# Service difficulty reports: N703BR, cancelled Sep 2, 2009

A list on [N703BR, cancelled Sep 2, 2009](https://openairdocs.org/deregistered/N703BR-2009-09-02.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR 05056703](https://openairdocs.org/sdr/05056703.md): Warning Light · illuminated · Feb 25, 2005 · N703BR · Cndair CL6002B19 · Stabilizer Position Indicating
  > EVENT SUMMARY STATED MACH TRIM FAILURE MSG AND STAB TRIM MSG. WO CA: C/W BOMBARDIER SL 27-083.
- [SDR 050327032](https://openairdocs.org/sdr/050327032.md): Striker · dented · Feb 1, 2005 · N703BR · Cndair CL6002B19 · Passenger/Crew Doors
  > PAX DOOR SEAL STRIKER PLATE DENTED FROM IMPACT WITH DOOR PINS.
- [SDR 050327037](https://openairdocs.org/sdr/050327037.md): Plate · corroded · Feb 1, 2005 · N703BR · Cndair CL6002B19 · Fuselage Miscellaneous Structure
  > CARGO LANDING PLATE CORRODED AROUND NUT PLATES ON TOP SURFACE.
- [SDR 050327036](https://openairdocs.org/sdr/050327036.md): Angle · cracked · Feb 1, 2005 · N703BR · Cndair CL6002B19 · Fuselage Miscellaneous Structure
  > RIGHT OBLIQUE ANGLE AT FS 625 CRACKED.
- [SDR 050327035](https://openairdocs.org/sdr/050327035.md): Angle · cracked · Feb 1, 2005 · N703BR · Cndair CL6002B19 · Fuselage Miscellaneous Structure
  > LEFT OBLIQUE ANGLE AT FS 625 CRACKED.
- [SDR 050327034](https://openairdocs.org/sdr/050327034.md): Intercostal · cracked · Feb 1, 2005 · N703BR · Cndair CL6002B19 · Fuselage Miscellaneous Structure
  > INTERCOSTAL CRACK ON OUTBOARD SIDE AT FS 484 RIGHT.
- [SDR 050327033](https://openairdocs.org/sdr/050327033.md): Intercostal · cracked · Feb 1, 2005 · N703BR · Cndair CL6002B19 · Fuselage Miscellaneous Structure
  > INTERCOSTAL CRACKED ON INBOARD SIDE AT FS 484 LEFT.
- [SDR 050327031](https://openairdocs.org/sdr/050327031.md): Plate · cracked · Feb 1, 2005 · N703BR · Cndair CL6002B19 · Cargo/Baggage Doors
  > CARGO LANDING PLATE CRACKED AT RIVETS ATTACHING IT TO INTERCOSTALS.
- [SDR 05031703](https://openairdocs.org/sdr/05031703.md): Support · cracked · Jan 31, 2005 · N703BR · Cndair CL6002B19 · Engine Mount Section
  > ENGINE SUPPORT BEAM CRACKED ON RIGHT HAND LOWER ACCESS PANEL CUTOUT. INBOARD FORWARD EDGE AT 75 IN LENGTH AT RBL 36.2 WATER LINE 111.09
- [SDR 05017703](https://openairdocs.org/sdr/05017703.md): Smoke Detector · intermittent · Jan 17, 2005 · N703BR · Cndair CL6002B19 · Smoke Detection
  > LAV SMOKE INDICATION MOMENTARY ON TAKEOFF. NO SMOKE ODOR PRESENT. MX INSPECTED COALESCER BAGS. NO OIL NOTED.
- [SDR 04328703](https://openairdocs.org/sdr/04328703.md): Smoke Detector · faulty · Nov 23, 2004 · N703BR · Cndair CL6002B19 · Smoke Detection
  > TOILET SMOKE IND ON CLIMB-OUT. ODOR BEGAN SHORTLY AFTER THROTTLES FORWARD FOR T/O NO VISIBLE SMOKE. ODOR WAS MORE OF A MUSTY SMELL, NOT OIL OR BURNING. MX FOUND FAULTY SMOKE DETECTOR. ALSO, REPLACED BOTH COALESCER SOCKS. PERFORMED ENGINE RUNS AT POWER WIT
- [SDR 04295703](https://openairdocs.org/sdr/04295703.md): Valve · malfunctioned · Oct 21, 2004 · N703BR · Cndair CL6002B19 · Pneumatic Distribution System
  > EVENT SUMMARY STATED LAV SMOKE DETECTOR AURAL WARNING. INSPECT LAV SMOKE DETECTOR CONNECTOR AND WIRING. REMOVED AND REPLACED SPINNER. PERFORM FIM. INSPECT 10TH STAGE DUCT AND DUCTS TO ACM. PERFORMED BORESCOPE INSPECTION. INSTALLED 2 FAN BLADES. REMOVE
- [SDR 04292703](https://openairdocs.org/sdr/04292703.md): Line · leaking · Oct 18, 2004 · N703BR · Cndair CL6002B19 · Pneumatic Indicating System
  > EVENT SUMMARY STATED THAT SMOKE IN THE LAV INDICATION, EMERGENCY DECLARED. REMOVED AND REPLACED 10TH STAGE BLEED LINES. DID LEAK CHECK.
