- [SDR AALA202610129314](https://openairdocs.org/sdr/AALA202610129314.md): Valve · inoperative · Oct 8, 2026 · N998NN · Boeing 737823
  > AIRCRAFT WAS NOT GROUNDED: -- NO EMERGENCY DECLARED AND AIRCRAFT WAS NOT OVERWEIGHT FOR LANDING -- NO RUNNING WATER ON ALL 3 LAVATORIES SINKS AND RINSING WATER ON TOILETS. FILL/OVERFLOW VALVE FOUND PARTIALLY OPEN, VALVE FULLY CLOSED AND WATER TANK FULL, OPS C
- [SDR R61A2026100100291](https://openairdocs.org/sdr/R61A2026100100291.md): Anti-Ice System · faulted · Sep 28, 2026 · N861RW · Emb ERJ170100SE
  > ANTI-ICE WING FAIL IN FLIGHT. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. PERFORMED A-I WING FAIL RESET, FAULT CLEARED.
- [SDR SWAA2026092854306](https://openairdocs.org/sdr/SWAA2026092854306.md): Filter · odor · Sep 23, 2026 · N9015R · Boeing 7378
  > FWD GALLEY WATER SMELLS MUSTY. REMOVED AND REPLACED FWD GALLEY WATER FILTER PER AMM 38-10-01. NO FOUL ODOR
- [SDR CALA2026092119556](https://openairdocs.org/sdr/CALA2026092119556.md): Potable Water · contaminated · Sep 19, 2026 · N17574 · Boeing 7379
  > WATER FROM REAR COFFEE MACHINE SMELLS AND TASTES BAD. DRAINED AND REFILLED POTABLE WATER SYSTEM IN REF TO AMM 12-14-00. OPS CHECK BOTH REAR COFFEE MAKERS IN THE REAR OF THE AIRCRAFT IN REF TO AMM 25-32-01. THE WATER NO LONGER SMELLS.
- [SDR CALA2026092119555](https://openairdocs.org/sdr/CALA2026092119555.md): Potable Water · contaminated · Sep 18, 2026 · N37555 · Boeing 7379
  > BAD ODOR AND TASTE COMING FROM POTABLE WATER. DRAINED POTABLE WATER TANK AND REFILLED TANK, ALSO PURGED ALL FACETS AND COFFEE MAKERS, ODOR AND SMELL IS GONE. REF FIM 38-10 TASK 803.
- [SDR CALA2026080518333](https://openairdocs.org/sdr/CALA2026080518333.md): Potable Water · low pressure · Aug 4, 2026 · N37313 · Boeing 7378
  > FA REPORTED NO WATER PRESSURE WHEN REACHED CRUISE, ARRIVED, CHECKED PORTABLE WATER PANEL LATCHES WERE CLOSED, VERIFIED THE FILL VALVE AND THE DRAIN VALVE WERE IN THE CLOSED POSITION (NORMAL POSITION), WATER TANK WAS FULL ON ARRIVAL. HAD PORTABLE WATER SERVICE
- [SDR CALA2026072017897](https://openairdocs.org/sdr/CALA2026072017897.md): Water Line · leaking · Jul 17, 2026 · N47517 · Boeing 7379
  > AFT RT LAV LEAKING AND SMELLS BAD INBOUND CREW REPORTS EVIDENCE OF WATER LEAK AROUND PAPER TOWEL HOLDER UNDER AFT RT LAV SINK. INSPECTED CABINET UNDER SINK FOUND NO STANDING WATER AND NO ACTIVE LEAK.
