# Service difficulty reports: N838CA, cancelled Nov 12, 2020

A list on [N838CA, cancelled Nov 12, 2020](https://openairdocs.org/deregistered/N838CA-2020-11-12.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Page 1 of 2 · 58 reports

- [SDR JJBA20170322013](https://openairdocs.org/sdr/JJBA20170322013.md): Window · detached · Mar 22, 2017 · N838CA · Dhav DHC8311 · Flight Compartment Windows
  > EMERGENCY EXIT WINDOW FELL OUT. REINSTALLED THE ANGLE TO INNER WINDOW. INSTALLED THE WINDOW. OPS CHECKED GOOD.
- [SDR JJBA20170310008](https://openairdocs.org/sdr/JJBA20170310008.md): Connector · defective · Mar 10, 2017 · N838CA · Dhav DHC8311 · Light System Wiring
  > SMOKE OBSERVED AT 1CD OVERHEAD LIGHT AND LIGHTS EXTINGUISHED. REPLACED DEFECTIVE CONNECTOR BS2-P2/J2.
- [SDR JJBA20170117014](https://openairdocs.org/sdr/JJBA20170117014.md): Smoke Detector · false activation · Jan 17, 2017 · N838CA · Dhav DHC8311 · Smoke Detection
  > LAVATORY SMOKE DETECTOR SOUNDED IN FLIGHT. R & R THE SMOKE DETECTOR.
- [SDR JJBA20161202007](https://openairdocs.org/sdr/JJBA20161202007.md): Fire Loop · failed · Dec 2, 2016 · N838CA · Dhav DHC8311 · Fire Detection
  > CREW RECEIVED MASTER WARNING AND CHECK FIRE DETECTOR LIGHTS. RAN CHECKLIST AND DISCOVERED LOOP A ON THE NR 1 ENGINE FAULTED. R & R THE FIRE LOOP A. OPS CHECKED GOOD. NO OTHER DEFECTS NOTED.
- [SDR JJBA20160805005](https://openairdocs.org/sdr/JJBA20160805005.md): Battery · discharged · Aug 5, 2016 · N838CA · Dhav DHC8311 · Emergency Lighting
  > EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT BATTERIES, OPS CK SATISFACTORY, ADDITIONAL PN 61-0478-11, OFF: SN:9801269, TT:28739.27, TC:37849, CMA0006, TT:13542.33, TC:16061/ H096, TT:34211.33, TC:37303.
- [SDR JJBA20160719009](https://openairdocs.org/sdr/JJBA20160719009.md): Sign · inoperative · Jul 19, 2016 · N838CA · Dhav DHC8311 · Emergency Lighting
  > EMERGENCY EXIT SIGN AT ROW 2 IS INOPERATIVE. R & R THE SIGN. OPS CHECKED GOOD.
- [SDR JJBA20160531001](https://openairdocs.org/sdr/JJBA20160531001.md): Smoke Detector · inoperative · May 31, 2016 · N838CA · Dhav DHC8311 · Smoke Detection
  > WHEN POWER APPLIED, LAVATORY SMOKE ALARM KEEPS BEEPING. R & R LAVATORY SMOKE DETECTOR.
- [SDR JJBA20160511007](https://openairdocs.org/sdr/JJBA20160511007.md): Power Supply · inoperative · May 11, 2016 · N838CA · Dhav DHC8311 · Emergency Lighting
  > CEILING EMER LIGHTS INOPERATIVE AT 2 & 3. R & R PS2 POWER SUPPLY.
- [SDR JJBA20160510006](https://openairdocs.org/sdr/JJBA20160510006.md): Relay · failed · May 10, 2016 · N838CA · Dhav DHC8311 · Passenger Compartment Lighting
  > ALL OVERHEAD LIGHTS ON THE RT SIDE OF THE CABIN DO NOT ILLUMINATE. SMOKE WAS REPORTED BY THE FLIGHT CREW & MX PERSONNEL. FOUND WIRES & ELEC EQUIP TO BE BURNT. FOUND 3326BS2J2 P2 CONNECTOR BURNED. R & R PLUS & RELAY PN DSC157-1.
- [SDR JJBA20160507004](https://openairdocs.org/sdr/JJBA20160507004.md): Battery · discharged · May 7, 2016 · N838CA · Dhav DHC8311 · Emergency Lighting
  > OVERHEAD EMER EXIT SIGN INOPERATIVE AT 3 & 7. R & R EMER BATTERIES AT POSITION PS3 & PS4.
