- [SDR FDKA2010063000166](https://openairdocs.org/sdr/FDKA2010063000166.md): Seal · lack of lube · Jun 30, 2010 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > MAIN CABIN DOOR SQUEALS IN FLT. MX REPAIRED AND LUBED DOOR SEAL, OP AND PRESS CHECKS GOOD.
- [SDR FDKA2010062800164](https://openairdocs.org/sdr/FDKA2010062800164.md): Smoke Goggles · cracked · Jun 28, 2010 · N857MJ · Emb EMB145LR · Emergency Equipment
  > OBS SMOKE GOGGLES CRACKED. MX REMOVED AND REPLACED OBS SMOKE GOGGLES.
- [SDR FDKA2010061900152](https://openairdocs.org/sdr/FDKA2010061900152.md): Electrical Sys · malfunctioned · Jun 19, 2010 · N857MJ · Emb EMB145LR · DC Power Distribution System
  > ELECT EMERGENCY ABNORMAL IN FLT - RTF. MX PERFORMED ELECTRICAL RESET AND RERACKED 1 AND 2 DAU, OPS GOOD.
- [SDR FDKA2010052300121](https://openairdocs.org/sdr/FDKA2010052300121.md): Skin · cracked · May 23, 2010 · N857MJ · Emb EMB145LR · Fuselage Main, Plate/Skin
  > LT RVSM FILLER PERM REPAIR IN WORK, COMPLY WITH RO EMB145-53-0254. MX C/W RVSM CRACK PERM REPAIR.
- [SDR FDKA2010042000085](https://openairdocs.org/sdr/FDKA2010042000085.md): Track · lack of lube · Apr 20, 2010 · N857MJ · Emb EMB145LR · Flight Compartment Windows
  > CAPT DV WINDOW W/N OPEN. CLEANED AND LUBED TRACK, OPS GOOD.
- [SDR FDKA2010040600065](https://openairdocs.org/sdr/FDKA2010040600065.md): Light · inoperative · Apr 6, 2010 · N857MJ · Emb EMB145LR · Emergency Lighting
  > THE 12A SMALLER EMERGENCY LIGHT INOP. RE-SECURED, OPS CHECK GOOD PER 33-42-01.
- [SDR FDKA2010033000056](https://openairdocs.org/sdr/FDKA2010033000056.md): Roller · dirty · Mar 30, 2010 · N857MJ · Emb EMB145LR · Service Doors
  > SERVICE DOOR WILL NOT OPEN. CLEANED AND LUBED DOOR ROLLERS, OPS GOOD.
- [SDR FDKA2010032300050](https://openairdocs.org/sdr/FDKA2010032300050.md): Seal · lack of lube · Mar 23, 2010 · N857MJ · Emb EMB145LR · Hydraulic System, Main
  > SQUEAL UNDER F/O WITH HYD RUNNING. LUBED SEAL PRESSURE CHECKS AND LEAK CHECKS GOOD.
- [SDR FDKA2010031000039](https://openairdocs.org/sdr/FDKA2010031000039.md): Light · inoperative · Mar 10, 2010 · N857MJ · Emb EMB145LR · Emergency Lighting
  > PAX DOOR OVERHEAD EMERGENCY LIGHT INOP. REMOVED AND REPLACED PAX DOOR OVERHEAD EMERGENCY LIGHT, OPS CHECK GOOD.
- [SDR FDKA2010022500031](https://openairdocs.org/sdr/FDKA2010022500031.md): Door · dirty · Feb 25, 2010 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > MAIN DOOR HARD TO OPEN AND CLOSE. CLEANED AND LUBED, OPS GOOD.
- [SDR FDKA2010011700008](https://openairdocs.org/sdr/FDKA2010011700008.md): Track · dirty · Jan 17, 2010 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > MAIN CABIN DOOR HARD TO OPEN AND CLOSE. CLEAN AND LUBED DOOR TRACKS.
- [SDR FDKA2009121300208](https://openairdocs.org/sdr/FDKA2009121300208.md): Seal · dirty · Dec 13, 2009 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > FLT 6167 XNA-CVG. MAIN DOOR DIFFICULT TO OPEN. MX PERFORMED CLEANING AND LUBE OF THE DOOR SEALS.
- [SDR FDKA2009112400200](https://openairdocs.org/sdr/FDKA2009112400200.md): Bolt · broken · Nov 24, 2009 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > FRL FLT 6144 CVG-MCI. MAIN CABIN DOOR HARD TO CLOSE. REPLACED FOUND BROKEN BOLT AT DOOR AFT LOWER ROLLER. OPS GOOD.