- [SDR DALA2026071504165](https://openairdocs.org/sdr/DALA2026071504165.md): Water Heater · odor · Jul 12, 2026 · N311DU · Airbus BD5001A11
  > DIVERTED TO YVR DUE TO ELECTRICAL ODOR IN THE AFT LAVATORIES. PLACED AFT LEFT LAVATORY WATER HEATER ON MEL; SAME REPLACED. (LP# 8740810, 8740812, 8740813; AIRCRAFT WAS GROUNDED)
- [SDR 2026FA0000559](https://openairdocs.org/sdr/2026FA0000559.md): Potable Water · inoperative · Jun 30, 2026 · N965AV · Airbus A320251N
  > NO PORTABLE WATER DURING FLIGHT. IAW TSM 38-12-00-810-814-A REV.77 PERFORMED OPERATIONAL TEST OF PORTABLE WATER DRAIN SYSTEM AS PER AMM 38-14-00-710-001-A REV.77 DATE 01-MAY 2026 AND ALL OK
- [SDR AALA202606150439](https://openairdocs.org/sdr/AALA202606150439.md): Potable Water · empty · Jun 13, 2026 · N990NN · Boeing 737823
  > AIRCRAFT WAS GROUNDED: FA NOTIFIED FLIGHT DECK THEY HAD ZERO POTABLE WATER UPON REACHING CRUISE. I HAD THEM TRY TO FLUSH TOILETS AND USE SINK, STILL ZERO WATER AVAILABLE. ALSO ZERO WATER AVAILABLE IN EITHER GALLEY. DECESION MADE TO RETURN TO CLT EMERGENCY DECL
- [SDR CALA2026052816604](https://openairdocs.org/sdr/CALA2026052816604.md): Pressure System · inoperative · May 24, 2026 · N785UA · Boeing 777222
  > NO WATER PRESSURE FOR ENTIRE AIRCRAFT AFTER TAKEOFF.
- [SDR CALA2026051516279](https://openairdocs.org/sdr/CALA2026051516279.md): Potable Water · not opened · May 14, 2026 · N47345 · Boeing 7378
  > NO WATER PAX IN ANY LAV OR FAUCET FOUND HANDLE AT THE WATER SERVICING PANEL, NOT IN THE FULLY CLOSED DETENT POSITION PLEASE HANDLE IN THE FULLY CLOSED DETENT POSITION TECH FOUND WATER SERVICING VALVE IN WRONG POSITION UPDATE FOR SDR PURPOSES BECAUSE AIRCRAFT W
- [SDR DALA2026050802921](https://openairdocs.org/sdr/DALA2026050802921.md): Water Heater · failed · May 8, 2026 · N822NW · Airbus A330302
  > LAVS AT 3 INBD ELECTRICAL ODOR. REPLACED HOT WATER HEATER PER A330 AMM 38-14. OK FOR SERVICE. (1583286) AIRCRAFT WAS GROUNDED.
- [SDR SCNA20260506187](https://openairdocs.org/sdr/SCNA20260506187.md): Potable Water · contaminated · May 3, 2026 · N828SY · Boeing 7378F2
  > WATER HAS A TOXIC ODOR, COFFEE/ HOT WATER SMELLS LIKE CHLORINE AND HAS A CHECMICAL TASTE AND MAKES EYES BURN. SERVICED POTABLE WATER SYSTEM IAW AMM 38-42-00-800-802. NO ODOR FOUND. FLUSHED POTABLE WATER SYSTEM AND RESERVICED PER AMM 38-10-00-860-005.
- [SDR SCNA20260504178](https://openairdocs.org/sdr/SCNA20260504178.md): Potable Water · contaminated · May 3, 2026 · N828SY · Boeing 7378F2
  > WATER HAS A TOXIC SMELL. COFFEE/ HOT WATER SMELLS LIKE CHLORINE AND HAS A CHECMICAL TASTE AND MAKES EYES BURN. SERVICED POTABLE WATER SYSTEMPER AMM 38-42-00-800-802.NO SMELLED FOUND. FLUSHED POTABLE WATER SYSTEM AND RESERVICED PER AMM 38-10-00-860-005.
- [SDR CALA2026050515979](https://openairdocs.org/sdr/CALA2026050515979.md): Potable Water · no discrepancy · May 1, 2026 · N69818 · Boeing 737924ER
  > POTABLE WATER HAS A CHEMICAL TASTE. WHEN JUST WATER IS POURED IT HAS A CHLORINE LIKE ODOR. OPERATIONS DRAINED AND SERVICED POTABLE WATER SYSTEM. PERFORMED INITIAL EVALUATION PER FIM 38-10 TASK 810. NO BAD SMELL OR WATER QUALITY ISSUE.
