# Service difficulty reports: JASC 3330

A list on [JASC 3330](https://openairdocs.org/jasc/3330.md).

Reports filed under 3330 · Cargo Compartment Lighting, newest first.

Page 1 of 2 · 64 reports

- [SDR WX0A2025071632501](https://openairdocs.org/sdr/WX0A2025071632501.md): Light · inoperative · Jul 15, 2025 · N817NV · Boeing 7378200
  > (AIRCRAFT NOT GROUNDED) RH AFT OVERWING EXIT LIGHT INOP. / REMOVED AND REPLACED RH AFT OVERWING EXIT LIGHT OPS CHECK REF AMM 33-21-00-960-803."
- [SDR FDEA202506191012](https://openairdocs.org/sdr/FDEA202506191012.md): Switch · failed · Jun 19, 2025 · N293FE · Boeing 7673S2F
  > ONLOAD TEAM REPORTS FWD LOWER CARGO LIGHTS INOP, CARGO HANDLING SYSTEM WORKS FINE PULLED AND COLLERED FWD LOWER LOBE C/B S10 ON P-34 PANEL REMOVED FWD CARGO DOOR CONTROL PANEL P-43 AND FOUND SWITCH S513 WIRES BURNED/DAMAGED. INSPECTED DAMAGE TO S513 AND A
- [SDR CALA2025060905359](https://openairdocs.org/sdr/CALA2025060905359.md): Light · damaged · Jun 5, 2025 · N69839 · Boeing 737924ER
  > EMERGENCY PATH LIGHT NEAR 1B/CLOSET BROKEN PER FA OPS CHECKED EMERAGNCY LIGHT. LIGHT OPERATES NORMALLY. FOUND THE LIGHT PLASTIC LENS MESSING. INSTALLED NEW OME OK TO CONTINUE
- [SDR CALA2024061001743](https://openairdocs.org/sdr/CALA2024061001743.md): Battery · no test · Jun 7, 2024 · N787UA · Boeing 777222
  > R2 DOOR EMERGENCY LIGHT BATTERY TEST FAILED. BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06.
- [SDR CALA2023110603288](https://openairdocs.org/sdr/CALA2023110603288.md): Epsu · inoperative · Nov 3, 2023 · N410UA · Airbus A320232
  > EPSU INTERNAL AFT L MESSAGE IS DISPLAYED AFTER EMERGENCY LIGHT TEST. FOLLOWED TSM 33-51-00-810-807-A, FOUND AFT LEFT EPSU AT FAULT. REMOVED AND REPLACED EPSU REF AMM 33-51-38. OPS CHECK GOOD. PARTS USED: 31-3350-9-9001,QTY:1 ROTABLE PARTS CHANGE WAS INDICATE
- [SDR FDEA202206291618](https://openairdocs.org/sdr/FDEA202206291618.md): Lamp · inoperative · Jun 29, 2022 · N913FD · Boeing 757200
  > FOUND ARM/DISARM LIGHT SWITCH BULB INOP. RELAMPED ARM/DISARM LIGHT SWITCH FROM P82 PANEL AS PER AMM 33-30-00-0. OPN CHECK GOOD. OK FOR FURTHER SERVICE.
- [SDR YENA2022042800419](https://openairdocs.org/sdr/YENA2022042800419.md): Lgciu · failed · Apr 19, 2022 · N508JL · Airbus A320232
  > FLT# 252, RSW-HPN. (AIRCRAFT DIVERTED TO JFK). 'LG - LGCIU 1 FAULT; REMOVED AND REPLACED LGCIU #1 IAW AMM 32-31-71. OPS AND BITE CHECK GOOD. A/C OK FOR SERVICE.'
