## Discrepancy

POWER SUPPLY RETURNED FOR REPAIR AFTER REPORTED THAT UNIT WAS SMOKING DURING FLIGHT SEGMENT.  DURING TEAR-DOWN, FOUND ''SCORCHED & MELTED'' CAPACITORS AND COMPONENTS WITHIN POWER SUPPLY.  LABORATORY INVESTIGATION OF ROOT CAUSE STILL ONGOING.  A NIC MFG CAPACITOR IS SUSPECTED.  FINAL FIX STILL BEING WORKED.  AS A PRECAUTION, NIC CAPACITORS HAVE BEEN PURGED FROM REPAIR STATION STOCK AND COORDINATED PRODUCTION.  AIRLINE AND BOEING COORDINATION ONGOING.  (X)

---