- [SDR DALA2026050402792](https://openairdocs.org/sdr/DALA2026050402792.md): Water Heater · failed · May 1, 2026 · N531DA · Airbus A321271NX
  > DIV - TO OMA DUE TO ELECTRICAL SMELL IN THE AFT GALLEY. SUSPECTED AFT LAV WATER HEATER INOPERATIVE, PLACED ON MEL. LATER MEL CLEARED WITH AN OPS CHECK. (LP 8369650 - AIRCRAFT WAS GROUNDED)
- [SDR AALA202604289909](https://openairdocs.org/sdr/AALA202604289909.md): Water Heater · failed · Apr 27, 2026 · N924NN · Boeing 737823
  > AIRCRAFT WAS GROUNDED: LAVATORY-D SMOKE LIGHT ILLUMINATED ON OVERHEAD PANEL. FLIGHT ATTENDANT CONFIRMED SMOKE PRESENCE IN LAVATORY-D THAT QUICKLY DISSIPATED UPON OPENING THE DOOR. ELECTRICAL ODOR REMAINED, BUT NO FURTHER EVIDENCE OF SMOKE OR FIRE. REMOVE AND R
- [SDR CALA2026042415684](https://openairdocs.org/sdr/CALA2026042415684.md): Valve · closed · Apr 21, 2026 · N785UA · Boeing 777222
  > NO WATER FLOW ON AIRCRAFT SPIGOTS AND LAV OVERFLOW VALVE CONFIRMED TO BE IN CLOSED POSITION. CABLE DISCONNETED AND SECURED. ALL FOUCETS WITH WATER AND SYSTEM PRESSURIZED PROPERLY. NO LEAKS WERE FOUND IAW AMM 38-11-03
- [SDR CALA2026042315656](https://openairdocs.org/sdr/CALA2026042315656.md): Drain Mast · missing · Apr 20, 2026 · N79402 · Boeing 737924
  > UPON ARRIVING TO THE GATE RAMP REPORTED THERE WAS METAL HANGING FROM THE A/C WHEN MYSELF AND TECHS WENT OUT WE REALIZED IT WAS THE FWD DRAIN MAST THAT WAS MISSING. ADDED PHOTOS REF L/P 8622727 FOR MX ACTION MAST, DRAIN, WA OFF 29-3831-9-9001 3818 ON 0000 RAM
- [SDR SWAA2026040786115](https://openairdocs.org/sdr/SWAA2026040786115.md): Water Heater · failed · Apr 2, 2026 · N8650F · Boeing 7378H4
  > FA REPORTED ELECTRICAL BURNING SMELL COMING FROM AFT RIGHT LAV<[01] PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION REF AMM 05-51-56. FOUND RH AFT LAV WATER HEATER TO BE THE SOURCE OF THE SMELL. SEE NEXT PAGE FOR MEL LP # 3054862.
- [SDR SWAA2026031679516](https://openairdocs.org/sdr/SWAA2026031679516.md): Filter · odor · Mar 13, 2026 · N8670A · Boeing 7378H4
  > WATER SMELLS OF CHEMICALS. DRAIN POTABLE WATER TANK. R & R GALLEY FILTERS. SERVICED POTABLE WATER PER AMM 38-11-99.
- [SDR CALA2026031314542](https://openairdocs.org/sdr/CALA2026031314542.md): Water Heater · overheated · Mar 10, 2026 · N39416 · Boeing 737924ER
  > PER FA SMOKE ALARM LAV E WENT OFF DURING TAXI IN AND WATER HEATER VERY HOT W AMBER LIGHT ON PER INBD CAPT SALATICH NO SMOKE OR ODOR NOTICED. UPON ARRIVAL IN CABIN SMOKE DETECTOR OFF. HOT WATER HEATER CKS NORMAL FOR TEMP. ACP'ED SMOKE DETECTOR TEST AND TEST NOR
- [SDR DALA2026030301467](https://openairdocs.org/sdr/DALA2026030301467.md): Water Heater · overheated · Mar 1, 2026 · N334DN · Airbus A321213
  > SHIP 3034 - FUMES - CREW REPORTED AN ELECTRICAL SMELL DURING THE APPROACH. DONNED OXYGEN MASKS AND DECLARED AN EMERGENCY. CORRECTIVE ACTION: F/C LAVATORY WATER HEATER APPEARS TO BE OVERHEATING. DEFERRED WATER HEATER PER MEL. REPLACED FORWARD LAV WATER HEATER P
- [SDR SCNA20260216083](https://openairdocs.org/sdr/SCNA20260216083.md): Potable Water · odor · Feb 14, 2026 · N835SY · Boeing 7378KN
  > FWD GALLEY COFFEE MAKER HAS STRONG CHEMICAL ODOR, POTABLE WATER SYSTEM. DISINFECTED POTABLE WATER SYSTEM OZON REF TASK CARD 0538000002 W/O 102224 THIS CLEARS MEL 38-1-B MDDR# 136908
- [SDR SCNA20260216082](https://openairdocs.org/sdr/SCNA20260216082.md): Potable Water · odor · Feb 14, 2026 · N835SY · Boeing 7378KN
  > FA'S AND PASSENGERS NOTICE STRONG CHEMICAL SMELL COMING FRIM COFFEE/MAKER. POTABLE WATER SERVICED REF AMM 12-14-01 OK FOR SERVICE
- [SDR SWAA2026021168977](https://openairdocs.org/sdr/SWAA2026021168977.md): Potable Water · odor · Feb 8, 2026 · N910WN · Boeing 7377H4
  > F/A STATED A FOUL WATER ODOR FROM AFT GALLEY COFFEE POT. RAMP DRAINED AND REFILLED WATER TANK IAW SIP.
