## Discrepancy

ON CLIMBOUT PASSING FL280 (AIR COND DOORS) LIGHT ILLUMINATED INTERMITTENTLY, WENT OUT AT 16000 FEET ON DESCENT. PRESSURIZATION REMAINED ON SCHEDULE  ENT BY: 308389 RPT BY: 061284  FACT  18JUL03  12:26  STL R  FOUND LT AFT PACK DOOR SWITCH WIRES CORRODED AND BROKEN AT CONNECTOR P1-1618.  REPLACED CONNECTOR SWP 20-31. OPS CHECK NORMAL IAW M/M 52-70-07-2  RII:131618 ENT BY: 308389 RPT BY: 308389

---