# Service difficulty reports: N860GA, cancelled Jan 7, 2015

A list on [N860GA, cancelled Jan 7, 2015](https://openairdocs.org/deregistered/N860GA-2015-01-07.md).

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Page 1 of 2 · 74 reports

- [SDR WX0A2013122071794](https://openairdocs.org/sdr/WX0A2013122071794.md): Acm · odor · Dec 17, 2013 · N860GA · Doug MD83 · Cabin Cooling System
  > BOTH APU`S RUNNING A/C PACKS, EXHAUST ODOR IN CABIN. REMOVED AND REPLACED LEFT AIR CYCLE MACHINE. OPS AND LEAK CHECKED OK IAW AMM 21-51-01.
- [SDR WX0A2013120400769](https://openairdocs.org/sdr/WX0A2013120400769.md): Control Valve · burned · Dec 4, 2013 · N860GA · Doug MD83 · AC Generator-Alternator
  > APU SUSPECTED OF CAUSING CABIN ODOR. R & R APU LOAD CONTROL VALVE IAW AMM 49-50-01 PARA 2 A & B. BURNED OIL DISCOLORATION AT 7 O`CLOCK ON PREVIOUSLY INSTALLED VALVE.
- [SDR WX0A2013090571683](https://openairdocs.org/sdr/WX0A2013090571683.md): Battery · discharged · Aug 31, 2013 · N860GA · Doug DC983 · Emergency Equipment
  > FWD AED LOW BATTERY. R & R FWD DEFIBULATOR BATTERY IAW AMM 25-60-01.
- [SDR WX0A071353](https://openairdocs.org/sdr/WX0A071353.md): Skin · corroded · Oct 3, 2012 · N860GA · Doug MD83 · Fuselage Main, Plate/Skin
  > ANTENNA CUTOUT BETWEEN STA 229 TO STA 237 DOUBLER/TRIPLER CORRODED, CUTOUT DAMAGED AREA. REMOVED AND REPLACED LOWER SKIN STATION 229 TO STATION 275 LONGERON 26R TO LONGERON 27L IAW MD80 SRM 53-04 FIGURE 12C.
- [SDR WX0A071341](https://openairdocs.org/sdr/WX0A071341.md): Spar · corroded · Sep 23, 2012 · N860GA · Doug MD83 · Wing Spar
  > LEFT WING O/B FLAP CENTER HINGE FITTING UPPER I/B ATTACH FITTING HOLE SURFACE CORRODED STA XRS267.00 OF WING REAR SPAR. REMOVED DAMAGE, FABRICATED FILLER, HFEL SPAR & BOND IN REPAIR PART IAW EA 14874IR 09/23/2012.
- [SDR WX0A071320](https://openairdocs.org/sdr/WX0A071320.md): Pan · bent · Sep 22, 2012 · N860GA · Doug MD83 · Cargo/Baggage Doors
  > AFT CARGO DOOR ENTER PAN BENT AT FWD LOWER EDGE. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED IAW STS EA 12-2012-308 DATED 09/14/2012.
- [SDR WX0A071319](https://openairdocs.org/sdr/WX0A071319.md): Longeron · corroded · Sep 19, 2012 · N860GA · Doug MD83 · Fuselage Main, Longeron/Stringer
  > AFTER INTERNAL OPEN UP OF AFT CARGO ANTENNAS, AREA AT LONGERON 30 IS CORRODED BETWEEN FS 1155 AND FS 1174. REPAIRED LONGERON 30 BY FABRICATING U-CHANNELS, SHIMS AND INSTALLING REPAIR PARTS IAW STS EA 10-2012-203.
- [SDR WX0A071318](https://openairdocs.org/sdr/WX0A071318.md): Skin · dented · Sep 12, 2012 · N860GA · Doug MD83 · Fuselage Main, Plate/Skin
  > RIGHT FWD FUSELAGE STA 256 LONGERON 18R TO 20R HAS THREE SHARP DENTS. REMOVED DAMAGE STA 227 TO 269.5 LONGERON 18R TO 20R. FABRICATED ALL PARTS AND INSTALLED IAW MD80 SRM 53-04 FIG 12C.
