- [SDR 0401989911](https://openairdocs.org/sdr/0401989911.md): Fuel Filter · leaking · Nov 10, 2004 · N961N · Doug DC931 · APU Engine Fuel and Control
  > PILOT REPORTED A STRONG OIL/FUEL ODOR IN THE AIRCRAFT FOR ENTIRE LENGTH OF THE FLIGHT. MAINTENANCE FOUND THE APU LOW PRESSURE FUEL FILTER LEAKING 72 DROPS PER MINUTE. MAINTENANCE REPLACED THE FUEL FILTER AND PACKING. ALSO REPLACED COALESCER BAGS. COMPLIED
- [SDR 0401829911](https://openairdocs.org/sdr/0401829911.md): Skin · cracked · Sep 1, 2004 · N961N · Doug DC931 · Fuselage Main, Plate/Skin
  > DURING L-CHECK FOUND CRACK IN SKIN IN UPPER FORWARD CORNER OF FORWARD SERVICE DOOR JAMB. REPAIRED PER EA 99-199627.
- [SDR 0401819911](https://openairdocs.org/sdr/0401819911.md): Skin · cracked · Aug 24, 2004 · N961N · Doug DC931 · Fuselage Main, Plate/Skin
  > DURING L-CHECK, FOUND CRACK IN FUSELAGE NOSE SKIN AROUND FASTENERS AT BS 76.5 LBL 15 TO LBL 21. REPAIRED IAW EA 99-200584.
- [SDR 0400369911](https://openairdocs.org/sdr/0400369911.md): Striker · out of adjust · Mar 5, 2004 · N961N · Doug DC931 · Door Warning System
  > THE AFT CARGO DOOR OPEN WARNING LIGHT ILLUMINATED DURING TAKEOFF ROLL. THE TAKEOFF WAS SAFELY ABORTED AT ABOUT 130 KTS AND THE AIRCRAFT EXITED THE RUNWAY WITHOUT INCIDENT. THE WARNING INDICATION EXTINGUISHED AS THE AIRCRAFT TURNED ONTO THE TAXIWAY. MAINTENA
- [SDR 0204229911](https://openairdocs.org/sdr/0204229911.md): Skin · cracked · Dec 31, 2002 · N961N · Doug DC931 · Fuselage Main, Plate/Skin
  > During "H" check found crack in skin at upper aft corner of forward passenger door opening. Repaired per EA 99-193295.
- [SDR 0201649911](https://openairdocs.org/sdr/0201649911.md): Apu · leaking · May 20, 2002 · N961N · Doug DC931 · APU Oil System
  > DURING GROUND COOLING IN CLT, THE FLIGHT ATTENDANT NOTED A TRACE OF SMOKE IN THE CABIN. PACK WAS ADJUSTED TO WARMER TEMP AND PROBLEM ENDED. ON TAKEOFF, THE SMOKE RETURNED AND CAUSED THE FORWARD LAV SMOKE DETECTOR TO ALARM FOR ABOUT 3 MINUTES THEN CEASED. TH
- [SDR 9905329911](https://openairdocs.org/sdr/9905329911.md): Battery · discharged · Dec 16, 1999 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND VENTRAL STAIR EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES AT POWER SUPPLY B5-28, OPERATIONAL CHECK NORMAL.
- [SDR 9904429911](https://openairdocs.org/sdr/9904429911.md): Fuel Control · malfunctioned · Oct 28, 1999 · N961N · Doug DC931 · APU Engine Fuel and Control
  > DURING CRUISE FLIGHT, CABIN AND FLIGHT CREW PERSONNEL SMELLED FUMES IN THE AIRCRAFT. CATPAIN AND FIRST OFFICER DONNED OXYGEN MASKS. AN UNEVENTFUL LANDING WAS MADE AT DESTINATION AIRPORT. MAINTENANCE FOUND THAT FUEL WAS BEING INGESTED INTO THE APU. SOURCE O
- [SDR 9903909911](https://openairdocs.org/sdr/9903909911.md): Engine · failed · Sep 16, 1999 · N961N · Doug DC931 · Engine (Turbine/Turboprop)
  > AFT LEFT LAVATORY SMOKE DETECTOR SOUNDED WITH PASSENGER REPORTING STRANGE ODOR IN BACK OF CABIN. FLIGHT WAS RETURNED TO BHM AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED HEAT EXCHANGERS.