- [SDR JJBA20160507003](https://openairdocs.org/sdr/JJBA20160507003.md): Light · inoperative · May 7, 2016 · N838CA · Dhav DCH1CHIPMUNK · Emergency Lighting
  > SEAT 18D UNDERWING EMER EXIT LIGHT WILL NOT ILLUMINATE. R & R EMER LIGHT ASSEMBLY.
- [SDR JJBA20160501001](https://openairdocs.org/sdr/JJBA20160501001.md): Unknown · malfunctioned · May 1, 2016 · N838CA · Dhav DHC8311 · Emergency Lighting
  > EMERGENCY LIGHTS FAILED TO ARM ON FIRST TRY. PERFORMED SYS RESET & TESTED SATISFACTORY.
- [SDR JJBA20160428017](https://openairdocs.org/sdr/JJBA20160428017.md): Power Supply · inoperative · Apr 28, 2016 · N838CA · Dhav DHC8311 · Emergency Lighting
  > TWO CEILING EMER LIGHTS INOPERATIVE IN CEILING & MISSING ONE COVER. R & R EMER LIGHT POWER SUPPLY 3351-PS2. FOUND BROKEN WIRE 3351-17A20-2, SPLICED. ADDITION PART 61-0478-11, SN H106 TSN - 160 CSN - 173.
- [SDR JJBA20160411013](https://openairdocs.org/sdr/JJBA20160411013.md): Plate · buckled · Apr 11, 2016 · N838CA · Dhav DHC8311 · Wing Miscellaneous Structure
  > LADDER PLATE BUCKLED, REPAIRED.
- [SDR JJBA20160218011](https://openairdocs.org/sdr/JJBA20160218011.md): Floorbeam · corroded · Feb 18, 2016 · N838CA · Dhav DHC8311 · Fuselage Main, Floor Beam
  > FORWARD CTR LT FLOORBEAM HAS SIGNS OF CORROSION, STATION X149.0 TO X180.4. R & R FWD COUNTER LT FLOORBEAM.
- [SDR JJBA20150822003](https://openairdocs.org/sdr/JJBA20150822003.md): Connector · disconnected · Aug 22, 2015 · N838CA · Dhav DHC8202 · Fire Protection System Wiring
  > LAVATORY SMOKE DETECTOR WILL NOT TEST. FOUND CONNECTOR LOOSE.
- [SDR JJBA20150701013](https://openairdocs.org/sdr/JJBA20150701013.md): Hydraulic Line · damaged · Jun 30, 2015 · N838CA · Dhav DHC8202 · Hydraulic System, Main
  > AT 100 FT HYD CAUTION LIGHT ILLUMINATED. UPON LANDING THE NOSE WHEEL STEERING FAILED, THEN LOST ALL HYD QTY FROM NR 2 HYD SYS. R & R NLG DOWNLOCK ACTUATOR, DOWN PRESS HOSE, BLEED THE NR 2 HYD SYS.
- [SDR JJBA20150505005](https://openairdocs.org/sdr/JJBA20150505005.md): Engine · shutdown · May 5, 2015 · N838CA · Dhav DHC8311 · Engine (Turbine/Turboprop)
  > NUMBER 2 ENG SHUTDOWN UNCOMMANDED ON TAKEOFF ROLL. R & R NR 2 ENG.
- [SDR JJBA20150329018](https://openairdocs.org/sdr/JJBA20150329018.md): Battery · defective · Mar 29, 2015 · N838CA · Dhav DHC8311 · Emergency Lighting
  > ONE OVERHEAD EMER LIGHT INOPERABLE & THE RT SIDE EMER EXIT LIGHT INOPERABLE. SWAPPED EMER BATTERIES PS1 & PS2.
- [SDR JJBA20150304007](https://openairdocs.org/sdr/JJBA20150304007.md): Ecu · faulty · Mar 4, 2015 · N838CA · Dhav DHC8311 · Fuel Control/Turbine Engines
  > NUMBER 1 ENG DOES NOT PRODUCE MORE THAN 75% TORQUE ON TAKEOFF. R & R NR 1 ECU.
- [SDR JJBA20150216003](https://openairdocs.org/sdr/JJBA20150216003.md): Test Switch · out of alignment · Feb 16, 2015 · N838CA · Dhav DHC8311 · Smoke Detection
  > LAVATORY SMOKE DETECTOR WILL NOT TEST. FOUND TEST BUTTON OUT OF ALIGNMENT, REALIGNED BUTTON.
