- [SDR WX0A201704050001](https://openairdocs.org/sdr/WX0A201704050001.md): Generator · failed · Apr 3, 2017 · N862GA · Doug DC983 · AC Generator-Alternator
  > LEAVING CRUISE ALTITUDE, ELECTRICAL INTERRUPTION RESULTED IN AUTOPILOT & AT DISCONNECT, FOLLOWED BY DFGC FAILURES, LOSS OF ALL FO FLIGHT INSTRUMENTATION AND FLAGGING OF FO PRIMARY FLIGHT INSTRUMENTS. AOP SCREEN WAS DIFFICULT TO READ AS FAULT MESSAGES WERE LAYE
- [SDR WX0A2017032773233](https://openairdocs.org/sdr/WX0A2017032773233.md): Duct · not reported · Mar 25, 2017 · N862GA · Doug DC983 · Turbine Engine Reduction Gear
  > EMERGENCY DECLARED, RT ENGINE FIRE DETECTOR LOOP ANNUNCIATOR ILLUMINATED, IMMEDIATELY FOLLOWED BY RT ENGINE FIRE. R&R RT ENG AFT IGV DUCT, FUEL/AIR HEATER AIR SHUTOFF VALVE, AND MAIN OIL FILTER.
- [SDR JR2R20170209116](https://openairdocs.org/sdr/JR2R20170209116.md): Stiffener · cracked · Feb 9, 2017 · N862GA · Doug MD83 · Nacelle/Pylon Miscellaneous Structure
  > BOTTOM OF STIFFINER INSIDE OF NR 2 ENG NOSE COWL CRACKED AT 7:30 POSISTION. REMOVED AND REPLACED THE STIFFNER IAW EA40-2017-015.
- [SDR WX0A2015113000016](https://openairdocs.org/sdr/WX0A2015113000016.md): Battery Pack · inoperative · Nov 26, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > EMERGENCY LIGHTING IN TAILCONE INOPERATIVE. R & R EMERGENCY BATTERYS IAW AMM 33-53-00, OP CHECK GOOD.
- [SDR WX0A2015102072958](https://openairdocs.org/sdr/WX0A2015102072958.md): Wire · chafed · Oct 18, 2015 · N862GA · Doug DC983 · Landing Gear System Wiring
  > WHEN LG RETRACTED, CB 26P, LG WARNING POPS. AFTER TAKEOFF, WHEN LG RETRACTED, ALL 4 ANTI-SKID ANNUNCIATORS ILLUMINATED. RAN QRH 32.2 & CONTINUED FLIGHT. FOUND LG ANTI-RETRACTION CABLE TENSION SPRING CHAFING WIRE G200C22. CONNECTED CABLE TENSION SPRING TO B
- [SDR WX0A2015100172909](https://openairdocs.org/sdr/WX0A2015100172909.md): Slat · damaged · Sep 28, 2015 · N862GA · Doug DC983 · Leading Edge Devices
  > RIGHT NR 5 SLAT DAMAGED. R & R NR 5 RT SLAT IAW AMM 27-80=-01-4-0.
- [SDR WX0A2015080372767](https://openairdocs.org/sdr/WX0A2015080372767.md): Battery · discharged · Jul 27, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > COCKPIT & GALLEY AREA EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES. OPERATIONS CHECKED GOOD IAW MM 33-53-00.
- [SDR WX0A2015070972724](https://openairdocs.org/sdr/WX0A2015070972724.md): Charger · inoperative · Jul 3, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > COCKPIT OVERHEAD EMER LIGHT DOES NOT WORK WITH EMER LIGHT SWITCH. REPLACED BATTERY CHARGER & BATTERY PACK IAW MM 33-53-00.
- [SDR WX0A072713](https://openairdocs.org/sdr/WX0A072713.md): Battery Pack · discharged · Jun 30, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > EMERGENCY LIGHT NOT TURNING ON AT FLIGHT ATTENDANT OVERHEAD PANEL, FWD FLIGHT ATTENDANT CEILING PANEL & FWD GALLEY CELLING. R & R BATTERY PACK AT FWD FLIGHT ATTENDANT STATION IAW AMM 33-50-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2015062472686](https://openairdocs.org/sdr/WX0A2015062472686.md): Terminal · unsecure · Jun 23, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > DURING COCKPIT PREFLIGHT, EMER LIGHTS INSIDE COCKPIT WILL NOT TURN ON WITH EMER LIGHT SWITCH IN ON POSITION. SECURED TERMINAL ON COCKPIT EMER LIGHT BATTERY SUPPLY & OPERATIONS CHECKED OK IAW MM 33-53-00.
