHARGE LIGHT. REMOVED AND REPLACED CABIN FLASH LIGHT IAW STANDARD MTX PRACTICES.
- [SDR SIMA20160807001](https://openairdocs.org/sdr/SIMA20160807001.md): Warning Message · false activation · Aug 7, 2016 · N601DW · Emb EMB145LR · Landing Gear Brake System
  > ON PUTTING GEAR DOWN FOR FINAL APPROACH, EICAS MESSAGE BRAKE DEGRADE. WENT AROUND DID AOM1 CHECKLIST. DECLARED EMERGENCY AND LANDED WITHOUT INCINDENT. PERFORMED MAIN BRAKE FUNCTIONAL CHECK IAW AMM 32-41-00. FNC FAILED AT STEP J.2.H. CONTINUED FROM AMM 32-4
- [SDR SIMA20160708004](https://openairdocs.org/sdr/SIMA20160708004.md): Wire · damaged · Jul 8, 2016 · N601DW · Emb EMB145LR · Light System Wiring
  > EMERGENCY LIGHT IN THE SERVICE DOOR INOPERATIVE. REPAIRED WIRE FOR SERVICE DOOR AT SPLICE SP7376 IAW SWPM 20-21-00, EMERGENCY LIGHTS OPS CHECK GOOD IAW AMM 33-50-00.
- [SDR SIMA20160425001](https://openairdocs.org/sdr/SIMA20160425001.md): Holder · defective · Apr 25, 2016 · N601DW · Emb EMB145LR · Emergency Equipment
  > FIRST OFFICERS FLASHLIGHT NOT SECURE TO FLASHLIGHT BASE. R & R FIRST OFFICERS FLASHLIGHT BASE IAW AMM 33-50-16.
- [SDR SIMA20160311004](https://openairdocs.org/sdr/SIMA20160311004.md): Hydraulic Line · cracked · Mar 11, 2016 · N601DW · Emb EMB145LR · Hydraulic System, Main
  > EMERGENCY HYD BRAKE LINE, UNDER COCKPIT FLOOR CRACKED & LEAKING. REPAIRED EMER HYD BRAKE LINE IAW AMM 20-10-03. LEAK & OPERATIONS CHECKED GOOD.
- [SDR SIMA20160226001](https://openairdocs.org/sdr/SIMA20160226001.md): Holder · broken · Feb 26, 2016 · N601DW · Emb EMB145LR · Emergency Equipment
  > FORWARD FLIGHT ATTENDANT FLASHLIGHT HOLDER IS BROKEN & DOES NOT HOLD FLASHLIGHT PROPERLY. R & R FLASHLIGHT ASSEMBLY IAW AMM 33-50-16, NO DEFECT NOTED.
- [SDR SIMA20160208001](https://openairdocs.org/sdr/SIMA20160208001.md): Cradle · inoperative · Feb 8, 2016 · N601DW · Emb EMB145LR · Emergency Equipment
  > AFT FLASHLIGHT INOPERATIVE. CHANGE FLASHLIGHT HOLDER.
- [SDR SIMA20151226002](https://openairdocs.org/sdr/SIMA20151226002.md): Splice · defective · Dec 26, 2015 · N601DW · Emb EMB145LR · Light System Wiring
  > SERVICE DOOR EMER LIGHT INOPERATIVE. R & R REMOVABLE SPLICE AT SERVICE DOOR EMER EXTERNAL LIGHT IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150925001](https://openairdocs.org/sdr/SIMA20150925001.md): Pressure Switch · malfunctioned · Sep 25, 2015 · N601DW · Emb EMB145LR · Rudder Control System
  > YAW DAMP FAIL. R & R RUDDER SYS 2 PRESS SWITCH IAW AMM 27-23-04. PERFORMED LEAK CHECK, LEAK CHECKED GOOD. PERFORMED OPERATIONS CHECK RUDDER SYS 2 IAW AMM 27-263-00. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150917001](https://openairdocs.org/sdr/SIMA20150917001.md): Flashlight · inoperative · Sep 17, 2015 · N601DW · Emb EMB145LR · Emergency Equipment
  > CAPTAINS FLASHLIGHT NOT CHARGING. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16. 0PERATIONS CHECKED GOOD.