- [SDR CALA2026020513599](https://openairdocs.org/sdr/CALA2026020513599.md): Valve · inoperative · Feb 2, 2026 · N66051 · Boeing 767424ER
  > NO POTABLE WATER. LAV MOTOR WORKING WITH NO WATER. WATER GAUGE SHOWS FULL. RTB EWR IF AIR IS COMING OUT FROM AFT OVERFLOW DRAIN PORT AT STA 1530, REPLACE VENT OVERFLOW VALVE V130 REF AMM 38-11-05-004-001 EWRMM WORKING ITEM REF LOGPAGE 7804209. INSPECTED PRES
- [SDR CALA2026020513591](https://openairdocs.org/sdr/CALA2026020513591.md): Potable Water · leaking · Feb 2, 2026 · N4901U · Airbus A320232
  > ALL FWD DRAIN HOLES ON BOTTOM OF ACFT DRAINING WATER. WATER LINE IS INSTALLED & LEAK CHECKED. DRAIN VALVE INSTALLATION STILL NEEDS TO BE COMPLETED FROM STEP 4 A12. COMPLETED STEPS UP TO D. (1) ON DRAIN VALVE INSTALLATION IAW AMM 38-14-45-400-001-A. GALLEY LE
- [SDR CALA2026020413546](https://openairdocs.org/sdr/CALA2026020413546.md): O-Ring · damaged · Feb 2, 2026 · N34551 · Airbus A321271NX
  > FOUND WATER DRIPPING FROM BELLY DRAIN FWD OF FWD CARGO DOOR CONTROLS. WATER POOLING BELOW 80VU RACK. TRACED WATER BACK FROM BELOW 80VU RACK TO A WIGGINS FITTING FWD OF ACCLRM 12CE1 AND 12CE3. DISSASEMBLED FITTING REF AMM 20-23-38-000-001-A, FOUND FITTING COVER
- [SDR CALA2026020313534](https://openairdocs.org/sdr/CALA2026020313534.md): Potable Water · leaking · Feb 1, 2026 · N4901U · Airbus A320232
  > FOUND AFT GALLEY FLOODED WITH WATER. REMOVED ALL GALLEY CARTS FROM AFT GALLEY & COULD NOT FIND SOURCE OF LEAK. ATTEMPTED TO SERVICE POTABLE WATER, BUT ACFT WOULD NOT RECEIVE & HOLD WATER. WATER SAME OUT OF EVERY DRAIN ORFICE ON BELLEY OF ACFT. OPENED AFT C
- [SDR CALA2026013013448](https://openairdocs.org/sdr/CALA2026013013448.md): Water Line · burst · Jan 29, 2026 · N37263 · Boeing 737824
  > POTABLE WATER LINE BURST IN THE AFT CARGO BAY, AFT BULKHEAD. LINE CONNECTS TO POTABLE WATER TANK. FLOOR PANELS REMOVED IAW AMM 25-52-10-000-801, OZONE WATER CART LIQUID SPILL DETERMINED TO BE NON-HAZARDOUS IAW EC/RA 2011-01000, AFFECTED SPILL AREA BS 727+4 -
- [SDR CALA2026012613250](https://openairdocs.org/sdr/CALA2026012613250.md): Potable Water · odor · Jan 26, 2026 · N487UA · Airbus A320232
  > FA SAYS POTABLE WATER HAS STRONG FISH ODOR. PERFORMED A COMPLETE DRAIN & REFILL AS REQUIRED.