- [SDR SWAA2022040790959](https://openairdocs.org/sdr/SWAA2022040790959.md): Fuse · inoperative · Apr 4, 2022 · N417WN · Boeing 7377H4
  > LEFT OVERWING EXIT SIDEWALL LIGHT INOP. / [01] REPLACED LEFT OVERWING EXIT SIDEWALL LIGHT FUSE; SATISFACTORY OP CK REF AMM 33-21-00.
- [SDR DALA2021120207442](https://openairdocs.org/sdr/DALA2021120207442.md): None · none · Nov 29, 2021 · N513DZ · Airbus A350941
  > SHIP 3513 - AFT CARGO LIGHT PANEL DAMAGE. CORRECTIVE ACTION: RECEIVED FINAL ERA 595687-14 REV ORIG. COMPARED TO PRI 595687-14 REV ORIG. REV 1, AND REV 2. NO DISCREPANCIES NOTED. (2034649)
- [SDR FDEA202111192922](https://openairdocs.org/sdr/FDEA202111192922.md): None · none · Nov 19, 2021 · N159FE · Boeing 767300
  > WAS ALERTED BY RAMP PERSONAL OF SMOKE COMING FROM FWD CARGO DOOR CONTROL PANEL WHEN DOOR WAS OPENED ELECTRICALLY. SUBMITTED IN ERROR. PLEASE REFERENCE SDR# 21-2903. SUBMITTED IN ERROR. PLEASE REFERENCE SDR# 21-2903.
- [SDR REXA2021080600550](https://openairdocs.org/sdr/REXA2021080600550.md): Bracket · cracked · Jul 23, 2021 · N183GJ · Cndair CL6002D24
  > THE CENTER CARGO COMPARTMENT LIGHT FIXTURE HAS A CRACKED BRACKET - REMOVED AND REPLACED CENTER CARGO COMPARTMENT LIGHT FIXTURE BRACKET IAW CRJ 900 SRM 51-41-02.
- [SDR QXEA2021071600364](https://openairdocs.org/sdr/QXEA2021071600364.md): Light · loose · Jul 15, 2021 · N402QX · Bombdr DHC8402
  > ILLUMINATION STRIP IN FORWARD ENTRY IN FRONT OF FORWARD BAGGAGE COMPARTMENT IS LOOSE AND SNAGS ON INTERNAL BAGGAGE DOOR. REMOVED FROM SERVICE. RE-SECURED ILLUMINATION STRIP IN FRONT OF FWD GALLEY/FWD BAGGAGE DOOR. STRIP IS SECURE IN PLACE AND FWD BAGGAGE DOOR
- [SDR DALA2021060703106](https://openairdocs.org/sdr/DALA2021060703106.md): Plate · corroded · Jun 2, 2021 · N685DA · Boeing 757232
  > SHIP 685 CORROSION ON LIGHT ASSY PLATE LOWER AREA AT AFT CARGO DOOR. CORRECTIVE ACTION: SUMMARY OF NRC 254: LIGHT ASSY PLATE LOWER AREA AT AFT CARGO DOOR WAS REPLACED PER B757-200 SRM. (1827832)
- [SDR CALA2021051400658](https://openairdocs.org/sdr/CALA2021051400658.md): Light · inoperative · May 14, 2021 · N34137 · Boeing 757224
  > L/H AFT OVERWING EXIT LIGHT INOP, SPT, L/P 7000825 RE-LAMP L/H AFT OVERWING EXIT LIGHT AND OPS CHECK GOOD IAW B757 AMM 33-51-06. PART NAME LAMP LOCATION L/H AFT OVERWNG MFG P/N GE 767 MFG S/N NSN MFG GE. DATA WAS TRANSCRIBED FROM N/R 7000825, W ORK ACCOMPLISHE
- [SDR AALA202104019028](https://openairdocs.org/sdr/AALA202104019028.md): Ballast · failed · Mar 30, 2021 · N919US · Airbus A321231
  > AIRCRAFT WAS GROUNDED: SMOKE SMELLED BUT NOT OBSERVED IN THE AFT CABIN DISSIPATED AFTER5 MINUTES NO OTHER INDICATIONS. FOUND A BURNED AFT BALLAST IN THE AFT CARGO COMPARTMENT. REPLACED BALLAST AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-34-11.
