# SDR 08FDEA01386

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 11, 2008
- Submitted: April 11, 2008
- Operation: Air carrier
- Aircraft: N425FE
- Make and model: Airbus A310-203
- Registry model: [Airbus A310-203](https://openairdocs.org/model/airbus-industrie-a310-203) (OpenAirDocs)
- Aircraft serial: 264
- Aircraft time: 36,499 hours, 24,558 cycles
- System (JASC): [5310 · Fuselage Main, Structure](https://openairdocs.org/jasc/5310)
- Part: Stringer
- Part number: A5361202539200
- Condition: Cracked
- Location: Zone 100
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/08FDEA01386

## Discrepancy

THE AVOINICS COMPARTMENT FLOOR STRUCTURE FROM FRAME 16 TO 17; STRINGER 44 L IS CRACKED.  FORMED EDGING IAW DWG A53612025. HEAT TREATED IAW TPS 1003;  REV A. TREATED IAW SRM 51-21-10 & 51-23-10.   PART MARKED IAW GMM 7-0-1000;  STEP 7-B.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.