- [SDR HNAA2016102400332](https://openairdocs.org/sdr/HNAA2016102400332.md): Unknown · odor · Oct 24, 2016 · N815EX · Dhav DHC8102 · Air Distribution System
  > ELECTRICAL ODOR IN COCKPIT. INSPECTED THE WINDSHIELD HEAT WIRING AND INVERTERS FOR DEFECTS. NONE FOUND. GROUND RAN ENGINES WITH BLEEDS ON. NO ODORS NOTED. OK FOR SERVICE.
- [SDR HNAA2016051900147](https://openairdocs.org/sdr/HNAA2016051900147.md): Wire · chafed · May 18, 2016 · N815EX · Dhav DHC8102 · Light System Wiring
  > CABIN EMERGENCY LIGHTS FLASH ON AND OFF INTERMITTENTLY AT CRUISE FLIGHT AND WITH PROP HEAT ON. REPAIRED 15 CHAFED WIRES JUST FWD OF NR 2 AC CONTACTOR BOX USING SPLICES AND NEW WIRE REF AMM 20-45-08. GROUND RAN ACFT. AC SYSTEM OPS CHECK GOOD. OK FOR SERVIC
- [SDR HNAA2016050900141](https://openairdocs.org/sdr/HNAA2016050900141.md): Relay · malfunctioned · May 8, 2016 · N815EX · Dhav DHC8102 · Propeller/Rotor Anti-Ice/De-Ice System
  > FOLLOW UP CABIN EMERGENCY LIGHTS STARTED TO FLICKER WHEN PROP HEAT SELECTED. CYCLED PROP HEAT OFF AND LIGHTS STOPED. TURNED HEAT BACK ON AND EMERGENCY LIGHTS DID NOT COME BACK ON DUE TO EXTENSIVE HISTORY REQUIRES FURTHER TROUBLESHOOTING. R & R RELAYS 2431-K18
- [SDR HNAA2016050900140](https://openairdocs.org/sdr/HNAA2016050900140.md): Brush Block · dirty · May 8, 2016 · N815EX · Dhav DHC8102 · Propeller/Rotor Anti-Ice/De-Ice System
  > CABIN EMERGENCY LIGHTS STARTED TO FLICKER WHEN PROP HEAT SELECTED. CYCLED PROP HEAT OFF AND LIGHTS STOPED. TURNED HEAT BACK ON AND EMERGENCY LIGHTS DID NOT COME BACK ON INSPECTED AND CLEANED BOTH PROP BRUSH BLOCK ASSEMBLIES AS REQUIRED. NO DEFECTS FOUND AT TH
- [SDR HNAA2016031600080](https://openairdocs.org/sdr/HNAA2016031600080.md): Relay · malfunctioned · Mar 16, 2016 · N815EX · Dhav DHC8102 · Propeller/Rotor Anti-Ice/De-Ice System
  > DURING CLIMB, EMERGENCY LIGHTS FLICKERING WITH PROPS AT 1050. R & R RELAYS 2821 K1 AND K2. RAN AIRCRAFT AUXILIARY FUEL PUMPS AND PROP HEAT. EMERGENCY LIGHTS, OPS CHECKED GOOD.
- [SDR HNAA2016031400078](https://openairdocs.org/sdr/HNAA2016031400078.md): Brush Block · dirty · Mar 14, 2016 · N815EX · Dhav DHC8102 · Windshield/Door Rain/Ice Removal
  > EMERGENCY LIGHTS FLASHED 5 TIMES DURING CLIMBOUT. CLEANED AND INSPECTED NR 1 AND NO. 2 BRUSH BLOCK. NO DEFECTS NOTED. GROUND RAN ACFT. OPS CHECK GOOD. OK FOR SERVICE.
- [SDR HNAA2016031400077](https://openairdocs.org/sdr/HNAA2016031400077.md): Control Box · malfunctioned · Mar 14, 2016 · N815EX · Dhav DHC8102 · Emergency Lighting
  > WHEN NR 2 PROP HEAT A PHASE ILLUMINATES, EMERGENCY LIGHTS ACTIVATE. INSPECTED NR 2 PROP LEADS. NO DEFECTS NOTED. R & R EMERGENCY LIGHTS CONTROL BOX. OPS CHECK GOOD IAW 33-51-00. ACFT OK FOR SERVICE.
