- [SDR MASA20261022252](https://openairdocs.org/sdr/MASA20261022252.md): Floor Support · corroded · Oct 8, 2026 · N83329 · Emb ERJ170200LL
  > DURING HEAVY CHECK, INSPECTIONS OF THE INTERNAL FUSELAGE FLOOR STRUCTURE AR CFIII, CORRODED INTERCOSTAL AT FR 90 UH TO FR 91 UH, LBL 10, REMOVED AND REPLACED IAW ERJ 175 SRM 51-41-01. NRC# 4502703-2000-0288, REV 45 DATED MA Y-28-2021.
- [SDR SWAA2024080908577](https://openairdocs.org/sdr/SWAA2024080908577.md): Floor Panel · pulled · Jul 3, 2024 · N257WN · Boeing 7377H4
  > AFT FLOOR PANEL 241ABF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 241ABF AFT FLOOR PANEL UPPER SKIN HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1 AND BOEING DWG: 147A5810 ID: 0088.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1
- [SDR JJBA20240404011](https://openairdocs.org/sdr/JJBA20240404011.md): Channel · cracked · Mar 14, 2024 · N14186 · Emb EMB145XR
  > AT CF3 FLOOR STRUCTURTE AREA, CRACK FOUNF ON L/H OMEGA BEAM OUTBD ANGLE BTW FR 46-50 ON L/H OMEGA BEAM OUTBD ANGLE REPLACED
- [SDR QXEA2024031800067](https://openairdocs.org/sdr/QXEA2024031800067.md): Seat Track · corroded · Mar 12, 2024 · N645QX · Emb ERJ170200LR
  > CORROSION IN RH IB SEAT TRACK FR 84. REMOVED DAMAGED SECTION AND PERFORMED SEAT TRACK SPLICE REPAIR, INSTALLED SEAT TRACK SPLICES AND NEW SEAT TRACK SECTION ON RH IN SEAT TRACK AT FR 84 REF ETD2022-170-022163.
- [SDR YENA2023111601393](https://openairdocs.org/sdr/YENA2023111601393.md): Unknown · unknown · Nov 15, 2023 · N203JB · Emb ERJ190100IGW
  > DURING HEAVY MAINTENANCE: FUSELAGE / CENTER FUSELAGE III STR28R / BWTN FR86-FR90 /CORROSION - PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR)
- [SDR SWI2023F00590](https://openairdocs.org/sdr/SWI2023F00590.md): Unknown · corroded · Oct 23, 2023 · N743SK · Cndair CL6002C10
  > CORROSION ON GALLEY FLOOR FWD INBD MOUNT FITTING BETWEEN FS 280.00 - 295.00, RBL9-RBL18 HN00118605 (C-CHECK RO 12/23/2023) EVALUATED ON GALLEY FLOOR FWD INBD MOUNT FITTING BETWEEN FS 280.00 - 295.00, RBL9-RBL18 CORROSION IS EXFOLIATED AROUND NUTPLATE HOLE
- [SDR QXEA2023032000039](https://openairdocs.org/sdr/QXEA2023032000039.md): Unknown · unknown · Mar 19, 2023 · N632QX · Emb ERJ170200LR
  > CORROSION IN SHEAR CLIP FR 87 BETWEEN STR 27-28R. REMOVED AND REPLACED SHEAR CLIP FR-87 BETWEEN STR 27-28R SRM 51-40-08.
