# SDR 08FDEA01738

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 27, 2008
- Submitted: May 5, 2008
- Operation: Air carrier
- Aircraft: N384FE
- Make and model: Doug MD-10-10F
- Registry model: [Doug MD-10-10F](https://openairdocs.org/model/mcdonnell-douglas-md-10-10f) (OpenAirDocs)
- Aircraft serial: 46617
- Aircraft time: 72,495 hours, 28,969 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Transmitter
- Part number: 9273184
- Part serial: 70
- Condition: Failed
- Location: Nr 1 Pack
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/08FDEA01738

## Discrepancy

RECEIVED A LEVEL 1 PACK 2 FLOW DISAG ALERT IN  FLIGHT 6 TIMES.  REMOVED AND REPLACED PACK 2 FLOW CONTROL VALVE, REF MM 21-51-02-4.  REMOVED AND REPLACED PACK 2 FLOW TRANSMITTER, REF MM 21-52-01-4.  OPS AND LEAK CHECK OK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.