- [SDR AALA202103319005](https://openairdocs.org/sdr/AALA202103319005.md): Ballast · burned · Mar 30, 2021 · N919US · Airbus A321231
  > AIRCRAFT WAS GROUNDED: SMOKE SMELLED BUT NOT OBSERVED IN THE AFT CABIN. DISSIPATED AFTER 5 MINUTES AND NO OTHER INDICATIONS OF FIRE OR SMOKE. FOUND A BURNED AFT BALLAST IN THE AFT CARGO COMPARTMENT. REMOVED AND REPLACED BALLAST IAW AMM 33-34-11.
- [SDR DALA2021032901834](https://openairdocs.org/sdr/DALA2021032901834.md): Lens · missing · Mar 29, 2021 · N175DN · Boeing 767332
  > SHIP 175 - DURING SERVICE CHECK MAINTENANCE FOUND CEILING LIGHT LENSE ABOVE 5A MISSING AND INSTALLED NEW LENSE. SYSTEM OPERATION IS NORMAL.
- [SDR FDEA202009152221](https://openairdocs.org/sdr/FDEA202009152221.md): Housing · cracked · Sep 15, 2020 · N127FE · Boeing 7673S2F
  > AFT CARGO DOOR UPPER AFT CARGO LIGHT GOUGED AND CRACKED. REPAIRED AFT CARGO DOOR UPPER AFT CARGO LIGHT, IAW B767-AMM 25-00-00-8.
- [SDR FDEA202009152220](https://openairdocs.org/sdr/FDEA202009152220.md): Housing · cracked · Sep 15, 2020 · N127FE · Boeing 7673S2F
  > AFT CARGO DOOR UPPER FWD CARGO LIGHT GOUGED AND CRACKED. REPAIRED AFT CARGO DOOR UPPER FWD CARGO LIGHT, IAW B767-AMM 25-00-00-8.
- [SDR 2020F00265](https://openairdocs.org/sdr/2020F00265.md): Light · overheated · Jan 29, 2020 · N700MV · Gulstm GIV
  > BAGGAGE OVERHEAD DOME LIGHT CAUSED A MELTING MARK ON PLASTIC BAGGAGE THAT CONTACTED DOME LIGHT LENS. INITIAL CORRECTIVE ACTION WAS TO RELEASE COMPANY WIDE SAFETY NEWSLETTER TO ADVISE OF THIS EVENT AND TO AVOID PLACING ITEMS HIGH ENOUGH TO CONTACT DOME LIGHT LE
- [SDR ABXA20160818133](https://openairdocs.org/sdr/ABXA20160818133.md): Transformer · defective · Aug 18, 2016 · N362CM · Boeing 767338
  > 5 OUT OF 6 FORWARD LOWER CARGO DOOR SILL AREA LIGHTS DO NOT ILLUMINATE DURING CARGO LOADING OPERATIONS. AT THE FORWARD UPPER SILL LIGHT POSITION, SMOKE WAS FOUND AT A BURNED WIRE. THE FORWARD UPPER LIGHT ASSEMBLY WAS REMOVED AND FOUND 4 WIRES BURNED, 2 SHORTE
- [SDR QXEA2015111100590](https://openairdocs.org/sdr/QXEA2015111100590.md): Bulb · wrong part · Nov 11, 2015 · N423QX · Bombdr DHC8402
  > ELECTRICAL ODOR IN THE AFT CARGO COMPARTMENT ON THE GROUND. FOUND LIGHT IN COMPARTMENT TO HAVE HIGH WATTAGE NR 1683 BULB INSTALLED. REPLACED WITH LOW WATTAGE NR 305. RETURNED TO SERVICE.
