# SDR 01FDEA00450

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 14, 2001
- Submitted: June 19, 2001
- Operation: Air carrier
- Aircraft: [N316FE](https://openairdocs.org/aircraft/N316FE), registered now
- Make and model: Doug DC-10-30
- Registry model: [Doug DC-10-30](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30) (OpenAirDocs)
- Aircraft serial: 48314
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Hydraulic Line
- Condition: Damaged
- Location: Hydraulic Sys
- Stage of operation: NR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/01FDEA00450

## Discrepancy

NR 3 HYD QTY LEAK TO A QTY OF .2 GAL CAUSING LVL ALERT OF HYD 3 FAIL.  ACCOMPLISH RED TABS INCLUDING ALT GEAR EXT.  REMOVED AND REPLACED DAMAGED SECTION OF HYD LINE AND INSTALL NEW PIECE OF TUBING AND SWAGGED PER MM 20-10-01-2.  LEAK CK GOOD.  REINSTALLED PANELS AND SERVICED NR 3 HYD SYS.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.