- [SDR SIMA20150522002](https://openairdocs.org/sdr/SIMA20150522002.md): Battery · discharged · May 22, 2015 · N601DW · Emb EMB145LR · Emergency Lighting
  > MULTIPLE CABIN EMER LIGHTS INOPERATIVE. SUSPECT PROBLEM WITH EPSU NR 3. R & R NR 3 EMER LIGHT BATTERY & CHARGER IAW WC 33-700-19. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED AT THIS TIME.
- [SDR SIMA20150521003](https://openairdocs.org/sdr/SIMA20150521003.md): Inverter · inoperative · May 21, 2015 · N601DW · Emb EMB145LR · Emergency Lighting
  > COCKPIT STEP EMER LIGHT INOPERATIVE. R & R EMER LIGHT DC & AC INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150508004](https://openairdocs.org/sdr/SIMA20150508004.md): Light · inoperative · May 8, 2015 · N601DW · Emb EMB145LR · Emergency Lighting
  > EMERGENCY LIGHT STRIP ON FLOOR BY 6A INOPERATIVE. R & R EMER LIGHT STRIP BY 6A IAW AMM 33-50-12. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.
- [SDR SIMA20150504003](https://openairdocs.org/sdr/SIMA20150504003.md): Light · inoperative · May 4, 2015 · N601DW · Emb EMB145LR · Emergency Equipment
  > FIRST OFFICERS FLASHLIGHT INOPERATIVE. TROUBLE SHOT FIRST OFFICERS FLASHLIGHT, FOUND LAMP BURNED OUT. R & R LAMP IAW CMM 25-60-11.
- [SDR SIMA20150429001](https://openairdocs.org/sdr/SIMA20150429001.md): Battery · discharged · Apr 29, 2015 · N601DW · Emb EMB145LR · Emergency Lighting
  > 1/2 OF EMER LIGHTING NOT WORKING. R & R NR 4 EMER BATTERY ASSEMBLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.
- [SDR SIMA20150325001](https://openairdocs.org/sdr/SIMA20150325001.md): Inverter · inoperative · Mar 25, 2015 · N601DW · Emb EMB145LR · Emergency Lighting
  > ESCAPE PATH EMER LIGHTING ON LT SIDE ROWS 7 - 15 OTS. R & R NR 4 AC TO DC INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150308003](https://openairdocs.org/sdr/SIMA20150308003.md): Light · inoperative · Mar 8, 2015 · N601DW · Emb EMB145LR · Emergency Lighting
  > CABIN NR 5 FLOOR PROXIMITY STRIP LIGHT INOPERATIVE. R & R CABIN NR 5 FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.
- [SDR SIMA20150303005](https://openairdocs.org/sdr/SIMA20150303005.md): Sleeve · blown · Mar 3, 2015 · N601DW · Emb EMB145LR · Cabin Cooling System
  > WHILE RUNNING PROCEDURES FOR ITEM NR 1, RECEIVED PACK 2 OVLD, FOLLOWED BY BURNING SMELL. FOUND BLOWN SLEEVE FWD OF D C V CAUSING BURNING SMELL. R & R SLEEVE AMM 21-60-01. LEAK CHECK & OPERATIONS CHECKED GOOD AT THIS TIME.
- [SDR SIMA20150303004](https://openairdocs.org/sdr/SIMA20150303004.md): Clamp · failed · Mar 3, 2015 · N601DW · Emb EMB145LR · Cabin Cooling System
  > DURING CLIMB CREW RECEIVED PACK 1 OVLD MSG FOLLOWED BY PACK 1 OVLD MSG. CREW COMPLIED WITH AOM VOL 1 PROCEDURES, DECLARED AN EMER & RETURNED WITHOUT INCIDENT. FOUND BROKEN CLAMP AT PACK 1 VALVE. R & R CLAMP IAW AMM 21-51-01. LEAK & OPS CHECKED GOOD.
