# SDR 06FDEA03937

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 9, 2006
- Submitted: November 10, 2006
- Operation: Air carrier
- Aircraft: N311FE
- Make and model: Doug DC-10-30F
- Registry model: [Doug DC-10-30F](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30f) (OpenAirDocs)
- Aircraft serial: 46871
- Aircraft time: 83,282 hours, 22,621 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Wire Harness
- Part number: C5012100C
- Condition: Burned
- Location: External Power
- Stage of operation: NR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/06FDEA03937

## Discrepancy

GROUND POWER IS INTERMITTENT.  POWER SHUTS DOWN WHEN A LOAD IS APPLIED.  FOUND BURNT "C" PHASE OUTPUT CABLE (C501-21-00C) OF GROUND SERVICE RELAY.  REPLACED DAMAGED C501-21-00C CABLE BETWEEN EXTERNAL POWER CONTACTOR R2-218 AND 53-517 REF W/D 24-41-01 PG 703 SHT 2 OF 2. OPS CHECK NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.