- [SDR JJBA20140827009](https://openairdocs.org/sdr/JJBA20140827009.md): Connector · not seated · Aug 27, 2014 · N838CA · Dhav DHC8311 · Light System Wiring
  > EMERGENCY LIGHTS DO NOT COME ON. RESEATED PLUG TO FLIGHT ATTENDANT EMER PUSH BUTTON. OPERATIONAL CHECKED SATISFACTORY.
- [SDR JJBA20140718020](https://openairdocs.org/sdr/JJBA20140718020.md): Transmitter · faulty · Jul 18, 2014 · N838CA · Dhav DHC8311 · Engine Oil Pressure
  > NUMBER 2 OIL PRESS FLUX IN FLIGHT 0-35PSI. NO WARNING LIGHT NOTED. R & R NR 2 ENG OIL PRESS TRANSMITTER.
- [SDR JJBA20140708017](https://openairdocs.org/sdr/JJBA20140708017.md): Tire · burst · Jul 8, 2014 · N838CA · Dhav DHC8311 · Tire
  > NUMBER 3 MAIN TIRE BURST ON TAKEOFF. R & R NR 3 & NR 4 MAIN WHEEL ASSEMBLIES.
- [SDR JJBA20140703013](https://openairdocs.org/sdr/JJBA20140703013.md): Wire · loose · Jul 3, 2014 · N838CA · Dhav DHC8311 · Light System Wiring
  > CABIN EMER LIGHTS CAME ON IN FLIGHT. REPAIRED LOOSE WIRE ON FLIGHT ATTENDANT PANEL SWITCH.
- [SDR JJBA20140622011](https://openairdocs.org/sdr/JJBA20140622011.md): Unknown · malfunctioned · Jun 22, 2014 · N838CA · Bombdr DHC8400 · Propeller Indication System
  > NUMBER 2 PROP DID NOT COME OUT OF 900 RPM WHEN CREW TRIED TO INCREASE TO 1200 RPM ON LANDING. GND RAN ACFT, INSPECTED NR 2 ENG PUSHRODS TO PCU & NO DEFECTS FOUND. OCF REQUIRED.
- [SDR JJBA20140515007](https://openairdocs.org/sdr/JJBA20140515007.md): Sign · misinstalled · May 15, 2014 · N838CA · Dhav DHC8311 · Placards and Markings
  > OVERHEAD EXIT SIGN ABOVE ROW 18 BACKWARDS. REMOVED & INSTALLED PROPERLY.
- [SDR JJBA20140327014](https://openairdocs.org/sdr/JJBA20140327014.md): Pcu · malfunctioned · Mar 27, 2014 · N838CA · Dhav DHC8311 · Propeller Controlling System
  > CONDITION LEVER AT MAX, POWER LEVER BROUGHT TO FLIGHT IDLE, THE NR 1 RPM DROPPED FROM 789 TO 650 THEN WENT BACK UP. R & R NR 1 PCU.
- [SDR JJBA20140327013](https://openairdocs.org/sdr/JJBA20140327013.md): Unknown · malfunctioned · Mar 27, 2014 · N838CA · Dhav DHC8311 · Propeller Feathering/Reversing
  > NR 1 ENG PROP WENT TO FEATHER BY ITSELF WHEN THE POWER LEVER WAS MOVED FROM DISC TO FLIGHT IDLE. INSPECTED RIGGING, OPERATIONAL CHECKED NORMAL. OCF REQUIRED & FAILED.
- [SDR JJBA20140324012](https://openairdocs.org/sdr/JJBA20140324012.md): Pump · malfunctioned · Mar 24, 2014 · N838CA · Dhav DHC8311 · Engine Fuel Pump
  > ON CLIMB OUT NR 1 ENG TORQUE SURGED BETWEEN 70 & 100% THEN SHUT DOWN. R & R NR 1 HP FUEL PUMP & MFC. R & R NR 1 TSCU.
- [SDR JJBA20140320011](https://openairdocs.org/sdr/JJBA20140320011.md): Battery · discharged · Mar 20, 2014 · N838CA · Dhav DHC8311 · Emergency Lighting
  > EMERGENCY LIGHTS WILL NOT TEST OR TURN ON. R & R ALL SIX BATTERIES.
- [SDR JJBA20140311006](https://openairdocs.org/sdr/JJBA20140311006.md): Indicator · faulty · Mar 11, 2014 · N838CA · Dhav DHC8311 · Engine Oil Pressure
  > NUMBER 1 ENG OIL PRESS STUCK AT 70 PSI. REMOVED WASHER FROM OIL PRESS REGULATOR. OPERATIONAL CHECK FAILED. R & R NR 1 OIL PRESS GAUGE.