- [SDR WX0A2015060572641](https://openairdocs.org/sdr/WX0A2015060572641.md): Battery · discharged · Jun 4, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > COCKPIT EMER LIGHT NOT WORKING. R & R BATTERIES TO EMER LIGHT PACK FOR COCKPIT IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2015060372639](https://openairdocs.org/sdr/WX0A2015060372639.md): Battery · discharged · Jun 1, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > EMERGENCY LIGHTS ON OVERHEAD PANEL NOT WORKING. CHARGED BATTERIES IN ARMED POSITION OPERATIONS CHECKED GOOD AT THIS TIME IAW AMM 33-53-01.
- [SDR WX0A2015052772608](https://openairdocs.org/sdr/WX0A2015052772608.md): Power Supply · inoperative · May 22, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > FOUND ON WAKE UP, FWD CABIN & FLIGHT DECK EMER LIGHTS INOPERATIVE. REPLACED POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.
- [SDR WX0A2015052072604](https://openairdocs.org/sdr/WX0A2015052072604.md): Battery · discharged · May 19, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > COCKPIT & FWD GALLEY EMER LIGHTS OUT. R & R POWER PACK BATTERIES IAW MM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2015033072491](https://openairdocs.org/sdr/WX0A2015033072491.md): Battery · discharged · Mar 27, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > AT ROW 26, ONE EMER LIGHT INOPERATIVE & ROW 27, ONE EMER LIGHT INOPERATIVE. REPLACED BATTERIES TO POWER SUPPLY AT ROW 27. LIGHTS FOR BOTH LAMPS VERY DIM. REPLACED POWER SUPPLY. EMER LIGHTS CHECKED NORMAL IAW AMM 33-53-01.
- [SDR WX0A2015081172791](https://openairdocs.org/sdr/WX0A2015081172791.md): Tire · damaged · Feb 23, 2015 · N862GA · Doug DC983 · Tire
  > EMERGENCY DECLARED FOR SEVERE NOSE WHEEL VIBRATION DURING & AFTER TAKEOFF FROM RNWY 1R. THE CREW HELD TO BURN OFF FUEL TO BE BELOW MAXIMUM LANDING WEIGHT FOR THE LANDING. IN HOLDING, HEARD A LOUD SINGLE POP & IN THE DESCENT HEARD A LOUD SINGLE POP. THIS POP
- [SDR WX0A2015022372435](https://openairdocs.org/sdr/WX0A2015022372435.md): Battery · discharged · Feb 22, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > FLIGHT DECK EMER LIGHTS WILL NOT ILLUMINATE WHEN SELECTED ON. R & R EMER LIGHT BATTERIES IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2015010772338](https://openairdocs.org/sdr/WX0A2015010772338.md): Battery · discharged · Jan 3, 2015 · N862GA · Doug DC983 · Emergency Lighting
  > FWD AISLE EMER LIGHT & COCKPIT EMER LIGHT INOPERATIVE. REPLACED EMER LIGHT POWER SUPPLY BATTERIES IAW AMM 33-53-00-4. OPERATIONS CHECKED OK.
- [SDR WX0A2014122272314](https://openairdocs.org/sdr/WX0A2014122272314.md): Battery Pack · discharged · Dec 19, 2014 · N862GA · Doug DC983 · Emergency Lighting
  > FORWARD EMER LAMPS INOPERATIVE, DIM. REPLACED BATTERY PACK IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2014110772259](https://openairdocs.org/sdr/WX0A2014110772259.md): Light · inoperative · Nov 4, 2014 · N862GA · Doug DC983 · Emergency Lighting
  > AFT CABIN DOOR EMER EXIT LIGHT INOPERATIVE. R & R AFT CABIN DOOR EMER EXIT LAMP. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.
- [SDR WX0A072244](https://openairdocs.org/sdr/WX0A072244.md): Battery · discharged · Oct 30, 2014 · N862GA · Doug DC983 · Emergency Lighting
  > EMERGENCY LIGHT INSIDE COCKPIT DOES NOT LIGHT UP WHEN TESTED. REPLACED BATTERIES AT FWD GALLEY BATTERY PACK IAW MM 33-53-00. OPERATIONS CHECKED NORMAL.
- [SDR WX0A072189](https://openairdocs.org/sdr/WX0A072189.md): Battery · discharged · Oct 5, 2014 · N862GA · Doug DC983 · Emergency Lighting
  > FLIGHT DECK EMER LIGHTS NOT WORKING. RELAMPED & REPLACED BATTERIES IAW MM 33-50-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2014090972143](https://openairdocs.org/sdr/WX0A2014090972143.md): Battery · discharged · Sep 2, 2014 · N862GA · Doug MD83 · Emergency Lighting
  > FORWARD EMER BATTERY NEEDS TO BE CHANGED, LIGHTS OUT. R & R EMER BATTERY IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A2014090472135](https://openairdocs.org/sdr/WX0A2014090472135.md): Seat Track · corroded · Aug 30, 2014 · N862GA · Doug DC983 · Fuselage, Seat/Cargo Attach Fittings
  > PASSENGER CABIN LT SEAT TRACK IS CORRODED AT STATION 200 LBL 44. REMOVED DAMAGE SECTION OF SEAT TRACK, FABRICATED REPAIRS SLICE & INSTALLED SLICE & NEW SEAT TRACK IAW SRM 53-05 FIG 4F WORK ORDER 228223 M301 284 WORK ORDER 1011150 2400 - 0105.