- [SDR CALA2026012313187](https://openairdocs.org/sdr/CALA2026012313187.md): Filter · faulted · Jan 20, 2026 · N17337 · Boeing 7378
  > IN FLIGHT FA REPORTED NO H2O PRESS IN LAVS AND GA LLEYS. REPEAT GRIPE. VERIFIED WATER ON AND WORKING NORMALLY ON GROUND AFTER BLEEDING SOME AIR. CREW REPORTS THAT THERE IS NO WATER IN FLIGHT. SUSPECT PRESSURE REGULATOR ON PNEUMATIC PRESSURIZATION SIDE. REPLACE
- [SDR DALA2026010400042](https://openairdocs.org/sdr/DALA2026010400042.md): Toilet · odor · Jan 3, 2026 · N329NB · Airbus A319114
  > COCKPIT SMELL LIKE URINE/LAVATORY WASTE. REMOVED, INSPECTED, REINSTALLED FIRST CLASS LAV SHROUD IAW AMM 38-32. NO DEFECTS NOTED. REMOVED FIRST CLASS LAV SHROUD FOR ACCESS PER AMM 38-32. REMOVED AND REPLACED FIRST CLASS TOILET ASSY. PER AMM 38-31. LEAKS AND OP
- [SDR SWAA2026010557656](https://openairdocs.org/sdr/SWAA2026010557656.md): Filter · odor · Jan 2, 2026 · N8882Q · Boeing 7378
  > POTABLE WATER HAS BLEACH ODOR. DRAINED AND RESERVICED POTABLE WATER. REPLACED WATER FILTERS IN FORWARD AND AFT GALLEYS PER AMM 25-31-00.
- [SDR DALA2025122909475](https://openairdocs.org/sdr/DALA2025122909475.md): Line · leaking · Dec 28, 2025 · N398DA · Boeing 737832
  > PRES/DE-THE CREW WAS UNABLE TO CONTROL PRESSURIZATION, PERFORMED AN EMERGENCY DESCENT. MAINTENANCE FOUND A WATER LEAK DIRECTLY ABOVE THE OUTFLOW VALVE RENDERING THE VALVE INOPERATIVE, REPLACED A POTABLE WATER LINE AND O-RING. WATER SYSTEM AND AUTO PRESSURIZA
- [SDR CALA2025121012008](https://openairdocs.org/sdr/CALA2025121012008.md): Linkage · faulted · Dec 6, 2025 · N791UA · Boeing 777222
  > NO WATER AVAILABLE, NO PRESSURE FOR TOILET. WASTE TANK 3 FULL. ON GROUND NO WATER AVAILABLE IN ACFT. WATER SERVICE CART CONFIRMED WATER TANKS FULL. ALL HANDLES CLOSED-NORMAL POSITION, CYCLED DURING SERVICE. STILL NO WATER, CONFIRMED WATER COMPRESSOR RUNNING
- [SDR SWAA2025120240455](https://openairdocs.org/sdr/SWAA2025120240455.md): Filter · odor · Nov 28, 2025 · N8686A · Boeing 7378H4
  > STAR AMMONIA ODOR IN THE POTABLE WATER SYSTEM. DRAINED POTABLE WATER TANK AND REPLACED AFT & FWD FILTERS PER AMM 38-10-00.