- [SDR SWIA20230519042](https://openairdocs.org/sdr/SWIA20230519042.md): Unknown · corroded · Mar 15, 2023 · N967SW · Cndair CL6002B19
  > GALLEY FLOOR SUPPORT STRUCTURE CORRODED AT FS319.70 BETWEEN RBL 9 AND LBL9 (UPPER AND LOWER PLATES) (C-CHECK RO 5/15/2023) REMOVED AND REPLACED WITH NEW GALLEY FLOOR SUPPORT STRUCTURE PLATE BOMBARDIER DWG 601R38778 REV-H AND REF CRJ200 SRM 51-42-06 REV
- [SDR SWAA2023020782456](https://openairdocs.org/sdr/SWAA2023020782456.md): Structure · corroded · Dec 16, 2022 · N7855A · Boeing 73779P
  > CORROSION FLOOR STRUCTURE STRAP LOCATED BS1006 TO BS1040 AT LBL3 AND WL208.1 AT AFT GALLEY AREA 2022-696985<[01] TOOL USED UT EQUIPMENT P/N: 45MG; S/N: 130066701; CAL DUE DATE: 08-APR-23;[02] REPLACED STRAP LOCATED FLOOR STRUCTURE STRAP LOCATED BS1006 TO BS104
- [SDR A6WA202210158343](https://openairdocs.org/sdr/A6WA202210158343.md): Shear Plate · corroded · Oct 15, 2022 · N456ZW · Cndair CL2151A10
  > INBOARD OF RBL9 AT FS310 AND FS330.0 SHEAR PLATE AND MOUNT CORROSION ***AIRCRAFT REMOVED FROM SERVICE **** REMOVED AND REPLACED INBOARD OF RBL9 AT FS310 AND FS330.0 SHEAR PLATE AND MOUNT
- [SDR SWAA2022082430778](https://openairdocs.org/sdr/SWAA2022082430778.md): Strip · elongated · Jul 18, 2022 · N950WN · Boeing 7377H4
  > AFT CARGO L/H SIDE CAP STRIPS FOUND WITH ELONGATED HOLES / [01] RECEIVED AFT CARGO CAP STRIPS P/NS 453A2611-10; 453A2611-8; 453A2611-4;[02] VERIFIED RECEIVING AFT CARGO CAP STRIPS P/NS 453A2611-10; 453A2611-8; 453A2611-4;[03] STEP 1 ENTER IN ERROR; RECEIVED A
- [SDR YENA2022070500645](https://openairdocs.org/sdr/YENA2022070500645.md): None · none · Jul 2, 2022 · N328JB · Emb EMB110*
  > DURING HEAVY MAINTENANCE, FUSELAGE: SEVERAL CORROSION POINTS ON STILL, RIGHT-FLOOR, FWD FUS, AL BTW FR-12 / FR-14 AND Y+1200 AND +1298; ALL WORK ACCOMPLISHED ON TOMEX NRC 00208, CORROSION ON STILL, RIGHT-FLOOR, FWD FUS, AL BTW FR-12 / FR-14 AND Y+1200 / +12
- [SDR YENA2022070500644](https://openairdocs.org/sdr/YENA2022070500644.md): None · none · Jul 2, 2022 · N328JB · Emb EMB110*
  > DURING HEAVY MAINTENANCE, FUSELAGE: CENTER FUSELAGE III, FLOOR BEAM SEAT TRACK AT FR84 AND Y=330. CORROSION. PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR)
- [SDR R61A2022071400430](https://openairdocs.org/sdr/R61A2022071400430.md): Skin Panel · corroded · Jun 18, 2022 · N235JQ · Emb ERJ170200LR
  > REPAIRED CFIII SKIN CORRODED FWD OF LAV SERVICE DOOR BY MEANS OF BLENDING OUT DAMAGE AND INSTALLING FABRICATED DOUBLER REF EMB SRM 53-23- 60/REPAIR01.
- [SDR YENA2022061400602](https://openairdocs.org/sdr/YENA2022061400602.md): Stringer · corroded · Jun 13, 2022 · N306JB · Emb ERJ190100IGW
  > DURING HEAVY MAINTENANCE, FUSELAGE/ CENTER FUSELAGE III / FRAME 80 / STRINGERS 26R AND 28R / CORROSION / TEMPORARY REPAIR. (CONSIDERED AS A MAJOR REPAIR)
- [SDR YENA2022061400601](https://openairdocs.org/sdr/YENA2022061400601.md): Stringer · corroded · Jun 13, 2022 · N306JB · Emb ERJ190100IGW
  > DURING HEAVY MAINTENANCE, FUSELAGE/ CENTER FUSELAGE III / FRAME 80 / STRINGERS 26R AND 28R / CORROSION/ PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR)
- [SDR EE4Y202260715775](https://openairdocs.org/sdr/EE4Y202260715775.md): Skin Panel · none · Jun 7, 2022 · Emb EMB110*
  > CENTER FUSELAGE III BETWEEN FR89 AND FR90 COMMON TO STR 13LH EXISTING REPAIR WITH A DISCREPANCY. NOTE: THE FUSELAGE SKIN PANEL WAS REPAIRED AS PER EMBRAER ETD2022-190-018961 GUIDELINES AS STATED IN COOPESA ENGINEERING ORDER NO: COO-CO 2022-15755 INSTRUCTIONS (
- [SDR YENA2022051700486](https://openairdocs.org/sdr/YENA2022051700486.md): Skin · corroded · May 16, 2022 · N304JB · Emb ERJ190100IGW
  > DURING HEAVY MAINTENANCE, FUSELAGE / CENTER FUSELAGE III / LOWER SKIN / BTW FR86 - FR87 AND STGR 29LH - 29RH / CORROSION - PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR).