- [SDR QXEA2015081900434](https://openairdocs.org/sdr/QXEA2015081900434.md): Light · malfunctioned · Aug 19, 2015 · N439QX · Bombdr DHC8402
  > F/A REPORTS BURNING ODOR IN AFT GALLEY AREA. F/A SMELL VERIFIED WITH AFT PAX DOOR CLOSED, RECIRCULATING FAN BOTH ON & OFF, BLEED AIR BOTH ON & OFF. ODOR APPEARED TO BE COMING FROM AFT MOST VENTED CEILING PANEL IN AFT GALLEY. UPON FURTHER INVESTIGATING FOUND
- [SDR QXEA2015081900433](https://openairdocs.org/sdr/QXEA2015081900433.md): Light · arced · Aug 19, 2015 · N439QX · Bombdr DHC8402
  > F/A'S REPORT A SLIGHT ELECTRICAL ODOR IN THE AFT MAIN CABIN AROUND ROW 18 AND AFT GALLEY AREA. C/W TROUBLESHOOTING ELECTRICAL ODOR IN THE ACFT REF MCN 62172-01, STEP 1A. FOUND AFT CARGO AFT LIGHT ASSY ARCING WITHIN ASSY. R & R AFT CARGO AFT LIGHT ASSY, REF
- [SDR QXEA2015042900224](https://openairdocs.org/sdr/QXEA2015042900224.md): Bulb · wrong part · Apr 29, 2015 · N442QX · Bombdr DHC8402
  > ODOR REPORTED IN THE AFT CARGO COMPARTMENT. FOUND THE AFT CARGO COMPARTMENT FORWARD LIGHT VERY HOT. FOUND FORWARD LIGHT ASSY IN AFT CARGO COMPARTMENT HAD HIGH WATTAGE LIGHT BULB. R & R LIGHT ASSY AND BULB IAW AMM, TASK 33-31-00-000-801 AND 33-31-01-400-801
- [SDR QXEA2014100600836](https://openairdocs.org/sdr/QXEA2014100600836.md): Light · odor · Oct 6, 2014 · N410QX · Bombdr DHC8402
  > SULFUR ODOR REPORTED FROM AFT CARGO FWD LIGHT REPORTED BY GROUND CREW AND CONFIRMED BY CAPTAIN. THERE WAS ALSO HEAT BEING RELEASED FROM THE LIGHT AND ELECTRICAL ODOR. C/W AIR CONTAMINATION CHECKLIST FORM M-744-3600, 10-6-14. REMOVED FWD AND AFT CARGO LIGHTS
- [SDR QXEA2014092300801](https://openairdocs.org/sdr/QXEA2014092300801.md): Light · odor · Sep 23, 2014 · N418QX · Bombdr DHC8402
  > GROUND CREW REPORTED STRONG SULPHUR ODOR IN AFT CARGO BAY. FOUND TO BE COMING FROM AFT CARGO LIGHT. R & R LIGHT IAW AMM TASK 33-31-01-000-801, & 33-31-01-400-801. OPS CHECKED GOOD.