- [SDR FDKA2009112200199](https://openairdocs.org/sdr/FDKA2009112200199.md): Roller · dirty · Nov 22, 2009 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > FRL FLT 6120 CVG. MAIN CABIN DOOR HARD TO CLOSE. MX CLEANED AND LUBED DOOR AND ROLLERS. OPS GOOD.
- [SDR FDKA2009112100198](https://openairdocs.org/sdr/FDKA2009112100198.md): Seal · dirty · Nov 21, 2009 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > FRL FLT 6134 CVG-LEX. MAIN CABIN DOOR HARD TO OPEN AND CLOSE. MX CLEANED AND LUBED SEAL, OPS CHECK GOOD.
- [SDR FDKA2009062500136](https://openairdocs.org/sdr/FDKA2009062500136.md): Inverter · inoperative · Jun 25, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6283 CVG. AFT CEILING EMERGENCY EXIT LOCATOR FWD SIDE LIGHT INOPERATIVE. MX REMOVED AND REPLACED NR 6 INVERTER. OPS GOOD.
- [SDR FDKA2009062100132](https://openairdocs.org/sdr/FDKA2009062100132.md): Connector · dirty · Jun 21, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > FRL FLT 6267 ORF TO CVG. AFT CEILING EMERGENCY EXIT LOCATOR FWD SIDE LIGHT OUT. MX CLEANED AND RE-SECURED CONNECTORS, OPS GOOD.
- [SDR FDKA2009061600125](https://openairdocs.org/sdr/FDKA2009061600125.md): Connector · disconnected · Jun 16, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > AFT CEILING EMERGENCY EXIT LOCATOR WILL NOT ILLUMINATE. MX RESECURED LIGHT CONNECTORS OPS GOOD.
- [SDR FDKA2009060600116](https://openairdocs.org/sdr/FDKA2009060600116.md): Light · malfunctioned · Jun 6, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6304 CLE TO CVG - AFT CEILING EMERGENCY EXIT LOCATOR FORWARD SIDE LIGHT NOT ILLUMINATING. MX RESET LIGHT, OPS GOOD.
- [SDR FDKA2009060400115](https://openairdocs.org/sdr/FDKA2009060400115.md): Connector · loose · Jun 4, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > FRL FLT 6264 CLT-CVG. ROW 12 OVERHEAD EMERGENCY EXIT SIGN LIGHT INOP. MX REMOVED, CLEANED AND RESECURED CONNECTOR.
- [SDR FDKA2009060200112](https://openairdocs.org/sdr/FDKA2009060200112.md): Light · inoperative · Jun 2, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6274 PIT. ROW 12 O/H FWD FACE EMERGENCY EXIT SIGN WILL NOT ILLUMINATE. MX RELAMPED.
- [SDR FDKA2009052600106](https://openairdocs.org/sdr/FDKA2009052600106.md): Light · malfunctioned · May 26, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6204 CVG-IAD. ROW 12 OVERHEAD EMERGENCY LIGHT INOP. RESET, OPS CK GOOD.
- [SDR FDKA2009052000103](https://openairdocs.org/sdr/FDKA2009052000103.md): Light · inoperative · May 20, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6193 CVG - AFT CEILING EXIT LOCATOR INOP. MX RESET, OPS NORMAL.
- [SDR FDKA2009051600096](https://openairdocs.org/sdr/FDKA2009051600096.md): Light · inoperative · May 16, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6247 CVG-CLT - ROW 12 LT UPPER EMERGENCY LIGHT INOP. MX RESET.
- [SDR FDKA2009051500095](https://openairdocs.org/sdr/FDKA2009051500095.md): Light · inoperative · May 15, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6212 CVG-RIC - ROW 12 LT UPPER EMERGENCY LIGHT INOP. MX RESET THE SYSTEM, OPS CHECKED GOOD.
- [SDR FDKA2009043000088](https://openairdocs.org/sdr/FDKA2009043000088.md): Connector · loose · Apr 30, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > FRL FLT 6168 ORF-JFK. ROW 12 FWD EMERGENCY LIGHT INOP. MX RE-SECURED CONNECTORS.
- [SDR FDKA2009042500082](https://openairdocs.org/sdr/FDKA2009042500082.md): Light · malfunctioned · Apr 25, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6244 JFK-BDL ROW 12 OVERHEAD EMERGENCY LIGHT INOPERATIVE. MX RESET SYSTEM, OPS CHECKED GOOD.