- [SDR QXEA2022041300150](https://openairdocs.org/sdr/QXEA2022041300150.md): None · none · Apr 11, 2022 · N629QX · Emb ERJ170200LR
  > CORROSION ON CENTER FUSELAGE III RH SPLICE FR 89 AND Y=+11. REMOVED AND REPLACED CENTER FUSELAGE III SPLICE BETWEEN FR 89 AND Y=+11 IAW SRM 51-40-08.
- [SDR QXEA2022041300149](https://openairdocs.org/sdr/QXEA2022041300149.md): Shear Panel · corroded · Apr 11, 2022 · N629QX · Emb ERJ170200LR
  > CORROSION ON CENTER FUSELAGE III RH SHEAR PANEL BETWEEN FR 87-88 AND Y=+12. REMOVED AND REPLACED CENTER FUSELAGE III RH SHEAR PANEL BETWEEN FR 87-88 AND Y=+12 IAW SRM 51-40-08.
- [SDR SWIA202265382](https://openairdocs.org/sdr/SWIA202265382.md): None · corroded · Apr 1, 2022 · N247SY · Emb ERJ170200LR
  > STILL RIGHT FWD WET AREA FRAME 12-14 TWO AREAS OF CORROISION AS MARKED. (C CHECK RO 4/16/22) CORROSION OUT OF LIMITS REF. EMB SRM 53-10-10/AD06. REMOVED AND REPLACED SILL AT RIGHT FWD WET AREA FRAME 12-14 REF. EMB SRM 51-40-08.
- [SDR SWIA202265297](https://openairdocs.org/sdr/SWIA202265297.md): None · corroded · Mar 27, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION ON FWD WET AREA L/H FLOOR DOUBLER BETWEEN FR19-20 AS MARKED. (C CHECK RO 04/08/22) / REMOVED AND REPLACED OUT OF LIMITS DOUBLER WITH NEW L/H DOUBLER FR19-20 IN WET AREA AS REQUIRED REF SRM 51-40-08
- [SDR SWIA202265282](https://openairdocs.org/sdr/SWIA202265282.md): None · corroded · Mar 27, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION ON FWD WET AREA R/H FLOOR BEAM BETWEEN FR13-18 IN 6 LOCATIONS AS MARKED. (C CHECK RO 04/08/22) / REMOVED AND REPLACED R/H FLOOR BEAM BETWEEN FR12-21 REF EMB SRM 51-40-08. BEAM WAS REPLACED WITH OEM PART NO CHANGE TO WEIGHT AND BALANCE NOTED. SE
- [SDR SWIA202265292](https://openairdocs.org/sdr/SWIA202265292.md): None · corroded · Mar 26, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION FOUND IN AFT WET AREA LOCATED ON FR 87 AT LBL 4.375" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED WITH NEW MIDDLE SHEAR PLATE AT AFT WET AREA LOCATED ON FR 87 AT LBL 4.375", REF SRM 51-40-08
- [SDR SWIA202265291](https://openairdocs.org/sdr/SWIA202265291.md): None · corroded · Mar 26, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION FOUND IN AFT WET AREA LOCATED ON GUSSET PLATE FR 87 AT RBL 40" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED LOCATED ON GUSSET PLATE FR 87 AT RBL 40", REF SRM 51-40-08.
- [SDR SWIA202265290](https://openairdocs.org/sdr/SWIA202265290.md): None · corroded · Mar 26, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION FOUND IN AFT WET AREA LOCATED ON FR 90 AT RBL 23" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED WITH NEW GUSSET AT AFT WET AREA LOCATED ON FR 90 AT RBL 23", REF SRM 51-40-08.