- [SDR 9809639911](https://openairdocs.org/sdr/9809639911.md): Shutoff Valve · malfunctioned · Jun 22, 1998 · N961N · Doug DC931 · Rudder Control System
  > AFTER TAKEOFF, RUDDER WAS ABNORMALLY SENSITIVE TO SMALL AMOUNTS OF INPUT WITH DIFFICULTY TRACKING CENTERLINE. FLIGHT WAS RETURNED TO MEM AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED RUDDER POWER SHUTOFF VALVE, OPERATIONAL CHECK NORMAL.
- [SDR 9802599911](https://openairdocs.org/sdr/9802599911.md): Battery Pack · discharged · Feb 12, 1998 · N961N · Doug DC931 · Emergency Lighting
  > DURING PERIODIC CHECK, FOUND TAILCONE CATWALK AND RELEASE HANDLE EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK NORMAL.
- [SDR 9722059911](https://openairdocs.org/sdr/9722059911.md): Battery Pack · discharged · Nov 24, 1997 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK IN AFT CARGO CEILING. OPERATIONAL CHECK NORMAL.
- [SDR 9717189911](https://openairdocs.org/sdr/9717189911.md): Batteries · discharged · Sep 9, 1997 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND AFT FLIGHT ATTENDANT AND TAIL CONE SIDEWALL EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.
- [SDR 9715679911](https://openairdocs.org/sdr/9715679911.md): Battery Packs · discharged · Aug 16, 1997 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND BOTH ENGINE PYLON EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACKS, OPERATIONAL CHECK NORMAL.
- [SDR 9711639911](https://openairdocs.org/sdr/9711639911.md): Servo · failed · Jun 14, 1997 · N961N · Doug DC931 · Directional Gyro and Indicating System
  > DURING CLIMBOUT, NR 1 COMPASS STARTED AN IMMEDIATE DRIFT WITH NO SLAVING WHEN ALIGNED TO PROPER HEADING. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED NR 1 COMPASS RACK, SERVO, AND SLAVE AMPLIFIERS, OPERATIONAL CHECK NORMAL.
- [SDR 9710479911](https://openairdocs.org/sdr/9710479911.md): Fuel Control · failed · May 26, 1997 · N961N · Doug DC931 · Fuel Control/Turbine Engines
  > DURING CLIMB, THE LEFT ENGINE EPR, N1, AND N2 INDICATIONS BEGAN FLUCTUATING. AIRCRAFT RETURNED TO MSP AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE LEFT ENGINE FUEL CONTROL UNIT. ENGINE OPERATIONAL CHECK OK. AIRCRAFT RETURNED TO SERVICE. PO
- [SDR 9709429911](https://openairdocs.org/sdr/9709429911.md): Stall Warning · activated · May 13, 1997 · N961N · Doug DC931 · Stall Warning System
  > STALL WARNING STICK SHAKER ACTIVATED AT 190 KNOTS AFTER TAKEOFF. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY ON GROUND WITH TEST EQUIPMENT. REPLACED THE LEFT STALL WARNING TRANSDUCER AND BOTH STALL WARNING
- [SDR 9704319911](https://openairdocs.org/sdr/9704319911.md): Uplock Switch · malfunctioned · Feb 27, 1997 · N961N · Doug DC931 · Landing Gear Position and Warning
  > LEFT MAIN GEAR UNSAFE LIGHT REMAINED ON AFTER GEAR RETRACTION ACCOMPANIED BY GEAR DOOR OPEN LIGHT. CREW RECYCLED GEAR WITH SAME RESULTS. FLIGHT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. MAINTENANCE JACKED AIRCRAFT AND CYCLED GEAR NUMEROUS TIMES. DISCREP
- [SDR 9703689911](https://openairdocs.org/sdr/9703689911.md): Batteries · discharged · Feb 19, 1997 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES IN PACK. OPERATIONAL CHECK NORMAL.