- [SDR FDKA2009042400080](https://openairdocs.org/sdr/FDKA2009042400080.md): Light · malfunctioned · Apr 24, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6174 JFK. OVERWING EXIT SIGN INOPERATIVE. MX RESET SYSTEM, OPS CHECKED GOOD.
- [SDR FDKA2009040900068](https://openairdocs.org/sdr/FDKA2009040900068.md): Connector · loose · Apr 9, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > FRL FLT 6231 ORF. ROW 12 AISLE EMERGENCY LIGHT INOP. MX RE-SECURED THE CONNECTOR, OPS CHECK GOOD.
- [SDR FDKA2009040500062](https://openairdocs.org/sdr/FDKA2009040500062.md): Connector · loose · Apr 5, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > FRL FLT 6226 CVG. AFT CEILING FWD SIDE EMERGENCY EXIT LOCATOR INOP. MX RE-SECURED LOOSE CONNECTOR, OPS GOOD.
- [SDR FDKA2009033000060](https://openairdocs.org/sdr/FDKA2009033000060.md): Connector · loose · Mar 30, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > FRL FLT 6279 JFK-SYR. OVER AISLE EMERGENCY EXIT SIGN INOP. MX RE-SECURED LIGHT ASSY CONNECTORS, OPS CHECK GOOD.
- [SDR FDKA2009021700034](https://openairdocs.org/sdr/FDKA2009021700034.md): Connector · loose · Feb 17, 2009 · N857MJ · Emb EMB145LR · Light System Wiring
  > FRL FLT 6251 - BDL. ROW 12 OVERHEAD AND LT LOWER EMERGENCY LIGHT INOP. MX RESECURED CONNECTORS.
- [SDR FDKA2009021200030](https://openairdocs.org/sdr/FDKA2009021200030.md): Light · malfunctioned · Feb 12, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FLT 6236 CVG-IAD - ONE OVERHEAD EMER LIGHT INOP. MX CALLED OUT AND PERFORMED OP CHECK, OP NORMAL.
- [SDR FDKA2009011300010](https://openairdocs.org/sdr/FDKA2009011300010.md): Light · malfunctioned · Jan 13, 2009 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6231 JFK-ORF. CENTER CEILING EMERGENCY LIGHT INOP. RESET SYSTEM.
- [SDR FDKA2008122000319](https://openairdocs.org/sdr/FDKA2008122000319.md): Light · malfunctioned · Dec 20, 2008 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6208 CVG-JFK. OVERHEAD EMERG LIGHT ROW 12 INOP. MX RESET SYSTEM, OPS GOOD.
- [SDR FDKA2008121400312](https://openairdocs.org/sdr/FDKA2008121400312.md): Battery · discharged · Dec 14, 2008 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6260 PIT - AC EMERGENCY LIGHTS WILL NOT ILLUMINATE. MX REMOVED AND REPLACED EMERGENCY BATTERIES.
- [SDR FDKA2008120200304](https://openairdocs.org/sdr/FDKA2008120200304.md): Charger · inoperative · Dec 2, 2008 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6189 JFK-RIC. ROW 12 LT EMERGENCY EXIT SIGN INOP. MX REMOVED AND REPLACED NR 3 BATTERY CHARGER, OPS CHECK GOOD.
- [SDR FDKA2008110800291](https://openairdocs.org/sdr/FDKA2008110800291.md): Light · malfunctioned · Nov 8, 2008 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FRL FLT 6268 CVG. EMERGENCY OVERHEAD LIGHT OUT AT ROW 12. MX PERFORMED OPS CHECKS, OPS GOOD.
- [SDR FDK2008F00016](https://openairdocs.org/sdr/FDK2008F00016.md): Light · malfunctioned · Oct 5, 2008 · N857MJ · Emb EMB145LR · Emergency Lighting
  > ROW 12 OVERHEAD EMERGENCY LIGHT INOPERATIVE. MX OPS CHECKED THE SYS, NORMAL AFTER RESET. (K)
- [SDR FDKA200805208](https://openairdocs.org/sdr/FDKA200805208.md): Warning Light · malfunctioned · May 23, 2008 · N857MJ · Emb EMB145LR · Extinguishing System
  > FDM FLT 6101 ROC - BAG EXTINGUISHING LIGHT STAYS ON AFTER TEST. MX RE-TESTED SYSTEM, OPS CHECK GOOD.