- [SDR SWIA202265289](https://openairdocs.org/sdr/SWIA202265289.md): None · corroded · Mar 26, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION FOUND IN AFT WET AREA LOCATED ON FR 90 AT RBL 11" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED WITH NEW GUSSET AT AFT WET AREA LOCATED ON FR 90 AT RBL 11", REF SRM 51-40-08.
- [SDR SWIA202265288](https://openairdocs.org/sdr/SWIA202265288.md): None · corroded · Mar 26, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION FOUND IN AFT WET AREA LOCATED ON FR 90 AT LBL 4.375" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED GUSSET AT FR 90 AT LBL 4.375" REF EMB SRM 51-40-08
- [SDR SWIA202265287](https://openairdocs.org/sdr/SWIA202265287.md): None · corroded · Mar 26, 2022 · N165SY · Emb ERJ170200LR
  > CORROSION FOUND IN AFT WET AREA ALONG RH SHEAR PANEL ON FR 87. (C CHECK RO 04/08/22) REMOVED AND REPLACED RH SHEAR PANEL ON FR 87, REF SRM 51-40-08.
- [SDR SWIA202265815](https://openairdocs.org/sdr/SWIA202265815.md): None · cracked · Mar 18, 2022 · N816SK · Cndair CL6002D24
  > THE GALLEY #2 HAS A CORRODED OTBD/FWD FLOOR MOUNT FITTING (ROUND FITTING). (C CHECK RO 5/23/22) REPLACED THE GALLEY #2 OTBD/FWD FLOOR MOUNT FITTING WITH A SERVICEABLE FLOOR MOUNT FITTING (P/N 9393251-3) AND NEW HARDWARE REFERENCING CRJ 900 SRM 51-41-02-0
- [SDR QXEA2022031400115](https://openairdocs.org/sdr/QXEA2022031400115.md): Shear Panel · corroded · Mar 7, 2022 · N627QX · Emb ERJ170200LR
  > CORROSION ON FUSELAGE III FLOOR STRUCTURE RH SHEAR PANEL BETWEEN FR 87-88 AND Y= +24. REMOVED AND REPLACED SHEAR PANEL BETWEEN FR 87-88 AND Y= +24 IAW SRM 51-40-08.
- [SDR SWIA202265125](https://openairdocs.org/sdr/SWIA202265125.md): None · corroded · Mar 1, 2022 · N244SY · Emb ERJ170200LR
  > FWD WET AREA RIGHT STILL AT FR 14 HAS CORROSION ON AFT LH CORNER (C-CHECK RO 03-19-2022) REMOVED AND REPLACED FWD WET AREA RIGHT SILL AT FR 14 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06 AND CPM 51-25-00910-001-A
- [SDR R61A2022031000188](https://openairdocs.org/sdr/R61A2022031000188.md): Seat Track · corroded · Feb 21, 2022 · N722YX · Emb ERJ170200LR
  > FWD FUSELAGE FLOOR CORROSION FOUND ON I/B L/H SEAT TRACK BTWN FR 18-19. R&R SEAT TRACK FWD FUSELAGE L/H I/B FR 12-FR20 IAW EBM 170/175 SRM 51-41-01, 51-41-02, 51-43-03 AND 51-43-04.
- [SDR SWIA202264788](https://openairdocs.org/sdr/SWIA202264788.md): None · corroded · Feb 15, 2022 · N108SY · Emb ERJ170200LR
  > AFT WET AREA, RH SIDE, PANEL, SHEAR CORRODED IN 2 PLACES, 2ND AND 4TH BOLT HOLES FROM RH END (C CHECK RO 03/07/2022) REMOVED AND REPLACED AFT WET AREA, RH SIDE, PANEL, SHEAR REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06
- [SDR SWIA202264787](https://openairdocs.org/sdr/SWIA202264787.md): None · corroded · Feb 15, 2022 · N108SY · Emb ERJ170200LR
  > AFT WET AREA, RH SIDE, PANEL SUPPORT CORRODED IN 2 PLACES, AFT AND CENTER BOLT HOLES (C CHECK RO 03/07/2022) REMOVED AND REPLACED AFT WET AREA RH SIDE PANEL SUPPORT REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-04, 50-23-05, AND 51-23-06.