- [SDR SIMA20150104005](https://openairdocs.org/sdr/SIMA20150104005.md): Skin · cracked · Jan 4, 2015 · N601DW · Emb EMB145LR · Fuselage Main, Plate/Skin
  > FRAME 75 FASTENER SKIN AREA CRACKED BELOW STRINGER 2L. ACCOMPLISHED FRAME 75 BELOW STRINGER 2L SKIN REPAIR IAW ERS-EM-53MR-984.
- [SDR SIMA20150104006](https://openairdocs.org/sdr/SIMA20150104006.md): Skin · cracked · Jan 4, 2015 · N601DW · Emb EMB145LR · Fuselage Main, Plate/Skin
  > FRAME 75 SKIN AT FASTENER AREA CRACKED ABOVE STRINGER 2R. ACCOMPLISHED FRAME 75 ABOVE STRINGER 2R SKIN REPAIR IAW ERS-EM-53MR-984.
- [SDR SIMA20150103002](https://openairdocs.org/sdr/SIMA20150103002.md): Spar · cracked · Jan 3, 2015 · N601DW · Emb EMB145LR · Wing Spar
  > CRACK ON LT WING SPAR III AT HOLE FOR MLG HARNESS AT APPROX THE 7 O'CLOCK POSITION BETWEEN RIBS 3 & 4. ACCOMPLISHED REPAIR ON LT WING SPAR III AT HOLE FOR MLG HARNESS IAW ERS-EM-57MR-349. FOUND DURING EO-EM-5700-662.
- [SDR SIMA20150103003](https://openairdocs.org/sdr/SIMA20150103003.md): Spar · cracked · Jan 3, 2015 · N601DW · Emb EMB145LR · Wing Spar
  > CRACK ON RT WING SPAR III AT HOLE FOR MLG HARNESS AT APPROX THE 4 O'CLOCK POSITION BETWEEN RIBS 3 & 4. ACCOMPLISHED REPAIR ON RT WING SPAR III AT HOLE FOR MLG HARNESS IAW ERS-EM-57MR-350. FOUND DURING EO-EM-5700-662.
- [SDR SIMA20150102011](https://openairdocs.org/sdr/SIMA20150102011.md): Support · cracked · Jan 2, 2015 · N601DW · Emb EMB145LR · Engine Mount Section
  > LEFT PYLON FWD LOWER YOKE FWD ENG MOUNT SUPPORT IS CRACKED. ACCOMPLISHED REPAIR TO LT PYLON FWD LOWER YOKE FWD ENG MOUNT SUPPORT IAW EO-EM-54MR-386 PART A.
- [SDR SIMA20150102012](https://openairdocs.org/sdr/SIMA20150102012.md): Door Frame · corroded · Jan 2, 2015 · N601DW · Emb EMB145LR · Fuselage Main, Structure
  > SERVICE DOOR FRAME CORRODED BELOW AFT LOWER ROLLER. PERFORMED SERVICE DOOR FRAME CORROSION REPAIR IAW ERS EM -53MR-971.
- [SDR SIMA20150102009](https://openairdocs.org/sdr/SIMA20150102009.md): Connector · missing · Jan 2, 2015 · N601DW · Emb EMB145LR · Light System Wiring
  > WIRE FOR FLOOR PROXIMITY LIGHT STRIP NR 4 IS MISSING CONNECTOR WHERE IT PASSES THRU THE FLOORBOARD. INSTALLED CONNECTOR TO NR 4 PROXIMITY LIGHT STRIP IAW SWPM 20-21-0. FOUND DURING OPEN UP.

Next page: https://openairdocs.org/deregistered/N601DW-2021-01-07/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N601DW' AND deregistration_id = 'N601DW-2021-01-07'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N601DW-2021-01-07/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.