- [SDR 9703369911](https://openairdocs.org/sdr/9703369911.md): Battery · discharged · Feb 17, 1997 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND TAILCONE EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES IN BATTERY PACK, OPERATIONAL CHECK NORMAL.
- [SDR 9627529911](https://openairdocs.org/sdr/9627529911.md): Connector · loose · Dec 31, 1996 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND FLOOR PROXIMITY EMERGENCY LIGHTS BETWEEN ROWS 1 THROUGH 4 INOPERATIVE. MAINTENANCE RESEATED SPLICE CONNECTOR IN OVERHEAD, OPERATIONAL CHECK NORMAL.
- [SDR 9627099911](https://openairdocs.org/sdr/9627099911.md): Connector · damaged · Dec 28, 1996 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY, NO HELP. REPAIRED BAD CONNECTOR BEHIND SIDEWALL, OPERATIONAL CHECK NORMAL.
- [SDR 9626839911](https://openairdocs.org/sdr/9626839911.md): Evac Slide · low battery · Dec 22, 1996 · N961N · Doug DC931 · Escape Slide
  > DURING PERIODIC CHECK, MAIN CABIN DOOR EVACUATION SLIDE FAILED EMERGENCY BATTERY TEST. REPLACED SLIDE.
- [SDR 9623889911](https://openairdocs.org/sdr/9623889911.md): Fitting · corroded · Nov 8, 1996 · N961N · Doug DC931 · Fuselage Miscellaneous Structure
  > DURING M-CHECK, FOUND CORROSION IN THE FS 218 CUSP FITTING AT LONGERON 18R. REPLACED FITTING PER 51-10-4, 53-01.
- [SDR 9623869911](https://openairdocs.org/sdr/9623869911.md): Fitting · cracked · Nov 6, 1996 · N961N · Doug DC931 · Fuselage Miscellaneous Structure
  > DURING M-CHECK, FOUND A CRACK IN THE RBL 42 SEAT TRACK TO FS 680 FLOORBEAM ATTACH FITTING. REPLACED FITTING PER SRM 53-30-2.
- [SDR 9621469911](https://openairdocs.org/sdr/9621469911.md): Outflow Valve · blocked by fod · Oct 8, 1996 · N961N · Doug DC931 · Pressure Regulator/Outflow Valve
  > AUTO PRESSURIZATION SYSTEM FAILED AFTER TAKEOFF. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND INSULATION LODGED IN OUTFLOW VALVE WHICH WAS RESTRICTING MOVEMENT. REMOVED INSULATION AND REPLACED OUTFLOW VALVE ACTUATOR. OPERATIONAL CH
- [SDR 9616269911](https://openairdocs.org/sdr/9616269911.md): Batteries · discharged · Jul 28, 1996 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND LEFT ENGINE NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERIES. OPERATIONAL CHECK NORMAL.
- [SDR 9614869911](https://openairdocs.org/sdr/9614869911.md): Batteries · discharged · Jul 5, 1996 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND FLOOR PROXIMITY EMERGENCY LIGHTS IN MID CABIN INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.
- [SDR 9614859911](https://openairdocs.org/sdr/9614859911.md): Battery Pack · discharged · Jul 5, 1996 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE MAINTENANCE INSPECTION, FOUND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AND BATTERIES, OPERATIONAL CHECK NORMAL.
- [SDR 9608989911](https://openairdocs.org/sdr/9608989911.md): Uplock Assy · failed · Apr 20, 1996 · N961N · Doug DC931 · Landing Gear Retraction/Extension System
  > RIGHT MAIN LANDING GEAR UNSAFE LIGHT REMAINED ON AFTER GEAR WAS RETRACTED. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND FAULT IN RIGHT MAIN GEAR UPLOCK ASSEMBLY. REPLACED UPLOCK ASSEMBLY AND OPERATIONAL CHECK NORMAL.
- [SDR 9606889911](https://openairdocs.org/sdr/9606889911.md): Altimeter · failed · Mar 23, 1996 · N961N · Doug DC931 · Altimeter, Barometric/Encoder
  > FIRST OFFICER'S ALTIMETER FAILED DURING CLIMBOUT AT APPROXIMATELY 11,500 FEET. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED FIRST OFFICER'S ALTIMETER AND OPERATIONAL CHECK NORMAL.