- [SDR SWIA202264786](https://openairdocs.org/sdr/SWIA202264786.md): None · corroded · Feb 15, 2022 · N108SY · Emb ERJ170200LR
  > AFT WET AREA, RH SIDE, GUSSET PLATE CORRODED AT INBOARD BOLT HOLE (C CHECK RO 03/07/2022) REMOVED AND REPLACED AFT WET AREA, RH SIDE, GUSSET PLATE AT FR90 REF EMB SRM 51-40-08 RESTORED SURFACE PROTECTION REF SRM 51-23-06 APPLIED CIC REF CPM 51-25-00
- [SDR SWIA202264576](https://openairdocs.org/sdr/SWIA202264576.md): None · corroded · Feb 3, 2022 · N241SY · Emb EMB110*
  > AFT WET AREA FR89 R/H PANEL SUPPORT CORRODED THRU AT GALLEY MOUNT BOLT AREA (C CHECK RO 02/21/2022) REMOVED AND REPLACED RH PANEL SUPPORT FR89 REF SRM 51-40-08
- [SDR SWIA202264575](https://openairdocs.org/sdr/SWIA202264575.md): None · corroded · Feb 3, 2022 · N241SY · Emb EMB110*
  > AFT WET AREA FR90 R/H SIDE GUSSET PLATE (TEXAS) CORRODED AT GALLEY MOUNT BOLT HOLE (C CHECK RO 02/21/2022) REMOVED AND REPLACED CORRODED AFT GUSSET PLATE FR90 R/H WITH NEW GUSSET PLAT AS REQUIRED REF SRM 51-40-08
- [SDR SWIA202264564](https://openairdocs.org/sdr/SWIA202264564.md): None · corroded · Feb 2, 2022 · N167SY · Emb ERJ170200LR
  > R/H OUTBOARD FLOOR SILL PLATE CORRODED AT FR.17 AS MARKED. (C CHECK RO 2/20/2022) REMOVED AND REPLACED CORRODED R/H OUTBOARD FLOOR SILL PLATE AT FR.17 AS MARKEDWITH NEW FLOOR SILL REQUIRED REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.
- [SDR SWIA202264563](https://openairdocs.org/sdr/SWIA202264563.md): None · corroded · Feb 2, 2022 · N167SY · Emb ERJ170200LR
  > R/H FORWARD OUTBOARD SILL PLATE CORRODED AT FR.14 (C CHECK RO 2/20/2022) REMOVED AND REPLACED R/H FWD OB SILL PLATE AT FRAME 12-14 REF EMB SRM 51-40-08
- [SDR SWIA202265199](https://openairdocs.org/sdr/SWIA202265199.md): None · corroded · Feb 1, 2022 · N875AS · Cndair CL6002B19
  > CORROSION FOUND UNDERNEATH GIRT BAR FITTINGS AT SERVICE DOOR LOWER THRESHOLD FS319.70 TO FS349.00 STR17R (C-CHECK RO 3-25-22) REMOVED LOWER THESHOLD ANGLE REF CRJ 200 SRM 51-42-06 AND 51-42-36, INSTALLED LOWER THESHOLD ANGLE REF CRJ 200 SRM 51-42-06, REF
- [SDR SWIA202264562](https://openairdocs.org/sdr/SWIA202264562.md): None · corroded · Feb 1, 2022 · N167SY · Emb ERJ170200LR
  > CORROSION ON AFT WET AREA GUSSET PLATE AT FR90 RBL 10" AS MARKED. (C CHECK RO 2/20/2022) / REMOVED AND REPLACED AFT WET AREA GUSSET PLATE AT FR90 RBL 10", REF SRM 51-40-08
- [SDR SWIA202264561](https://openairdocs.org/sdr/SWIA202264561.md): None · corroded · Feb 1, 2022 · N167SY · Emb ERJ170200LR
  > CORROSION ON AFT WET AREA GUSSET PLATE AT FR90 RBL 28" AS MARKED. (C CHECK RO 2/20/2022) / REMOVED AND REPLACED AFT WET AREA GUSSET PLATE AT FR90 RBL 28", REF SRM 51-40-08.