- [SDR WX0A071316](https://openairdocs.org/sdr/WX0A071316.md): Seat Track · corroded · Sep 12, 2012 · N860GA · Doug MD83 · Fuselage, Seat/Cargo Attach Fittings
  > AFT PASSENGER CABIN SEAT TRACK STA 1155 TO 1250 LBL 22 CORRODED. REMOVED AND REPLACED SEAT TRACK WITH SPLICE AT STA 1250 & 1871 IAW MD-80 SRM 51-30-1.
- [SDR WX0A071263](https://openairdocs.org/sdr/WX0A071263.md): Battery · discharged · Aug 9, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071182](https://openairdocs.org/sdr/WX0A071182.md): Battery Pack · discharged · Apr 22, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A071181](https://openairdocs.org/sdr/WX0A071181.md): Light · inoperative · Apr 22, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE A
- [SDR WX0A071156](https://openairdocs.org/sdr/WX0A071156.md): Battery · discharged · Apr 6, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A071155](https://openairdocs.org/sdr/WX0A071155.md): Battery · discharged · Apr 6, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A2012020371107](https://openairdocs.org/sdr/WX0A2012020371107.md): Battery · inoperative · Feb 3, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN THE POWER SUPPLY BATTERY PACK. AN OPERATIONAL CHECK WAS ACCOMPL
- [SDR WX0A2012012871095](https://openairdocs.org/sdr/WX0A2012012871095.md): Battery Pack · inoperative · Jan 28, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED BATTERY PACK IN THE POWER SUPPLY AND OPS CHECK WAS ACCOMPLISHED PER AMM 33-50-0
- [SDR WX0A071088](https://openairdocs.org/sdr/WX0A071088.md): Light · inoperative · Jan 20, 2012 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE PORTABLE EMERGENCY EXIT LIGHT ASSY A
- [SDR WX0A070997](https://openairdocs.org/sdr/WX0A070997.md): Battery · discharged · Nov 13, 2011 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070975](https://openairdocs.org/sdr/WX0A070975.md): Battery · discharged · Oct 15, 2011 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070974](https://openairdocs.org/sdr/WX0A070974.md): Battery Pack · discharged · Oct 10, 2011 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A070908](https://openairdocs.org/sdr/WX0A070908.md): Coalescer Bag · dirty · Jul 30, 2011 · N860GA · Doug MD83 · Cabin Cooling System
  > AIR RETURN DUE TO SMELL OF BURNING AND SMOKE IN CABIN. DROPPED PSU'S AND CLEANED PANELS, NO ODORS OR EVIDENCE OF BURNING NOTED. REMOVED AND REPLACED COALESCER BAGS, REF AMM 21-20-02 RAN ENGINES REF AMM 71-00-00 OPS CHECK NORMAL. AIRCRAFT RETURNED TO SERVICE
- [SDR WX0A070892](https://openairdocs.org/sdr/WX0A070892.md): Battery · discharged · Jun 19, 2011 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE EMERGENCY FLASHLIGH
- [SDR WX0A070781](https://openairdocs.org/sdr/WX0A070781.md): Battery Pack · discharged · Feb 25, 2011 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A070776](https://openairdocs.org/sdr/WX0A070776.md): Membrane · cracked · Feb 16, 2011 · N860GA · Doug MD83 · Fuselage Miscellaneous Structure
  > FWD CABIN FLOOR WEB MEMBRANE CRACKED AT STA 200, RBL 40 TO RBL 46. REMOVED DAMAGED WEB RBL 25 TO RBL 56 STA 200 TO STA 218. FABRICATED, LOCATED, DRILLED AND INSTALLED IAW MD80 SRM 51-30-2 AND SRM 51-30-5.
