# SDR 1XLA20180322001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 22, 2018
- Submitted: March 22, 2018
- Operation: Air carrier
- Aircraft: [N1413X](https://openairdocs.org/aircraft/N1413X), registered now
- Make and model: Robsin R44RAVENII
- Aircraft serial: 12157
- System (JASC): [2597 · Equipment/Furnishings Wiring](https://openairdocs.org/jasc/2597)
- Part: Connector
- Condition: Failed
- Location: Elt
- Stage of operation: IN
- How discovered: C
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/1XLA20180322001

## Discrepancy

DURING ELT INSPECTION, IT WOULD NOT TEST WITH RC-102 REMOTE CONTROL.  PROBLEM DIAGNOSED AS FAILED SOLDER CONNECTION ON DIN-12 CONNECTOR AT THE ELT.  RESOLDERED AND TESTED OK.

---