# SDR 05FDEA00608

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 18, 2005
- Submitted: March 21, 2005
- Operation: Air carrier
- Aircraft: N302FE
- Make and model: Doug DC-10-30
- Registry model: [Doug DC-10-30](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30) (OpenAirDocs)
- Aircraft serial: 46801
- Aircraft time: 75,459 hours, 21,998 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Shutoff Valve
- Part number: 1489951
- Condition: Leaking
- Location: Hyd System
- Stage of operation: CL
- How discovered: O
- Nature of condition: K
- Precautionary procedure: J
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/05FDEA00608

## Discrepancy

APPROXIMATELY 5 MINUTES AFTER TAKEOFF, MASTER CAUTION LIGHT ILLUMINATED AND OBSERVED BOTH LT & RT NR 2 EDP LIGHT ON, PRESSURE AND QUANTITY RAPIDLY WENT TO ZERO.  FOUND 1-2 NONREVERSIBLE MOTOR PUMP SHUTOFF VALVE LEAKING FROM BACKUP RING.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.