- [SDR QXEA2014091200777](https://openairdocs.org/sdr/QXEA2014091200777.md): Light · odor · Sep 12, 2014 · N443QX · Bombdr DHC8402
  > ELECTRICAL ODOR IN THE AFT GALLEY AREA. COMPLIED WITH AIR CONTAMINATION CHECKLIST IAW M-744. FOUND SOURCE OF ODOR TO BE FOUND AFT CARGP BAY FWD O/H LIGHT. R & R CARGO LIGHT ASSY IAW MM TASK 33-31-01-000-801 + 33-31-01-400-801. OPS CHECK GOOD. ODOR DID NOT R
- [SDR QXEA2014091100776](https://openairdocs.org/sdr/QXEA2014091100776.md): Light · malfunctioned · Sep 11, 2014 · N413QX · Bombdr DHC8402
  > F/A'S REPORT UNUSUAL ODOR IN THE AFT GALLEY, STRONGEST ON LT SIDE NEAR AFT PAX DOOR. BOTH AFT DOORS WERE CLOSED AND AFT CARGO DOOR CLOSED WHEN ODOR WAS STRONGEST. APU WAS RUNNING, PROVIDING ELECTRICAL AND BLEED AIR AT THE TIME. ODOR DID NOT SEEM TO BE COMING
- [SDR QXEA2014090900775](https://openairdocs.org/sdr/QXEA2014090900775.md): Light · damaged · Sep 9, 2014 · N449QX · Bombdr DHC8402
  > CAPTAIN REPORTED A BURNING ODOR IN THE AFT GALLEY AREA. FOUND ODOR IN AFT CARGO BAY FWD LIGHT ASSY. REPLACED LIGHT SOCKET ASSY, ODOR DISSIPATED WITH POWER ON AS FOUND DURING REPORT. NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.
- [SDR QXEA2014090900770](https://openairdocs.org/sdr/QXEA2014090900770.md): Light · odor · Sep 9, 2014 · N449QX · Bombdr DHC8402
  > CAPTAIN REPORTED A BURNING ODOR IN AFT GALLEY. FOUND ODOR IN AFT CARGO BAY FWD LIGHT ASSY. REPLACED LIGHT SOCKET ASSY, ODOR DISSAPATED WITH POWER ON AS FOUND DURING REPORT. NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.
- [SDR QXEA2014090100727](https://openairdocs.org/sdr/QXEA2014090100727.md): Light · odor · Sep 1, 2014 · N436QX · Bombdr DHC8402
  > AFT F/A REPORTED FAINT ODOR OF SMOKE IN AFT GALLEY. RAMP INSPECTED AFT CARGO AREA AND REPORTED A SIMILAR ODOR. NO VISIBLE SIGNS OF SMOKE. FOLLOWED MCN 62172-01, ISSUE NR 2 TROUBLESHOOTING COMMON ODORS IN ACFT. PERFORMED GVI ON AFT CARGO BAY. FOUND FWD LI
- [SDR FDEA201301160111](https://openairdocs.org/sdr/FDEA201301160111.md): Socket · burned · Jan 16, 2013 · N372FE · Doug MD1010F
  > LOAD CREW REPORTED BURNING ODOR. FOUND AFT OVERHEAD LIGHT LAMP HOLDER BURNED. REPLACED LIGHT ASSY IAW MM 33-31-01-2.
- [SDR QXEA2012110801364](https://openairdocs.org/sdr/QXEA2012110801364.md): Light · burned · Nov 8, 2012 · N407QX · Bombdr DHC8402
  > UNUSUAL ODOR WHEN ENTERING ACFT. FOUND BOTH AFT CARGO LIGHT ASSY BURNED. TERMINATED WIRES, PROPER POLARITY WAS OBSERVED, BOTH ASSEMBLIES WERE RELACED. OPS CHECKED NORMAL, NO UNUSUAL ODOR EXISTS. RETURNED TO SERVICE.
- [SDR UALA2012110506316](https://openairdocs.org/sdr/UALA2012110506316.md): Lamp · inoperative · Nov 4, 2012 · N222UA · Boeing 777222
  > FWD LIGHTS IN AFT CARGO CMPT ABOVE LLAR ARE INOP. FOUND 4 EA LIGHTS OUT DURING COMPLETION OF EG7521 FCD 3330-01031 INOPED PER MEL. REPLACED LAMPS, OPS GOOD.