- [SDR WX0A2014090372130](https://openairdocs.org/sdr/WX0A2014090372130.md): Battery · discharged · Aug 30, 2014 · N862GA · Doug DC983 · Emergency Lighting
  > FORWARD EMER LIGHTS OUT STATION 300. R & R FWD EMER BATTERIES IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.
- [SDR WX0A2014090372129](https://openairdocs.org/sdr/WX0A2014090372129.md): Battery · discharged · Aug 28, 2014 · N862GA · Doug DC983 · Emergency Lighting
  > EMERGENCY LIGHT BULB IN COCKPIT INOPERATIVE. REPLACED EMER LIGHT BATTERIES. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.
- [SDR WX0A2014080572078](https://openairdocs.org/sdr/WX0A2014080572078.md): Unknown · malfunctioned · Aug 3, 2014 · N862GA · Doug MD83 · Weather Radar System
  > WEATHER RADAR FAILED INFLIGHT. PERFORMED OPERATIONS TEST OF WEATHER RADAR SYS IAW AMM 34-41-00. SYSTEM TESTED GOOD. SUSPECT WEATHER RADAR FAILED DUE TO ATTITUDE LOSS FROM DFGC 1 & DFGC 2. SEE LOG PAGE 539257, NO HISTORY PAST 30 DAYS. 8/5/14 NO HISTORY BA
- [SDR WX0A2014080572077](https://openairdocs.org/sdr/WX0A2014080572077.md): Selector · faulty · Aug 1, 2014 · N862GA · Doug MD83 · Cabin Pressure Control System
  > ON CLIMB OUT PRESSURIZATION TRANSFER LOCKOUT & STANDBY ON LIGHTS ILLUMINATED. QRH PROCEDURES ACCOMPLISHED, LIGHTS RE-ILLUMINATED, PRESSURIZATION NORMAL. PLACED ON MEL 21-24 SIT 1 CAT C DMI 10590, PLACARD INSTALLED. PERFORMED BITE CHECK ON BOTH PRIMARY & STB
- [SDR WX0A2014071872033](https://openairdocs.org/sdr/WX0A2014071872033.md): Light · inoperative · Jul 16, 2014 · N862GA · Doug MD83 · Emergency Lighting
  > ROW 15 EMER BULB OUT. R & R ROW 15 EMER LIGHT BULB IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- [SDR WX0A071992](https://openairdocs.org/sdr/WX0A071992.md): Light · inoperative · Jun 15, 2014 · N862GA · Doug MD83 · Emergency Lighting
  > COCKPIT EMER LIGHTS INOPERATIVE. RELAMPED FLIGHT DECK EMER LAMPS. OPERATIONS CHECKED GOOD IAW AMM 33-51-00.
- [SDR WX0A071961](https://openairdocs.org/sdr/WX0A071961.md): Battery · discharged · May 26, 2014 · N862GA · Doug MD83 · Emergency Lighting
  > FLIGHT DECK EMER LIGHTS INOPERATIVE. REPLACED FWD EMER BATTERIES, OPERATIONS CHECKED GOOD IAW MM 33-53-00.
- [SDR WX0A071962](https://openairdocs.org/sdr/WX0A071962.md): Battery · discharged · May 23, 2014 · N862GA · Doug MD83 · Emergency Lighting
  > FLIGHT DECK EMER LIGHTS INOPERATIVE. R & R EMER BATTERIES IAW MM 33-53-01, OPERATIONS CHECKED GOOD.
- [SDR WX0A071808](https://openairdocs.org/sdr/WX0A071808.md): Beam · corroded · Jan 2, 2014 · N862GA · Doug MD83 · Fuselage Main, Structure
  > AFT CARGO DOOR CUTOUT LOWER JAMB BEAM CORRODED. REMOVED CORROSION & CUTOUT SMALL SECTION AT AFT DOOR STOP ON BEAM. FABRICATED REPAIR DOUBLER & REPAIR PARTS, LOCATED, DRILLED & INSTALLED PERMANENT REPAIR IAW MD80 SRM 53-05 FIGURE 123A OPTION 2
- [SDR WX0A071767](https://openairdocs.org/sdr/WX0A071767.md): Seat Track · corroded · Dec 5, 2013 · N862GA · Doug MD83 · Fuselage, Seat/Cargo Attach Fittings
  > SEAT TRACK AT LBL 44 FS 200 TO FS 218 CORRODED. R & R SEAT TRACK AT LBL 44 FS 200 TO FS 218 IAW MD-80 SRM 53-05 FIG 4H.