- [SDR JJBA20140223011](https://openairdocs.org/sdr/JJBA20140223011.md): Placard · missing · Feb 23, 2014 · N838CA · Dhav DHC8311 · Placards and Markings
  > EMERGENCY EXIT LIGHT AT SEAT 18A PLACARD MISSING. FOUND & RE-INSTALLED PLACARD.
- [SDR JJBA20140222010](https://openairdocs.org/sdr/JJBA20140222010.md): Battery · discharged · Feb 22, 2014 · N838CA · Dhav DHC8311 · Emergency Lighting
  > EMERGENCY LIGHTS INOPERABLE. R & R ALL EMERGENCY BATTERIES.
- [SDR JJBA20140218009](https://openairdocs.org/sdr/JJBA20140218009.md): Sign · inoperative · Feb 18, 2014 · N838CA · Dhav DHC8311 · Emergency Lighting
  > LEFT HAND EMERGENCY EXIT DOOR BOTTOM HORIZONTAL EXIT SIGN MULTIPLE LIGHTS INOPERABLE. R & R EXIT SIGN IRW DASH 300 20-45-07.
- [SDR JJBA20131224005](https://openairdocs.org/sdr/JJBA20131224005.md): Light · missing · Dec 24, 2013 · N838CA · Dhav DHC8311 · Emergency Lighting
  > FILTER MISSING IAW LT CABIN LOWER EMERGENCY PLACARD LIGHT. REMOVED LT LOWER CABIN EMERGENCY EXIT LIGHT & SPLICED IN NEW EXIT LIGHT ASSEMBLY IRW DH8 Q300 20-45-07.
- [SDR JJBA20131117008](https://openairdocs.org/sdr/JJBA20131117008.md): Irs · malfunctioned · Nov 17, 2013 · N838CA · Dhav DHC8311 · Standard Practices/Structures
  > IRS ALIGN LIGHT INOPERATIVE. R & R IRS CONTROL. OPS CHECKED GOOD.
- [SDR JJBA20130822012](https://openairdocs.org/sdr/JJBA20130822012.md): Switch · failed · Aug 22, 2013 · N838CA · Dhav DHC8311 · Cabin Cooling System
  > CABIN PACK HOT LIGHT ILLUMINATED IN FLIGHT. R & R OVERTEMP SWITCH ON CABIN ACM. OPS CHECKED SATISFACTORY.
- [SDR JJBA20130703005](https://openairdocs.org/sdr/JJBA20130703005.md): Connector · loose · Jul 3, 2013 · N838CA · Dhav DHC8311 · Light System Wiring
  > FORWARD CEILING EMERGENCY LIGHTS INOPERATIVE. MX SECURED CONNECTOR IAW AMM, OPS CHECKED SATISFACTORY.
- [SDR JJBA20130602022](https://openairdocs.org/sdr/JJBA20130602022.md): Battery Pack · discharged · Jun 2, 2013 · N838CA · Dhav DHC8311 · Emergency Lighting
  > CREW REPORTED THAT 1 EMERGENCY FLOOR LIGHT WAS INOPERATIVE. THE BATTERIES WERE ALLOWED TO CHARGE AND ALL OPERATIONAL TEST WERE SATISFACTORY.
- [SDR JJBA20130424012](https://openairdocs.org/sdr/JJBA20130424012.md): Light · inoperative · Apr 24, 2013 · N838CA · Dhav DHC8202 · Emergency Lighting
  > CREW REPORTED THAT THE ROW 1 AFT RED EMERGENCY FLOOR PATH LIGHT WAS INOPERATIVE. MX REPLACED THE EMERGENCY LIGHT STRIP.
- [SDR JJBA20130410004](https://openairdocs.org/sdr/JJBA20130410004.md): Unknown · smoke · Apr 10, 2013 · N838CA · Dhav DHC8311 · Air Distribution System
  > CREW REPORTED THAT DURING TAXI SMOKE WAS DETECTED IN THE CABIN. GROUND MX CREW RAN BOTH ENGINES INDEPENDENTLY AND TOGETHER WITH INDEPENDENT ACM'S FOR OVER 40 MINUTES WITH NO SMOKE OR ANY OTHER ISSUE.