- [SDR WX0A070775](https://openairdocs.org/sdr/WX0A070775.md): Angle · corroded · Feb 16, 2011 · N860GA · Doug MD83 · Fuselage Miscellaneous Structure
  > CABIN FLOOR UPPER CUSP ANGLE CORRODED AT R1 DOOR JAMB. CUT OUT DAMAGED AREAS, FABRICATED, LOCATED, DRILLED AND INSTALLED CUSP ANGLE, SPLICES SHIMS, DOUBLERS AND FILLERS IAW MD80 SRM 53-05 FIG 55.
- [SDR WX0A070767](https://openairdocs.org/sdr/WX0A070767.md): Diaphragm · corroded · Feb 15, 2011 · N860GA · Doug MD83 · Fuselage Miscellaneous Structure
  > FWD CABIN MEMBRANE WEB CORRODED AND DENTED STA 200. CUT OUT DAMAGED WEB STA 160 TO STA 200, LBL 10 TO RBL 60. FABRICATED, LOCATED, DRILLED AND INSTALLED WEB REPAIR IAW MD80 SRM 51-70-4 FIG 2.
- [SDR WX0A070766](https://openairdocs.org/sdr/WX0A070766.md): Doubler · corroded · Feb 13, 2011 · N860GA · Doug MD83 · Fuselage Miscellaneous Structure
  > DOOR WEB DOUBLER STA 160 TO STA 200, RBL 54 TO RBL 60 CORRODED. FABRICATED AND INSTALLED NEW DOUBLER IAW MD80 SRM 51-30-2.
- [SDR WX0A070765](https://openairdocs.org/sdr/WX0A070765.md): Membrane · corroded · Feb 13, 2011 · N860GA · Doug MD83 · Fuselage Miscellaneous Structure
  > WEB MEMBRANE RBL 7 TO RBL 40 STA 120 TO STA 150 CORRODED. REMOVED, FABRICATED NEW AND INSTALLED MEMBRANE IAW MD80 SRM 51-70-4 FIG 2.
- [SDR WX0A070764](https://openairdocs.org/sdr/WX0A070764.md): Seat Track · corroded · Feb 13, 2011 · N860GA · Doug MD83 · Fuselage, Seat/Cargo Attach Fittings
  > COPILOTS INBOARD SEAT TRACK CORRODED. ORDERED AND RECEIVED NEW TRACK, LOCATED AND DRILLED IAW MD80 SRM 51-10-4.
- [SDR WX0A070763](https://openairdocs.org/sdr/WX0A070763.md): Seat Track · corroded · Feb 13, 2011 · N860GA · Doug MD83 · Fuselage, Seat/Cargo Attach Fittings
  > COPILOTS OUTBOARD SEAT TRACK CORRODED. ORDERED AND RECEIVED NEW TRACK LOCATED AND DRILLED IAW MD80 SRM 51-10-4.
- [SDR WX0A070640](https://openairdocs.org/sdr/WX0A070640.md): Battery Pack · discharged · Oct 30, 2010 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A070537](https://openairdocs.org/sdr/WX0A070537.md): Battery · discharged · Feb 20, 2010 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070535](https://openairdocs.org/sdr/WX0A070535.md): Light · inoperative · Feb 18, 2010 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REPLACED EMERGENCY LIGHT ASSEMBLY AS REQUIRED. A SATISFACTORY OPERATIONA
- [SDR WX0A070533](https://openairdocs.org/sdr/WX0A070533.md): Battery · discharged · Feb 17, 2010 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070522](https://openairdocs.org/sdr/WX0A070522.md): Battery Pack · discharged · Feb 5, 2010 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A070502](https://openairdocs.org/sdr/WX0A070502.md): Power Supply · discharged · Nov 26, 2009 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
- [SDR WX0A070417](https://openairdocs.org/sdr/WX0A070417.md): Battery Pack · no test · Sep 24, 2009 · N860GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070389](https://openairdocs.org/sdr/WX0A070389.md): Web · corroded · Aug 18, 2009 · N860GA · Doug MD83 · Fuselage Miscellaneous Structure
  > IN WORK, BOW 1C/5C/S1 FOUND CORROSION ON SURFACE OF WEB.