- [SDR HNAA2016030900073](https://openairdocs.org/sdr/HNAA2016030900073.md): Lead · chafed · Mar 9, 2016 · N815EX · Dhav DHC8102 · Ice/Rain Protection System Wiring
  > EMERGENCY LIGHTS FLICKERING WITH PROP HEAT SELECTED ON. FOUND CHAFED PROP LEAD AT LEFT, PROP NR 2 BLADE. R & R PROP LEAD. OPS CHECK OK AT THIS TIME.
- [SDR HNAA2016022900063](https://openairdocs.org/sdr/HNAA2016022900063.md): Switch · inoperative · Feb 26, 2016 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHTING SWITCH BACK LIGHT INOPERATIVE WHEN ON, YELLOW, IS SELECTED. R & R EMERGENCY LIGHT SWITCH.
- [SDR HNAA2016022600056](https://openairdocs.org/sdr/HNAA2016022600056.md): Brush Block · shorted · Feb 26, 2016 · N815EX · Dhav DHC8102 · Windshield/Door Rain/Ice Removal
  > EMERGENCY LIGHTS FLICKERED WITH PROP SPEED AT 1050 AND PROP TIMER ON THE RT "A" PHASE. R & R BRUSH BLOCK IAW MM 61-10-11. OPS CHECKED GOOD. OK FOR SERVICE.
- [SDR HNAA2015012500020](https://openairdocs.org/sdr/HNAA2015012500020.md): Bulb · inoperative · Jan 25, 2016 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY FLOOR LIGHT IS INOPERATIVE AT ROW 1. R & R BULB AT ROW 1 EMERGENCY FLOOR LIGHT. OPS CHECKED GOOD.
- [SDR HNAA2016011500007](https://openairdocs.org/sdr/HNAA2016011500007.md): Brush Block · dirty · Jan 15, 2016 · N815EX · Dhav DHC8102 · Propeller/Rotor Anti-Ice/De-Ice System
  > CABIN EMERGENCY LIGHTS FLICKERED IN FLIGHT WITH PROP DE-ICE SELECTED. INSPECTED AND CLEANED BRUSH BLOCKS ASSY ON NR 1 AND NR 2 ENGINES. R & R EMERGENCY CONTROL BOX. RAN ACFT AND CHECKED PROP HEAT. NO DISCREPANCIES NOTED. OK FOR SERVICE.
- [SDR HNAA2016010400003](https://openairdocs.org/sdr/HNAA2016010400003.md): Lamp · burned out · Jan 4, 2016 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY EXIT SIGN ON LOWER FWD OF PAX DOOR HAS INOPERATIVE LAMP. R & R LAMP AND REINSTALLED LENS COVER.
- [SDR HNAA2016010400000](https://openairdocs.org/sdr/HNAA2016010400000.md): Brush Block · contaminated · Jan 4, 2016 · N815EX · Dhav DHC8102 · Propeller/Rotor Anti-Ice/De-Ice System
  > FLOOR EMERGENCY LIGHTS FLICKER INTERMITTENTLY WITH PROP HEAT ON. INSPECTED 1 AND 2 PROP BRUSH BLOCKS, FOUND TO BE WET WITH DEICE FLUID. CLEANED AS REQUIRED. NO DEFECTS FOUND AT THIS TIME. GROUND RAN BOTH ENGINES FOR 25 MINUTES, OPS NORMAL IAW RUNUP MANUAL, O
- [SDR HNAA2015122800374](https://openairdocs.org/sdr/HNAA2015122800374.md): Computer · out of adjust · Dec 28, 2015 · N815EX · Dhav DHC8102 · Stall Warning System
  > UNCOMMANDED STICK SHAKERS ON DURING ROTATION. RETURNED TO FIELD. SHAKERS STOPPED WHEN ACFT ON THE GROUND. FOUND NR 1 STALL WARNING COMPUTER SLIGHTLY OUT OF ADJUSTMENT. CALIBRATED NR 1 AND NR 2 STALL WARNING COMPUTER. OPS AND FUNCTION CHECKED GOOD IAW MM 2
- [SDR HNAA2015122100369](https://openairdocs.org/sdr/HNAA2015122100369.md): Brush Block · shorted · Dec 21, 2015 · N815EX · Dhav DHC8102 · Propeller/Rotor Anti-Ice/De-Ice System
  > EMERGENCY LIGHTS FLICKERED AND CYCLED ON/OFF WITH PROP HEAT ON AND PROPS AT 1050. GOOD WITH PROP HEAT OFF. INSPECTED NR 2 PROP, A PHASE SLIP RINGS AND LEADS. NO DEFECTS NOTED. R & R NR 2 BRUSH BLOCK. GROUND RAN. OPS CHECKED NORMAL AT THIS TIME.
