# SDR 06FDEA1579

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 24, 2006
- Submitted: April 25, 2006
- Operation: Air carrier
- Aircraft: [N609FE](https://openairdocs.org/aircraft/N609FE), registered now
- Make and model: Doug MD-11
- Registry model: [Doug MD-11](https://openairdocs.org/model/mcdonnell-douglas-md-11) (OpenAirDocs)
- Aircraft serial: 48549
- Aircraft time: 46,221 hours, 10,458 cycles
- System (JASC): [2120 · Air Distribution System](https://openairdocs.org/jasc/2120)
- Part: Odor
- Condition: Unknown
- Location: Cabin
- Stage of operation: CR
- How discovered: 9
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/06FDEA1579

## Discrepancy

PDIS: DURING CRUISE ENCOUNTERED ICING CONDITIONS.  WHEN WINDOW HEAT WAS TURNED ON A VERY STRONG ELECTRICAL SMOKE SMELL.  NO VISIBLE SMOKE.  NARROWED SMELL DOWN TO THE F/O (RIGHT) WINDOW HEAT.  REPLACED ANTI-ICE CONTROL PANEL PRECAUTIONARY.  REPLACED WINDSHIELD ANTI-ICE SUPPRESSOR LOWER RT CORNER TERMINAL AND TERMINAL BLOCK (S-T).  REINSTALLED THE GLARESHIELD AND GCP.  PERFORMED RTS OF FCC-1&2 FOR GCP ALL TEST  PASSED.  A/C OK FOR SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.