# SDR 0601881240

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 3, 2006
- Submitted: September 6, 2006
- Operation: Air carrier
- Aircraft: N240NW
- Make and model: Doug DC-10-30
- Registry model: [Doug DC-10-30](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30) (OpenAirDocs)
- Aircraft serial: 48319
- Aircraft time: 59,353 hours, 9,692 cycles
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Bottle
- Condition: Low
- Location: 4r Door
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/0601881240

## Discrepancy

DURING LINE CHECK FOUND DOOR 4R PNEUMATIC BOTTLE PRESSURE AT ZERO. ICN MAINTENANCE ATTEMPTED TO RECHARGE BOTTLE BUT WERE UNSUCCESSFUL. DEFERRED IAW MEL 52-10 AND INSTALLED PLACARD NR 032612. HNL MAINTENANCE RESET PLUNGER ABOVE BOTTLE AND SERVICED IAW MM 52-12-06. OPS CHECKED GOOD, CLEARED LIDS, REMOVED PLACARD AND NOTIFIED MC.  				

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.