- [SDR HNAA2015110400322](https://openairdocs.org/sdr/HNAA2015110400322.md): Battery · unknown · Nov 4, 2015 · N815EX · Dhav DHC8102 · Battery/Charger System
  > AUXILIARY BATTERY HOT WARNING LIGHTS IN FLIGHT. AUXILIARY BATTERY TEMP IS 65 DEGREES. COMPLIED WITH CHECKLIST. R & R AUX BATTERY IAW MM 24-32-00. OPS CHECKED GOOD.
- [SDR HNAA2015082800266](https://openairdocs.org/sdr/HNAA2015082800266.md): Firewall · chafed · Aug 28, 2015 · N815EX · Dhav DHC8102 · Nacelle/Pylon, Bulkhead/Firewall
  > NR 1 NACELLE, INBD Z MEMBER HAS CRACK IN LIP AT ABOUT 4" ABOVE START OF LIP IN FIREWALL WEB CHAFE. RIMMED FIREWALL PLATE IAW RD8-54-991. REPAIRED CHAFE AND TRIMMED OUT AREA IAW EO8-54-15-0176.
- [SDR HNAA2015031600101](https://openairdocs.org/sdr/HNAA2015031600101.md): None · none · Mar 16, 2015 · N815EX · Dhav DHC8102 · Standard Practices/Structures
  > POSSIBLE ANIMAL STRIKE DURING ROLL OUT. INSPECTED PLANE AND FOUND NO EVIDENCE OF ANIMAL STRIKE.
- [SDR HNAA2015030400074](https://openairdocs.org/sdr/HNAA2015030400074.md): Bulb · inoperative · Mar 4, 2015 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY FLOOR PATH LIGHTS ARE INOPERATIVE AT ROWS 1, 3 AND 7. R & R BULBS FOR EMERGENCY FLOOR PATH LIGHT. OPS CHECKED GOOD.
- [SDR HNAA2015022000057](https://openairdocs.org/sdr/HNAA2015022000057.md): Battery · inoperative · Feb 20, 2015 · N815EX · Dhav DHC8102 · Emergency Lighting
  > CEILING EMERGENCY LIGHT AT ROW 3 IS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY IN ROW 3 CEILING LIGHT. OPS CHECKED GOOD.
- [SDR HNAA2015022000056](https://openairdocs.org/sdr/HNAA2015022000056.md): Battery · inoperative · Feb 20, 2015 · N815EX · Dhav DHC8102 · Emergency Lighting
  > LEFT AFT FUSELAGE EMERGENCY LIGHT IS INOPERATIVE. R & R POWER SUPPLY 3351, PS3 IAW MM 33-51-00.
- [SDR HNAA2015020200029](https://openairdocs.org/sdr/HNAA2015020200029.md): Lamp · inoperative · Jan 30, 2015 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHTS SWITCH NORMAL GREEN LIGHT INOPERATIVE. R & R LAMP, OPS CHECKED GOOD.
- [SDR HNAA2015012800028](https://openairdocs.org/sdr/HNAA2015012800028.md): Bulb · inoperative · Jan 28, 2015 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHT IS INOPERATIVE AT ROW 1. R & R THE BULB. OPS CHECKED GOOD.
- [SDR HNAA2015012800027](https://openairdocs.org/sdr/HNAA2015012800027.md): Bulb · inoperative · Jan 28, 2015 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.
- [SDR HNAA2014122900383](https://openairdocs.org/sdr/HNAA2014122900383.md): Bulb · inoperative · Dec 29, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > 9TH EMERGENCY LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.
