# Service difficulty reports: N762P, cancelled Jul 18, 2017

A list on [N762P, cancelled Jul 18, 2017](https://openairdocs.org/deregistered/N762P-2017-07-18.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

- [SDR HEEA116405](https://openairdocs.org/sdr/HEEA116405.md): Bracket · loose · Jul 11, 2007 · N762P · Skrsky S76A · Fuselage Main, Attach Fittings
  > LANDING GEAR WOULD NOT RETRACT. FOUND NOSE WHEEL CENTERING PROXIMITY SWITCH BRACKET LOOSE. TIGHTENED BRACKET AND CHECKED AND ADJUSTED SWITCH GAP.
- [SDR HEEA111625](https://openairdocs.org/sdr/HEEA111625.md): Connector · contaminated · Oct 21, 2006 · N762P · Skrsky S76A · Electrical Power System Wiring
  > ENROUTE, NR1 N1 GAUGE WOULD FAIL TO 0 AND THEN WOULD WORK AGAIN. THIS CYCLE WAS CONTINUOUS EACH TIME THE N1 GAUGE WOULD FAIL, THE AC GENERATOR WOULD FAIL ALSO. TURNED OFF THE AC GENERATOR. DRIED MOISTURE IN CONNECTOR IN N1 PICKUP.
- [SDR HEEA107328](https://openairdocs.org/sdr/HEEA107328.md): Bolt · frozen · Oct 5, 2005 · N762P · Skrsky S76A · Main Landing Gear
  > AFTER TAKEOFF, LANDING GEAR WAS RETRACTED. RED UNSAFE LIGHT DID NOT GO OUT. LANDING GEAR WAS EXTENDED, GOT THREE GREEN AND LANDED AT LFT. MAINTENANCE FOUND MAIN LANDING GEAR TIEDOWN RING ATTACHMENT BOLT FROZEN, CAUSING TIEDOWN RING TO NOT BE FREE TO SPRING
- [SDR HEEA107342](https://openairdocs.org/sdr/HEEA107342.md): Hinge · missing · Apr 8, 2005 · N762P · Skrsky S76A · Fuselage, Door Hinge
  > DURING CRUISE FLIGHT A LOUD NOISE WAS HEARD. RETURNED TO CAMERON. MAINTENANCE FOUND THE ACCESS DOOR AND HINGE PIN MISSING FROM THE FRONT OF THE FORWARD COWLING. REPLACED HINGE.
- [SDR HEEA088428](https://openairdocs.org/sdr/HEEA088428.md): Fitting · broken · Aug 2, 2003 · N762P · Skrsky S76A · Passenger/Crew Doors
  > CREW DOOR FITTING BROKEN. SCRAPPED.
- [SDR HEEA088393](https://openairdocs.org/sdr/HEEA088393.md): Control Box · inoperative · Jul 30, 2003 · N762P · Skrsky S76A · Automatic Direction Finder (ADF) System
  > ADF SYSTEM CONTROL BOX INOPERATIVE. IN SHOP REPAIR.
- [SDR HEEA088422](https://openairdocs.org/sdr/HEEA088422.md): Motor · malfunctioned · Jul 11, 2003 · N762P · Skrsky S76A · Engine Controls
  > STICKS ON LOW SIDE GOING UP. TO BE SENT TO VENDOR FOR REPAIR.
- [SDR HEEA088365](https://openairdocs.org/sdr/HEEA088365.md): Indicator · sticking · Jul 6, 2003 · N762P · Skrsky S76A · Directional Gyro and Indicating System
  > COMPASS CARD STICKS.
- [SDR HEEA088041](https://openairdocs.org/sdr/HEEA088041.md): Gcu · malfunctioned · Jul 4, 2003 · N762P · Skrsky S76A · AC Generation System
  > GCU HAS SLIGHT DELAY TO COME ON LINE.
- [SDR HEEA088430](https://openairdocs.org/sdr/HEEA088430.md): Transceiver · malfunctioned · Jul 3, 2003 · N762P · Skrsky S76A · VHF Communications System
  > EMITS LOUD POPPING SOUND AND TRANSMITS AND RECEIVE GARBLED. REPLACED BAD I305 IC CHIP. REPAIRED PROBLEM. REMOVED CORROSION FROM CHASSIS. ADJUSTED C/N SQUELCH AND REALIGNED TRANSMITTER. BENCH CHECK GOOD.
- [SDR HEEA088043](https://openairdocs.org/sdr/HEEA088043.md): Generator · inoperative · Jul 3, 2003 · N762P · Skrsky S76A · AC Generation System
  > GENERATOR INOPERATIVE.
- [SDR HEEA088036](https://openairdocs.org/sdr/HEEA088036.md): Transceiver · malfunctioned · Jul 3, 2003 · N762P · Skrsky S76A · VHF Communications System
  > TRANSCEIVER EMITS LOUD POPPING SOUND AND TRANSMITS AND RECEIVES GARBLED. SHOP REPAIR.