- [SDR WX0A070388](https://openairdocs.org/sdr/WX0A070388.md): Track · corroded · Aug 18, 2009 · N860GA · Doug MD83 · Fuselage, Seat/Cargo Attach Fittings
  > CORROSION ON RT TIE DOWN TRACK BETWEEN STA 1212 - 1322.
- [SDR WX0A070387](https://openairdocs.org/sdr/WX0A070387.md): Track · corroded · Aug 18, 2009 · N860GA · Doug MD83 · Fuselage, Seat/Cargo Attach Fittings
  > CORROSION IN LT TIE DOWN TRACK BETWEEN STA 1220-1322.
- [SDR WX0A070386](https://openairdocs.org/sdr/WX0A070386.md): Cargo Track · corroded · Aug 18, 2009 · N860GA · Doug MD83 · Fuselage, Seat/Cargo Attach Fittings
  > AFT CARGO LT TIE DOWN TRACK SPLICE CORRODED AT STA 1220. INSTALLED A SERVICEABLE TIE DOWN TRACK SPLICE PER SRM 51-30-05.
- [SDR WX0A070385](https://openairdocs.org/sdr/WX0A070385.md): Skin · cracked · Aug 14, 2009 · N860GA · Doug MD83 · Fuselage Main, Plate/Skin
  > CRACKS ON FUSELAGE SKIN STA 1380 L14R (2EA).
- [SDR WX0A070384](https://openairdocs.org/sdr/WX0A070384.md): Cusp Web · corroded · Aug 7, 2009 · N860GA · Doug MD83 · Fuselage Miscellaneous Structure
  > CUSP WAS FOUND TO HAVE CORROSION ON BOTTOM SIDE OF CUSP AT STA 845-907 LT.
- [SDR WX0A070379](https://openairdocs.org/sdr/WX0A070379.md): Battery · discharged · Aug 1, 2009 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070356](https://openairdocs.org/sdr/WX0A070356.md): Battery · discharged · Jul 23, 2009 · N860GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070279](https://openairdocs.org/sdr/WX0A070279.md): Battery Pack · inoperative · Mar 1, 2009 · N860GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070269](https://openairdocs.org/sdr/WX0A070269.md): Battery Pack · inoperative · Jan 30, 2009 · N860GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR 070156](https://openairdocs.org/sdr/070156.md): Deice System · failed · Sep 12, 2007 · N860GA · Doug DC983 · Windshield/Door Rain/Ice Removal
  > DURING PILOTS PREFLIGHT INSPECTION, SMOKE STARTED TO FILL THE COCKPIT. NOTICED THE SMOKE COMING FROM THE CAPTAINS LEFT CORNER OF THE WINDSHIELD. SHUT OFF ALL AC ELECTRICAL POWER AND SMOKE WAS EXTINGUISHED. WINDSHIELD DE ICE SYSTEM WAS DEFERRED IAW ALLEGIAN
- [SDR WX0A070147](https://openairdocs.org/sdr/WX0A070147.md): Battery Pack · no test · Aug 17, 2007 · N860GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISF
- [SDR 070129](https://openairdocs.org/sdr/070129.md): Outflow Valve · obstructed · Jun 24, 2007 · N860GA · Doug DC983 · Pressure Regulator/Outflow Valve
  > AIRCRAFT 860 DEPARTED LAS FLT 418 AND CLIMBING THROUGH 18,000 FEET THE CABIN PRESSURIZATION FLOW LIGHT ILLUMINATED. CREW WAS UNABLE TO EXTINGUISH LIGHT AND RETURNED TO LAS. MAINTENANCE DEPARTMENT PERSONNEL INSPECTED THE PRESSURIZATION SYSTEM AND DISCOVERED I

Next page: https://openairdocs.org/deregistered/N860GA-2015-01-07/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N860GA' AND deregistration_id = 'N860GA-2015-01-07'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N860GA-2015-01-07/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.