# SDR 00FDEA0025

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 18, 2000
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N314FE
- Make and model: Doug DC-10-30F
- Registry model: [Doug DC-10-30F](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30f) (OpenAirDocs)
- Aircraft serial: 48312
- System (JASC): [2913 · Hydraulic Pump (Electric/Engine), Main](https://openairdocs.org/jasc/2913)
- Part: Connector
- Condition: Failed
- Location: Hyd Pump
- Stage of operation: IN
- Nature of condition: A
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/00FDEA0025

## Discrepancy

NR 751 - RT W/W FWD INBD ELECT HYD PUMP CANNON PLUG WAS A SHORTED WIRE.  PUMP HAD 2 EA SHORT WIRES CAUSING ELECTRICAL FIRE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.
