## Discrepancy

1/4 INCH CRACK IN FLOORBEAM C25 BETWEEN SEAT TRACK 2R AND 3R AT UPPER RADIUS IN FRONT FACE STIFFENER.  REMOVED CRACK AND INSTALLED FLOORBEAM REPAIR ON FLOORBEAM FR C25, BETWEEN SEAT TRACKS 2RT AND 3RT IAW A310-200 SRM 53-10-15 FIG, 206.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.