- [SDR HEEA088035](https://openairdocs.org/sdr/HEEA088035.md): Transceiver · malfunctioned · Jul 2, 2003 · N762P · Skrsky S76A · VHF Communications System
  > VHF TRANCEIVER HAS GARBLED TRANSMISSION. SHOP REPAIR.
- [SDR HEEA087798](https://openairdocs.org/sdr/HEEA087798.md): Interphone · malfunctioned · Jun 14, 2003 · N762P · Skrsky S76A · Audio Integrating System
  > INTERPHONE BOX HAS BACKGROUND NOISE FROM FM RADIO. SHOP REPAIR.
- [SDR HEEA087797](https://openairdocs.org/sdr/HEEA087797.md): Interphone · inoperative · Jun 14, 2003 · N762P · Skrsky S76A · Audio Integrating System
  > INTERPHONE BOX HAS BACKGROUND NOISE FROM FM RADIO. SHOP REPAIR.
- [SDR HEEA087511](https://openairdocs.org/sdr/HEEA087511.md): Transceiver · malfunctioned · Jun 12, 2003 · N762P · Skrsky S76A · Weather Radar System
  > TRANSCEIVER HAS STATIC IN FLIGHT. SHOP REPAIR.
- [SDR HEEA087142](https://openairdocs.org/sdr/HEEA087142.md): Interphone · malfunctioned · Jun 10, 2003 · N762P · Skrsky S76A · Interphone/Passenger Announcement (PA) System
  > FM NR 1 AND 2 RECEIVE SELECTOR SWITCHES ARE OPPOSITE. COULD NOT VERIFY COMPLAINT. FOUND SWITCH S1 NOISY AND CAPACITOR C30 BAD. REPLACED. REPAIRED. BENCH CHECK GOOD.
- [SDR HEEA087129](https://openairdocs.org/sdr/HEEA087129.md): Control Head · stuck · Jun 10, 2003 · N762P · Skrsky S76A · Weather Radar System
  > TEST SWITCH STICKS INTERMITTENTLY. SHOP REPAIR.
- [SDR HEEA087128](https://openairdocs.org/sdr/HEEA087128.md): Transceiver · malfunctioned · Jun 10, 2003 · N762P · Skrsky S76A · Weather Radar System
  > CAUSES STATIC IN OTHER RADIOS. HAS LIMITED TRANSMIT RANGE IN FLIGHT. SHOP REPAIR.
- [SDR HEEA087126](https://openairdocs.org/sdr/HEEA087126.md): Controller · malfunctioned · Jun 10, 2003 · N762P · Skrsky S76A · DME/TACAN System
  > CONTROLLER CAUSING DME PROBLEM. SHOP REPAIR.
- [SDR HEEA087125](https://openairdocs.org/sdr/HEEA087125.md): Receiver · erratic · Jun 10, 2003 · N762P · Skrsky S76A · DME/TACAN System
  > DME OUTPUT IS ERRATIC. SHOP REPAIR.
- [SDR HEEA087124](https://openairdocs.org/sdr/HEEA087124.md): Transceiver · malfunctioned · Jun 10, 2003 · N762P · Skrsky S76A · VHF Communications System
  > VHF TRANSCEIVER HAS A POPPING SOUND. SHOP REPAIR.
- [SDR HEEA086568](https://openairdocs.org/sdr/HEEA086568.md): Control Unit · inoperative · May 22, 2003 · N762P · Skrsky S76A · AC Generation System
  > AC GENERTOR DELAYED COMING ON LINE. SENT FOR INSPECTION AND REPAIR.
- [SDR HEEA086567](https://openairdocs.org/sdr/HEEA086567.md): Inverter · intermittent · May 22, 2003 · N762P · Skrsky S76A · AC Inverter
  > INTERMITTENT INVERTER WARNING LIGHT. SENT FOR INSPECTION AND REPAIR.
- [SDR HEEA086563](https://openairdocs.org/sdr/HEEA086563.md): Blade · chipped · May 22, 2003 · N762P · Skrsky S76A · Main Rotor Blades
  > TRAILING EDGE CHIPPED 1.5 IN. FROM TRIM TAB. REPLACED WITH SERVICEABLE PART.
- [SDR HEEA086553](https://openairdocs.org/sdr/HEEA086553.md): Valve · popped · May 22, 2003 · N762P · Skrsky S76A · Engine Bleed Air System
  > END OF SWIVEL FITTING POPPED OFF WHEN INSTALLING. TO BE SENT TO VENDOR FOR REPAIR.
- [SDR HEEA086551](https://openairdocs.org/sdr/HEEA086551.md): Indicator · inoperative · May 22, 2003 · N762P · Skrsky S76A · Rate of Climb Indicator
  > INDICATOR INTERMITTENTLY INOPERATIVE AND WILL READ 300 FEET PER MINUTE ERROR. TO BE SENT TO VENDOR FOR REPAIR.
- [SDR HEEA086548](https://openairdocs.org/sdr/HEEA086548.md): Commutator · damaged · May 22, 2003 · N762P · Skrsky S76A · Starter-Generator
  > RECEIVED FOR COMMUTATOR SPOT. INSPECTED BY ACCESSORY SHOP FOUND UNIT HAD EXCESSIVE BRUSH WEAR.