- [SDR 9601289911](https://openairdocs.org/sdr/9601289911.md): Retract Mech · malfunctioned · Jan 19, 1996 · N961N · Doug DC931 · Landing Gear Door Retract Section
  > DURING TAKEOFF, A VIBRATION WAS DETECTED FROM THE NOSE WHEEL. AIRCRAFT CONTINUED TAKEOFF AND RETURNED TO MSP LANDING WITHOUT INCIDENT. FOUND RIGHT NOSE LANDING GEAR DOOR OPEN. SECURED DOOR AND OPERATIONAL CHECK GOOD.
- [SDR 9520099911](https://openairdocs.org/sdr/9520099911.md): Eel Power Supply · inoperative · Dec 11, 1995 · N961N · Doug DC931 · Emergency Lighting
  > DURING LINE CHECK, FOUND BOTH NACELLE EMERGENCY LIGHTS AND BOTH TAIL SLIDE LIGHTS INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY. OPERATIONAL CHECK GOOD.
- [SDR 9518809911](https://openairdocs.org/sdr/9518809911.md): Retract Mech · lack of lube · Nov 19, 1995 · N961N · Doug DC931 · Landing Gear Door Retract Section
  > DURING CLIMB, A VIBRATION WAS FELT FROM THE NOSE LANDING GEAR, AFTER LANDING GEAR RETRACTION. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. FOUND RIGHT NOSE LANDING GEAR DOOR OPEN. INSPECTED ALL HINGE POINTS AND DOOR RELEASE MECHANISM, LUBRICATED ALL
- [SDR 9518339911](https://openairdocs.org/sdr/9518339911.md): Temp Control · malfunctioned · Nov 18, 1995 · N961N · Doug DC931 · Cabin Temperature Controller
  > YXE - DURING CLIMB, SMOKE ACCUMULATED IN THE CABIN, CREW FOLLOWED COCKPIT OPERATING MANUAL PROCEDURES. AIRCRAFT RETURNED TO YXE AND LANDED WITHOUT INCIDENT. REPLACED THE LEFT AIR CONDITIONING PACK CONTROLLER AND COALESCER BAG, OPERATIONAL CHECK GOOD.
- [SDR 9512239912](https://openairdocs.org/sdr/9512239912.md): Fuel Heat Valve · malfunctioned · Aug 13, 1995 · N961N · Doug DC931 · Engine Fuel Distribution
  > NR 1 ENGINE FUEL HEAT VALVE OPENED IN FLIGHT AND COULD NOT BE CLOSED WITH NORMAL PROCEDURES. THE ENGINE OIL TEMPERATURE EXCEEDED RECOMMENDED LIMITS, THE COM PROCEDURES WERE FOLLOWED AND A PRECAUTIONARY SHUTDOWN WAS ACCOMPLISHED. FLIGHT DIVERTED TO DTW AND LA
- [SDR 9510049911](https://openairdocs.org/sdr/9510049911.md): Cables · binding · Jun 17, 1995 · N961N · Doug DC931 · Landing Gear Door Retract Section
  > STRONG VIBRATION AND A LOUD NOISE FROM THE NOSE GEAR AREA, AFTER TAKEOFF. FLIGHT RETURNED TO SDF AND LANDED WITHOUT INCIDENT. FOUND BOTH NOSE GEAR DOOR CABLES AND BINDING AT PIVOT POINTS, CAUSING CABLE TO CATCH ON DOOR LINK AND BINDING DOORS. ADJUSTED LEFT
- [SDR 9506949911](https://openairdocs.org/sdr/9506949911.md): Door Frame · cracked · Apr 26, 1995 · N961N · Doug DC931 · Fuselage Miscellaneous Structure
  > DURING PERIODIC CHECK, FOUND CRACK IN THE RIGHT MAIN LANDING GEAR DOOR CUTOUT FRAME AT THE MICROSWITCH. REPAIRED FRAME PER EA 99-094843.

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE n_number = 'N961N' AND deregistration_id = 'N961N-2008-08-04'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/deregistered/N961N-2008-08-04/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.