- [SDR 04289703](https://openairdocs.org/sdr/04289703.md): Smoke · detected · Oct 15, 2004 · N703BR · Cndair CL6002B19 · Air Distribution System
  > EVENT SUMMARY STATES SMOKE INDICATION/ODOR IN LAV, RTF. IN APPR STATUS.
- [SDR 04287703](https://openairdocs.org/sdr/04287703.md): Acm · smoke · Oct 13, 2004 · N703BR · Cndair CL6002B19 · Cabin Cooling System
  > EVENT SUMMARY STATES THAT RETURN FROM FLIGHT. SMOKE TOILET CAUTION MSG AFTER TAKEOFF. SMOKE VISIBLE IN TOILET AND AFT CABIN. REMOVED AND REPLACED RT ACM REF MM 21-52-00 AND REMOVED AND REPLACED WATER SEPARATOR SOCK REF MM 21-52-00.
- [SDR 04283703](https://openairdocs.org/sdr/04283703.md): Fan · smoke · Oct 9, 2004 · N703BR · Cndair CL6002B19 · Air Distribution System
  > LAV SMOKE INDICATION WITH FAINT HAZE. SMOKE DISAPPEARED AFTER C/BS PULLED FOR QRH. MX REMOVED AND REPLACED LAV EXHAUST FAN AND SMOKE DETECTOR.
- [SDR 04277703](https://openairdocs.org/sdr/04277703.md): Apu · contaminated · Oct 3, 2004 · N703BR · Cndair CL6002B19 · APU Core Engine
  > LAV SMOKE INDICATION. DECLARED EMERGENCY RTF, LANDED SAFELY. MX PERFORMED ENGINE RUN WITH APU ON, GOT OIL SMELL AND FOUND OIL IN APU ENCLOSURE.
- [SDR 04187703](https://openairdocs.org/sdr/04187703.md): Bulb · burned out · Jul 5, 2004 · N703BR · Cndair CL6002B19 · Emergency Lighting
  > DURING INSPECTION THE LEFT HAND OVERWING EMERGENCY LIGHT WAS FOUND INOPERATIVE. THE BULB WAS REPLACED AND A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED. AIRCRAFT WAS RETURNED TO SERVICE.
- [SDR 03339703](https://openairdocs.org/sdr/03339703.md): Light · inoperative · Dec 5, 2003 · N703BR · Cndair CL6002B19 · Emergency Lighting
  > DURING INSPECTION THE FLOOR EMERGENCY LIGHTS WERE DIM. THE POWER STRIP WAS FOUND INOPERATIVE AND WAS REPLACED. A SATISFACTORY OPERATIONAL CHECK WAS PERFORMED AND THE AIRCRAFT WAS RELEASED FOR CONTINUED SERVICE.
- [SDR 03202703](https://openairdocs.org/sdr/03202703.md): Light · inoperative · Jul 21, 2003 · N703BR · Cndair CL6002B19 · Emergency Lighting
  > DURING MAINTENANCE INSPECTION, AN EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE EMERGENCY EXIT LAMP. A SATISFACTORY OPERATIONAL CHECK WAS PERFORMED AND AIRCRAFT WAS RELEASED FOR CONTINUED SERVICE.
- [SDR 03124703](https://openairdocs.org/sdr/03124703.md): Bulb · burned out · May 4, 2003 · N703BR · Cndair CL6002B19 · Emergency Lighting
  > DURING MAINTENANCE INSPECTION, THE LT OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE LAMP IN THE EMERGENCY EXIT LIGHT. AN OPERATIONAL CHECK WAS SATISFACTORY AND THE AIRCRAFT WAS RETURNED TO SERVICE.
- [SDR 02234703](https://openairdocs.org/sdr/02234703.md): Lamp · Aug 22, 2002 · N703BR · Cndair CL6002B19 · Emergency Lighting
  > During preflight inspection, the crew reported that the L/H overwing exterior emergency exit light was inoperative. Maintenance personnel removed and replaced the lamp in the L/H overwing exterior emergency exit light. An operational check was satisfactory a
- [SDR 02179703](https://openairdocs.org/sdr/02179703.md): Light · inoperative · Jun 28, 2002 · N703BR · Cndair CL6002B19 · Emergency Lighting
  > DURING PREFLIGHT INSPECTION, THE CREW NOTED THAT THE CEILING EMERGENCY EXIT LIGHTED SIGN WAS INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE LIGHT BULB. AN OPERATIONAL CHECK OF THE EMERGENCY EXIT LIGHTING SYSTEM WAS SATISFACTORY AND THE AIRCRAFT

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N703BR' AND deregistration_id = 'N703BR-2009-09-02'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N703BR-2009-09-02/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.