- [SDR HEEA086543](https://openairdocs.org/sdr/HEEA086543.md): Control Unit · malfunctioned · May 22, 2003 · N762P · Skrsky S76A · Automatic Direction Finder (ADF) System
  > ADF CONTROL UNIT IS UNREADABLE. IN SHOP REPAIR.
- [SDR HEEA086542](https://openairdocs.org/sdr/HEEA086542.md): Control Unit · malfunctioned · May 22, 2003 · N762P · Skrsky S76A · Automatic Direction Finder (ADF) System
  > ADF CONTROL UNIT IS UNREADABLE. IN SHOP REPAIR.
- [SDR HEEA086541](https://openairdocs.org/sdr/HEEA086541.md): Control Unit · malfunctioned · May 22, 2003 · N762P · Skrsky S76A · VHF Communications System
  > VHF SYSTEM CONTROL UNIT IS UNREADABLE. IN SHOP REPAIR.
- [SDR HEEA086540](https://openairdocs.org/sdr/HEEA086540.md): Controller · malfunctioned · May 22, 2003 · N762P · Skrsky S76A · Automatic Direction Finder (ADF) System
  > ADF CONTROLLER IS UNREADABLE. IN SHOP REPAIR.
- [SDR HEEA086537](https://openairdocs.org/sdr/HEEA086537.md): Transceiver · inoperative · May 22, 2003 · N762P · Skrsky S76A · VHF Communications System
  > VHF TRANSCEIVER INOPERATIVE. IN SHOP REPAIR.
- [SDR HEEA086530](https://openairdocs.org/sdr/HEEA086530.md): Indicator · reads low · May 22, 2003 · N762P · Skrsky S76A · Fuel Flow Sensor
  > NR 1 FUEL FLOW INDICATOR READS LOW.
- [SDR HEEA086517](https://openairdocs.org/sdr/HEEA086517.md): Indicator · erratic · May 21, 2003 · N762P · Skrsky S76A · Weather Radar System
  > RADAR ALTIMETER INDICATOR IS ERRATIC AND HAS UNRELIABLE NEEDLE MOVEMENT. SENT TO HONEYWELL, TEXAS FOR INSPECTION AND REPAIR.
- [SDR HEEA086511](https://openairdocs.org/sdr/HEEA086511.md): Indicator · inaccurate · May 21, 2003 · N762P · Skrsky S76A · Altimeter, Barometric/Encoder
  > COPILOT ALTIMETER READS 100 FEET DIFFERENT. REPAIRED.
- [SDR HEEA084910](https://openairdocs.org/sdr/HEEA084910.md): Gps · malfunctioned · Feb 28, 2003 · N762P · Skrsky S76A · Global Positioning System
  > GPS SYSTEM WON'T ACKNOWLEDGE ARM.
- [SDR HEEA084908](https://openairdocs.org/sdr/HEEA084908.md): Actuator · malfunctioned · Feb 28, 2003 · N762P · Skrsky S76A · Autopilot Main Servo
  > AFCS ACTUATOR KICKING.
- [SDR HEEA084876](https://openairdocs.org/sdr/HEEA084876.md): Tach Generator · malfunctioned · Feb 27, 2003 · N762P · Skrsky S76A · Engine RPM Indicating System
  > NR 1 OVERSPEED GOVERNOR LIGHT OFF AND ENGINE WILL NOT MOTOR.
- [SDR HEEA084177](https://openairdocs.org/sdr/HEEA084177.md): Shaft · sheared · Feb 12, 2003 · N762P · Skrsky S76A · AC Generator-Alternator
  > AC GENERATOR SHAFT SHEARED.
- [SDR HEEA082985](https://openairdocs.org/sdr/HEEA082985.md): Cvr · faulty · Jan 7, 2003 · N762P · Skrsky S76A · Audio/Video Monitoring
  > COCKPIT VOICE RECORDER TEST LIGHT FLASHES ON CONTINUOSLY.
- [SDR HEEA082980](https://openairdocs.org/sdr/HEEA082980.md): Check Valve · damaged · Jan 7, 2003 · N762P · Skrsky S76A · Aircraft Fuel Distribution System
  > NR 1 ENGINE WOULD NOT START IN CROSSFEED AND NR 2 ENGINE WOULD NOT START IN DIRECT FEED. TO BE SENT TO VENDOR FOR REPAIR.
- [SDR HEEA082979](https://openairdocs.org/sdr/HEEA082979.md): Check Valve · damaged · Jan 7, 2003 · N762P · Skrsky S76A · Aircraft Fuel Distribution System
  > NR 1 ENGINE WOULD NOT START ON FIRST START. DAMAGED FUEL DISTRIBUTION CHECK VALVE
- [SDR HEEA082969](https://openairdocs.org/sdr/HEEA082969.md): Indicator · sluggish · Jan 7, 2003 · N762P · Skrsky S76A · Altimeter, Barometric/Encoder
  > ALTIMETER INDICATOR IS SLUGGISH. IN SHOP REPAIR.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N762P' AND deregistration_id = 'N762P-2017-07-18'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N762P-2017-07-18/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.