# SDR 04FDEA00644

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 13, 2004
- Submitted: March 15, 2004
- Operation: Air carrier
- Aircraft: [N585FE](https://openairdocs.org/aircraft/N585FE), registered now
- Make and model: Doug MD-11
- Registry model: [Doug MD-11](https://openairdocs.org/model/mcdonnell-douglas-md-11) (OpenAirDocs)
- Aircraft serial: 48481
- Aircraft time: 41,977 hours, 8,015 cycles
- System (JASC): [2913 · Hydraulic Pump (Electric/Engine), Main](https://openairdocs.org/jasc/2913)
- Part: Pump
- Condition: Inoperative
- Location: Nr 3 Hyd System
- Stage of operation: CL
- How discovered: O
- Nature of condition: M, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/04FDEA00644

## Discrepancy

IN CLIMB AT FL 350 HYD PUMP 3L OFF, ALERT ILLUMINATED FOLLOWED BY HYD PUMP 3R FAULT.  ALERT WITH TEMP AMBER AT 97 DEG AND AMBER -T- ILLUMINATED ON BOTH PUMPS.  BOTH PUMPS HAD OVERTEMPED.  RELEASED FOR SERVICE PER MEL/CDL: 29-11-01-A, MEL 29-11-01-A: ENG NR 3 HYD PUMP INOP.  PUMP REMOVED, RNR ENG NR 3 UPPER LEFT EDP PER MM REF 29-11-20-4-1.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.