- [SDR DALA2025110408061](https://openairdocs.org/sdr/DALA2025110408061.md): Water Heater · odor · Nov 2, 2025 · N858NW · Airbus A330223
  > FA`S NOTICED BURNING SMELL IN 3L LAV. REPLACED HOT WATER HEATER. NO DIVERSION. OK FOR SERVICE. (7938112)
- [SDR CALA2025102210403](https://openairdocs.org/sdr/CALA2025102210403.md): Potable Water · contaminated · Oct 22, 2025 · N72405 · Boeing 737924
  > WATER HAS STRONG CHEMICAL SMELL AND TASTE REF FIM 38-10 TASK 810 DUMPED AND FLUSHED POTABLE WATER. SMELL IS NO LONGER. ACFT OK FOR SERVICE
- [SDR CALA2025102010276](https://openairdocs.org/sdr/CALA2025102010276.md): Potable Water · contaminated · Oct 20, 2025 · N37342 · Boeing 7378
  > WATER IN AFT GALLEY HAS METALLIC TASTE STRONG ENUOGH TO MAKE WAT ER UNSUITABLE TO BREW CFFEE POTABLE WATER DRAINED AND SERVICED MUTIPLE TIMES PER AMM 12-14-00-600-801& 802 WATER WAS RUN THROUGH GALLEY AND LAVS WATER NORMAL CLEAR IN COLOR WITH NO SMELLS
- [SDR CALA2025102010268](https://openairdocs.org/sdr/CALA2025102010268.md): Potable Water · contaminated · Oct 20, 2025 · N68801 · Boeing 737924ER
  > DRAIN AND REFILL THE POTABLE WATER SYSTEMS WITH FRESH WATER PER THE GMM COFFEE HAS CHEMICAL TAST E AND SMELL. REMADE COFF EE SAME RESULT. SUSPECT WATER TANK NEEDS FLUSH DRAIN AND REFILLED POTABLE WATER SYSTEM,
- [SDR CALA2025102010266](https://openairdocs.org/sdr/CALA2025102010266.md): Potable Water · contaminated · Oct 20, 2025 · N17401 · Boeing 7379
  > WATER TAST REPORTED TO BE VERY CHLORINE UNUSABLE FOR COFFEE DRAIN PORTABLE WATER AND FULLY SERVICE PORTABLE. NO BAD SMELL. REFERENCED FIM REFERENCE: 38-10 TASK 803
- [SDR CALA2025102010263](https://openairdocs.org/sdr/CALA2025102010263.md): Potable Water · contaminated · Oct 20, 2025 · N17301 · Boeing 7378
  > WATER TASTES BAD, FORWARD GALLEY AND LAV COMPLEX DRAINED WATER TANK, RINSED WATER TANK AND OPS CHECKS ALL FWD WATER GALLEY AND LAV COMPONENTS PER AMM FIM TASK 38-10-00-810-803. WATER DOES NOT SMELL BAD AND THE WATER QUALITY IS GOOD.
- [SDR SWAA2025101424089](https://openairdocs.org/sdr/SWAA2025101424089.md): Water Heater · smoke · Oct 13, 2025 · N8910Q · Boeing 7378
  > AFT LAV CAPTAIN SIDE HAS ELECTRICAL SMELL AND VISIBLE SMOKE<[01] PERFORMED CONDITIONAL INSPECTION IAW AMM 05-51-56 AND IFIM 21-00-00-810-830 AND FOUND AFT LH LAV WATER HEATER SIGN/ EVIDENCE OF ELECTRICAL SMEELL. R&R AFT LT LAV WATER HEATER IAW AMM 38-13-01.
- [SDR CALA2025100209520](https://openairdocs.org/sdr/CALA2025100209520.md): Potable Water · odor · Oct 2, 2025 · N21108 · Boeing 757224
  > STRONG ODOR IN POTABLE WATER AND LAV WATER, PERFORMED POTABLE WATER SYSTEM DISINFECTION IAW JC B757-MP-6700-38-001-00
- [SDR CALA2025092209073](https://openairdocs.org/sdr/CALA2025092209073.md): Potable Water · contaminated · Sep 21, 2025 · N66848 · Boeing 737924ER
  > MULTIPLE PAX AND FAS STATE THAT HOT WATER, SMELLS AND TASTES LIKE CHE MICALS, CA SMELLED TO CONFIRM. DRAINED PORTABLE WATER TWICE. RESERVICED AND RAN WATER THRU ALL COFFEEMAKERS AND RAN ALL LAVS SINK WATER. NO SMELL. AC OK FOR SERVICE
- [SDR SWAA2025092216592](https://openairdocs.org/sdr/SWAA2025092216592.md): Filter · odor · Sep 19, 2025 · N8769Q · Boeing 7378
  > FORWARD GALLEY COFFEE MAKER WATER HAS DISCOLORATION AND FOUL ODOR. OK TO CONTINUE PER MEL 38-10-01A, POTABLE WATER SYSTEM - INDIVIDUAL COMPONENTS DEACTIVATED & ISOLATED. WITH SP1B AND AUTHORIZATION NUMBER 280771. REPLACED FWD GALLEY WATER FILTER PER AMM 25
- [SDR CALA2025090208341](https://openairdocs.org/sdr/CALA2025090208341.md): Potable Water · odor · Aug 30, 2025 · N77598 · Boeing 7379
  > STRONG CLEANER SMELL AND TASTE IN POTABLE WATER WATER SVC VENDOR NOTIFIED TO SERVICE WATER.

Next page: https://openairdocs.org/jasc/3810/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE jasc_code = '3810'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/jasc/3810/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.