- [SDR SWIA202264560](https://openairdocs.org/sdr/SWIA202264560.md): None · corroded · Feb 1, 2022 · N167SY · Emb ERJ170200LR
  > CORROSION ON AFT WET AREA R/H PANEL SUPPORT BETWEEN FR88-91 AS MARKED. / (C CHECK RO 2/20/2022) REMOVED AND REPLACED AFT WET AREA RH PANEL SPPORT BRACKET FRAME 88-91 REF SRM 51-40-08. APPLIED SURFACE PROTECTION RE SRM 51-23-06
- [SDR QXEA2022012800036](https://openairdocs.org/sdr/QXEA2022012800036.md): Support Angle · corroded · Jan 27, 2022 · N625QX · Emb ERJ170200LR
  > CORROSION ON CENTER FUSELAGE III RH INTERCOSTAL BETWEEN FR 90-FR 91 AND Y= +10. REMOVED AND REPLACED CENTER FUSELAGE III RH INTERCOSTAL SUPPORT ANGLE AT FR 90-FR 91 AND Y +10 IAW SRM 51-40-02, 51-40-08.
- [SDR QXEA2022012800035](https://openairdocs.org/sdr/QXEA2022012800035.md): Not Reported · not reported · Jan 27, 2022 · N625QX · Emb ERJ170200LR
  > CORROSION ON CENTER FUSELAGE III RH LONGITUDINAL BEAM AT FR 87 AND Y= +10. REMOVED AND REPLACED CENTER FUSELAGE III RH LONGITUDINAL BEAM AT FR 86 TO-FR 89 AND Y +10 IAW SRM 51-40-02, 51-40-03,51-40-08.
- [SDR QXEA2022012800033](https://openairdocs.org/sdr/QXEA2022012800033.md): Gusset · corroded · Jan 27, 2022 · N625QX · Emb ERJ170200LR
  > CORROSION ON CENTER FUSELAGE III GUSSET AT FR 90 AND Y= +10. REMOVED AND REPLACED GUSSET AT CENTER FUSELAGE III FR 90 AND Y +10 IAW SRM 51-40-02, 51-40-08.
- [SDR YENA2022031500200](https://openairdocs.org/sdr/YENA2022031500200.md): Stringer · corroded · Jan 23, 2022 · N273JB · Emb ERJ190100IGW
  > DURING HEAVY MAINTENANCE, (E/C E22-008-02) FUSELAGE/ CENTER FUSELAGE III / STRINGERS 28LH AND 29 RH / FR 76-77 CORROSION/ PERMANENT REPAIR (CLASSIFIED AS A MAJOR REPAIR)
- [SDR YENA2022031500197](https://openairdocs.org/sdr/YENA2022031500197.md): Stringer · corroded · Jan 23, 2022 · N273JB · Emb ERJ190100IGW
  > DURING HEAVY MAINTENANCE, (E/C E22-008-01) FUSELAGE/ CENTER FUSELAGE III / STRINGERS 28LH AND 29 RH / FR 76-77 CORROSION/ TEMPORARY REPAIR (CLASSIFIED AS A MAJOR REPAIR)
- [SDR SWIA202264322](https://openairdocs.org/sdr/SWIA202264322.md): None · damaged · Jan 12, 2022 · N929SW · Cndair CL6002B19
  > RH CARGO FLOOR SILL FROM FS559+80 FS 559.00+112 REQURE REPLACEMENT (C CHECK RO 02-12-2022) REMOVED AND INSTALL NEW R/H CARGO FLOOR SILL FROM FS559+80 FS 559.00+112 IAW CRJ-200 SRM 51-42-21, CRJ-200 SRM 51-42-06, CRJ-200-SRM 51-45-00 AND DRW# 601R31133

Next page: https://openairdocs.org/jasc/5323/reports.md?page=2

## The whole list in SQL

Runs in DuckDB 1.2 or later on the release's Parquet files over HTTPS:

```sql
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
WHERE jasc_code = '5323'
ORDER BY difficulty_date DESC
```

This list as a web page: https://openairdocs.org/jasc/5323/reports

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.