- [SDR JJBA201303060001](https://openairdocs.org/sdr/JJBA201303060001.md): Acm · inoperative · Mar 6, 2013 · N838CA · Dhav DHC8311 · Cabin Cooling System
  > CREW REPORTED A "BURNING DUST" ODOR DURING TAKEOFF THAT DISSIPATED WHEN THE CABIN HEAT WAS TURNED DOWN. AFTER TAKEOFF, CREW OBSERVED A STRONG MELTING PLASTIC ODOR IN THE COCKPIT AND CABIN. THE CREW RETURNED TO FIELD AND DECLARED AN EMERGENCY. ACFT LANDED W
- [SDR JJBA20130106002](https://openairdocs.org/sdr/JJBA20130106002.md): Connector · unsecure · Jan 6, 2013 · N838CA · Dhav DHC8311 · Light System Wiring
  > DURING PRE-FLIGHT INSPECTION, CREW NOTICED A SECTION OF THE FLOOR EMERGENCY LIGHTING WAS NOT ILLUMINATING. MX DISCONNECTED AND RECONNECTED THE CONNECTOR FOR THE LIGHT STRIP. ALL OPS CHECKS PRODUCED SATISFACTORY RESULTS AND THE ACFT WAS RETURNED TO SERVICE.
- [SDR JJBA20121124008](https://openairdocs.org/sdr/JJBA20121124008.md): Fuel Filter · warning light · Nov 24, 2012 · N838CA · Dhav DHC8311 · Engine Fuel Distribution
  > CREW REPORTED THAT THE NR 2 FUEL FILTER BYPASS LIGHT ILLUMINATED IN FLIGHT. CREW DECLARED AN EMERGENCY DUE TO COMMUNICATION ISSUES IN COMBINATION WITH THE BYPASS LIGHT. ACFT FINISHED OUT THE FLIGHT WITHOUT FURTHER INCIDENT. GROUND MX CREW R & R THE HP FUEL
- [SDR JJBA20120704003](https://openairdocs.org/sdr/JJBA20120704003.md): Battery Pack · discharged · Jul 4, 2012 · N838CA · Dhav DHC8301 · Emergency Lighting
  > DURING PRE-FLIGHT, CREW NOTICED SEVERAL EMERGENCY LIGHTS WERE INOPERATIVE. MX RECHARGED THE EMERGENCY LIGHT BATTERIES. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AFTER BATTERIES HAD CHARGED. THE ACFT WAS RELEASED TO SERVICE.
- [SDR JJBA20120418005](https://openairdocs.org/sdr/JJBA20120418005.md): Acm · smoke · Apr 18, 2012 · N838CA · Dhav DHC8311 · Cabin Cooling System
  > DURING TAXI, NOTICED APPEARANCE OF SMOKE IN COCKPIT. RETURNED TO GATE. INSPECTED AND FOUNG NR 2 ACM CAUSING THE SMOKE. OPEN
- [SDR JJBA20110919001A](https://openairdocs.org/sdr/JJBA20110919001A.md): Connector · damaged · Sep 19, 2011 · N838CA · Dhav DHC8202 · Fire Protection System Wiring
  > FLIGHT CREW REPORTED THAT THE BAGGAGE SMOKE DETECTOR WARNING ILLUMINATED IN FLIGHT. MX R & R A BROKEN PIN ON THE CONNECTOR PLUG. PERFORMED OPS CHECK SATISFACTORY.
- [SDR JJBA20110909001](https://openairdocs.org/sdr/JJBA20110909001.md): Smoke Detector · false indication · Sep 9, 2011 · N838CA · Dhav DHC8311 · Smoke Detection
  > FLIGHT CREW REPORTED SMOKE WARNING LIGHT ILLUMINATED IN FLIGHT. MX R & R THE NR 2 SMOKE DETECTOR, PERFORMED OPS CHECK SATISFACTORY.
- [SDR JJBA20110908001](https://openairdocs.org/sdr/JJBA20110908001.md): Battery Pack · discharged · Sep 8, 2011 · N838CA · Dhav DHC8311 · Emergency Lighting
  > FLIGHT CREW REPORTED THAT THERE ARE A FEW EMERGENCY LIGHTS THAT DO NOT TEST. MX CREW ALLOWED BATTERIES TO RECHARGE AND PERFORMED OPS CHECK WITH NO DEFECTS NOTED.

Next page: https://openairdocs.org/deregistered/N838CA-2020-11-12/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N838CA' AND deregistration_id = 'N838CA-2020-11-12'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N838CA-2020-11-12/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.