- [SDR WX0A2013030471526](https://openairdocs.org/sdr/WX0A2013030471526.md): Doubler · corroded · Mar 4, 2013 · N862GA · Doug DC983 · Fuselage Main, Plate/Skin
  > FWD LAV SERVICE PANEL AREA DOUBLER IS CORRODED AT THE BOTTOM OF THE FWD DOOR HINGE. CUT OUT DAMAGED AREA AT INTERNAL DOUBLER, FABRICATED REPAIR FILLER, DOUBLER AND TRIPLER AND INSTALLED REPAIR PARTS.
- [SDR WX0A071525](https://openairdocs.org/sdr/WX0A071525.md): Skin · corroded · Mar 4, 2013 · N862GA · Doug DC983 · Fuselage Main, Plate/Skin
  > AFT LAV SERVICE PAN EXTERIOR SKIN, DOUBLER AND CENTER OF LAV SERVICE PAN IS CORRODED. CUT OUT DAMAGED AREA AT INTERNAL DOUBLER, FABRICATED REPAIR FILLER DOUBLER AND TRIPLER AND INSTALLED REPAIR PARTS.
- [SDR WX0A071207](https://openairdocs.org/sdr/WX0A071207.md): Engine · malfunctioned · May 18, 2012 · N862GA · Doug MD83 · Engine (Turbine/Turboprop)
  > FLIGHT CREW PERSONNEL REPORTED THAT DURING CLIMBOUT AT APPROX FL270, LEFT ENGINE COMPRESSOR STALL/ ENGINE PARAMETERS ROLLED BACK ENGINE SHUTDOWN PER CHECKLIST. MAINTENANCE PERSONNEL REPLACED THE LEFT ENGINE IAW TASK CARD R0807101, OPS AND LEAK GOOD. AIRCRAFT
- [SDR WX0A070998](https://openairdocs.org/sdr/WX0A070998.md): Battery · discharged · Nov 3, 2011 · N862GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070976](https://openairdocs.org/sdr/WX0A070976.md): Battery · discharged · Oct 1, 2011 · N862GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070870](https://openairdocs.org/sdr/WX0A070870.md): Battery · discharged · May 30, 2011 · N862GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070543](https://openairdocs.org/sdr/WX0A070543.md): Light · inoperative · Mar 25, 2010 · N862GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REPLACED EMERGENCY LIGHT ASSEMBLY AS REQUIRED. A SATISFACTORY OPERATIONA
- [SDR WX0A070438](https://openairdocs.org/sdr/WX0A070438.md): Sensor · malfunctioned · Oct 31, 2009 · N862GA · Doug MD83 · Engine Oil Indicating System
  > LEFT ENGINE OIL TEMP HIGH (AMBER) LIGHT ILLUMINATED. REDUCED POWER, NORMAL FUEL TEMP, OIL TEMP AND OIL QUANTITY INDICATIONS. ADDED POWER TO APPROX 80 PERCENT N1, OIL TEMP REDUCED FROM A HIGH OF 149 DEGREES TO A STABLE 124 DEGREES. ENGINE NOT SHUTDOWN. MAIN
- [SDR WX0A070412](https://openairdocs.org/sdr/WX0A070412.md): Battery Pack · inoperative · Sep 10, 2009 · N862GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK, INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTE
- [SDR WX0A070362](https://openairdocs.org/sdr/WX0A070362.md): Power Supply · discharged · Jul 31, 2009 · N862GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WX0A070315](https://openairdocs.org/sdr/WX0A070315.md): Battery Pack · inoperative · May 29, 2009 · N862GA · Doug MD83 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISF
- [SDR WX0A070285](https://openairdocs.org/sdr/WX0A070285.md): Power Supply · no test · Apr 7, 2009 · N862GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISF
- [SDR WX0A070257](https://openairdocs.org/sdr/WX0A070257.md): Battery Pack · inoperative · Dec 31, 2008 · N862GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
- [SDR WXO2008F00000](https://openairdocs.org/sdr/WXO2008F00000.md): Battery Pack · failed · Aug 9, 2008 · N862GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WA
- [SDR 070177](https://openairdocs.org/sdr/070177.md): Battery Pack · discharged · Nov 11, 2007 · N862GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISF
- [SDR 070133](https://openairdocs.org/sdr/070133.md): Battery Pack · discharged · Jun 20, 2007 · N862GA · Doug DC983 · Emergency Lighting
  > DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISF

Next page: https://openairdocs.org/deregistered/N862GA-2022-10-01/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N862GA' AND deregistration_id = 'N862GA-2022-10-01'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N862GA-2022-10-01/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.