- [SDR HNAA2014120800353](https://openairdocs.org/sdr/HNAA2014120800353.md): Warning Horn · false activation · Dec 8, 2014 · N815EX · Dhav DHC8102 · Central Warning
  > DURING POWER UP FOR TAKEOFF AT 65 PERCENT TORQUE, TAKEOFF WARNING HORN SOUNDED. REJECTED TAKEOFF. CLEANED AND INSPECTED FLAP INDICATOR CONNECTOR. NO DEFECTS NOTED. CREW GROUND RAN ACFT AND INSPECTED SYS IAW MM 31-51-00. HORN STILL SOUNDED DURING POWER RUN
- [SDR HNAA2014120800352](https://openairdocs.org/sdr/HNAA2014120800352.md): Indicator · malfunctioned · Dec 8, 2014 · N815EX · Dhav DHC8102 · Trailing Flap Position Indicating System
  > DURING TAKEOFF ROLL, TAKEOFF WARNING HORN SOUNDED. ABORTED TAKEOFF. CYCLED FLAPS, ELEVATOR TRIM AND ECU MODE SWITCHES. GROUND RUN ACFT, HORN DID NOT SOUND. CONFIRMED FLAP INDICATOR CAUSING TAKEOFF WARNING WHILE IN PROPER CONFIGURATION. R & R FLAP INDICATO
- [SDR HNAA2014111200317](https://openairdocs.org/sdr/HNAA2014111200317.md): Bulb · inoperative · Nov 12, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHTS ARE INOPERATIVE AT ROWS 3, 4 AND 6. R & R THE BULBS. OPS CHECKED GOOD.
- [SDR HNAA2014111200316](https://openairdocs.org/sdr/HNAA2014111200316.md): Bulb · inoperative · Nov 12, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > LEFT AFT EXTERIOR EMERGENCY LIGHT IS INOPERATIVE. R & R THE BULB. OPS CHECKED GOOD.
- [SDR HNAA2014102200296](https://openairdocs.org/sdr/HNAA2014102200296.md): Light · no test · Oct 21, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > RIGHT FORWARD EMERGENCY EXIT LIGHT FAILED COMPARATOR CHECK. R & R THE LIGHT ASSY.
- [SDR HNAA2014102200295](https://openairdocs.org/sdr/HNAA2014102200295.md): Bulb · burned out · Oct 21, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > THE 6TH EMERGENCY FLOOR PATH LIGHT BETWEEN ROWS 1 AND 2 IS INOPERATIVE. REPLACED BULB, OPS CHECKED GOOD.
- [SDR HNAA2014092200270](https://openairdocs.org/sdr/HNAA2014092200270.md): Bulb · inoperative · Sep 22, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > CEILING EMERGENCY LIGHT IS INOPERATIVE AT ROW 3. R & R LIGHT BULB FOR CEILING EMERGENCY PATH LIGHT, OPS CHECKED GOOD.
- [SDR HNAA2014091900264](https://openairdocs.org/sdr/HNAA2014091900264.md): Bulb · inoperative · Sep 19, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > RT AFT EMERGENCY EGRESS LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.
- [SDR HNAA2014090500257](https://openairdocs.org/sdr/HNAA2014090500257.md): Bulb · inoperative · Sep 5, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHTS ARE INOPERATIVE AT ROWS 4 AND 8. R & R BULBS IAW MM 33-51-11. OPS CHECKED GOOD.
- [SDR HNAA2014073000217](https://openairdocs.org/sdr/HNAA2014073000217.md): Generator · failed · Jul 30, 2014 · N815EX · Dhav DHC8102 · AC Generator-Alternator
  > NR 1 AC GENERATOR CAUTION LIGHT ILLUMINATED AND WILL NOT RESET. R & R NR 1 AC GENEREATOR AND GCU IAW WC 24-20-11R AND MM 24-21-02. OPS AND LEAK CHECKED GOOD.
- [SDR HNAA2014061800184](https://openairdocs.org/sdr/HNAA2014061800184.md): Knob · unsecure · Jun 18, 2014 · N815EX · Dhav DHC8102 · Communications System
  > FIRST OFFICER`S TRANSMIT SELECT KNOB ON ACP LOOSE. SECURED SELECT KNOB. OPS CHECKED GOOD. OK FOR SERVICE.
- [SDR HNAA2014052100160](https://openairdocs.org/sdr/HNAA2014052100160.md): Bulb · weak · May 21, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > LEFT AFT EXTERNAL FUSELAGE EMERGENCY LIGHT IS DIM. R & R BULB, OPS CHECKED GOOD.
- [SDR HNAA2014050500149](https://openairdocs.org/sdr/HNAA2014050500149.md): Light · missing · May 5, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > RED FLOOR EMERGENCY LIGHT MISSING. INSTALLED RED FLOOR LIGHT MODULE. OPS CHECKED GOOD. OK FOR SERVICE.
- [SDR HNAA2014042100135](https://openairdocs.org/sdr/HNAA2014042100135.md): Bulb · dim · Apr 21, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY CEILING LIGHT DIM AT ROW 1AND 3. R & R EMERGENCY EMERGENCY CEILING LIGHT BULBS AT ROW 1 AND 3. OPS CHECKED GOOD.