- [SDR QXEA2012102501348](https://openairdocs.org/sdr/QXEA2012102501348.md): Socket · burned out · Oct 25, 2012 · N411QX · Bombdr DHC8402
  > CIRCUIT BREAKER LEFT ESS WRB & BAGGAGE LIGHT TRIPPED. REMOVED AFT BAGGAGE COMPARTMENT AFT LAMP ASSY AND INSPECTED, FOUND LAMP SOCKET ASSY BURNED OUT, REPLACED LAMP ASSY. FOUND FWD WAS ALREADY OPERATIVE AFTER RESETTING CIRCUIT BREAKER. OPS CHECKED GOOD. REF
- [SDR QXEA2012081000788](https://openairdocs.org/sdr/QXEA2012081000788.md): Light · odor · Aug 10, 2012 · N446QX · Bombdr DHC8402
  > F/A (B) REPORTS AN ELECTRICAL ODOR IN THE AFT GALLEY AFTER BOARDING PASSANGERS COMPLETE. AFT PAX DOOR CLOSED AND LOCKED. FOUND SOURCE TO BE THE AFT CARGO COMPARTMENT LIGHTS.
- [SDR QXEA2012072500739](https://openairdocs.org/sdr/QXEA2012072500739.md): Light · overheated · Jul 25, 2012 · N438QX · Bombdr DHC8402
  > F/A REPORTS ELECTRICAL BURNING ODOR IN AFT CABIN AREA. FOUND TO BE LIGHTS IN AFT CARGO COMPARTMENT. REPLACED BOTH AFT CARGO BAY LIGHT ASSYS & TERMINAL LUGS. OPS CHECKED GOOD. RETURNED TO SERVICE.
- [SDR QXEA2011101000982](https://openairdocs.org/sdr/QXEA2011101000982.md): Light · damaged · Oct 4, 2011 · N430QX · Bombdr DHC8402
  > POSSIBLY ELECTRICAL ODOR EMANATING FROM REAR OF ACFT. INSPECTED CARGO PIT FOUND ODOR TO BE CENTERED AROUND THE FWD LAMP ASSY. BEGAN REMOVAL OF PANEL 251CZ REMOVED ENOUGH OF THE PANEL TO GRANT ACCESS FOR FURTHER INSPECTION REQUIRING THE REMOVAL OF THE AFT CAR
- [SDR UALA2011061002863](https://openairdocs.org/sdr/UALA2011061002863.md): Light · faulty · Jun 9, 2011 · N660UA · Boeing 767322
  > FWD CARGO PIT CARGO LOADING CONTROL PANEL, FOUND FLOODLIGHT ASSY TAPED OVER. (NO LENS COVER, & NO BULB) ASSY LOOSE. DURING REPLACEMENT, CTR POST SHORTED & PIT LIGHTS OUT. NEED NEW LT ASSY (PCN=563-0377) ITEM 275, USING BULB 1495X. REPLACED LIGHT ASSY. TE
- [SDR SWIA200922576](https://openairdocs.org/sdr/SWIA200922576.md): Switch · out of rig · Sep 12, 2009 · N291SW · Emb EMB120ER
  > CARGO BIN LIGHT BURNED SUITCASE. (FLT 7788) RE-RIGGED CARGO DOOR LIGHT SWITCH ACTUATING ASSEMBLY.