- [SDR FDKA200805200](https://openairdocs.org/sdr/FDKA200805200.md): Sign · inoperative · May 12, 2008 · N857MJ · Emb EMB145LR · Emergency Lighting
  > FDM 6106 CVG-CMH. OVERHEAD CEILING EMERGENCY EXIT SIGN INOP. FLIGHT CREW CYCLED POWER TO SYSTEM. NO FURTHER DEFECTS NOTED.
- [SDR FDKA200804168](https://openairdocs.org/sdr/FDKA200804168.md): Connector · loose · Apr 17, 2008 · N857MJ · Emb EMB145LR · Light System Wiring
  > FDM 6025 CVG-CLT (0650 PHX LCL). EMERGENCY PLACARD AT LEFT ROW 12 EMERGENCY EXIT DOES NOT ILLUMINATE. MX RESECURED CONNECTORS ON LIGHT ASSY AND RESET LIGHTING SYSTEM, OPS CHECK GOOD.
- [SDR FDKA200803135](https://openairdocs.org/sdr/FDKA200803135.md): Roller · lack of lube · Mar 27, 2008 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > FDM RON TPA (1619 PHX LCL). PAX DOOR WILL NOT CLOSE. MX LUBED THE DOOR ROLLERS AND OPS CHECKED.
- [SDR FDKA200712424](https://openairdocs.org/sdr/FDKA200712424.md): Connector · dirty · Dec 29, 2007 · N857MJ · Emb EMB145LR · Ice/Rain Protection System Wiring
  > FDM FLT 6107 ALB (0548 PHX LCL) - ABORTED T/O DUE TO WING/STAB ANTI-ICE FAIL. MX CLEANED AND RESEATED NR 1 AND NR 2 WING ANTI-ICE LOW PRESSURE SWITCHES AND OPS CHECKED SYSTEM, OPS GOOD.
- [SDR FDKA200711328](https://openairdocs.org/sdr/FDKA200711328.md): Latch · lack of lube · Nov 9, 2007 · N857MJ · Emb EMB145LR · Passenger/Crew Doors
  > FDM 6064 BHM (0407 PHX LCL) - MAIN CABIN DOOR HARD TO OPEN AND CLOSE. MX LUBRICATED DOOR LATCH ASSY. OPS CHECK GOOD.
- [SDR FDKA200710530](https://openairdocs.org/sdr/FDKA200710530.md): Grommet · torn · Oct 8, 2007 · N857MJ · Emb EMB145LR · Fire Bottle, Fixed
  > FDM 6053 TPA (0341 PHX LCL) - NR 2 ENGINE FIRE BOTTLE T-HANDLE GROMMET TORN. MX REPAIRED.
- [SDR FDKA200709502](https://openairdocs.org/sdr/FDKA200709502.md): Frame · chafed · Sep 20, 2007 · N857MJ · Emb EMB145LR · Nacelle/Pylon, Frame/Spar/Rib
  > RT LOWER ENGINE COWLING AFT FRAME IS CHAFED BEYOND LIMITS. REMOVED AND REPLACED DAMAGED FRAME.
- [SDR FDKA200709503](https://openairdocs.org/sdr/FDKA200709503.md): Fitting · damaged · Sep 20, 2007 · N857MJ · Emb EMB145LR · Ailerons
  > LT AILERON DAMPER FITTING IS DAMAGED. THE DAMAGED FITTING HAS BEEN REMOVED AND REPLACED.
- [SDR FDKA200709500](https://openairdocs.org/sdr/FDKA200709500.md): Bracket · cracked · Sep 18, 2007 · N857MJ · Emb EMB145LR · Nacelle/Pylon, Attach Fittings
  > PRECOOLER MOUNT BRACKET CRACKED ON THE NR 2 ENGINE. REMOVED AND REPLACED MOUNT BRACKET.
- [SDR FDKA200709499](https://openairdocs.org/sdr/FDKA200709499.md): Sill · corroded · Sep 18, 2007 · N857MJ · Emb EMB145LR · Fuselage Miscellaneous Structure
  > RT SILL FWD OF SERVICE DOOR IS CORRODED OUT OF LIMITS. REMOVED AND REPLACED SILL.

Next page: https://openairdocs.org/deregistered/N857MJ-2020-10-31/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N857MJ' AND deregistration_id = 'N857MJ-2020-10-31'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N857MJ-2020-10-31/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.