- [SDR HNAA2014012300018](https://openairdocs.org/sdr/HNAA2014012300018.md): Bulb · inoperative · Jan 23, 2014 · N815EX · Dhav DHC8102 · Emergency Lighting
  > CEILING EMERGENCY LIGHT IS INOPERATIVE AT ROW 9. R & R BULB. OPS CHECKED GOOD.
- [SDR HNAA2013123100648](https://openairdocs.org/sdr/HNAA2013123100648.md): Flange · cracked · Dec 31, 2013 · N815EX · Dhav DHC8102 · Nacelle/Pylon, Main Frame
  > LEFT NACELLE COLLAR FLANGE IS CRACKED AT FORWARD END. R & R FORWARD ANGLE ON LT COLLAR IAW AMM 54-40-04, 54-40-06 AND EO8-54-13-0696.
- [SDR HNAA2013102500547](https://openairdocs.org/sdr/HNAA2013102500547.md): Light · inoperative · Oct 25, 2013 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHT IS INOPERATIVE AT ROW 1. R & R EMERGENCY LIGHT IAW AMM 33-51-00. OPS CHECKED GOOD.
- [SDR HNAA2013102500546](https://openairdocs.org/sdr/HNAA2013102500546.md): Bulb · malfunctioned · Oct 25, 2013 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY EXIT DOOR SIGN IS DIM. R & R EXIT SIGN BULBS. OPS CHECKED GOOD IAW AMM 33-51-00.
- [SDR HNAA2013102100542](https://openairdocs.org/sdr/HNAA2013102100542.md): Bulb · inoperative · Oct 21, 2013 · N815EX · Dhav DHC8102 · Emergency Lighting
  > EMERGENCY LIGHT INOPERATIVE AT ROWS 1 AND 3. R & R BULBS, OPS CHECKED GOOD.
- [SDR HNAA2013102100539](https://openairdocs.org/sdr/HNAA2013102100539.md): Unknown · odor · Oct 21, 2013 · N815EX · Dhav DHC8102 · Air Distribution System
  > ON APU BLEED START, STRONG FUEL ODOR ENTERED CABIN. NO LEAKS FOUND OR OBVIOUS DEFECTS. GROUND RAN ACFT WITH DOORS OPEN FOR 10 MINUTES AND CABIN ODOR CLEARED AT THIS TIME,
- [SDR HNAA2013082600475](https://openairdocs.org/sdr/HNAA2013082600475.md): Unknown · odor · Aug 26, 2013 · N815EX · Dhav DHC8102 · Passenger Compartment Lighting
  > ELECTRICAL BURNING ODOR APPEARS TO BE COMING FROM OVERHEAD LIGHTS AT ROW 7DF. R & R LAMP HOLDER, BULB AND BALLAST. OPS CHECKED GOOD.
- [SDR HNAA2013061200333](https://openairdocs.org/sdr/HNAA2013061200333.md): Ahrs · failed · Jun 12, 2013 · N815EX · Dhav DHC8102 · Attitude and Direction Data System
  > NR 2 AHRS FAILED. NR 2 ADI READ 10 DEGREES PITCH OP. CYCLED NR 2 AHRS, CIRCUIT BREAKER ADI CORRECTED PITCH. R & R ARHU. OPS CHECKED GOOD IAW 34-20-06.
- [SDR HNAA2013052900314](https://openairdocs.org/sdr/HNAA2013052900314.md): Light · inoperative · May 29, 2013 · N815EX · Dhav DHC8102 · Emergency Lighting
  > TWO RED FLOOR EMERGENCY LIGHTS ARE INOPERATIVE. R & R ONE LAMP AND ONE LIGHT SOCKET AT ROW 1. OPS CHECKED GOOD.
- [SDR HNAA2013050300250](https://openairdocs.org/sdr/HNAA2013050300250.md): Bulb · failed · May 3, 2013 · N815EX · Dhav DHC8102 · Emergency Lighting
  > LEFT AFT FUSELAGE EMERGENCY LIGHT IS INOPERATIVE. R & R BULB IAW AMM 33-51-00.

Next page: https://openairdocs.org/deregistered/N815EX-2022-02-14/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N815EX' AND deregistration_id = 'N815EX-2022-02-14'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N815EX-2022-02-14/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.