- [SDR DL757091406](https://openairdocs.org/sdr/DL757091406.md): Switch · failed · Aug 27, 2009 · N681DA · Boeing 757232
  > RAMP REPORTS AFT CARGO LIGHT SWITCH IS SMOKING. FOUND S429 AFT CARGO DOOR SWITCH ON FIRE. PULLED EXTERNAL POWER CORD. FIRE EXTINGUISHED. INSPECTED WIRING AND SURROUNDING AREA FOR DAMAGE. NONE NOTED PAST SWITCH. REPLACED S429 DOOR SWITCH ASSY AND TERMINAL
- [SDR A6WA200940450](https://openairdocs.org/sdr/A6WA200940450.md): Battery Pack · failed · Jul 28, 2009 · N415AW · Cndair CL6002B19
  > STRONG BURING ODOR AT MID CABIN OVERHEAD. FOUND ODOR TO BE VERY STRONG AT CEILING PANEL 7CA. REMOVED CEILING PANE LS AND PAX SERV UNIT PANELS FROM 5AD-8AC FOR T/S. FOUND NO ODOR UNDER PSU`S REMOVED CEILING INSULATION AND VERIVIED THAT NO CHAFED WIRES ON CEI
- [SDR CA080115004](https://openairdocs.org/sdr/CA080115004.md): Light · shorted · Jan 12, 2008 · Dhav DHC8102
  > (CAN) DURING FLIGHT, THE CREW REPORTED (TO MOC) THAT THEY HAD THE (SMOKE) WARNING ILLUMINATED. THEY WERE TOLD TO DO A TURNBACK AND RETURN TO AIRPORT WHERE MAINT STAFF MET THE AIRCRAFT. DURING THE INVESTIGATION, MAINT PERSONNEL FOUND THE SIDEWALL BAGGAGE DOOR
- [SDR 06FDEA0317](https://openairdocs.org/sdr/06FDEA0317.md): Housing · cracked · Jan 23, 2006 · N488FE · Boeing 727200
  > FWD CARGO COMPT CEILING LIGHT HOUSING CRACKED IN SEVERAL PLACES AT BS 608 LBL 32 WL 202. REMOVED AND REPLACED FWD CARGO COMPT. CEILING LIGHT HOUSING AT BS 608 LBL 32 WL 202. IAW IPC 33-30-00-02.
- [SDR SWIA200515099](https://openairdocs.org/sdr/SWIA200515099.md): Ballast · smoke · May 24, 2005 · N569SW · Emb EMB120ER
  > ON TAXI OUT, SMELLED SMOKE IN CABIN/COCKPIT THEN RECEIVED BAGGAGE COMPARTMENT FIRE/SMOKE INDICATION. REPLACED LIGHT BALLASTS AS NEEDED. OPERATIONAL CHECK GOOD.
- [SDR SIMA200430802](https://openairdocs.org/sdr/SIMA200430802.md): Module · inoperative · Oct 31, 2004 · N728AE · Emb EMB135LR
  > CREW REPORTED A SMOKE SMELL IN COCKPIT AND GALLEY AREA, AIRCRAFT WAS DIVERTED AND SAFELY WITH NO INCIDENTS. MAINTENANCE REMOVED AND REPLACED THE SIDE WALL LIGHT CONTROL MODULE IAW MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.
- [SDR GTIA030954](https://openairdocs.org/sdr/GTIA030954.md): Light · inoperative · Nov 27, 2003 · N827NK · Doug DC983
  > MCO - EMERGENCY EXIT IDENTIFIER LIGHT FOR AFT CABIN DOOR INOPERATIVE. REPAIRED WIRES FOR EMERGENCY EXIT IDENTIFIER AT AFT CABIN DOORS, OPS CHECK OK. (M)
- [SDR KPVA200244](https://openairdocs.org/sdr/KPVA200244.md): Light · inoperative · Dec 29, 2002 · N808WP · Dhav DHC8103
  > NR 2 BAGGAGE COMPARTMENT SMOKE DETECTOR, INOPERATIVE. NO TEST. SYSTEM VERIFIED INOPERATIVE AND DEFFERED IAW MEL. ON 12-30-02 MAINTENANCE CLEARED MEL DEFFERAL BY REMOVING AND REPLACING THE NR 2 BAGGAGE SMOKE DETECTOR LAMP. SYSTEM OPS CHECKED IAW MM.
- [SDR DL757020369](https://openairdocs.org/sdr/DL757020369.md): Switch · faulty · Mar 25, 2002 · N632DL · Boeing 757232
  > ON L/O CHECK, AFT CARGO LIGHT SWITCH CAUGHT ON FIRE. REPLACED SWITCH.

Next page: https://openairdocs.org/jasc/3330/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE jasc_code = '3330'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/jasc/3330/reports

---