# SDR 20000620SH026

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 7, 2000
- Submitted: June 20, 2000
- Operation: Air carrier
- Aircraft: [N686CG](https://openairdocs.org/aircraft/N686CG), registered now
- Make and model: Gulstm GIV
- Aircraft serial: 1171
- System (JASC): [2810 · Fuel Storage](https://openairdocs.org/jasc/2810)
- Part: Fuel Line
- Part number: D10007D06
- Condition: Sheared
- Location: Rt Wing
- Part time: 2,467 hours
- Component: Pressure Line, Gulstm
- Component part number: 1159P42012050
- Stage of operation: NR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/20000620SH026

## Discrepancy

PILOTS REPORTED RT REMOTE FUELING SHUTOFF AND FLOAT PRE-CHECK INOPERABLE. INVESTIGATION REVEALED THE PRESSURE LINE FROM THE HIGH-LEVEL PILOT VALVES TO THE TANK PRESSURE SENSING VALVE INSIDE THE WING AT RBL 90.00 SHEARED OFF AT THE FORWARD ATTACH FITTING.  (X)

---